{"product_id":"schneider-rm4lg01f-liquid-level-control-relay","title":"Schneider RM4LG01F Sıvı Seviyesi Kontrol Rölesi","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRM4LG01F\u003c\/strong\u003e is a \u003cstrong\u003eLiquid Level Control Relay\u003c\/strong\u003e from the \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e control gear portfolio, specifically engineered for the management and monitoring of conductive liquid levels. This relay is designed to ensure reliable automatic filling or emptying operations in industrial tanks and reservoirs, providing precise control for pumps and solenoid valves based on probe detection.\u003c\/p\u003e\n\u003cp\u003eAs a member of the \u003cstrong\u003eRM4\u003c\/strong\u003e control relay series, the \u003cstrong\u003eRM4LG01F\u003c\/strong\u003e is recognized for its durability in demanding electrical automation environments. Although this model has reached the phase-out stage of its product lifecycle, it remains a critical spare part for maintaining legacy control systems where precise level regulation is required for operational safety and efficiency.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized liquid level control for conductive fluids\u003c\/li\u003e\n\u003cli\u003eDesigned for automatic filling or emptying management\u003c\/li\u003e\n\u003cli\u003eRobust relay output for direct or indirect pump control\u003c\/li\u003e\n\u003cli\u003eCompact housing for efficient installation in control cabinets\u003c\/li\u003e\n\u003cli\u003eEngineered for high reliability in industrial automation tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial tank filling and emptying systems\u003c\/li\u003e\n\u003cli\u003eMonitoring of conductive liquid levels in process vessels\u003c\/li\u003e\n\u003cli\u003eProtection against dry-running of pumps\u003c\/li\u003e\n\u003cli\u003eAutomated reservoir management\u003c\/li\u003e\n\u003cli\u003eWater treatment and processing infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eRM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLiquid Level Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.00 x 12.00 x 10.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the relay on a standard DIN rail within a protected electrical enclosure to prevent exposure to environmental contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbes:\u003c\/strong\u003e Ensure the liquid level probes are installed at the required sensing levels and are cleaned periodically to prevent mineral buildup, which can cause false readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the probes and load contacts according to the specific wiring diagram found on the device housing or the original manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain a consistent reference ground for the conductive liquid to ensure accurate probe detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always verify that the control circuit voltage matches the relay specifications before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104561586539,"sku":"RM4LG01F","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/rm4lg01f-3vim24y2hj1.png?v=1776163457","url":"https:\/\/www.plcprotech.com\/tr\/products\/schneider-rm4lg01f-liquid-level-control-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}