{"product_id":"emerson-pr6426-000-131-con041-916-200-eddy-current-sensor-system","title":"Emerson PR6426\/000-131 CON041\/916-200 Eddy Akım Sensör Sistemi","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR6426\/000-131\u003c\/strong\u003e non-contact eddy current sensor operates in combination with the \u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e signal converter to form a proximity measurement system for heavy industrial turbomachinery. Engineered for deployment on steam, gas, and hydro turbines, as well as compressors, pumps, and fans, this assembly measures radial and axial shaft displacement, position, eccentricity, and motion. The \u003cstrong\u003ePR6426\/000-131\u003c\/strong\u003e sensor monitors physical shaft proximity without direct contact, while the \u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e converter processes these variables into normalized electrical outputs suitable for continuous machinery protection networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement mechanism for detailed shaft dynamics and displacement tracking \u003c\/li\u003e\n\u003cli\u003eHigh-pressure durability with a sensor head rated to withstand up to 6,500 hpa \u003c\/li\u003e\n\u003cli\u003eExtended measurement range up to 20.0mm when paired with the designated configuration converter \u003c\/li\u003e\n\u003cli\u003eRugged physical construction featuring a stainless steel sleeve and high-temperature PTFE cable insulation \u003c\/li\u003e\n\u003cli\u003eFast loop processing execution defined by a signal rise time under 15 microseconds \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft dynamic displacement logging \u003c\/li\u003e\n\u003cli\u003eIndustrial turbomachinery position, motion, and eccentricity monitoring \u003c\/li\u003e\n\u003cli\u003eMachinery protection monitoring across turbines, compressors, and large industrial fans \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePR6426\u003c\/td\u003e\n\u003ctd\u003e20.0mm (Extended Range)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.5% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eDynamic \u0026amp; Performance Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003e2 V\/mm (50.8 mV\/mil) \u0026lt;= +\/-1.5% max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap (Center)\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.5 mm (0.22\") Nominal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surface Speed\u003c\/td\u003e\n\u003ctd\u003e2,500 m\/s (98,425 ips) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget \/ Surface Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel (42 Cr Mo 4 Standard) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 200 mm (7.87\") \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-24V Configuration)\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output Range: -4V to -20V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-2V Configuration)\u003c\/td\u003e\n\u003ctd\u003e-21V to -32V (Output Range: -2V to -18V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 degC (-22 to 212 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-35 to 175 degC (-31 to 347 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Temperature Excursions (\u0026lt;4 Hours)\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Shock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Shock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g (49.05 m\/s2) @ 60Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Protection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Housing Material\u003c\/td\u003e\n\u003ctd\u003ePA 6.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Weight\u003c\/td\u003e\n\u003ctd\u003e~60 grams (2.12 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sleeve Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Cable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Weight (with 1M Cable, No Armor)\u003c\/td\u003e\n\u003ctd\u003e~800 grams (28.22 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input Connection\u003c\/td\u003e\n\u003ctd\u003eSelf-Locking Lemo-Plug \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply \/ Output Connection\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Type (Max. 1.5mm2, wire-end sleeves) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the signal converter module on a standard DIN rail carrier inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain a clear zone of at least 80 mm diameter free of ferrous material around the 32mm sensor head to avoid field distortion.\u003c\/li\u003e\n\u003cli\u003eObserve a minimum cable bending radius of 35 mm for armored cable paths, or 25 mm for non-armored variants.\u003c\/li\u003e\n\u003cli\u003eCalibrate the initial sensor position to a nominal center air gap of approximately 5.5 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU (DIN EN 50581) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e EN 60079-0, EN 60079-11; II 2 G Ex ia IIC T4 Gb (-20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e IEC 60079-0, IEC 60079-11, IEC 60079-26; Ex ia IIC T4 Gb (-20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CAN\/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN\/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04; ANSI\/UL Standard 913-2004, ANSI\/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Entry:\u003c\/strong\u003e Intrinsic Safety (Ex ia IIC T4 Gb \/ Class I Division 1 Groups A, B, C, D T4); Non-sparking (Class I Division 2 Groups A, B, C, D \/ Ex nA II T3..T4 \/ AEx nA II T3..T4) \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695410770283,"sku":"PR6426\/000-131 CON041\/916-200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6426-000-131-con041-916-200-eddy-current-sensor-s3qmn1mgkux.jpg?v=1766052953","url":"https:\/\/www.plcprotech.com\/tr\/products\/emerson-pr6426-000-131-con041-916-200-eddy-current-sensor-system","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}