{"product_id":"bently-nevada-330901-00-19-10-02-00-3300-nsv-proximity-probes","title":"Bently Nevada 330901-00-19-10-02-00 3300 NSv Yakınlık Probları","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length) and Option 19 (1.9 in overall case length) specify this unarmored standard-mount probe configuration — \u003cstrong\u003e330901-00-19-10-02-00\u003c\/strong\u003e. This \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e features a 1\/4-28 UNF thread without stainless steel armor, facilitating installation in locations with limited radial clearance or restricted target size. The system interfaces with the 3300 XL NSv Proximitor Sensor and extension cable to measure non-contact shaft vibration and axial position on small-diameter rotors or high-speed machinery.\u003c\/p\u003e\n\u003cp\u003eIn contrast to variants featuring protective stainless steel armor or integrated connector protectors, this specific model (Option 02) includes a miniature coaxial ClickLoc connector with a standard FEP-insulated coaxial cable. With an overall total length of 1.0 meter (Option 10) and no hazardous area agency approvals required (Option 00), this component provides a direct replacement for standard unarmored configurations in general-purpose industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 unthreaded design provides a fully threaded 1\/4-28 UNF-2A probe body.\u003c\/li\u003e\n  \u003cli\u003eOption 19 case length sets an overall thread casing of 1.9 inches.\u003c\/li\u003e\n  \u003cli\u003eOption 10 total length specifies a 1.0 meter (39 in) probe cable assembly.\u003c\/li\u003e\n  \u003cli\u003eOption 02 connector includes a miniature coaxial ClickLoc connection with standard FEP-insulated cable and no connector protector.\u003c\/li\u003e\n  \u003cli\u003eOption 00 approval status is designated for standard, non-hazardous area applications.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) tip material resists chemical degradation in process environments.\u003c\/li\u003e\n  \u003cli\u003eAISI 304 stainless steel case material provides structural rigidity in demanding industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in rotating machinery protection and monitoring systems where physical access or target geometries are constrained. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall-bore machinery and small-diameter rotating shafts.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and high-speed turbocompressors.\u003c\/li\u003e\n  \u003cli\u003eFluid-film bearing radial vibration and axial thrust measurements in pumps.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearboxes and high-speed spindles with limited radial target clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901-00-19-10-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e19\u003c\/td\u003e\n      \u003ctd\u003e1.9 in (48 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet \/ 39 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-19-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.9 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (39 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 m of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.2 +\/- 0.5 ohms (center conductor to outer conductor for 1.0 m probe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring seal between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead; 220 N (50 lb) at connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.1 N m (45 in lb) recommended; 7.3 N m (65 in lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Component\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Connection Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc male connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMating Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConnects to 3300 NSv extension cable (330930) female coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eCorrect installation is necessary to prevent premature mechanical or electrical degradation of the proximity probe. Observe the following standard installation practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUse a #3 or larger tap drill when drilling and tapping a mounting hole for this 1\/4-28 probe.\u003c\/li\u003e\n  \u003cli\u003eEnsure the unthreaded length (0.0 in) matches the physical housing recess depth so the threads engage properly without binding.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the maximum case torque limit of 7.3 N m (65 in lb) during standard installation; recommended torque is 5.1 N m (45 in lb).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) on the coaxial cable to prevent internal conductor damage.\u003c\/li\u003e\n  \u003cli\u003eTo shield against electromagnetic fields and avoid cross-talk on small shafts, maintain a minimum separation of transducer tips of at least 25 mm (1.0 in) for axial position or 23 mm (0.9 in) for radial vibration measurements.\u003c\/li\u003e\n  \u003cli\u003eProtect the coaxial connector connection using connector protectors or silicone tape to prevent fluid ingress. Avoid silicone tape in direct turbine oil exposure environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis standard unarmored configuration (Option 00) is supplied without specific hazardous area approvals. It is intended for use in general-purpose industrial environments where explosive gas or dust atmospheres are not present.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610647403,"sku":"330901-00-19-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-19-10-02-00-3300-nsv-proximity-probes-xolgs1mwqgg_192bf11c-b3c7-4aad-98d3-d3daa30813c5.jpg?v=1765444137","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330901-00-19-10-02-00-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}