{"product_id":"general-electric-is220ptcch1a-mark-vie-ptcc-thermocouple-input-module","title":"General Electric IS220PTCCH1A Mark VIe PTCC Thermocouple Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PTCCH1A\u003c\/strong\u003e is a thermocouple input module manufactured by General Electric as part of the Mark VIe Control System product family. This specialized assembly provides an engineering interface for temperature monitoring functions, accepting standardized thermocouple sensor types and millivolt inputs. Structurally consisting of an internally positioned BPPx processor board and a dedicated thermocouple acquisition board, the \u003cstrong\u003eIS220PTCCH1A\u003c\/strong\u003e processes inputs across simplex, duplex, or Triple Modular Redundant (TMR) control architectures. The pack is engineered to condition signals over long cable lengths directly from the turbine panel, incorporating voltage suppression and limitation hardware components alongside high\/low software limit checks to protect internal processing units against fault conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcesses specialized direct temperature readings across multiple standard thermocouple styles\u003c\/li\u003e\n\u003cli\u003eFormulated as a functional A-rated revision to optimize basic performance specifications\u003c\/li\u003e\n\u003cli\u003eContains one dedicated BPPx processor board and one thermocouple acquisition board inside a single assembly\u003c\/li\u003e\n\u003cli\u003eSupports versatile infrastructure scaling across simplex, duplex, and TMR multi-channel configurations\u003c\/li\u003e\n\u003cli\u003eAllows extensive field-wire separation distance directly from the core turbine control panels\u003c\/li\u003e\n\u003cli\u003eImplements robust hardware and software filtering to ensure superior common-mode and normal-mode noise rejection\u003c\/li\u003e\n\u003cli\u003eExecutes continuous hardware diagnostic testing, including flash memory, RAM, and internal power checks\u003c\/li\u003e\n\u003cli\u003eUtilizes standardized series-limiting resistors, capacitors, transistors, and diodes for built-in voltage suppression\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas, steam, and hydro turbine exhaust gas temperature (EGT) monitoring\u003c\/li\u003e\n\u003cli\u003eMulti-channel industrial thermal profiling\u003c\/li\u003e\n\u003cli\u003eCritical process loop temperature acquisition in TMR automation setups\u003c\/li\u003e\n\u003cli\u003ePower generation automated drive thermal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIS220PTCCH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMark VIe Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003ePTCC Thermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eIS220 Special Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity (1 Pack)\u003c\/td\u003e\n\u003ctd\u003e12 Thermocouple Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity (2 Packs)\u003c\/td\u003e\n\u003ctd\u003e24 Thermocouple Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eE, J, K, S, and T (Grounded or Un-grounded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMillivolt (mV) Input Span\u003c\/td\u003e\n\u003ctd\u003e-8 to 45 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Software\/Conformity Error\u003c\/td\u003e\n\u003ctd\u003e0.25 degrees Fahrenheit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e±5 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Common-Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e100 dB @ 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e250 mV RMS @ 50\/60 Hz (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowed Cable Resistance\u003c\/td\u003e\n\u003ctd\u003e450 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Panel Distance\u003c\/td\u003e\n\u003ctd\u003e984 feet (300 meters) from turbine I\/O panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Conditions\u003c\/td\u003e\n\u003ctd\u003e-22 to +149 Fahrenheit (-30 to +65 Celsius)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd\u003eGEH-6721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 x 12 x 12 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance and Resistance Limits:\u003c\/strong\u003e The module can be situated up to 984 feet (300 meters) away from the main turbine I\/O panel, provided that total field cable loop resistance does not exceed a maximum of 450 Ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Versatility:\u003c\/strong\u003e E, J, K, S, and T standard thermocouple types can be deployed in either grounded or un-grounded structural wiring configurations based on site shielding protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Structuring:\u003c\/strong\u003e For basic simplex operations, deploy a single pack to receive up to 12 inputs; dual packs expand standard capability to 24 inputs, while three units are required for voted TMR configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Up Verification:\u003c\/strong\u003e Upon applying system power, the module performs automated power-up self-tests of its flash memory, RAM, hardware components, and Ethernet communication ports before entering active state tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415587179,"sku":"IS220PTCCH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220ptcch1a-thermocouple-input-module-hcljcxqsbzt_973610e8-5931-47ef-a29a-de216306bdba.jpg?v=1766135235","url":"https:\/\/www.plcprotech.com\/tr\/products\/general-electric-is220ptcch1a-mark-vie-ptcc-thermocouple-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}