{"product_id":"siemens-6av7875-0bd30-1ac0-simatic-panel-pc-677b","title":"Siemens 6AV7875-0BD30-1AC0 SIMATIC Panel PC 677B","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7875-0BD30-1AC0 is a SIMATIC Panel PC 677B designed for industrial human-machine interface (HMI) and control applications. This unit integrates a \u003cstrong\u003e19-inch touch display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e1280 x 1024 pixels\u003c\/strong\u003e into a robust panel-mount chassis. It is powered by an Intel \u003cstrong\u003eCore 2 Duo T5500 processor\u003c\/strong\u003e and is equipped with \u003cstrong\u003e2 GB of DDR2 RAM\u003c\/strong\u003e and a \u003cstrong\u003e160 GB SATA hard disk drive\u003c\/strong\u003e. Connectivity options are extensive, featuring dual Gigabit Ethernet ports, USB 2.0, a serial port, and an integrated \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. The system is pre-installed with Windows XP Professional and includes an internal AC power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e19-inch touch-sensitive color display\u003c\/li\u003e\n  \u003cli\u003eIntel Core 2 Duo T5500 processor at 1.66 GHz\u003c\/li\u003e\n  \u003cli\u003e2 GB DDR2 system memory\u003c\/li\u003e\n  \u003cli\u003e160 GB 3.5-inch SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n  \u003cli\u003eIntegrated DVD+\/-R+\/-RW optical drive\u003c\/li\u003e\n  \u003cli\u003eOnboard PROFIBUS\/MPI communication interface with 2 MB buffered SRAM\u003c\/li\u003e\n  \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network connectivity\u003c\/li\u003e\n  \u003cli\u003eConvenient front-side USB interface\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows XP Professional Multi-Language User Interface (MUI)\u003c\/li\u003e\n  \u003cli\u003eInternal 110\/230 V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eProcess visualization and SCADA systems\u003c\/li\u003e\n  \u003cli\u003eMachine control and data acquisition\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES)\u003c\/li\u003e\n  \u003cli\u003eFactory floor operator stations\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSIMATIC Panel PC 677B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e19-inch Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1280 x 1024 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIntel Core 2 Duo T5500, 1.66 GHz, 2 MB SLC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMemory\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e2 GB DDR2 RAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e160 GB SATA HDD, 3.5-inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDVD+\/-R+\/-RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1x PCIe x4, 1x PCI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eUSB Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e4x USB 2.0 (rear), 1x USB (front)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSerial Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1x COM1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePROFIBUS\/MPI, 2 MB Buffered SRAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e110\/230 V AC with NAMUR (Europe power cable included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eWindows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e17.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e67.0 x 83.0 x 11.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eUnknown\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Disconnect and lock out all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e1\u003c\/span\u003e\n    Verify the panel cutout dimensions match the PC 677B chassis specifications before mounting.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e2\u003c\/span\u003e\n    Ensure adequate ventilation clearance around the rear of the unit for heat dissipation. Do not block vents.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e3\u003c\/span\u003e\n    Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to ensure a proper seal.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e4\u003c\/span\u003e\n    Connect the main protective earth (PE) terminal to the cabinet's ground bus using a low-impedance conductor.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e5\u003c\/span\u003e\n    Connect the AC power supply cord to a properly rated and protected power source.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px;\"\u003e6\u003c\/span\u003e\n    Connect all required network, fieldbus, and peripheral cables, ensuring proper strain relief.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715846205803,"sku":"6AV7875-0BD30-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7875-0bd30-1ac0-kjy5acnoohc_51e4b128-fecc-43ce-b5da-070bc4457de3.jpg?v=1767072477","url":"https:\/\/www.plcprotech.com\/tr\/products\/siemens-6av7875-0bd30-1ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}