{"product_id":"mitsubishi-electric-fr-f840-03610-2-60-fr-f800-series-inverter","title":"Mitsubishi Electric FR-F840-03610-2-60 FR-F800 Series Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-capacity industrial pump, fan, and HVAC applications, the \u003cstrong\u003eFR-F840-03610-2-60\u003c\/strong\u003e is a high-efficiency \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e (VFD) from the Mitsubishi Electric FR-F800 series. This three-phase inverter optimizes energy consumption through advanced motor excitation algorithms and sophisticated PID control functions. Designed to drive induction and permanent magnet motors, it provides precise speed control and torque management under varied load profiles.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features integrated safety and network integration mechanisms, facilitating seamless deployment into decentralized DCS or PLC architectures. With its built-in EMC filter and robust electrical protections, it handles demanding heavy industrial environments while minimizing electromagnetic interference on adjacent control wiring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdvanced Optimum Excitation Control constantly adjusts excitation current to achieve maximum motor efficiency under changing load conditions.\u003c\/li\u003e\n  \u003cli\u003eDual rating specification (Super Light Duty and Light Duty) allows optimal sizing based on system application demands.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PID controller supports multi-pump control, sleep mode, and water hammer prevention functions.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Safety Torque Off (STO) function compliant with international safety standards for secure emergency stops.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in EMC filter limits electromagnetic noise emissions to maintain control signal integrity.\u003c\/li\u003e\n  \u003cli\u003eSupport for multiple industrial communication protocols via optional option cards, including CC-Link, Profibus-DP, and EtherCAT.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMunicipal water supply and wastewater treatment pumping stations.\u003c\/li\u003e\n  \u003cli\u003eLarge-scale industrial ventilation fans and air handling units (AHUs).\u003c\/li\u003e\n  \u003cli\u003eCooling towers and secondary cooling water circulation loops.\u003c\/li\u003e\n  \u003cli\u003eBoiler feed pumps and exhaust gas extraction systems.\u003c\/li\u003e\n  \u003cli\u003eChiller control and commercial building automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-F840-03610-2-60\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-F800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400V Class (Three-Phase 380 to 500 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 \/ 60 Hz (plus\/minus 5%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current (SLD - Super Light Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e361 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current (LD - Light Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e310 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Capacity (SLD)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e185 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Capacity (LD)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e160 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV\/F Control, Advanced Magnetic Flux Vector Control, Real Sensorless Vector Control, Optimum Excitation Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP00 (Open Type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eForced Air Cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-10 to 50 degC (non-freezing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Group\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eR\/L1, S\/L2, T\/L3\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase AC power input connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eU, V, W\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase AC output connections to motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eP\/+, N\/-\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDC bus link terminals for regenerative brake options or shared DC bus configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMulti-function digital inputs, analog current\/voltage inputs, open-collector and relay output terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEthernet\/PU Port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRJ-45 connector for parameter unit connection and Modbus RTU communication\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install the inverter vertically on a flat, non-combustible surface. Maintain minimum clearances above, below, and to the sides of the chassis to ensure unobstructed airflow from the cooling fans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e In enclosed control cabinets, ensure the heat dissipation capacity is sufficient to handle the thermal load of an 80 kg drive operating at full load. Use auxiliary extraction fans if cabinet ambient exceeds 40 degC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Always ground the inverter protective earth (PE) terminal. Use shielded motor cables with proper 360-degree EMC clamp connections to minimize high-frequency noise leakage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMain Circuit Wiring:\u003c\/strong\u003e Select wire gauges capable of carrying the full rated input\/output currents of 361A\/310A. Ensure high-torque termination on main power lugs to prevent hot spots.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102135411051,"sku":"FR-F840-03610-2-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fr-f840-03610-2-60-42rkp0hiimm.png?v=1776137523","url":"https:\/\/www.plcprotech.com\/tr\/products\/mitsubishi-electric-fr-f840-03610-2-60-fr-f800-series-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}