{"product_id":"bently-nevada-330878-90-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-90-05 3300 XL 50 mm Proximitor Sensörü","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (Multiple Approvals) specify this \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330878-90-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhile DIN mount configurations (Option 91) and 5.0-meter systems (Option 50 or 51) are available, this panel-mount, 9.0-meter system matches 330876 probes and 330877 extension cables for longer transmission distances. The Multiple Approvals selection allows installation in designated hazardous environments where compliance is required. The sensor utilizes advanced eddy-current technology to process displacement signals from a 50 mm probe, rendering it highly effective for differential expansion (DE) or rotor expansion (RX) measurements on steam turbine generators.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e Configured for a 9.0 m (29.5 ft) system length, providing compatibility with corresponding 50 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel-mount physical design for secure attachment to mounting plates or internal enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Option 05 designates multiple global hazardous area certifications, including CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Built-in SpringLoc terminal strips provide fast, highly robust field connections without specialized tools.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e Robust design elements shield signal integrity against nearby high-frequency radio interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) measurement on utility steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eRotor expansion (RX) monitoring to track thermal growth differentials.\u003c\/li\u003e\n  \u003cli\u003eAxial position and displacement tracking in heavy industrial rotating machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBegins at 1.3 mm (50 mils) to 29.2 mm (1150 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Terminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Field Wire Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground reference\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDynamic analog output voltage signal\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Proximitor Sensor on a clean, flat surface using the standard panel-mount configuration holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the field wiring shield is connected to the monitor common ground and insulated at the Proximitor end to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Depress the SpringLoc lever, insert the stripped conductor (0.2 to 1.5 mm2), and release to secure. No special tools are needed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Cable Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for coaxial and triaxial system cables to prevent signal loss or conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCertification Body \/ Standard\u003c\/th\u003e\n      \u003cth\u003eApproval Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EMC) and RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNorth American Approvals (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc; Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2019 Rules for Conditions of Classification\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572603755,"sku":"330878-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-90-05-proximitor-sensor-gwpqylptnek_75a84746-c19c-440e-9220-efa4c992eccd.jpg?v=1765440866","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330878-90-05-3300-xl-50-mm-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}