{"product_id":"schneider-modicon-premium-tsxaey810c-analog-input-module","title":"Schneider Modicon Premium TSXAEY810C Analog Giriş Modülü","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXAEY810C\u003c\/strong\u003e is a high-precision \u003cstrong\u003eanalog input module\u003c\/strong\u003e developed for the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e automation platform. This module features \u003cstrong\u003e8 low-level input channels\u003c\/strong\u003e capable of handling both current and voltage signals. With an integrated \u003cstrong\u003e16-bit resolution\u003c\/strong\u003e, it provides the high-fidelity signal conversion necessary for complex process monitoring and control tasks. Designed to act as a reliable interface between sensitive field instrumentation and the PLC CPU, the TSXAEY810C is a standard choice for industrial applications requiring accurate measurement and rapid data acquisition.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Support\u003c\/strong\u003e: Configurable for either current or voltage input signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution\u003c\/strong\u003e: 16-bit A\/D conversion for superior measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Density\u003c\/strong\u003e: 8 isolated channels for simultaneous process monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModicon Premium Compatibility\u003c\/strong\u003e: Native design for seamless integration with Premium PLC backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: Engineered to perform consistently in demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision process control (e.g., pressure, flow, and temperature monitoring).\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy data acquisition systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial laboratory or test stand automation.\u003c\/li\u003e\n\u003cli\u003eFeedback loop management in complex manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eCurrent, Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 x 26.00 x 5.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Ensure the module is properly aligned with the rack guide rails and fully seated to guarantee a stable electrical connection to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Shielding\u003c\/strong\u003e: Always use shielded, twisted-pair cabling for analog signals to minimize the impact of electromagnetic interference (EMI). Ground the shields at the PLC cabinet side only, unless otherwise specified by the system design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Use the PLC programming software to configure the specific input range (current or voltage) for each channel to avoid signal mismatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e: Periodically verify the analog measurement accuracy against a known reference source to maintain process precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Ensure the control cabinet provides adequate ambient cooling, as high temperatures can influence the accuracy of high-resolution analog measurements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104563126635,"sku":"TSXAEY810C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxaey810c-sctsmilij5l.png?v=1776163725","url":"https:\/\/www.plcprotech.com\/tr\/products\/schneider-modicon-premium-tsxaey810c-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}