{"product_id":"omron-cp1e-n40s1dt-d-cp1e-plc-programmable-controller","title":"Omron CP1E-N40S1DT-D CP1E PLC Programmable Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for compact machine control and distributed automation networks, the \u003cstrong\u003eOmron CP1E-N40S1DT-D\u003c\/strong\u003e functions as a versatile, cost-effective programmable logic controller (PLC) within the CP1E series. This application-class CPU unit integrates 40 onboard I\/O points, comprising 24 DC inputs and 16 sinking transistor outputs, making it highly suitable for high-speed switching and positioning applications. Featuring a built-in RS-485 serial port alongside a standard USB programming interface, this controller facilitates seamless integration with human-machine interfaces (HMIs), frequency inverters, and third-party Modbus RTU systems without requiring additional communication option boards.\u003c\/p\u003e\n\n\u003cp\u003eThe unit operates on a 24 VDC nominal power supply, rendering it compatible with standard industrial control panels. With its enhanced processing capabilities, the renewal \"S1\" design variant optimizes memory handling and communication diagnostics, making it an excellent replacement or new deployment module for manufacturing, packaging, and basic material handling control systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOnboard configuration of 40 discrete I\/O points (24 inputs, 16 outputs) for versatile signal processing.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in RS-485 communication port supporting Modbus-RTU Easy Master functionality.\u003c\/li\u003e\n  \u003cli\u003ePeripheral USB 2.0 port for direct programming, monitoring, and commissioning via CX-Programmer.\u003c\/li\u003e\n  \u003cli\u003eSinking transistor outputs designed for low-latency operations and driving solid-state relays or solenoids.\u003c\/li\u003e\n  \u003cli\u003eSupport for high-speed counters up to 100 kHz on standard input channels for rotary encoder feedback.\u003c\/li\u003e\n  \u003cli\u003eRobust DIN-rail mountable housing designed to withstand standard industrial operating environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and automated conveyor sorting systems.\u003c\/li\u003e\n  \u003cli\u003ePumping station control and localized wastewater management systems.\u003c\/li\u003e\n  \u003cli\u003eDedicated machine tools and component assembly equipment.\u003c\/li\u003e\n  \u003cli\u003eHVAC ventilation systems and localized environmental monitoring stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCP1E-N40S1DT-D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCP1E (Application Model, Renewal Variant S1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC (Operating range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 W maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Onboard I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 points, 24 VDC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 points, Transistor (Sinking)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBuilt-in Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x USB Port (Type B), 1x RS-485 Port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8K steps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8K words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHigh-Speed Counter Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 phases (2 axes at 100 kHz, 4 axes at 10 kHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePulse Output Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 axes (100 kHz maximum frequency)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 kg (including commercial packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal\/Interface Type\u003c\/th\u003e\n      \u003cth\u003eFunction and Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC positive (+) and negative (-) inputs with functional ground terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals (00 to 11)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC sourcing or sinking discrete inputs for sensors and switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals (00 to 07)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSinking transistor connections requiring external common negative reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRS-485 Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential communication lines (A-, B+) for network networking\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType-B connection point for diagnostic PC running CX-One\/CX-Programmer\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the PLC on a standard 35 mm DIN rail inside a protective, dust-free enclosure rated at IP54 or higher.\u003c\/li\u003e\n  \u003cli\u003eEnsure vertical clearance of at least 50 mm above and below the module to maintain natural air convection.\u003c\/li\u003e\n  \u003cli\u003eRoute low-voltage DC sensor lines and communication cables separate from high-voltage AC power wiring to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eEnsure the functional ground terminal is connected directly to a low-impedance earth ground point (under 100 Ohms).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliance (EMC Directive)\u003c\/li\u003e\n  \u003cli\u003eUL Listed (Class I, Division 2 Hazardous Locations)\u003c\/li\u003e\n  \u003cli\u003ecULus Certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077913731435,"sku":"CP1E-N40S1DT-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CP1E-N40S1DT-D-vlsfhmwn13f.png?v=1775733580","url":"https:\/\/www.plcprotech.com\/tr\/products\/omron-cp1e-n40s1dt-d-cp1e-plc-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}