{"product_id":"bently-nevada-330901-00-90-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-90-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330901-00-90-10-02-05\u003c\/strong\u003e specifies a 3300 NSv proximity probe with a 1\/4-28 UNF thread and no armor. This specific configuration features 0.0 inches of unthreaded length, a 9.0-inch overall case length, a 1.0-meter (39 in) total cable length, a miniature coaxial ClickLoc connector with a standard cable, and multiple agency approvals.\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system is used for non-contact shaft vibration and position measurements on machines with limited clearance or reduced target geometries, such as centrifugal air compressors, refrigeration compressors, and small-bore rotating machinery. The unarmored cable design provides clean routing in tight enclosures, and the gold-plated ClickLoc connector prevents connection loosening during operation. It is electrically and mechanically interchangeable with older 3300 RAM systems, offering superior side-view characteristics and enhanced chemical resistance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThreaded configuration: 1\/4-28 UNF thread without stainless steel armor\u003c\/li\u003e\n\u003cli\u003eOption 00 unthreaded length: 0.0 inches (fully threaded case)\u003c\/li\u003e\n\u003cli\u003eOption 90 case length: 9.0 inches overall threaded length\u003c\/li\u003e\n\u003cli\u003eOption 10 total length: 1.0 meter (39 in) probe cable length\u003c\/li\u003e\n\u003cli\u003eOption 02 connector: Miniature coaxial ClickLoc connector on standard FEP insulated coaxial cable\u003c\/li\u003e\n\u003cli\u003eOption 05 approval: Multiple agency approvals for hazardous area installations\u003c\/li\u003e\n\u003cli\u003eTipLoc molding: Robust structural bond between the polyphenylene sulfide (PPS) tip and the stainless steel case\u003c\/li\u003e\n\u003cli\u003eCableLoc design: Provides up to 220 N (50 lb) of pull strength between the probe tip and the cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors and refrigeration compressors with tight clearances\u003c\/li\u003e\n\u003cli\u003eProcess gas compressors and high-speed turbomachinery\u003c\/li\u003e\n\u003cli\u003eRadial vibration and position measurements on shafts smaller than 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on flat targets smaller than 15 mm (0.6 in)\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and phase reference (Keyphasor) measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-90-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-90-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over ambient range (0 to 45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated standard probe cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature male coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe dc Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.2 +\/- 0.5 ohms (for 1.0 m total probe length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential pressure seal with Viton O-ring between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Calibration:\u003c\/strong\u003e The system is standard-calibrated to AISI 4140 steel. Calibrating to other target materials will alter the scale factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Mount the probe at the recommended gap of 1.0 mm (40 mils) from the target surface, corresponding to a nominal output of approximately -9 Vdc from the Proximitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Ensure the 75 ohm coaxial cable maintains a minimum bend radius of 25.4 mm (1.0 in) to prevent impedance changes and physical degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Torque:\u003c\/strong\u003e Secure the 1\/4-28 probe case using a maximum rated torque of 7.3 Nm (65 in-lb), with a recommended installation torque of 5.1 Nm (45 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Security:\u003c\/strong\u003e Hand-tighten the coaxial ClickLoc connectors. If environmental exposure to liquids is expected, protect the junction using a connector protector kit or self-fusing silicone tape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 05 Approvals:\u003c\/strong\u003e Approved for hazardous areas via multiple agencies (including CSA, ATEX, and IECEx certifications).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety (ia):\u003c\/strong\u003e Certified Ex ia IIC T5...T1 Ga and Ex ia IIIC T90degC...T280degC Dc when connected with appropriate entity parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sparking (nA\/ec):\u003c\/strong\u003e Certified Ex nA IIC T5...T1 Gc and Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Fully compliant with European EMC directive requirements for emissions and RFI\/EMI immunity when mounted appropriately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666543178091,"sku":"330901-00-90-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-90-10-02-05-3300-nsv-proximity-probes-wbnrvzeauz4_0bf6062b-6db8-41a8-b817-6fb849823731.jpg?v=1765440491","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330901-00-90-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}