{"product_id":"bently-nevada-330901-00-15-70-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-15-70-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 1\/4-28 UNF stainless steel probe body (Option 00) with a 1.5 in overall case (Option 15) and a 7.0 m standard coaxial lead (Option 70) specifies this 3300 NSv proximity probe configuration — \u003cstrong\u003e330901-00-15-70-02-05\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eCompared to the armored 330902 variant, this 330901 unarmored model provides high cable flexibility for tight bends. It is used in the \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e transducer system to monitor radial vibration, radial position, or axial position in small-bore rotating machinery with strict side-view or counterbore clearances, such as centrifugal air compressors and refrigeration systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a 0.0 in unthreaded length, providing a fully threaded case over the entire case length.\u003c\/li\u003e\n  \u003cli\u003eOption 15 specifies a 1.5 in overall case length with 1\/4-28 UNF-2A threads.\u003c\/li\u003e\n  \u003cli\u003eOption 70 provides a 7.0 m total length probe cable without additional extension requirements in standard loops.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes a miniature coaxial ClickLoc connector on a standard unarmored 75 ohm coaxial cable.\u003c\/li\u003e\n  \u003cli\u003eOption 05 delivers Multiple Approvals for hazardous area applications including CSA, ATEX, and IECEx certifications.\u003c\/li\u003e\n  \u003cli\u003ePPS (Polyphenylene sulfide) tip material bonded to the stainless steel body with the patented TipLoc molding method.\u003c\/li\u003e\n  \u003cli\u003eHigh chemical resistance suited for process gas environments and harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and radial position measurements on shafts smaller than 51 mm (2 in).\u003c\/li\u003e\n  \u003cli\u003eAxial position and thrust measurements on flat targets smaller than 15 mm (0.6 in).\u003c\/li\u003e\n  \u003cli\u003eIndustrial compressors including centrifugal, refrigeration, and process gas machinery with restrictive target clearance.\u003c\/li\u003e\n  \u003cli\u003eTachometer, zero-speed, and phase reference measurements (Keyphasor signals).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-15-70-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 in (38 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003e7.0 meters (23.0 ft) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-15-70-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximitor Sensor (330980) and 3300 NSv Extension Cable (330930)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 in (38 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.0 meters (23.0 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum rated probe case to probe lead \/ lead to connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the following installation practices are observed for optimal performance:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eStandard bend radius: Minimum 25.4 mm (1.0 in) for the unarmored coaxial cable.\u003c\/li\u003e\n  \u003cli\u003eRecommended installation torque: 5.1 N-m (45 in-lb) for 1\/4-28 UNF probe cases, with a maximum rated limit of 7.3 N-m (65 in-lb).\u003c\/li\u003e\n  \u003cli\u003eGrounding: Isolate the probe tip and case from adjacent machinery metals to prevent signal interference. Run field wiring inside dedicated, grounded conduit systems.\u003c\/li\u003e\n  \u003cli\u003eConnectors: Always lock the miniature ClickLoc coaxial connections by turning them until they click securely in place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis transducer component complies with the following standards when used as a system:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMultiple hazardous area approvals (Option 05): ATEX, IECEx, and CSA certifications for intrinsically safe (Zone 0\/Class I Div 1) and non-incendive (Zone 2\/Class I Div 2) installations.\u003c\/li\u003e\n  \u003cli\u003eCE Mark: European Community Directive compliance under EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: Rated for use in SIL 2 applications (HFT = 0) or SIL 3 applications (HFT = 1 in redundant systems).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666770129259,"sku":"330901-00-15-70-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-15-70-02-05-3300-nsv-proximity-probes-bgpphx2rolr_324aad19-9eb5-420e-9dd6-b81c7d530abc.jpg?v=1765447274","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330901-00-15-70-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}