{"product_id":"weidmuller-1504230000-ie-sw-bl06-4poe-2st-basic-line-unmanaged-poe-switch","title":"Weidmuller 1504230000 IE-SW-BL06-4POE-2ST Basic Line Unmanaged PoE Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for demanding industrial Ethernet networks, the Weidmuller IE-SW-BL06-4POE-2ST (part number 1504230000) provides reliable Power over Ethernet (PoE+) distribution and fiber-optic connectivity in a compact, unmanaged form factor. This switch integrates \u003cstrong\u003efour 10\/100BaseT(X) PoE+ ports\u003c\/strong\u003e and \u003cstrong\u003etwo 100BaseFX multimode fiber ports\u003c\/strong\u003e with ST-Duplex connectors, making it an ideal choice for extending network segments up to 5 km while delivering power to field devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSupports IEEE 802.3at\/af standards, delivering up to 30 watts per PoE port.\u003c\/li\u003e\n  \u003cli\u003eDual redundant 24\/48 V DC power inputs to maximize network uptime.\u003c\/li\u003e\n  \u003cli\u003eRugged IP30-rated aluminum housing designed for space-constrained control cabinets.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with a 1 K MAC address table.\u003c\/li\u003e\n  \u003cli\u003eIntegrated broadcast storm protection to maintain network stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial automation and control system networks.\u003c\/li\u003e\n  \u003cli\u003eIP surveillance and security systems in harsh outdoor environments.\u003c\/li\u003e\n  \u003cli\u003ePower utility and substation monitoring requiring optical isolation.\u003c\/li\u003e\n  \u003cli\u003eWater\/wastewater treatment facilities and manufacturing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06-4POE-2ST\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504230000\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6-port unmanaged PoE switch, 4x PoE+ RJ45, 2x ST Multimode Fiber\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-BL06-4POE-2ST \/ 1504230000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged PoE+\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransceiver Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMultimode\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eST-Duplex\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVoltage Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24\/48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5.5 A at 24 V DC, 2.6 A at 48 V DC (at full PoE+ load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e512 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAluminium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary Power Input (+24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary Power Input Ground (GND)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRedundant Power Input (+24 \/ +48 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRedundant Power Input Ground (GND)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-BL06-4POE-2ST is part of Weidmuller's Basic Line industrial switch series. If single-mode fiber infrastructure is deployed on-site, the SC-connector or single-mode variants of this series should be utilized to match the optical budget and cable characteristics. It is fully backward compatible with standard IEEE 802.3af (15.4W) devices, automatically scaling power delivery based on connected PD (Powered Device) negotiation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen operating at the maximum ambient temperature limit of 60 degC with all four PoE+ ports delivering full 30W loads, ensure a minimum of 20mm lateral clearance from adjacent heat-generating DIN-rail devices. Enclosed control cabinets must have active ventilation to prevent localized thermal buildup. Note that current draw increases significantly at 24 V DC (up to 5.5 A) compared to 48 V DC (2.6 A); size your power supply and wiring gauges accordingly to prevent voltage drops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways clean the ST-Duplex fiber connectors with an approved optical cleaning tool before insertion. Even minor dust contamination can cause severe signal attenuation over the 5 km optical path. Ensure the IP30 aluminum housing is grounded using the integrated grounding screw to a low-impedance earth ground to protect internal circuitry from electrostatic discharge (ESD) and electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e \u003cspan style=\"color: #9b2c2c;\"\u003eDe-energize all power sources before connecting or disconnecting the 4-pin terminal block. Do not hot-plug the power connector under load. Verify that the supply voltage matches the specified 24\/48 V DC limits to avoid catastrophic damage to the switch.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch securely onto the TS35 DIN rail, ensuring the top hook engages first before pressing the bottom latch into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect a dedicated grounding wire from the ground screw on the switch chassis to the local protective earth ground point.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the 4-pin removable terminal block with your primary (V1) and optional redundant (V2) power lines, then secure the terminal screws.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 Ethernet cables into ports 1 through 4 and connect the ST-Duplex fiber cables to the optical ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102124040555,"sku":"IE-SW-BL06-4POE-2ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-4poe-2st-lldaxz03rsf.png?v=1776137755","url":"https:\/\/www.plcprotech.com\/tr\/products\/weidmuller-1504230000-ie-sw-bl06-4poe-2st-basic-line-unmanaged-poe-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}