{"product_id":"mitsubishi-electric-fr-f840-00470-2-60-fr-f800-energy-saving-inverter","title":"Mitsubishi Electric FR-F840-00470-2-60 FR-F800 Energy-Saving Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for optimized fluid control and fan applications, the \u003cstrong\u003eFR-F840-00470-2-60\u003c\/strong\u003e functions as a high-efficiency \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e (VFD) within the Mitsubishi Electric FR-F800 family. This energy-saving inverter is tailored for heavy-duty industrial systems, offering precise speed control and advanced motor tuning capabilities to minimize energy consumption in pump, compressor, and HVAC applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a dual-rating structure, allowing engineers to configure the device for Super Light Duty (SLD) or Light Duty (LD) operation depending on system load profiles. Built-in mechanisms handle significant input voltage fluctuations, securing operational continuity in environments with unstable grid infrastructure. Comprehensive protection circuits guard against overload conditions, assuring maximum uptime for critical mechanical operations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-rating architecture supporting Super Light Duty (SLD) and Light Duty (LD) parameters.\u003c\/li\u003e\n  \u003cli\u003eAdvanced energy-saving algorithms that dynamically optimize motor excitation currents.\u003c\/li\u003e\n  \u003cli\u003eRobust toleration of input line voltage fluctuations.\u003c\/li\u003e\n  \u003cli\u003eInverse-time overload characteristic profiles tailored for distinct ambient operating temperatures.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic features to monitor thermal state and component degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial ventilation systems and cooling tower fans.\u003c\/li\u003e\n  \u003cli\u003eMunicipal water distribution and wastewater pump systems.\u003c\/li\u003e\n  \u003cli\u003eScrew compressors and pneumatic material handling setups.\u003c\/li\u003e\n  \u003cli\u003eLarge-scale commercial HVAC air handling units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth\u003eManufacturer\u003c\/th\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePart Number \/ Model\u003c\/th\u003e\n      \u003ctd\u003eFR-F840-00470-2-60\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSeries\u003c\/th\u003e\n      \u003ctd\u003eFR-F800 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProduct Type\u003c\/th\u003e\n      \u003ctd\u003eEnergy-Saving Inverter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eApplicable Motor Capacity (SLD)\u003c\/th\u003e\n      \u003ctd\u003e22 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInput Voltage \/ Phase\u003c\/th\u003e\n      \u003ctd\u003eThree-phase 380 to 500 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePermissible AC Voltage Fluctuation\u003c\/th\u003e\n      \u003ctd\u003e323 to 550 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInput Frequency\u003c\/th\u003e\n      \u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSLD Overload Current Rating\u003c\/th\u003e\n      \u003ctd\u003e110% for 60 seconds, 120% for 3 seconds (inverse-time characteristics) at surrounding air temperature 40 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eLD Overload Current Rating\u003c\/th\u003e\n      \u003ctd\u003e120% for 60 seconds, 150% for 3 seconds (inverse-time characteristics) at surrounding air temperature 50 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n      \u003ctd\u003e250 mm x 400 mm x 190 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eNet Weight\u003c\/th\u003e\n      \u003ctd\u003e15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eShipping Weight\u003c\/th\u003e\n      \u003ctd\u003e17 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the inverter vertically on a flat, non-flammable surface to facilitate optimal heat dissipation. Ensure a minimum clearance above, below, and to the sides of the chassis to allow unobstructed airflow from the internal cooling fans. All power wiring must use appropriately sized, shielded cables to suppress electromagnetic interference (EMI). Ground the unit via a low-impedance ground terminal directly to the main system backplane to ensure electrical safety and noise mitigation.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102132068715,"sku":"FR-F840-00470-2-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fr-f840-00470-2-60-gmodaqkgm2s.png?v=1776137513","url":"https:\/\/www.plcprotech.com\/tr\/products\/mitsubishi-electric-fr-f840-00470-2-60-fr-f800-energy-saving-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}