{"product_id":"honeywell-51196655-100-tdc-3000-power-supply-module","title":"Honeywell 51196655-100 TDC 3000 Güç Kaynağı Modülü","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eReliable DC system power within legacy distributed control networks is maintained by the Honeywell 51196655-100, a robust chassis-mounted Power Supply Module engineered for integration with the Honeywell TDC 3000 DCS architecture. This assembly provides regulated operating voltages directly to local node backplanes, ensuring continuous operation of critical control cards, network interfaces, and processor modules. The unit features built-in overcurrent protection and configurable clock reference settings to support precise hardware synchronization across distributed nodes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Clock Sync Support:\u003c\/strong\u003e Features board jumper \u003cstrong\u003eJ102\u003c\/strong\u003e for manual switching between Internal (line frequency) and External clock operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e Overvoltage, short-circuit, and thermal protection safeguards downstream backplane components.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Heat Dissipation:\u003c\/strong\u003e Built with high-surface-area heat sinks to enable continuous operation in enclosed control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Plug-In Design:\u003c\/strong\u003e Rugged form factor with high-reliability rear pin connectors for direct insertion into TDC 3000 card cages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTDC 3000 Nodes:\u003c\/strong\u003e Clean power delivery for Network Interface Modules (NIM) and Local Control Network (LCN) architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefining and Petrochemical Processing:\u003c\/strong\u003e High-availability process automation power systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSequence of Events (SOE) Systems:\u003c\/strong\u003e Clock-synchronized field event logging installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 12px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 12px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e51196655-100\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eTDC 3000 Distributed Control System (DCS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eClock Reference Selector\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eJumper J102 (INT \/ EXT options)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eDefault Clock Jumper Setting\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eINT (Internal line frequency)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eTDC 3000 System Card Cage Slot\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e3.0 kg (6.61 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e320 mm x 240 mm x 110 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 12px; font-weight: bold;\"\u003eTerminal \/ Component\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 12px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eJumper J102 (INT position)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003ePins configured for Internal Line Frequency Clock (standard DCS nodes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eJumper J102 (EXT position)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003ePins configured for External System Clock (required for SOE NIM setups)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eRear Edge Connector Pinout\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eDedicated power backplane interface with heavy-duty DC supply pins\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis module serves as a direct drop-in replacement for legacy TDC 3000 card-file power configurations. When swapping power supplies, verify that the module's revision matches the backplane grounding scheme of your existing card rack to prevent potential ground loop disturbances.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBy default, all replacement 51196655-100 power supplies are shipped from stock with jumper \u003cstrong\u003eJ102\u003c\/strong\u003e pinned to the Internal (INT) position. This is suitable for general nodes. If your architecture relies on Sequence of Events (SOE) tracking, the Clock Master, Clock Slave, and Network Interface Modules (NIMs) with specific SOE requirements must be verified and manual adjustments made to external clock configurations.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways check the physical state of the \u003cstrong\u003eJ102\u003c\/strong\u003e jumper header before sliding the module into the chassis guide rails. If the clock mode is mismatched relative to neighboring nodes, it can lead to synchronization dropouts or network time stamps showing system fault codes during high-traffic intervals.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all primary AC\/DC power sources feeding the card cage before attempting to insert or remove this power supply module. Live insertion of power cards can result in high-voltage arcing on the backplane, causing permanent physical damage to adjacent process control processors or interface cards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 10px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; margin-right: 10px; font-weight: bold; font-size: 14px;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the source power to the specific card-cage section has been shut down and locked out.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; margin-right: 10px; font-weight: bold; font-size: 14px;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eCheck and position the \u003cstrong\u003eJ102\u003c\/strong\u003e configuration jumper for either \u003cstrong\u003eINT\u003c\/strong\u003e or \u003cstrong\u003eEXT\u003c\/strong\u003e clock operations to align with your facility's system layout.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; margin-right: 10px; font-weight: bold; font-size: 14px;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the PCB edges carefully with the card guides inside the TDC 3000 rack enclosure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; margin-right: 10px; font-weight: bold; font-size: 14px;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eGently but firmly push the module straight back until the rear connectors fully engage with the backplane receptacle, then tighten any locking mechanism or chassis retention screws.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679383613803,"sku":"51196655-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51196655-100-zxesryfhkuw_90321403-bd03-43fd-957d-3878415b8bd8.jpg?v=1765958306","url":"https:\/\/www.plcprotech.com\/tr\/products\/honeywell-51196655-100-tdc-3000-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}