{"product_id":"honeywell-900h02-0202-hc900-digital-output-module","title":"Honeywell 900H02-0202 HC900 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating precise actuator and solenoid control within process environments, the \u003cstrong\u003eHoneywell 900H02-0202\u003c\/strong\u003e functions as a highly reliable 16-channel digital output module designed for integration with the \u003cstrong\u003eHC900\u003c\/strong\u003e controller platform. This sourcing output module interfaces the digital control logic of the controller with field-level devices like indicators, interlocks, and control relays, ensuring high-density switching capabilities and robust isolation from external electrical disturbances.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.3rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Output Channel Array:\u003c\/strong\u003e Provides 16 independent digital output points for efficient utilization of controller rack space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSourcing Configuration:\u003c\/strong\u003e Outputs function as sourcing channels, switching the positive leg of the external 24VDC power supply to the field loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Optical isolation protects internal system-side electronics from external field-side noise and voltage transients.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Diagnostics:\u003c\/strong\u003e Individual status LEDs located on the front panel provide real-time visual confirmation of each output state.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable Operation:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP) for rapid maintenance without disabling the controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.3rem;\"\u003eTypical Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Solenoid Valves:\u003c\/strong\u003e Actuation of pneumatic or hydraulic valves in process networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Starter Controls:\u003c\/strong\u003e Driving contactors and control relays in Motor Control Centers (MCCs).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnnuciator Systems:\u003c\/strong\u003e Activating local visual and audible alarm systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterlock Integration:\u003c\/strong\u003e Transmitting binary states to external hardwired safety and control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.3rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e900H02-0202\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHC900 Process Controller System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e16 Points (Sourcing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e18 VDC to 30 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Current per Channel\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Module Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8.0 A (subject to thermal derating)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eGalvanic Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eField to Logic: Optical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eModule-dependent based on load current\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRequired Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20-pin terminal connector (sold separately)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24.0 cm x 14.5 cm x 4.8 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.3rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The 900H02-0202 is backwards-compatible across older HC900 hardware environments. Ensure the host controller’s firmware version aligns with the I\/O configuration software module database before adding this hardware definition to your project file.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Because the channels are in a sourcing format, the external 24VDC load power supply must share a common reference ground with the system. For heavy inductive loads (such as DC motor contactors or large solenoid coils), it is mandatory to wire external freewheeling diodes directly across the load terminals to prevent high-voltage transient spikes from degrading the output transistors over time.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003e\u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e Utilize high-quality twisted, shielded control cable for runs exceeding 100 meters to minimize electromagnetic interference. Tighten the 20-pin terminal block mounting screws to the correct torque specification to guarantee electrical integrity under high vibration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.3rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting hardware installation, replacement, or service, ensure that all main power and external auxiliary field-side power sources are fully locked out and de-energized. Verify that there is no residual energy present in the field wiring to prevent electrical shock or hardware destruction.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.8rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAlign the keying tabs of the 900H02-0202 module with the dedicated slot guides of the HC900 backplane rack.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.8rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the module firmly back into the slot until the backplane connectors seat completely and the top and bottom retention tabs snap shut.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.8rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWire the external 24VDC field power supply and corresponding output loads to the matching 20-pin terminal block, then secure the block onto the module connector.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705553252715,"sku":"900H02-0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900h02-0202-p1p5mgtnw2d_0cac549b-92e7-4c74-8160-7e0c0a39fd67.jpg?v=1766649516","url":"https:\/\/www.plcprotech.com\/tr\/products\/honeywell-900h02-0202-hc900-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}