{"product_id":"omron-nx102-9000-sysmac-nx1-modular-cpu","title":"Omron NX102-9000 Sysmac NX1 Modular CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegration of sequence, motion, and information processing within a single compact controller footprint characterizes the \u003cstrong\u003eOmron NX102-9000\u003c\/strong\u003e CPU unit. Engineered for the \u003cstrong\u003eSysmac NX1\u003c\/strong\u003e platform, this controller facilitates synchronized control of local I\/O and motion devices via EtherCAT, while simultaneously managing upstream IT enterprise communications. It provides direct connectivity to databases and secure machine-to-machine communications without requiring intermediate gateways, making it a pivotal component in modern industrial internet of things (IIoT) architectures.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eNX102-9000\u003c\/strong\u003e utilizes a unified backplane bus, allowing seamless connection of NX-series digital, analog, and specialty I\/O modules directly to the CPU. Its integrated memory structure and processing speed ensure reliable execution of complex sequence and position control routines in high-throughput automated systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt-in EtherCAT Master and dual-port EtherNet\/IP interfaces for high-speed deterministic networking.\u003c\/li\u003e\n  \u003cli\u003eIntegrated OPC UA server functionality for secure, standardized vertical integration to MES, SCADA, and cloud platforms.\u003c\/li\u003e\n  \u003cli\u003eDirect execution of sequence and position control programs within a single, unified runtime environment.\u003c\/li\u003e\n  \u003cli\u003eSupport for up to 32 local NX I\/O expansion units on a high-speed backplane.\u003c\/li\u003e\n  \u003cli\u003eRobust memory resources including 5 MB of program storage and 33.5 MB of variables memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-speed packaging, wrapping, and labeling machinery.\u003c\/li\u003e\n  \u003cli\u003eAutomated material handling, sorting, and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly line sub-stations requiring distributed EtherCAT control.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal treatment infrastructure requiring secure telemetry and remote connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX102-9000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSysmac NX1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController Functionality\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOPC-UA, Position control, Sequence control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVariables Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e33.5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBuilt-in Communication Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSerial RS-232C, Serial RS-422, Serial RS-485 (via option boards)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Remote I\/O Nodes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Expansion Units\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 cm x 6.6 cm x 10 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (Shipping weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Port\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eDeterministic machine control network connection (Master)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherNet\/IP Ports\u003c\/td\u003e\n      \u003ctd\u003eRJ45 (2 ports)\u003c\/td\u003e\n      \u003ctd\u003eFactory automation network, M2M, OPC UA, and host communication\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Port\u003c\/td\u003e\n      \u003ctd\u003eUSB Type-B\u003c\/td\u003e\n      \u003ctd\u003eDirect connection to Sysmac Studio programming software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption Board Slots\u003c\/td\u003e\n      \u003ctd\u003eProprietary expansion slot\u003c\/td\u003e\n      \u003ctd\u003eAccepts serial option boards (RS-232C, RS-422, RS-485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount horizontally on a standard 35 mm DIN rail. Ensure the lock levers are fully engaged to prevent sliding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain a minimum clearance of 30 mm above and below the CPU module to facilitate natural convection cooling. Do not block the integrated vents.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground (FG) terminal directly to a dedicated ground electrode of 100 ohms or less using minimum 2 mm square wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use double-shielded twisted-pair cables (Category 5e or higher) for EtherCAT and EtherNet\/IP connections to prevent electromagnetic noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark\u003c\/li\u003e\n  \u003cli\u003ecULus Listed\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Communications Commission)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077906588011,"sku":"NX102-9000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx102-9000-abfj1qvthvh.png?v=1775734039","url":"https:\/\/www.plcprotech.com\/tr\/products\/omron-nx102-9000-sysmac-nx1-modular-cpu","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}