{"product_id":"el3201-beckhoff-ethercat-terminal-rtd-input-module","title":"EL3201 | BECKHOFF | EtherCAT Terminal RTD Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEL3201\u003c\/strong\u003e is a high-precision \u003cstrong\u003e1-channel analog input terminal\u003c\/strong\u003e by \u003cstrong\u003eBeckhoff\u003c\/strong\u003e designed for industrial temperature measurement. It supports a wide array of RTD sensors, including Pt and Ni types, as well as general resistance measurements. The module offers flexible connection technologies, supporting \u003cstrong\u003e2-, 3-, and 4-wire\u003c\/strong\u003e configurations to ensure accurate readings by compensating for lead resistance. With a resolution of \u003cstrong\u003e0.1 degC per digit\u003c\/strong\u003e and a robust digital filter, the \u003cstrong\u003eEL3201\u003c\/strong\u003e provides reliable thermal data for complex EtherCAT control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel RTD input with support for Pt and Ni sensors\u003c\/li\u003e\n\u003cli\u003eFlexible 2-, 3-, and 4-wire connection technologies\u003c\/li\u003e\n\u003cli\u003eHigh resolution of 0.1 degC per digit\u003c\/li\u003e\n\u003cli\u003eIntegrated digital filtering and limit value monitoring\u003c\/li\u003e\n\u003cli\u003eElectrical isolation of 500 V between E-bus and signal voltage\u003c\/li\u003e\n\u003cli\u003eCompact, DIN rail-mountable housing with status LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBeckhoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEL3201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Support\u003c\/td\u003e\n\u003ctd\u003ePt100\/200\/500\/1000, Ni100\/120\/1000, KTY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200 to +850 degC (Pt); -60 to +250 degC (Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degC per digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e24 ms (default), 4–500 ms (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ±0.5 degC (Pt sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (E-bus)\u003c\/td\u003e\n\u003ctd\u003eTyp. 190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e The terminal uses spring-loaded connections. For high-precision applications, a 4-wire connection is recommended to eliminate the impact of lead resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap onto a 35 mm DIN rail (EN 60715). Use the double slot and key connection for stable mechanical integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Ensure the module is kept within its IP20 environmental rating; avoid exposure to condensation or extreme dust\/moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e For installation in hazardous areas, ensure adherence to the ATEX rating (II 3 G Ex nA IIC T4 Gc).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE, UL\u003c\/li\u003e\n\u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003eEMC immunity\/emission: Conforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eVibration\/shock: Conforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106589106539,"sku":"EL3201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3201-nsupehl4xki.png?v=1776244458","url":"https:\/\/www.plcprotech.com\/tr\/products\/el3201-beckhoff-ethercat-terminal-rtd-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}