{"product_id":"ic694mdl754-ge-fanuc-pacsystems-rx3i-32-point-sourcing-output-module","title":"IC694MDL754 GE Fanuc PACSystems RX3i 32 Noktalı Kaynaklı Çıkış Modülü","description":"\u003ch3\u003eÜrün Genel Bakışı\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-527\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-527\"\u003eÜrün \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-527\"\u003eIC694MDL754 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-527\"\u003e GE Fanuc PACSystems RX3i platformu için yerel olarak tasarlanmış yüksek yoğunluklu, akıllı katı hal yanıt modülüdür\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-527 citation-end-527\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-526\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e12\/24 VDC Pozitif Mantık Çıkış Modülü olarak çalışır \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-526 citation-end-526\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-525\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBu kart, yerel gücü 32 ayrı çıkış noktasına yönlendirerek gerçek zamanlı eylem gerçekleştirmeyi sağlar\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-525 citation-end-525\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAğır otomasyon sistemleri—güç dağıtım şebekeleri, otomatik işleme hatları ve kimyasal karışım kompleksleri dahil—\u003cstrong\u003eIC694MDL754\u003c\/strong\u003e modülüne, solenoid valfler, harici kontaktörler ve gösterge lambaları gibi alt donanım bileşenlerini yönetme görevini verir. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-524\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e32 ayrı noktayı iki tam izole edilmiş 16 kanallı gruba ayırarak, modül tesis mühendislerinin tek bir arka plan üzerinde karışık voltaj seviyeleri çalıştırmasına olanak tanır\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-524 citation-end-524\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-523\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eEntegre Elektronik Kısa Devre Koruması (ESCP) ve aşırı sıcaklık tanı sistemleri, devre sağlığını aktif olarak izler, ciddi toprak kısa devrelerini otomatik olarak tespit eder ve saha anormalliklerini izole ederek uzun süreli tesis zorunlu duruşlarını önler\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-523 citation-end-523\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMimari Düzen \u0026amp; Tanısal Özellikler\u003c\/h3\u003e\n\u003cp\u003eDonanım yapısı ve tanısal işlemler, \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL754\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e mantık çıkış modülünün dinamik saha ağları arasında istikrarlı bileşen koordinasyonunu sağlar.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-522\"\u003eÇift Gruplu Kaynak Mimarisi:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-522\"\u003e 32 çıkış kanalını iki ayrı elektriksel blok halinde, her biri 16 yol olmak üzere böler\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-522 citation-end-522\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-521\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHer grup bağımsız ortak bir hat tutar, böylece Grup 1 12 VDC yükleri kontrol ederken Grup 2 aynı anda tek kanalda maksimum 0,75 Amper'e kadar 24 VDC yükleri yönetir\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-521 citation-end-521\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-520\"\u003eKendi Kendini Kurtaran ESCP Devresi:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-520\"\u003e Her bir noktada aktif elektronik aşırı akım, termal aşırı yük ve kısa devre koruması özelliklerine sahiptir\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-520 citation-end-520\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-519\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAltta yatan fiziksel hat arızası veya termal aşırı yük durumu ortadan kalktığında, sürücü sert bir CPU sıfırlaması gerektirmeden çıkışı otomatik olarak aktif çalışma durumuna geri döndürür\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-519 citation-end-519\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-518\"\u003eDonanım Çıkış Varsayılan Matrisi:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-518\"\u003e Sistem geri dönüş işlemlerini yönetmek için arka kasa üzerinde bulunan entegre çift DIP anahtar dizisini içerir\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-518 citation-end-518\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-517\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eTeknisyenler, modülü yerel iletişim arızası sırasında ya Kapalı Kalma ya da Son Durumu Tutma moduna ayarlayabilir\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-517 citation-end-517\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"citation-516\"\u003eKapsamlı Tanısal Haritalama:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-516\"\u003e Bireysel nokta arızalarını, harici saha tarafı güç kaybı alarmlarını, mekanik terminal bloğu varlık takibini ve DIP anahtarı yapılandırma uyumsuzluğu kayıtlarını raporlayarak net durum kodlarını çekirdek RX3i işlem birimine iletir\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-516 citation-end-516\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformans Verileri ve Teknik Özellikler\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMühendislik Ölçütü\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFabrika Belgesi Spesifikasyonu\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Tanımı\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC694MDL754\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarka Üretici\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (PACSystems RX3i Serisi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModül Sınıflandırması\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-515\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eÇıkış Modülü, 12\/24VDC, 0.75A, 32 Noktalı Gruplandırılmış, ESCP ile\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-515 citation-end-515\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eÇıkış Tipi Lojik\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-514\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eKaynak Tipi \/ Pozitif Lojik (Yükün pozitif tarafını anahtarlıyor)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-514 citation-end-514\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eÇıkış Gerilim Aralığı\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-513\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e10.2 ila 30 VDC\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-513 citation-end-513\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eToplam Nokta Kapasitesi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-512\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e32 Çıkış (Her biri 16 kanallı iki izole grup)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-512 citation-end-512\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksimum Çıkış Akımı\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-511\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eNokta başına maksimum 0.75 Amper\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-511 citation-end-511\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSabit Durum Aşırı Akım Kesmesi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-510\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eNokta başına tipik 5 Amper\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-510 citation-end-510\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksimum Başlangıç Akımı\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-509\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eESCP kesmesini tetiklemeden 10 ms boyunca 3 Amper sağlanır\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-509 citation-end-509\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKanal Tepki Hızları\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-508\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAçma Tepkisi: maksimum 0.5 ms \/ Kapama Tepkisi: maksimum 0.5 ms\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-508 citation-end-508\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiyelektrik İzolasyon Derecesi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e250 VAC sürekli; \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-507\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1500 VAC 1 dakika (Saha - Arka Panel \u0026 Grup - Grup arası)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-507 citation-end-507\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArka Panel Güç Tüketimi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-506\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDahili 5 VDC lojik hattından maksimum 300 mA\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-506 citation-end-506\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModül Tanımlama Kaydı\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-505\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e0x059h tahsis kayıt defteri\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-505 citation-end-505\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUyumlu Terminal Blokları\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"citation-504\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eKutu tipi (IC694TBB032) veya Yay tipi (IC694TBS032)\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-504 citation-end-504\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDonanım Yaşam Döngüsü ve Sorun Giderme SSS\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC694MDL754 ön göstergeleri, normal çalışma koşulları ile canlı döngü arızaları arasında nasıl ayrım yapar?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-503\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eModül, özel durum göstergeleriyle eşleştirilmiş 32 yeşil\/sarı kanal durum LED'ini entegre eder\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-503 citation-end-503\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-502\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBir kanal LED'i, çıkış devresi açık ve normal çalışıyorsa sabit yeşil yanar\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-502 citation-end-502\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-501\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAşırı akım veya kısa devre oluşursa, ilgili kanal LED'i sabit sarı renge döner\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-501 citation-end-501\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-500\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAyrıca, izole edilmiş bankadaki herhangi bir nokta arızası tespit edilirse grup alanı güç LED'leri sarı yanar\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-500 citation-end-500\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHold Last State (Son Durumu Tut) olarak yapılandırılmış eski bir IC694MDL754 versiyonu (–CC veya daha eski) tam bir raf güç kesintisi yaşadığında ne olur?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-499\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1.20'den önceki firmware sürümlerinde (–CC ve daha eski kartlarda bulunan), raf gücü kesilip sonra geri verildiğinde, modülün çıkışları son durumlarını korur ancak başlatma sırasında 800 ms'ye kadar anlık olarak KAPALI duruma düşer\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-499 citation-end-499\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-498\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBu kesinti, CPU'nun RUN moduna geri geçişinden önce gerçekleşir\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-498 citation-end-498\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-497\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBu anlık kesintiyi ortadan kaldırmak için, modül yetkili bir flash aracı kullanılarak 1.20 sürüm numaralı firmware'e yükseltilmelidir\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-497 citation-end-497\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIC694MDL754 modülünü sınıflandırılmış tehlikeli bir alanda çalışırken sıcak değişim yapmak güvenli midir?\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-496\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eHayır. Modül, Sınıf I, Bölüm 2, A, B, C ve D Gruplarında kullanım için sertifikalı olsa da, katı bir patlama uyarısı geçerlidir.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-496 citation-end-496\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-495\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eTeknisyenler, modülleri değiştirmeden, kablolamadan veya ellemeden önce birincil sistem gücünü tamamen kesmeli veya çevre ortamın kesinlikle tehlikesiz olduğundan emin olmalıdır; aksi takdirde statik kıvılcım ateşlemesi riski vardır.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-495 citation-end-495\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSaha Mühendisliği ve Kurulum Protokolü\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTermal Düşürme ve Ortam Sınırları:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-494\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eÇıkış kartını standart 24 VDC yük profiliyle çalıştırırken, tüm 32 kanal maksimum 60 °C ortam sınırına kadar sürekli olarak enerjili kalabilir ve termal sorun yaşamaz.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-494 citation-end-494\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-493\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAncak, saha besleme voltajı 30 VDC'ye yükseltilirse, 42 °C üzerindeki sıcaklıklarda sıkı bir termal düşürme eğrisi uygulanır.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-493 citation-end-493\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-492\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e30 VDC ve maksimum 60 °C ortam sıcaklığında, otomatik termal kapanmayı önlemek için sistem yük yapılandırmasını en fazla 12 eşzamanlı aktif çıkışla sınırlandırmalısınız.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-492 citation-end-492\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDIP Anahtarı Senkronizasyon Standartları:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-491\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eDonanım çıkışlarının varsayılan DIP anahtarı montajı modül muhafazasının arka yüzünde bulunur ve modül tamamen arka panelden çıkarıldığında ayarlanabilir.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-491 citation-end-491\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-490\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eAnahtarı sağa (açık) hareket ettirmek Zorla Kapama parametresini uygular, sola (kapalı) hareket ettirmek ise Son Durumu Tut seçeneğini belirler.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-490 citation-end-490\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-489\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBu fiziksel donanım anahtarının konumu, RX3i programlama platformunda yapılandırılan yazılım özellikleriyle tam olarak eşleşmelidir. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-489 citation-end-489\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-488\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e; varlık uyumsuzluğu bir yapılandırma hatası oluşturur ve modül başlatmasını durdurur.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-488 citation-end-488\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAkım Kaynağı Gücü ve Ortak Bağlantılar:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-487\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e36 pinli düzenekle saha cihazları bağlanırken, her izole 16 kanallı grup için ayrı güç kaynağı bağlantıları sağlanmalıdır.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-487 citation-end-487\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-486\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e1–16 kanallarının harici pozitif beslemesini Terminal 17'ye, karşılık gelen negatif dönüş hattını ise Terminal 18'e bağlayın.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-486 citation-end-486\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-485\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e17–32 kanallarının pozitif beslemesini Terminal 35'e, negatif dönüş hattını ise Terminal 36'ya bağlayın.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-485 citation-end-485\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-484\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003eBu bağımsız grup beslemelerini, ayrı güç kaynaklarıyla çalışıyorlarsa tek bir ortak döngüye bağlamayın, çünkü bu modülün 250 VAC grup-grup optik güvenlik izolasyonunu geçersiz kılar.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"citation-484 citation-end-484\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408116075,"sku":"IC694MDL754","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic694mdl754-discrete-output-module-vifwxlfevqt_5a715998-e1aa-4237-950c-62c13b5e2763.jpg?v=1766134958","url":"https:\/\/www.plcprotech.com\/tr\/products\/ic694mdl754-ge-fanuc-pacsystems-rx3i-32-point-sourcing-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}