{"product_id":"omron-c40p-cdr-a-sysmac-c-series-programmable-controller","title":"Omron C40P-CDR-A Sysmac C Series Programmable Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating as a standalone automation platform, the Omron C40P-CDR-A provides reliable control for legacy industrial processes. This block-style programmable logic controller integrates both discrete inputs and rugged relay outputs into a single, compact chassis. It is engineered with an internal universal AC power supply, making it highly adaptable for localized plant modifications, machinery retrofits, and reliable replacements in legacy control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntegrated layout containing 40 total discrete I\/O channels in a single physical block.\u003c\/li\u003e\n  \u003cli\u003eRobust electromechanical relay outputs capable of directly switching moderate inductive and resistive AC\/DC loads.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in wide-range AC power supply module that operates directly on standard plant control voltages.\u003c\/li\u003e\n  \u003cli\u003eDedicated programming port designed for interface with legacy handheld consoles and peripheral software tools.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty screw terminal strip allowing secure, direct physical wire connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eLegacy machinery retrofits and continuous manufacturing plant support operations.\u003c\/li\u003e\n  \u003cli\u003eSmall-scale material handling, packaging machinery, and dedicated conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eBasic municipal water treatment systems, pumping stations, and fan dampening controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eC40P-CDR-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eController Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSysmac C Series (C_P Class)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTotal I\/O Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e40 Points\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 DC Inputs (24 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOutput Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e16 Relay Outputs (Electromechanical Contacts)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDirect Panel Mounting\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBackup Memory Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRAM with Lithium Battery Backup \/ Optional ROM Option\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.6 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e300 mm x 150 mm x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eL1, L2\/N\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAC Input Power Terminals (100-240 VAC Line\/Neutral)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eLG \/ GR\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLine Ground and Frame Protective Earth Terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e00 to 11 (Ch 0)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDiscrete DC Inputs (Channels 0.00 to 0.11)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e00 to 11 (Ch 1)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDiscrete DC Inputs (Channels 1.00 to 1.11)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e00 to 07 (Ch 10)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDiscrete Relay Output Contacts (Channels 10.00 to 10.07)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e00 to 07 (Ch 11)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDiscrete Relay Output Contacts (Channels 11.00 to 11.07)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDirect code migration from this model to modern Sysmac CP1E or CP2E PLCs requires a complete ladder logic instruction translation. Key differences exist in the addressing mapping of data memory registers. Ensure that any replacement of legacy systems takes into physical consideration the differing footprint sizes and wiring layout orientations.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe electromechanical relay contacts inside this module will degrade prematurely if used to drive highly inductive AC solenoid valves or contactor coils without external suppressors. Always wire a surge suppressor (RC snubber) across AC inductive loads, or a fast freewheeling diode across DC inductive loads to prevent contact welding and operational locking.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain RAM program integrity during swap-outs, the internal backup lithium battery must only be replaced while the controller is powered ON. Alternatively, ensure the backup capacitor has been charged by keeping the power on for at least 15 minutes before executing a swift powered-down battery replacement within a 5-minute window.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all high-voltage AC input lines connected to L1 and L2\/N terminals are fully isolated and locked out prior to handling terminations or removing the terminal block covers. Failure to de-energize the main panel feed may result in severe shock hazard and permanent electrical damage to the logic circuitry.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the chassis onto a clean, flat metallic backplate inside an IP54-rated industrial control enclosure to preserve heat dissipation pathways.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 100-240 VAC supply power utilizing a minimum of 16 AWG insulated copper conductor to L1 and L2\/N terminals, ensuring correct torque is applied.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEstablish a low-impedance connection from the Line Ground terminal directly to the central chassis grounding busbar to mitigate external high-frequency electrical noise.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the total load draw of the combined outputs does not exceed the aggregate limit dictated by the internal terminal block common pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077926412651,"sku":"C40P-CDR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/C40P-CDR-A-bqbjww1bkqk.png?v=1775733466","url":"https:\/\/www.plcprotech.com\/tr\/products\/omron-c40p-cdr-a-sysmac-c-series-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}