{"title":"Allen-Bradley Point I\/O 1734","description":"\u003cp\u003eAllen-Bradley Point I\/O (1734-) yuqori zichlikdagi, joyni tejovchi taqsimlangan I\/O yechimi bo‘lib, mahalliy boshqaruv va yig‘ish ilovalari uchun optimallashtirilgan. Uning arxitekturasi tor, mayda modullardan iborat bo‘lib, ular DIN relsiga biriktiriladi va shkafdagi joy talabini minimallashtiradi. Texnik xususiyatlarga oson maydon simlash, olinadigan terminal bloklari va EtherNet\/IP hamda DeviceNet aloqa adapterlarini qo‘llab-quvvatlash kiradi. Funksional jihatdan, Point I\/O \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-compactlogix\"\u003eCompactLogix\u003c\/a\u003e yoki \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-micro800\"\u003eMicro800\u003c\/a\u003e tizimlari uchun moslashuvchan interfeys taqdim etadi, bu esa mashina yaqinida aniq I\/O kengaytmasini amalga oshirish imkonini beradi. Ushbu modul tuzilma yuqori tezlikdagi materiallarni boshqarish, robototexnika va pick-and-place uskunalari uchun juda mos bo‘lib, ixcham va ishonchli ulanishni ta’minlaydi.\u003c\/p\u003e","products":[{"product_id":"1734-ie4c-allen-bradley-point-i-o-4-channel-analog-current-input-module","title":"1734-IE4C Allen-Bradley POINT I\/O 4-Channel Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE4C (1734IE4C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. Designed for space-constrained applications, this module provides four independent channels for measuring industrial current signals, typically in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erange. As part of the modular POINT I\/O system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE4C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a compact footprint (12.7 mm width) without compromising on performance, featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-precision data acquisition. It is an ideal solution for monitoring process sensors such as flow meters, pressure transmitters, and temperature transducers in Distributed I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Logic \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE4C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a Sigma-Delta conversion technique to deliver high-accuracy digitized values to the controller via the POINT I\/O backplane (PointBus). Each channel is individually configurable, allowing for tailored filter frequencies and scaling. A key engineering advantage of the module is its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eon-board diagnostics\u003c\/strong\u003e, which can detect open-circuit (wire break) conditions in 4–20 mA mode and signal range over\/under-flow errors. The module is \"hot-swappable,\" allowing for Replacement Under Power (RIUP) when used with the appropriate terminal base, significantly reducing downtime during maintenance cycles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1734-IE4C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Single-Ended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit (0.305 µA\/cnt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigma-Delta\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 ms to 430 ms (depending on filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 V (continuous), Basic Insulation Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Base Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-TB or 1734-TBS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 16-bit resolution affect measurement precision?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit resolution\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE4C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan divide the 0–20 mA range into 65,536 discrete steps. This results in a precision of approximately\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.305 µA per count\u003c\/strong\u003e, allowing the control system to detect minute changes in sensor feedback, which is critical for high-accuracy chemical dosing or precision pressure control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1734-IE4C compatible with all POINT I\/O adapters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is designed for universal compatibility with 1734-series communication adapters, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENT (EtherNet\/IP)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-ADN (DeviceNet)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-APB (PROFIBUS)\u003c\/strong\u003e. Ensure your controller's EDS (Electronic Data Sheet) files are updated to the latest version for seamless integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide power to the sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE4C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereceives its power from the POINT I\/O backplane and the field power bus. While it can measure current from loop-powered sensors, the 24 VDC excitation power for the sensors is typically distributed through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-FPD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Field Power Distributor) or the common power terminals on the 1734-TB base.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183130987,"sku":"1734-IE4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1734-ie4c-point-i-o-4-point-analog-input-module-qgo1bqqjgpl_146cae2a-c6dd-4e11-8d3f-5bed88a52248.jpg?v=1766114366"},{"product_id":"allen-bradley-1734-ib4-point-i-o-4-point-digital-input-module","title":"Allen Bradley 1734-IB4 Point I\/O 4 Point Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-IB4\u003c\/strong\u003e is a 4-point sinking digital input module designed for the POINT I\/O system. The \u003cstrong\u003e1734-IB4\u003c\/strong\u003e interfaces field-side sensor devices—such as 2-wire or 3-wire proximity switches—with a central controller over I\/O networks like DeviceNet, PROFIBUS, ControlNet, or EtherNet\/IP via compatible adapters. Receiving 24V DC discrete signals, it produces 1 byte of input data for processor memory mapping.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 sinking DC input channels arranged in 1 group of 4\u003c\/li\u003e\n\u003cli\u003eDirect installation on DIN rail using compatible 1734 series terminal base assemblies\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for network status, module status, and individual channel input status\u003c\/li\u003e\n\u003cli\u003eKeyed insertion system to prevent improper module placement\u003c\/li\u003e\n\u003cli\u003eSupport for Removable Terminal Blocks (RTB) to allow module replacement without disturbing field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory automation and process control signal acquisition\u003c\/li\u003e\n\u003cli\u003eInterface for 2-wire and 3-wire DC proximity switches\u003c\/li\u003e\n\u003cli\u003eDiscrete limit switch and push-button input processing\u003c\/li\u003e\n\u003cli\u003eDistributed control systems utilizing POINT I\/O architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per Module\u003c\/td\u003e\n\u003ctd\u003e4 (1 group of 4), sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage, Nom\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10...28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current, Nom\u003c\/td\u003e\n\u003ctd\u003e4 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current, Max\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage, Max\u003c\/td\u003e\n\u003ctd\u003e5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current, Min\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance, Nom\u003c\/td\u003e\n\u003ctd\u003e3.6 kOHM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance, Max\u003c\/td\u003e\n\u003ctd\u003e4.7 kOHM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Time (Off-to-On)\u003c\/td\u003e\n\u003ctd\u003e0.5 ms hardware plus 0...63 ms (user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Time (On-to-Off)\u003c\/td\u003e\n\u003ctd\u003e0.5 ms hardware plus 0...63 ms (user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply Voltage, Nom\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10...28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current, Max\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation @ 28.8V DC, Max\u003c\/td\u003e\n\u003ctd\u003e1.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation @ 28.8V DC, Max\u003c\/td\u003e\n\u003ctd\u003e3.4 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V (continuous), Reinforced Insulation Type (Tested @ 2500V DC for 60 s, field-side to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyswitch Position\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.8 N-m (7 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D), Approx.\u003c\/td\u003e\n\u003ctd\u003e56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Approx.\u003c\/td\u003e\n\u003ctd\u003e31.8 g (1.12 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +55 degC (-4 degF to +131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eInput 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eInput 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eInput 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eInput 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eUser Supply (12\/24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eUser Supply (12\/24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Mount the module onto a zinc-plated chromate-passivated steel DIN rail (part number 199-DR1; 46277-3; EN50022) to establish proper chassis grounding. Secure the DIN rail every 200 mm (7.8 in.) and use end-anchors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Install inside an enclosure suitable for Pollution Degree 2 industrial environments, providing an ingress protection rating of at least IP54 for hazardous location applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keying:\u003c\/strong\u003e Rotate the keyswitch on the mounting base to position 1 before inserting the module. Ensure the DIN rail locking screw is in the horizontal position before module insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Safety:\u003c\/strong\u003e Ensure field-side power and backplane power are removed before inserting or removing the module or terminal block in hazardous locations to prevent electrical arcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Power the equipment from a SELV or PELV compliant source to comply with CE Low Voltage Directive requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed Industrial Control Equipment (UL File E65584)\u003c\/li\u003e\n\u003cli\u003eUL Listed for Class I Division 2 Group A, B, C, D Hazardous Locations (UL File E194810, Temp Code T4A)\u003c\/li\u003e\n\u003cli\u003eUKEX \/ ATEX: II 3 G Ex ec IIC T4 Gc (DEMKO 04 ATEX 0330347X, UL22UKEX2478X)\u003c\/li\u003e\n\u003cli\u003eIECEx: Ex ec IIC T4 Gc (IECEx UL 20.0072X)\u003c\/li\u003e\n\u003cli\u003eCE \/ UKCA EMC: EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2\u003c\/li\u003e\n\u003cli\u003eRoHS: EN IEC 63000\u003c\/li\u003e\n\u003cli\u003eRCM, KC, CCC (202012230911607)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53609911189867,"sku":"1734-IB4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1734-IB4_2.jpg?v=1785027090"},{"product_id":"allen-bradley-1734-ob4e-point-i-o-4-point-digital-output-module","title":"Allen-Bradley 1734-OB4E Point I\/O 4-Point Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1734-OB4E\u003c\/strong\u003e is a 24V DC 4-channel sourcing digital output module designed for use within the Allen-Bradley POINT I\/O system. The \u003cstrong\u003e1734-OB4E\u003c\/strong\u003e features 4 non-isolated, electronically protected outputs organized into a single group. Operating on a nominal 24V DC external power supply, the module provides short circuit and overload protection for connected field loads. The module interfaces across industrial networks using DeviceNet, PROFIBUS, ControlNet, or EtherNet\/IP adapters, making it suitable for distributed I\/O applications controlling field devices such as solenoids, relays, and indicators.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 non-isolated sourcing digital output channels in one group\u003c\/li\u003e\n\u003cli\u003eElectronically protected outputs for short circuit and overload conditions\u003c\/li\u003e\n\u003cli\u003eKeyswitch position 1 for mechanical keying on compatible terminal bases\u003c\/li\u003e\n\u003cli\u003eLogic-driven status indicators including 4 yellow output status LEDs, 4 red output fault LEDs, and 2 green\/red module\/network status LEDs\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block (RTB) support allowing module replacement without disturbing field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O processing on DeviceNet and PROFIBUS networks\u003c\/li\u003e\n\u003cli\u003eControl system expansion via EtherNet\/IP and ControlNet adapters\u003c\/li\u003e\n\u003cli\u003eSwitching 24V DC industrial loads including actuators, relays, and solenoids\u003c\/li\u003e\n\u003cli\u003eClass I Division 2, Zone 2 hazardous location installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB4E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4 (1 group of 4), non-isolated, sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage, Min\u003c\/td\u003e\n\u003ctd\u003e10V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage, Nom\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage, Max\u003c\/td\u003e\n\u003ctd\u003e28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop, Max\u003c\/td\u003e\n\u003ctd\u003e0.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current, Min\u003c\/td\u003e\n\u003ctd\u003e1.0 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage, Max\u003c\/td\u003e\n\u003ctd\u003e0.5 mA @ 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Delay, Off to On \/ On to Off\u003c\/td\u003e\n\u003ctd\u003e0.1 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating, Per Output\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating, Max Per Module\u003c\/td\u003e\n\u003ctd\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e2 A for 10 ms, repeatable every 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power Supply Voltage, Nom\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10...28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal DC Power Supply Current\u003c\/td\u003e\n\u003ctd\u003e16 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current, Max\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation @ 28.8V DC, Max\u003c\/td\u003e\n\u003ctd\u003e1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation @ 28.8V DC, Max\u003c\/td\u003e\n\u003ctd\u003e4.1 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V (continuous), reinforced insulation type, tested @ 2500V DC for 60 s field-side to system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wiring Base Assemblies\u003c\/td\u003e\n\u003ctd\u003e1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS, 1734-TB3, 1734-TB3S, 1734-TOP3, 1734-TOP3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyswitch Position\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.8 N-m (7 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20...55 degC (-4...131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degC (-40...+185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock, Operating \/ Nonoperating\u003c\/td\u003e\n\u003ctd\u003e30 g \/ 50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Approx.\u003c\/td\u003e\n\u003ctd\u003e33.17 g (1.17 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598205288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Lead Time\u003c\/td\u003e\n\u003ctd\u003e5 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCA Method\u003c\/td\u003e\n\u003ctd\u003eISO 14040\/44 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Assessment Method\u003c\/td\u003e\n\u003ctd\u003eEF 3.0 (Environmental Footprint) ESPR aligned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatabase Used\u003c\/td\u003e\n\u003ctd\u003eEcoinvent 3.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse Phase Electricity\u003c\/td\u003e\n\u003ctd\u003eEuropean Average Grid Mix (EU-40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCradle To Gate\u003c\/td\u003e\n\u003ctd\u003e3.73E+00 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCradle To Grave\u003c\/td\u003e\n\u003ctd\u003e7.14E+01 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eChannel 0 Output Terminal (Out 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Output Terminal (Out 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Output Terminal (Out 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eChannel 3 Output Terminal (Out 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eCommon Terminal (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eCommon Terminal (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eCommon Terminal (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eCommon Terminal (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Grounding:\u003c\/strong\u003e Ground the module through the DIN rail to chassis ground using zinc-plated chromate-passivated steel DIN rail (Allen-Bradley part number 199-DR1; 46277-3; EN50022). Secure the DIN rail to the mounting surface approximately every 200 mm (7.8 in.) and use end-anchors properly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirement:\u003c\/strong\u003e Mount the module inside a Pollution Degree 2 industrial enclosure that meets overvoltage Category II applications. Enclosures must require a tool for interior access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyswitch Setting:\u003c\/strong\u003e Set the orange keyswitch on the mounting base to position 1 by rotating clockwise with a bladed screwdriver prior to inserting the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Ensure the DIN rail locking screw is in the horizontal position before inserting the module straight down into the mounting base until it locks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Safety:\u003c\/strong\u003e Remove power or ensure the area is nonhazardous before inserting or removing the module or connecting\/disconnecting the removable terminal block (RTB) or wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Limits:\u003c\/strong\u003e Do not wire more than two conductors on any single terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL-us (UL Listed Industrial Control Equipment File E65584; UL Listed for Class I Division 2 Group A,B,C,D Hazardous Locations File E194810)\u003c\/li\u003e\n\u003cli\u003eUK and CE (EMC Directive 2014\/30\/EU, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; RoHS Directive 2011\/65\/EU, EN IEC 63000)\u003c\/li\u003e\n\u003cli\u003eRCM (EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eEx (ATEX Directive 2014\/34\/EU, EN IEC 60079-0, EN IEC 60079-7, II 3G Ex nA IIC T4 Gc, DEMKO 04 ATEX 0330347X, UL22UKEX2478X)\u003c\/li\u003e\n\u003cli\u003eKC (Article 58-2 of Radio Waves Act, Clause 3)\u003c\/li\u003e\n\u003cli\u003eIECEx (IEC 60079-0, IEC 60079-7, Ex ec IIC T4 Gc, IECEx UL 20.0072X)\u003c\/li\u003e\n\u003cli\u003eMorocco (Arrêté ministériel nº 6404-15)\u003c\/li\u003e\n\u003cli\u003eCCC (CNCA-C23-01 CCC: 2020122309111607)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53609914204523,"sku":"1734-OB4E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1734-OB4E_1.jpg?v=1785028116"},{"product_id":"allen-bradley-1734-ie2c-point-i-o-2-point-analog-input-module","title":"Allen Bradley 1734-IE2C Point I\/O 2 Point Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003e1734-IE2C\u003c\/strong\u003e is a 2-channel analog current input module designed for integration within the POINT I\/O system architecture. The \u003cstrong\u003e1734-IE2C\u003c\/strong\u003e provides conversion of 4...20 mA and 0...20 mA field signals into 16-bit digital representation for process control systems. The unit sends 6 bytes of input data and fault status information across the backplane to the system controller, operating via DeviceNet, PROFIBUS, ControlNet, or EtherNet\/IP adapters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 2 single-ended, non-isolated current input channels.\u003c\/li\u003e\n\u003cli\u003eSupports configurable analog input ranges of 4...20 mA and 0...20 mA.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 16-bit analog-to-digital conversion (0.32 uA\/cnt) using Delta Sigma conversion.\u003c\/li\u003e\n\u003cli\u003eBuilt-in channel status and fault indicators for local diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eRemovable Terminal Block (RTB) compatibility allows module replacement without disconnecting field wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated fault protection up to 28.8V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process automation and monitoring\u003c\/li\u003e\n\u003cli\u003e4...20 mA transmitter signal integration\u003c\/li\u003e\n\u003cli\u003eFactory automation control systems using POINT I\/O architectures\u003c\/li\u003e\n\u003cli\u003eRemote I\/O field signal acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-IE2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 g (1.16 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 single-ended, non-isolated, current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4...20 mA, 0...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits - over 0...21 mA (0.32 uA\/cnt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelta Sigma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance \/ Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 degC (77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Drift with Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Filter Time Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...10,000 ms (default = 0 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 ms @ Notch = 50 Hz, 100 ms @ Notch = 60 Hz (default), 24 ms @ Notch = 250 Hz, 12 ms @ Notch = 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault protected to 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC nominal (10...28.8V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Power Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOINTBus Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W @ 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 BTU\/hr @ 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V continuous (tested to withstand 2550V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Base Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 N-m (7 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25...2.5 mm2 (22...14 AWG) solid or stranded shielded copper wire rated at 75 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +55 degC (-4 degF to +131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eCurrent Input Channel 0 (In 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eCurrent Input Channel 1 (In 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas Gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas Gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Base Alignment\u003c\/strong\u003e: Mount the module into a compatible POINT I\/O base assembly (1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-TOP3, or 1734-TOP3S). Set the keyswitch to position 3 prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Grounding\u003c\/strong\u003e: Install onto a zinc-plated chromate-passivated steel DIN rail to ensure proper chassis grounding. Secure the DIN rail every 200 mm (7.8 in.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements\u003c\/strong\u003e: Mount in an open-style industrial enclosure rated for Pollution Degree 2 environments and compliant with specific application requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e: Touch a grounded object or wear an approved grounding wrist strap before handling the electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practices\u003c\/strong\u003e: Use shielded copper wire rated for 75 degC or higher with a maximum insulation thickness of 1.2 mm (3\/64 in.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us\u003c\/strong\u003e: UL Listed Industrial Control Equipment (UL File E65584); UL Listed for Class I Division 2 Groups A, B, C, D Hazardous Locations (UL File E194810).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUK \/ CE\u003c\/strong\u003e: Compliant with EMC Directive (2014\/30\/EU), LVD (2014\/35\/EU), and RoHS Directive (2011\/65\/EU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e: II 3G Ex ec IIC T4 Gc (DEMKO 04 ATEX 0330347X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKEX\u003c\/strong\u003e: UL22UKEX2478X.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e: IECEx UL 20.0072X (Ex ec IIC T4 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM\u003c\/strong\u003e: Compliant with Australian Radiocommunications Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC\u003c\/strong\u003e: Korean Registration of Broadcasting and Communications Equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC\u003c\/strong\u003e: CNCA-C23-01 Certified Explosion-Proof Electrical Product (2020122309111607).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53610021552491,"sku":"1734-IE2C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1734-IE2.jpg?v=1785028736"},{"product_id":"allen-bradley-1734-oe2c-point-i-o-analog-current-output-module","title":"Allen-Bradley 1734-OE2C POINT I\/O Analog Current Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1734-OE2C\u003c\/strong\u003e is a 24V DC, 2-channel analog current output module designed for the Allen-Bradley POINT I\/O system. The unit converts digital output data into 4...20 mA or 0...20 mA analog current signals to control field devices in industrial automation environments. Operating via the internal field power bus, the module produces 2 bytes of input data with fault status information and consumes 4 bytes of output data across the backplane. It communicates via DeviceNet, PROFIBUS, ControlNet, or EtherNet\/IP adapters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 2 single-ended, non-isolated analog current outputs.\u003c\/li\u003e\n\u003cli\u003eField-configurable output ranges of 4...20 mA or 0...20 mA.\u003c\/li\u003e\n\u003cli\u003e13-bit output resolution over 0...21 mA.\u003c\/li\u003e\n\u003cli\u003eFeatures local status indicators for module status, network status, and individual output channel status.\u003c\/li\u003e\n\u003cli\u003eMounts into compatible two-piece or one-piece POINT I\/O terminal bases.\u003c\/li\u003e\n\u003cli\u003eSupports removable terminal blocks (RTB) to allow module replacement without disconnecting field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process automation and field device control\u003c\/li\u003e\n\u003cli\u003eCurrent loop signal generation (0...20 mA \/ 4...20 mA)\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O systems using POINT I\/O architecture\u003c\/li\u003e\n\u003cli\u003eControl valve and actuator positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-OE2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e612598205295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 g (1.27 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 single-ended, non-isolated, current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...20 mA, 4...20 mA (user configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 bits over 0...21 mA (2.5 uA\/cnt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% full scale @ 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Drift with Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep Response to 63% of FS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistive Load on Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...750 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital to analog converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory-calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Terminal Bases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-TOP3, 1734-TOP3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Base Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 N-m (7 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOINTBus Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.23 W (750 ohm load), 1.83 W (0 ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.19 BTU\/hr (750 ohm load), 6.24 BTU\/hr (0 ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V Continuous (Tested to withstand 2200V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal External DC Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Power Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mA @ 24V DC (including outputs @ 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25...2.5 mm2 (22...14 AWG) solid or stranded copper wire rated at 75 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +55 degC (-4 degF to +131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurrounding Air Temperature (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 degC (131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eCurrent Output Channel 0 (Out 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eCurrent Output Channel 1 (Out 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e24V DC Nominal Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e24V DC Nominal Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount the assembly onto a zinc-plated chromate-passivated steel DIN rail to maintain appropriate chassis grounding. Anchor the DIN rail approximately every 200 mm (7.8 in.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyswitch Configuration\u003c\/strong\u003e: Set the mechanical keyswitch on the terminal base to position 4 prior to installing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Locking Screw\u003c\/strong\u003e: Ensure the DIN rail locking screw is in the horizontal position before attempting module installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD) Prevention\u003c\/strong\u003e: Discharge static electricity by touching a grounded object or wearing an approved grounding wriststrap prior to handling module components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Requirements\u003c\/strong\u003e: Maintain a minimum clearance of 2.54 cm (1.0 in.) above the module for proper ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements\u003c\/strong\u003e: Use 0.25...2.5 mm2 (22...14 AWG) shielded copper wire rated for at least 75 degC with a maximum insulation thickness of 1.2 mm (3\/64 in.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us\u003c\/strong\u003e: UL Listed Industrial Control Equipment (UL File E65584); UL Listed for Class I Division 2 Groups A, B, C, D Hazardous Locations (UL File E194810).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUK \/ CE\u003c\/strong\u003e: Compliant with EMC Directives (EN 61326-1, EN 61000-6-2, EN 61000-6-4), Programmable Controllers (EN 61131-2), and RoHS (EN IEC 63000).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx \/ ATEX\u003c\/strong\u003e: EN IEC 60079-0, EN IEC 60079-7; II 3G Ex ec IIC T4 Gc (DEMKO 04 ATEX 0330347X, UL22UKEX2478X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e: IEC 60079-0, IEC 60079-7; Ex ec IIC T4 Gc (IECEx UL 20.0072X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM\u003c\/strong\u003e: Compliant with Australian Radiocommunications Act (EN 61000-6-4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC\u003c\/strong\u003e: Korean Registration of Broadcasting and Communications Equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMorocco\u003c\/strong\u003e: Arrête ministériel n° 6404-15.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC\u003c\/strong\u003e: CNCA-C23-01 Implementation Rule Explosion-Proof Electrical Products (CCC 2020122309111607).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53610045768043,"sku":"1734-OE2C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1734-OE2C.jpg?v=1785029293"}],"url":"https:\/\/www.plcprotech.com\/uz\/collections\/allen-bradley-point-i-o-1734.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}