{"product_id":"siemens-6es7718-1cc05-0ac0-simatic-field-pg-m6-advanced","title":"Siemens 6ES7718-1CC05-0AC0 SIMATIC Field PG M6 Advanced","description":"\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7718-1CC05-0AC0\u003c\/strong\u003e SIMATIC Field PG M6 Advanced is a robust, portable programming device engineered for demanding industrial automation tasks. This professional mobile workstation features a powerful Intel Core \u003cstrong\u003ei7-8850H\u003c\/strong\u003e processor operating from 2.6 to 4.3 GHz, complete with 6 kernels, hyper-threading, and a 9 MB Smart Cache. Visuals are delivered via a sharp 15.6-inch Full HD (1920x1080) display backed by integrated UHD Graphics 630. For seamless multitasking and extensive project data storage, it comes equipped with \u003cstrong\u003e32 GB DDR4 SD-RAM\u003c\/strong\u003e (1x SO-DIMM) and a high-capacity \u003cstrong\u003e2 TB SSD SATA\u003c\/strong\u003e (2.5\") drive.\u003c\/p\u003e\n\n\u003cp\u003eHigh-speed wireless deployment is fully supported through integrated \u003cstrong\u003eWLAN 802.11ac\u003c\/strong\u003e and \u003cstrong\u003eBluetooth V5.0\u003c\/strong\u003e hardware, alongside an integrated DVD +\/-RW optical drive. Operating on an embedded \u003cstrong\u003eWindows 10 Pro or Windows 11 Pro\u003c\/strong\u003e system architecture, this configuration is pre-loaded with engineering licenses for \u003cstrong\u003eSTEP 7 Professional Combo\u003c\/strong\u003e, \u003cstrong\u003eWinCC Advanced Combo\u003c\/strong\u003e, and \u003cstrong\u003eSafety Advanced Combo\u003c\/strong\u003e (all version V15.1), establishing a turnkey environment for TIA Portal applications. Please note this hardware revision does not feature an S5 interface or an S5-EPROMMER hardware link, and it ships configured with a UK power plug standard and a standard QWERTZ\/QWERTY layout keyboard panel.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Processing Power:\u003c\/strong\u003e Intel Core i7-8850H Processor running from 2.6 to 4.3 GHz with 6 hardware cores and 9 MB Smart Cache.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCrisp Display Surface:\u003c\/strong\u003e 15.6\" Full HD anti-glare display panel providing a clear 1920x1080 resolution for long engineering sessions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Volatile Memory:\u003c\/strong\u003e 1x 32 GB DDR4 SD-RAM SO-DIMM module for handling complex industrial simulation nodes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMassive Solid-State Storage:\u003c\/strong\u003e 2 TB SSD SATA 2.5-inch internal solid-state drive ensuring quick operating software boots and project load times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless Infrastructure:\u003c\/strong\u003e Integrated high-speed WLAN 802.11ac and stable Bluetooth V5.0 wireless peripheral communication links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Optical Drive:\u003c\/strong\u003e Built-in DVD +\/-RW drive for easy legacy software media loading and hardware image backups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTurnkey TIA Portal Software Suite:\u003c\/strong\u003e Includes factory software licenses for STEP 7 Professional Combo, WinCC Advanced Combo, and Safety Advanced Combo (V15.1).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLegacy Interface Exclusion:\u003c\/strong\u003e Modern hardware layout built without the legacy S5 system interface module or S5-EPROMMER.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegional Keyboard Panel:\u003c\/strong\u003e Built-in keyboard featuring a standard QWERTZ\/QWERTY dual-notation hardware layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOn-site programmable logic controller (PLC) engineering, field flashing, and precise diagnostics for SIMATIC automation hardware.\u003c\/li\u003e\n  \u003cli\u003eHuman Machine Interface (HMI) screen configuration, SCADA synchronization, and system visualization tasks inside control rooms.\u003c\/li\u003e\n  \u003cli\u003eComprehensive commissioning, field optimization, and regular maintenance routines for corporate SIMATIC automation frameworks.\u003c\/li\u003e\n  \u003cli\u003eReal-time troubleshooting, system monitoring, and deep bus-protocol analysis of distributed industrial control networks.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty mobile engineering workstation optimized for complex multi-user TIA Portal development and multi-version project deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"10\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\" bgcolor=\"#f7fafc\"\u003e\u003cstrong\u003eProduct Component\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth align=\"left\" bgcolor=\"#f7fafc\"\u003e\u003cstrong\u003eTechnical Specification Details\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eGeneral Framework\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n        \u003cstrong\u003eProduct Range:\u003c\/strong\u003e SIMATIC Field PG\u003cbr\u003e\n        \u003cstrong\u003eSubrange Variant:\u003c\/strong\u003e Field PG M6 Advanced\u003cbr\u003e\n        \u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e Phase-Out\u003cbr\u003e\n        \u003cstrong\u003eProduct Type:\u003c\/strong\u003e Industrial Programming Device\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eProcessing Architecture\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eCPU model:\u003c\/strong\u003e Intel Core i7-8850H (2.6 GHz base, up to 4.3 GHz turbo boost)\u003cbr\u003e\n        \u003cstrong\u003eCore Configuration:\u003c\/strong\u003e 6 Cores with hyper-threading processing technology\u003cbr\u003e\n        \u003cstrong\u003eProcessor Cache:\u003c\/strong\u003e 9 MB Smart Cache\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eDisplay \u0026amp; Graphics\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eScreen Dimension:\u003c\/strong\u003e 15.6 inch diagonal\u003cbr\u003e\n        \u003cstrong\u003eNative Resolution:\u003c\/strong\u003e Full HD (1920x1080 pixels)\u003cbr\u003e\n        \u003cstrong\u003eGraphics Processor:\u003c\/strong\u003e Integrated Intel UHD Graphics 630\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eMemory \u0026amp; Solid Storage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eRAM Capacity:\u003c\/strong\u003e 32 GB DDR4 SD-RAM (1x SO-DIMM form factor)\u003cbr\u003e\n        \u003cstrong\u003eInternal Storage:\u003c\/strong\u003e 2 TB SSD SATA (2.5\" form factor drive)\u003cbr\u003e\n        \u003cstrong\u003eM.2 NVMe Slot:\u003c\/strong\u003e Without internal M.2 NVMe card module\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eInterfaces \u0026amp; Peripherals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eWireless Networking:\u003c\/strong\u003e WLAN 802.11ac protocol support\u003cbr\u003e\n        \u003cstrong\u003eLocal Connectivity:\u003c\/strong\u003e Integrated Bluetooth V5.0 controller\u003cbr\u003e\n        \u003cstrong\u003eOptical Read\/Write:\u003c\/strong\u003e DVD +\/-RW media drive\u003cbr\u003e\n        \u003cstrong\u003eS5 Interface Link:\u003c\/strong\u003e Without legacy S5 connector interface\u003cbr\u003e\n        \u003cstrong\u003eS5-EPROMMER:\u003c\/strong\u003e Without legacy hardware programming interface\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eSoftware Environment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eOperating System:\u003c\/strong\u003e Embedded Windows 10 Pro or Windows 11 Pro\u003cbr\u003e\n        \u003cstrong\u003ePre-installed Licenses:\u003c\/strong\u003e STEP 7 Professional Combo, WinCC Advanced Combo, Safety Advanced Combo\u003cbr\u003e\n        \u003cstrong\u003eEngineering Version:\u003c\/strong\u003e V15.1 Software Framework Compatibility\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eHardware Form \u0026amp; Plug\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eMains Cord Type:\u003c\/strong\u003e UK Power Plug standard\u003cbr\u003e\n        \u003cstrong\u003eKeyboard Profile:\u003c\/strong\u003e QWERTZ\/QWERTY dual notation layout\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eLogistics Parameters\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\n        \u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3.20 kg\u003cbr\u003e\n        \u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 84713000\u003cbr\u003e\n        \u003cstrong\u003eExport Regulations (ECCN):\u003c\/strong\u003e 5A992\u003cbr\u003e\n        \u003cstrong\u003eCalculated Packaging Envelop:\u003c\/strong\u003e 39.50 x 30.00 x 17.00 cm\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"10\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\" bgcolor=\"#f7fafc\"\u003e\u003cstrong\u003eDeployment Phase\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth align=\"left\" bgcolor=\"#f7fafc\"\u003e\u003cstrong\u003eRequired Technical Step \u0026amp; Engineering Action\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 1: Unpacking \u0026amp; Inspection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eCarefully open the protective transport carton, extract the Field PG M6 device, and perform a complete visual assessment to check for signs of physical shipping distortion. Retain the specialized original packaging inserts to ensure secure transit during future field relocations.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 2: Power Grid Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003ePlug the supplied factory UK AC power cord connection firmly into the device's main power supply adapter block, then connect the standard plug to a stable grounding mains outlet source that complies with the exact electrical parameters of the system hardware.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 3: First Boot Setup\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eDepress the power terminal switch to activate the programming unit. Follow the sequential on-screen installer prompts to complete the primary operating system parameters, including default localization language settings, keyboard inputs, regional clocks, and secure supervisor administrative accounts.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 4: Automation License Activation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eInitialize the pre-loaded automation workspace software. Access the integrated licensing framework utilities to activate and allocate the STEP 7 Professional Combo, WinCC Advanced Combo, and Safety Advanced Combo (V15.1) product authorization strings exactly as specified by factory instructions.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 5: Peripheral Interface Linkage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eTerminate all necessary communication media, external engineering display monitors, industrial USB hardware dongles, or direct industrial Ethernet network cables to the matching physical interface ports to run targeted distributed network tests.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 6: Environmental Management\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eOperate this advanced programming device strictly inside the engineering parameters defined for ambient room temperature and relative atmospheric humidity levels. Maintain clean airspace around the device ventilation intakes to protect internal boards from dense dust tracking, moisture buildup, or direct exposure to high solar radiation.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003e\u003cstrong\u003eStep 7: Cybersecurity Practices\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd align=\"left\" valign=\"top\"\u003eEnforce robust local access control configurations across the operational framework. Set up highly complex administrative passwords, activate network firewall filters, and establish structured security patches to defend your connected plant automation platforms from cyber risks.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715770315115,"sku":"6ES7718-1CC05-0AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7718-1cc05-0ac0-n1qtfcnperj_3033385d-17a0-481d-931d-b13d80f233df.jpg?v=1767070762","url":"https:\/\/www.plcprotech.com\/tr\/products\/siemens-6es7718-1cc05-0ac0-simatic-field-pg-m6-advanced","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}