{"product_id":"mitsubishi-electric-qj71gf11-t2-cc-link-ie-field-master-module","title":"Mitsubishi Electric QJ71GF11-T2 CC-Link IE Field Master Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating seamlessly into high-speed industrial networks, the \u003cstrong\u003eQJ71GF11-T2\u003c\/strong\u003e serves as a high-performance communication interface within the MELSEC-Q automation platform. This module enables deterministic, high-capacity data exchange by functioning as either a master or local station on a CC-Link IE Field network. Operating at a transmission speed of 1 Gbps, it manages extensive digital and analog I\/O points across distributed automation architectures, ensuring synchronized control and rapid diagnostic capabilities.\u003c\/p\u003e\n\n\u003cp\u003eThe unit supports versatile physical layouts including line, star, and ring network topologies, which can be combined to suit complex factory floor environments. Its integration within the MELSEC-Q series allows for straightforward configuration via GX Works software, reducing engineering overhead and optimizing data throughput for heavy industrial processing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Communication:\u003c\/strong\u003e Operates at a physical layer speed of 1 Gbps for rapid data transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Topologies:\u003c\/strong\u003e Supports line, star, and ring network configurations, including hybrid line\/star systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Role Capability:\u003c\/strong\u003e Configurable as either a network Master Station or a Local Station.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eToken Passing Method:\u003c\/strong\u003e Implements a deterministic token-passing communication scheme to prevent network collisions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMassive Data Capacity:\u003c\/strong\u003e Handles up to 16,384 RX\/RY points and 8,192 RWr\/RWw words per network.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Distances:\u003c\/strong\u003e Supports up to 100 meters between stations and up to 12,100 meters total loop distance in ring configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly and robotic welding lines\u003c\/li\u003e\n  \u003cli\u003eHigh-speed packaging and sorting machinery\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment distribution systems\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and automated warehousing systems\u003c\/li\u003e\n  \u003cli\u003eDistributed PLC-to-PLC communication links in processing plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQJ71GF11-T2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCC-Link IE Field Network Master\/Local Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 Gbps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStation Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaster Station, Local Station\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eToken passing method\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum RX Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16,384 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum RY Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16,384 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum RWr Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8,192 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum RWw Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8,192 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCategory 5e or higher (Double-shielded, STP) straight cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Station-to-Station Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 m (Compliant with ANSI\/TIA\/EIA-568-B Category 5e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Total Distance (Line)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12,000 m (1 master and 120 slave stations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Total Distance (Ring)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12,100 m (1 master and 120 slave stations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOccupied I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Current Consumption (5 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.85 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.4 mm x 98 mm x 115 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.18 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePort Label\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunctional Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePORT1\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003ePrimary CC-Link IE Field connection port (1000BASE-T)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePORT2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eSecondary CC-Link IE Field connection port for ring, line, or star daisy-chaining\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Place the module into the standard slot of a MELSEC-Q series main or extension base unit. Secure the unit with the module fixing screw to prevent vibration-induced disconnections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling Requirements:\u003c\/strong\u003e Use only double-shielded, Category 5e or higher STP straight cables. Standard unshielded twisted pair (UTP) cables should not be used due to noise sensitivity at 1 Gbps speeds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Abatement:\u003c\/strong\u003e Route communication cables away from high-voltage cables and motor drive lines by a minimum of 100 mm to avoid electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the base unit's functional ground (FG) terminal is connected to a dedicated class D ground (grounding resistance of 100 ohms or less).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102135312747,"sku":"QJ71GF11-T2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/qj71gf11-t2-14maoa3452o.png?v=1776138006","url":"https:\/\/www.plcprotech.com\/tr\/products\/mitsubishi-electric-qj71gf11-t2-cc-link-ie-field-master-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}