{"product_id":"honeywell-experion-pks-8c-pcnt02-c300-control-processor","title":"Honeywell Experion PKS 8C-PCNT02 C300 Kontrol İşlemcisi","description":"\u003ch3\u003eÜrün Genel Bakış\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-486\"\u003eHoneywell Experion PKS (Process Knowledge System) Seri 8 donanım platformunun yüksek performanslı merkezi olan \u003cstrong\u003e8C-PCNT02 (8CPCNT02)\u003c\/strong\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-485\"\u003eGelişmiş bir \u003cstrong\u003eC300 Kontrol İşlemcisi\u003c\/strong\u003e olarak, bu birim karmaşık kontrol stratejilerini, parti işlemlerini ve hızlı mantık gereksinimlerini mutlak kesinlikle yürütmek üzere tasarlanmıştır.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-484\"\u003eFabrika uygulamalı konformal kaplamasıyla ayırt edilen \u003cstrong\u003e8C-PCNT02\u003c\/strong\u003e, korozyona karşı üstün koruma sağlar ve G3 seviyesindeki ortam koşullarına dayanıklıdır.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDikey montaj için tasarlanmış olup, kabin alanını maksimize eder ve termal konveksiyonu artırır. Bu kontrolör, binlerce G\/Ç noktasını yönetirken insan-makine arayüzü (HMI) ve diğer eş kontrolörlerle yüksek hızlı iletişimi sürdürür. LNG terminalleri, büyük ölçekli rafineriler ve ilaç fabrikaları gibi küresel endüstriler için tek bir saniyelik duruşun önemli finansal kayıplara yol açtığı durumlarda kesin tercihtir.\u003c\/p\u003e\n\u003ch3\u003eTeknik Konfigürasyon\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-483\"\u003e\u003cstrong\u003e8C-PCNT02\u003c\/strong\u003e mimarisi, sistem genelinde güvenilirlik ve veri bütünlüğüne odaklanan modüler ve sağlam bir tasarım kullanır.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministik Yürütme Ortamı (CEE)\u003c\/strong\u003e: Karmaşık Fonksiyon Blok Diyagramları (FBD) ve Ardışık Fonksiyon Şemalarının (SFC) seçilebilir alt saniye aralıklarında yürütülmesini destekler.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTasarımla Yedeklilik\u003c\/strong\u003e: İkinci bir modül ve yedekleme kablosu ile eşleştirildiğinde, 8C-PCNT02 kesintisiz ve \"sorunsuz\" geçiş sağlayarak donanım arızası sırasında kontrolün devam etmesini garanti eder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGelişmiş Bağlantı\u003c\/strong\u003e: Seri 8 G\/Ç modülleri ile iletişim için çift yedekli G\/Ç Bağlantı portları ve yüksek güvenlikli ağ entegrasyonu için çift FTE (Hata Toleranslı Ethernet) portları içerir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Konformal Kaplama\u003c\/strong\u003e: Özellikle sert kimyasal atmosferlere (H2S, Cl2, SO2) dayanacak şekilde işlenmiş olup, işlemcinin korozyona maruz kalan endüstriyel bölgelerdeki ömrünü uzatır.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDikey Form Faktörü\u003c\/strong\u003e: Seri 8 \"Slim\" profilinin bir parçası olarak, basitleştirilmiş kablolama ve modül değişimi için özel bir C300 IOTA (Giriş Çıkış Sonlandırma Montajı) üzerine monte edilir.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTeknik Özellikler\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eÖzellik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpesifikasyon\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarka\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeri\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Seri 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eİşlemci Tipi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300 Kontrolör\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eÇevre Koruması\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG3 Konformal Kaplamalı\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHafıza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStrateji depolama için uçucu olmayan flash bellek\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eÇalışma Sıcaklığı\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ila +70 Santigrat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGüç Girişi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (IOTA üzerinden)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYedeklilik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDestekleniyor (Donanım \u0026amp; Yazılım)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAğırlık\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85 kg (Net) \/ 3.0 kg (Nakliye)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandartlar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, FM Class I Div 2, ATEX Bölge 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTeknik SSS\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e8C-PCNT01 ile 8C-PCNT02 arasındaki temel fark nedir?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e8C-PCNT02, genellikle optimize edilmiş bellek yönetimi ve daha yüksek işlem hızı sunan modernleştirilmiş donanım revizyonudur; bu sayede daha büyük kontrol stratejilerini ve daha yüksek sürüm Experion PKS yazılımlarını destekler.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBu işlemci program yedeği için pil gerektirir mi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-480 citation-end-480\"\u003e8C-PCNT02, yüksek hızlı uçucu olmayan RAM ve flash bellek kullanır.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e Eski modellerde pil destekli RAM modülü kullanılırken, modern C300 birimleri kontrol stratejisini tam güç kaybında flash bellekte tutacak şekilde tasarlanmıştır.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAynı rafta kaplamalı ve kaplamasız modülleri karıştırabilir miyim?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTeknik olarak mümkün olsa da, G3 koruması gereken ortamlar için önerilmez. İşlemci kaplamalıysa (8C-PCNT02), ilgili IOTA ve G\/Ç modüllerinin de kaplamalı olması gerekir; böylece tüm kontrol döngüsü korozyona karşı korunmuş olur.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMühendislik ve Kurulum Kılavuzu\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Montajı:\u003c\/strong\u003e 8C-PCNT02, bir C300 IOTA (örneğin 8C-TCNTA1) üzerine monte edilmelidir. IOTA üzerindeki topraklama kulaklarının tesisin topraklama sistemine sağlam şekilde bağlandığından emin olun. Zayıf topraklama, FTE iletişim hatalarına ve G\/Ç noktalarında \"kötü kalite\" durumuna yol açabilir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFTE Ağ Bütünlüğü:\u003c\/strong\u003e Hata Toleranslı Ethernet (FTE) kabloları bağlanırken \"Sarı\" ve \"Yeşil\" kabloların yer değiştirmediğinden emin olun. C300, ağ yollarını belirlemek için belirli port mantığı kullanır; bu kabloların karışması Experion Sistem Durum Ekranında \"İkincil Ağ Arızası\" alarmına neden olabilir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermal Yönetim:\u003c\/strong\u003e Seri 8 kontrolörler soğutma için doğal dikey konveksiyona dayanır. Kontrolör sırasının üstünde ve altında en az 150 mm boşluk bırakın. Yüksek yoğunluklu kabinlerde, işlemcinin hız düşürmesini önlemek için iç ortam sıcaklığını 70 Santigratın altında tutmak amacıyla kabin fanı kullanılması önerilir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679341932907,"sku":"8C-PCNT02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8c-pcnt02-mzbnuuokt4d_95e66450-a71c-4412-a9e9-8ba4b8f2b1d1.jpg?v=1765958219","url":"https:\/\/www.plcprotech.com\/tr\/products\/honeywell-experion-pks-8c-pcnt02-c300-control-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}