{"product_id":"schneider-modicon-momentum-170fnt11000-fipio-adapter","title":"Schneider Modicon Momentum 170FNT11000 FIPIO Adaptörü","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e170FNT11000\u003c\/strong\u003e is a specialized \u003cstrong\u003eFIPIO Adapter\u003c\/strong\u003e designed for the \u003cstrong\u003eModicon Momentum\u003c\/strong\u003e automation platform. This module serves as the communication interface that allows Momentum I\/O bases to be integrated into a \u003cstrong\u003eFIPIO (Fieldbus Interface Processor Input\/Output)\u003c\/strong\u003e fieldbus network. By acting as the network node, the adapter enables the PLC controller to exchange process data with distributed Momentum I\/O stations over the FIPIO fieldbus. This facilitates flexible, decentralized automation architectures, allowing for the reliable distribution of control signals across larger plant floors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIPIO Network Integration\u003c\/strong\u003e: Enables Momentum I\/O platforms to communicate via the standard FIPIO fieldbus protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Compatibility\u003c\/strong\u003e: Specifically engineered for the Modicon Momentum range, ensuring easy \"snap-on\" assembly with I\/O bases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Automation\u003c\/strong\u003e: Supports decentralized system architectures, reducing cabling requirements and improving system scalability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Connectivity\u003c\/strong\u003e: Provides a dedicated node for reliable, real-time deterministic communication in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed control architectures in manufacturing and process automation.\u003c\/li\u003e\n\u003cli\u003eRemote I\/O connectivity for PLC systems operating on FIPIO networks.\u003c\/li\u003e\n\u003cli\u003eIndustrial facility automation requiring decentralized signal collection.\u003c\/li\u003e\n\u003cli\u003eSystem maintenance and expansion of legacy Modicon Momentum installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Momentum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFIPIO Adapter (Digital modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n\u003ctd\u003eFIPIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Assembly\u003c\/strong\u003e: The adapter is designed to snap onto a Momentum I\/O base. Ensure the connector pins on the base are clean and undamaged before sliding the adapter into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Wiring\u003c\/strong\u003e: Use the appropriate FIPIO-certified cables and connectors. Ensure that the bus line is properly terminated at both ends of the network segment to prevent signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing\u003c\/strong\u003e: Configure the node address (if applicable) using the designated switches or software configuration tools to ensure correct identification on the FIPIO bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the shield of the FIPIO cable to the appropriate terminal on the adapter to maintain electromagnetic immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Check\u003c\/strong\u003e: Post-installation, verify the communication status LEDs on the adapter. A steady status light typically indicates successful network communication and proper node synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104562700651,"sku":"170FNT11000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170fnt11000-3tpw0zsv2yh.png?v=1776159724","url":"https:\/\/www.plcprotech.com\/tr\/products\/schneider-modicon-momentum-170fnt11000-fipio-adapter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}