{"product_id":"mitsubishi-electric-q80bd-j71gp21s-sx-cc-link-ie-controller-network-interface-board","title":"Mitsubishi Electric Q80BD-J71GP21S-SX CC-Link IE Controller Network Interface Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating industrial PC-based systems into high-speed automation networks is streamlined using the \u003cstrong\u003eQ80BD-J71GP21S-SX\u003c\/strong\u003e interface board, which facilitates seamless connection to a \u003cstrong\u003eCC-Link IE Controller Network\u003c\/strong\u003e. This high-performance PCI\/PCI-X compatible board provides gigabit-rate optical loop communication, delivering large-capacity deterministic data exchange across industrial plant architectures. Designed for physical placement within industrial computer chassis, it features dual-loop redundancy to protect against network partition during cable breaks or individual station power-downs.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports gigabit transmission speeds of 1 Gbps via reliable optical fiber media.\u003c\/li\u003e\n  \u003cli\u003eDouble-loop transmission path configuration guarantees network loopback functionality in the event of cable failures.\u003c\/li\u003e\n  \u003cli\u003eDesigned for versatility with standard PCI or PCI-X half-size single-slot form factors.\u003c\/li\u003e\n  \u003cli\u003eLarge cyclic data capacity handling up to 128 K points (LW) per network and up to 32 K points per station under extended mode.\u003c\/li\u003e\n  \u003cli\u003eLaser Class 1 compliant design following international standards (JIS C 6802 and IEC 60825-1).\u003c\/li\u003e\n  \u003cli\u003eExternal power supply input keeps the optical bypass circuitry alive when the host computer is turned off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentralized supervisory control and data acquisition (SCADA) systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly line network synchronization.\u003c\/li\u003e\n  \u003cli\u003eLarge-scale material handling and distribution systems.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed industrial PC-to-PLC distributed communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQ80BD-J71GP21S-SX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCC-Link IE Controller Network Interface Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterface Slot Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePCI or PCI-X slot (half size, occupies 1 slot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Number of Installable Boards\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 4 boards per host system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 Gbps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Path Format\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDouble loop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eToken ring method\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Connection Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultimode optical fiber (GI) complying with 1000 BASE-SX standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDouble LC connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLaser Classification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass 1 laser product (JIS C 6802, IEC 60825-1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Connected Stations per Network\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 units (1 management station, 119 normal stations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Number of Networks\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e239\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Number of Groups\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Inter-Station Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e550 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Extension Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e66,000 m (when maximum of 120 units are connected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Link Points (Network)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLB: 32 K points (32768 points)\u003cbr\u003eLW: 128 K points (131072 points)\u003cbr\u003eLX: 8 K points (8192 points)\u003cbr\u003eLY: 8 K points (8192 points)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransient Transmission Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 1920 bytes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDC 20.4 V to 31.2 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.27 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAllowable Momentary Power Failure Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 ms (level PS 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Current Consumption (DC 5 V)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating \/ Storage Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMeets JIS B 3502, IEC 61131-2 standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eImpact Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMeets JIS B 3502, IEC 61131-2 standards (147 m\/s2, 3 times in X, Y, and Z directions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways shut down the host industrial computer and completely isolate all external power sources before installing the interface card into the PCI\/PCI-X slot.\u003c\/li\u003e\n  \u003cli\u003eEnsure strict static electricity protection measures are taken while handling the board to prevent ESD damage to delicate onboard micro-components.\u003c\/li\u003e\n  \u003cli\u003eAdhere to the minimum allowable bending radius specified for optical fiber cables to prevent signal attenuation or physical damage during connection.\u003c\/li\u003e\n  \u003cli\u003eConnect the auxiliary DC 24V external power supply directly to the card terminal block to ensure loopback routing functionality remains active when the PC is turned off.\u003c\/li\u003e\n  \u003cli\u003eEnsure the system is housed in an industrial control enclosure that meets Pollution Degree 2 or better guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102125842795,"sku":"Q80BD-J71GP21S-SX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Q80BD-J71GP21S-SX-wy4fsicc2wg.png?v=1776137974","url":"https:\/\/www.plcprotech.com\/tr\/products\/mitsubishi-electric-q80bd-j71gp21s-sx-cc-link-ie-controller-network-interface-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}