{"product_id":"bently-nevada-330909-00-80-10-01-05-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330909-00-80-10-01-05 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330909-00-80-10-01-05\u003c\/strong\u003e is an eddy-current \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e developed by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for non-contacting machinery displacement and shaft vibration monitoring loops. This fractional-thread transducer operates as an integrated sensor input within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, which is specifically deployed in centrifugal air compressors, refrigeration compressors, and process gas compressors characterized by highly confined internal measurement footprints. By projecting a high-frequency radio frequency (RF) carrier field into the adjacent target area, the sensor continuously captures micro-gap transitions caused by surface-level eddy currents and relays this raw analog displacement wave back to a remote Proximitor module.\u003c\/p\u003e\n\u003cp\u003eThis specialized sensor is engineered for application zones where deep counterbores, severe sideview visibility constraints, or limited rear clearance prohibit the use of standard 5 mm or 8 mm proximity probe designs. The \u003cstrong\u003e330909-00-80-10-01-05\u003c\/strong\u003e configuration features a 3\/8-24 UNF fractional threaded steel casing integrated with an interlocking stainless steel armor sleeve to prevent physical pinching, shearing, and oil-induced outer insulation decay. It is calibrated to measure dynamic radial vibration on narrow shafts smaller than 51 mm (2 in) or axial thrust position on flat target surfaces smaller than 15 mm (0.6 in). Equipped with Multiple Agency Approvals under the corresponding configuration suffix, the probe provides continuous machinery asset protection when marshalled inside classified hazardous plant zones.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-profile transducer tip architecture engineered for tight machinery counterbores and restricted sideview clearance paths.\u003c\/li\u003e\n\u003cli\u003eRugged 3\/8-24 UNF fractional fully-threaded casing matched with an interlocking stainless steel armor wrap for severe mechanical wear protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated gold-plated brass ClickLoc miniature coaxial plug delivering a low-loss, vibration-proof positive locking wire link.\u003c\/li\u003e\n\u003cli\u003eHigh-stability sensor coil optimized to track small target areas, including micro-diameter rotating shafts under 51 mm.\u003c\/li\u003e\n\u003cli\u003eFull drop-in backward compatibility with legacy Bently Nevada 3300 RAM transducer systems and 190 series processing architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial shaft vibration and dynamic fluid-film bearing displacement tracking on industrial high-speed centrifugal compressors.\u003c\/li\u003e\n\u003cli\u003eDual-direction rotor axial thrust position offset capture inside compact turbo-expander gearboxes.\u003c\/li\u003e\n\u003cli\u003eRotating target speed detection, zero-speed confirmation, and Keyphasor phase reference signal generation in tight spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Profile \u0026amp; Exact Weight Formulas\u003c\/h3\u003e\n\u003cp\u003eIn high-integrity asset tracking, using non-specific box dimensions can cause mechanical fouling during bracket adjustment. Per official Bently Nevada 147385 datasheet technical constants, the physical geometry and cumulative dry mass metrics for this specific 1.0-meter fully threaded probe are precisely calculated below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Case Length (Option A):\u003c\/strong\u003e Exactly \u003cstrong\u003e0.0 inches (0 mm)\u003c\/strong\u003e indicating a fully threaded barrel profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length (Option B):\u003c\/strong\u003e Exactly \u003cstrong\u003e8.0 inches (203.2 mm)\u003c\/strong\u003e representing an extended-reach structural case length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded Case Section:\u003c\/strong\u003e Calculated as Overall Case Length minus Unthreaded Length (8.0 in - 0.0 in) = \u003cstrong\u003e8.0 inches (203.2 mm)\u003c\/strong\u003e of active 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Physical Cable Length (Option C):\u003c\/strong\u003e Exactly \u003cstrong\u003e1.0 meter (3.9 feet \/ 39 inches)\u003c\/strong\u003e measured from the probe tip face to the terminal coax joint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Mass Density of Armored Cable:\u003c\/strong\u003e Nominal \u003cstrong\u003e64 grams per meter (0.70 oz\/foot)\u003c\/strong\u003e driven by the heavy interlocking stainless steel armor skin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Probe Head and Long-Case Mass:\u003c\/strong\u003e Approximately \u003cstrong\u003e85 grams (3.00 oz)\u003c\/strong\u003e including the extended 8-inch AISI 304 stainless steel threaded shell, sensing coil, and transition hub assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Net Hardware Weight:\u003c\/strong\u003e Calculated as (64 g\/m x 1.0 m) + 85 g = \u003cstrong\u003e149 grams (5.26 oz)\u003c\/strong\u003e absolute net hardware weight per unit (excluding shipping boxes and the accompanying 9\/16-inch industrial lock nut).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330909\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003e0.0 in unthreaded section length (Fully threaded barrel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-80\u003c\/td\u003e\n\u003ctd\u003e8.0 in (203.2 mm) overall case length profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in) physical cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Connector\/Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (ATEX, IECEx, CSA, FM for hazardous zones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecise Engineering Data\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330909-00-80-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting Eddy-Current Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Mechanical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF fractional configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) nominal tracking window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scale Factor Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when integrated with NSv Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Nominal Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Case Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) absolute field bending constraint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLock Nut Size Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\/16-inch hex-face width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWrench Flat Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16-inch integrated flats on probe case body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreaded 3\/8-24 UNF Barrel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect physical adjustment interface into bracket mount or machine outer wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale coaxial terminal linking into the 3300 NSv extension cable path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Loop Matching:\u003c\/strong\u003e This 1.0-meter physical length probe \u003cstrong\u003emust\u003c\/strong\u003e be paired with a 4.0-meter extension cable to form a 5.0-meter total system loop, or a 6.0-meter extension cable to form a 7.0-meter total system loop. The total length must precisely match the electrical calibration length of the 3300 XL NSv Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Gap Adjustment:\u003c\/strong\u003e Manually thread the probe into the machine casing until the tip contacts the target surface, then back it out to the designated linear gap voltage threshold (typically -9.0 Vdc or central linear range) before tightening the 9\/16-inch lock nut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Ground Contacts:\u003c\/strong\u003e Ensure the miniature coaxial ClickLoc connector junction does not touch the metal walls of the junction box or conduit fittings. Wrap the connected union with self-fusing silicone tape to prevent electrical noise loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection Routing:\u003c\/strong\u003e The flexible stainless steel armor provides mechanical deflection protection; however, the probe lead wire should still be routed within dedicated low-voltage instrument trays to minimize exposure to high-voltage electromagnetic fields (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526171499,"sku":"330909-00-80-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330909-00-80-10-01-05-3300-nsv-proximity-probes-xm5pxmv1kah_010d5d42-1219-4ccf-8350-af7f9f1388e7.jpg?v=1765440280","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330909-00-80-10-01-05-3300-xl-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}