{"title":"Basler Electric","description":"\u003cp\u003eQuvvat tizimlarini boshqarish va himoya qilishda tengsiz ishonchlilik uchun ishlab chiqilgan original Basler Electric mahsulotlarining premium tanlovini o‘rganing. Ilg‘or avtomatik kuchlanish regulyatorlari (AVR) va qo‘zg‘atish tizimlaridan tortib, aniq himoya relelarigacha, Basler Electric elektr energiyasini ishlab chiqarishni optimallashtirish, tizim barqarorligini oshirish va uzluksiz ishlashni ta’minlash uchun mo‘ljallangan yuqori samarali yechimlarni taqdim etadi. Sanoat va tijoriy ilovalaringizni ishonchli, sohada yetakchi elektr uskunalari bilan jihozlash uchun hoziroq xarid qiling.\u003c\/p\u003e","products":[{"product_id":"basler-electric-decs-250-ln2sn1n-digital-excitation-control-system","title":"Basler Electric DECS-250-LN2SN1N Digital Excitation Control System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBasler Electric DECS-250-LN2SN1N\u003c\/strong\u003e is a digital excitation control system designed for precise voltage, var, and power factor regulation of synchronous generators and motors. The \u003cstrong\u003eDECS-250-LN2SN1N\u003c\/strong\u003e configuration integrates a 24\/48 Vac\/Vdc power supply, internal and external autotracking capabilities, spring type terminals, and a 100Base-T Ethernet communication interface.\u003c\/p\u003e\n\u003cp\u003eEquipped with a pulse-width-modulated (PWM) power stage delivering up to 15 Adc full-load continuous current, the system supports 1-phase or 3-phase true RMS sensing for voltage and current, integrated generator protection, auto-tuning stability controls, and diagnostic logging. Built-in communication interfaces include USB, RS-232, RS-485, CAN bus, and 100Base-T Ethernet for unit-to-unit communication and system setup via BESTCOMSPlus software.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete excitation control supporting Automatic Voltage Regulation (AVR), Field Current Regulation (FCR), Field Voltage Regulation (FVR), Power Factor (PF), and var operating modes\u003c\/li\u003e\n\u003cli\u003eTrue RMS single-phase or three-phase generator and bus voltage sensing\u003c\/li\u003e\n\u003cli\u003eFull generator metering and integrated generator protection functions (27\/59, 81O\/U, 32R, 40Q, EDM, 59F, 51F, Loss of PMG, Field Short Circuit, and 25 Sync Check)\u003c\/li\u003e\n\u003cli\u003ePulse-width-modulated (PWM) power stage adaptable to shunt, auxiliary winding, permanent magnet, or DC-fed systems\u003c\/li\u003e\n\u003cli\u003eAuto-tuning feature with two PID stability groups\u003c\/li\u003e\n\u003cli\u003eOverexcitation, underexcitation, stator current, var, and underfrequency \/ V\/Hz limiters\u003c\/li\u003e\n\u003cli\u003eInternal and external autotracking capabilities\u003c\/li\u003e\n\u003cli\u003eLoad sharing over Ethernet and Modbus TCP protocol\u003c\/li\u003e\n\u003cli\u003eConformal-coated internal circuitry for enhanced environmental protection\u003c\/li\u003e\n\u003cli\u003eIntegrated trending, oscillography, and sequence of events recording\u003c\/li\u003e\n\u003cli\u003eCompatible with AEM-2020 Analog Expansion Module and CEM-2020 Contact Expansion Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSynchronous generator excitation control\u003c\/li\u003e\n\u003cli\u003eSynchronous motor excitation control\u003c\/li\u003e\n\u003cli\u003eIndustrial power generation plants\u003c\/li\u003e\n\u003cli\u003eUtility grid-connected power generation facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eStyle Code Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e24\/48 Vac\/Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutotracking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eInternal\/external autotracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003eSpring type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronizer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1st Communication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100Base-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2nd Communication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasler Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDECS-250-LN2SN1N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Excitation Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage (Style L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to 60 Vdc \/ 24\/48 Vac\/Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Burden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 VA or 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Load Continuous Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-Second Forcing Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator \u0026amp; Bus Voltage Sensing Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/120 Vac +\/-10%, 200\/240 Vac +\/-10%, 400\/480 Vac +\/-10%, 600 Vac +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Current Sensing Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Aac or 5 Aac nominal, 50\/60 Hz nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 programmable inputs (dry contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 programmable form A contacts, 1 form C contact (watchdog function); rating 7 A resistive @ 24\/48\/125 Vdc \/ 120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA or +\/-10 Vdc input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB type B, RS-232 (9-pin sub D), RS-485 (Modbus RTU), CAN bus, Expansion Port, 100Base-T Ethernet (Modbus TCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 70 degC (-40 degF to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC (-40 degF to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 G in three perpendicular planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G from 18 to 2000 Hz in three perpendicular planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6 lb (6.62 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.62 in x 12.00 in x 6.26 in (219.0 mm x 304.8 mm x 159.0 mm) (D x H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure proper panel mounting with adequate clearance around the enclosure to facilitate airflow and heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Wire dry contact inputs, output contacts, sensing inputs, and power leads to the spring-type terminal connectors in accordance with system schematics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Use shielded twisted-pair cabling for analog inputs, auxiliary signals, and communication lines to mitigate EMI\/RFI noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Connections:\u003c\/strong\u003e Connect Ethernet cables to the 100Base-T port for network communication or unit-to-unit load sharing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA certified\u003c\/li\u003e\n\u003cli\u003eUL recognized\u003c\/li\u003e\n\u003cli\u003eCE EMC and LVD compliant\u003c\/li\u003e\n\u003cli\u003eEAC certified\u003c\/li\u003e\n\u003cli\u003eBureau Veritas (BV) recognized\u003c\/li\u003e\n\u003cli\u003eDet Norske Veritas-Germanischer Lloyd (DNV GL) recognized\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping (ABS) recognized\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Basler Electric","offers":[{"title":"Default Title","offer_id":53643942461803,"sku":"DECS-250-LN2SN1N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DECS-250-LN2SN1N_1.jpg?v=1785588023"},{"product_id":"basler-electric-decs-200-2l-digital-excitation-control-system","title":"Basler Electric DECS-200-2L Digital Excitation Control System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBasler Electric DECS-200-2L\u003c\/strong\u003e is a total digital excitation control system packaged in a single enclosure, designed to control the output voltage, vars, or power factor of synchronous generators by varying DC excitation applied to the exciter field. Operating with 15 Adc continuous rated output across 32 Vdc, 63 Vdc, or 125 Vdc excitation applications, this unit incorporates a pulse-width-modulated (PWM) power stage to deliver regulation stability under non-linear load conditions. The \u003cstrong\u003eDECS-200-2L\u003c\/strong\u003e style configuration specifies external and internal autotracking functionality paired with a 24\/48 Vdc control power supply.\u003c\/p\u003e\n\u003cp\u003eEquipped with a microprocessor-based architecture, the device provides true RMS single- or three-phase sensing for generator voltage, bus voltage, and generator currents. Integrated features include multiple operating modes (Automatic Voltage Regulation, Field Current Regulation, var, and Power Factor modes), soft start voltage buildup, limiters, generator protection functions, sequence of events recording, and oscillography. Local operator interface is provided via a front-panel backlit LCD display, six navigation pushbuttons, status LEDs, and an RS-232 serial port, with an additional RS-485 port supporting Modbus RTU network communication up to 4,000 feet.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-based digital regulation with 0.25% voltage regulation accuracy\u003c\/li\u003e\n\u003cli\u003eTrue RMS single-phase or three-phase sensing for generator voltage and bus voltage\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes: Automatic Voltage Regulation (AVR), Field Current Regulation (FCR\/Manual Mode), var control, and Power Factor (PF) control\u003c\/li\u003e\n\u003cli\u003eExternal and internal autotracking for bumpless mode transfers and dual-unit tracking\u003c\/li\u003e\n\u003cli\u003ePulse-width-modulated (PWM) power stage delivering up to 15 Adc continuous output\u003c\/li\u003e\n\u003cli\u003eConfigurable Underfrequency compensation or Volts\/Hz Ratio Limiter\u003c\/li\u003e\n\u003cli\u003eProgrammable Soft Start voltage buildup with adjustable rate from 1 to 7200 seconds\u003c\/li\u003e\n\u003cli\u003eIntegrated limiter controls including Minimum Excitation Limiter (UEL), On-line\/Off-line Maximum Excitation Limiters (OEL), and Stator Current Limiter (SCL)\u003c\/li\u003e\n\u003cli\u003eExciter Diode Monitoring (EDM) for open and shorted diode detection on brushless generators\u003c\/li\u003e\n\u003cli\u003eEight integrated generator protective functions with adjustable trip thresholds and time delays\u003c\/li\u003e\n\u003cli\u003eSequence of Events Recording (SER) storing up to 127 event reports with date and time stamps\u003c\/li\u003e\n\u003cli\u003eOscillography data recording capturing up to 8 records and 6 selectable variables\u003c\/li\u003e\n\u003cli\u003eFront panel LCD with 64x128 pixel graphic display, navigation pushbuttons, and status LEDs\u003c\/li\u003e\n\u003cli\u003eDual RS-232 ports and one RS-485 port with Modbus protocol support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSynchronous generator excitation voltage regulation\u003c\/li\u003e\n\u003cli\u003eUtility grid-connected generator var and power factor control\u003c\/li\u003e\n\u003cli\u003eDual-redundant backup generator excitation systems\u003c\/li\u003e\n\u003cli\u003eIndustrial power generation facility generator control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eStyle Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eExternal\/Internal autotracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e24\/48 Vdc control power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasler Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDECS-200-2L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power Input Voltage (Style L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to 60 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power Burden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (32 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Vac nominal, 56 to 70 Vac +\/-10%, 1 or 3 Phase, 50 to 500 Hz, 780 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (63 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Vac nominal, 100 to 139 Vac +\/-10%, 1 or 3 Phase, 50 to 500 Hz, 1570 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (125 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 Vac nominal, 190 to 277 Vac +\/-10%, 1 or 3 Phase, 50 to 500 Hz, 3070 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Voltage Buildup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Field Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-Second Forcing Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Field Output Voltage (32 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Vdc continuous, 50 Vdc 10-sec forcing, 2.13 Ohm min field resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Field Output Voltage (63 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 Vdc continuous, 100 Vdc 10-sec forcing, 4.2 Ohm min field resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Field Output Voltage (125 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 Vdc continuous, 200 Vdc 10-sec forcing, 8.3 Ohm min field resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Voltage Sensing Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100V\/50Hz (85 to 127V), 120V\/60Hz (94 to 153V), 200V\/50Hz (170 to 254V), 240V\/60Hz (187 to 305V), 400V\/50Hz (340 to 508V), 480V\/60Hz (374 to 600V), 500V\/50Hz (425 to 625V), 600V\/60Hz (510 to 660V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Voltage Sensing Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100V\/50Hz (85 to 127V), 120V\/60Hz (94 to 153V), 200V\/50Hz (170 to 254V), 240V\/60Hz (187 to 305V), 400V\/50Hz (340 to 508V), 480V\/60Hz (374 to 600V), 500V\/50Hz (425 to 625V), 600V\/60Hz (510 to 660V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Current Sensing Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Aac and 5 Aac for metering\/control; 1 Aac and 5 Aac for cross current compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Burden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026lt;0.1 VA per phase; Current: \u0026lt;1 VA; Parallel Compensation: \u0026lt;1 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Switching Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 inputs supplied with 24 Vdc for dry contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Set Point Auxiliary Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable +10 Vdc or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Output Carry Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 A resistive @ 24\/48\/125 Vdc \/ 120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Output Make\/Break Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 A @ 24 Vdc, 0.7 A @ 48 Vdc, 0.2 A @ 125 Vdc, 7.0 A @ 120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAVR Regulation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% over load range at rated power factor and constant frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAVR Steady State Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% at constant load and frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAVR Temperature Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% for 0 to 50 degC change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCR Regulation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-1.0% of nominal value for 10% input voltage or 20% field resistance change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003evar Regulation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-2.0% of nominal VA rating at rated frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePF Regulation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.02 PF for real power between 10% and 100% at rated frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC (-40 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalt Fog Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer MIL-STD-810E, Method 509.3 (100 hrs salt fog, 100 hrs drying)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Gs in each of three mutually perpendicular planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-26 Hz: 1.2 Gs; 27-52 Hz: 0.914 mm (.036 in) double amplitude; 53-500 Hz: 5.0 Gs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0 in x 8.08 in x 6.76 in (304 mm x 205 mm x 171 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 lbs (6.35 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM0 (Front Panel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232, 9-pin sub-D connector, ASCII commands, 1200 to 19200 baud for local PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM1 (Right Side Panel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232, 9-pin sub-D connector, autotracking port for dual DECS-200 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM2 (Left Side Panel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485, Modbus protocol, 1200 to 19200 baud, half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB7 \/ B8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Control Power Input (BATT+ \/ BATT-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB9 \/ B10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Control Input (L \/ N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC1 \/ C2 \/ C3 \/ C4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Power Input (GND \/ A \/ B \/ C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC5 \/ C6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExciter Field Output (F+ \/ F-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1 \/ A2 \/ A3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Sensing Inputs (E1 \/ E2 \/ E3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB1 \/ B2 \/ B3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Sensing Inputs (CTB 1 AMP \/ 5 AMP \/ COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB4 \/ B5 \/ B6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eParalleling CT Cross Current Sensing (CTCC 1 AMP \/ 5 AMP \/ COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA4 \/ B1 \/ A5 \/ B3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus Voltage Matching Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA6 \/ A7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Current Input (4-20 mAdc, I+ \/ I-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA8 \/ A9 \/ A10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Voltage Input (+\/-10 Vdc, GND \/ V+ \/ V-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA11 \/ A12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Stop \/ Start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA13 \/ A14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Output: Watchdog Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA15 \/ A16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Output: Programmable Relay #1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA17 \/ A18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Output: Programmable Relay #2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA19 \/ A20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Output: Programmable Relay #3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA21 \/ A22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Start Command\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA23 \/ A24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Stop Command\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA25 \/ A26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: AVR Regulation Mode Select\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA27 \/ A28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: FCR Field Current Regulation Mode Select\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA29 \/ A30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Active Mode Raise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA31 \/ A32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Active Mode Lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA33 \/ A34\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Pre-Position Close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA35 \/ A36\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Unit \/ Parallel Contact (52 L\/M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA37 \/ A38\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Var \/ PF Control (52 J\/K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA39 \/ A40\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Enable Unit as Secondary (SECEN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA41 \/ A42\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Input: Alarm Reset (ALRST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA43 \/ A44 \/ A45\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 Output Terminals (A \/ B \/ C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Source Isolation:\u003c\/strong\u003e When using dual AC control power sources, install a Control Power Isolation Transformer (Basler P\/N BE31449-001) on the AC control power input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Mitigation:\u003c\/strong\u003e When energizing the system from a source already at rated power input voltage level, connect an Inrush Current Reduction Module (ICRM-15) to limit inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant System Freewheeling Diode:\u003c\/strong\u003e Install a DECS Freewheeling Diode Module (Basler P\/N 9293600101) when implementing dual DECS-200 redundant configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Mount the enclosure using the six 0.281 in (7.1 mm) diameter clearance holes or use the optional Front Panel Mounting Bracket (Basler P\/N 9360107100).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransformer Requirements:\u003c\/strong\u003e Ensure potential transformers are installed on voltage sensing inputs if the line voltage exceeds 600 Vac.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Attach chassis ground to terminal C1 and utilize shielded twisted-pair conductors for low-level analog accessory inputs (+\/-10 Vdc or 4-20 mA) and communication channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized per Std. 508 (UL File Number E97035)\u003c\/li\u003e\n\u003cli\u003eCSA Certified per Std. CAN\/CSA-C22.2, Number 14 (CSA File Number LR23131)\u003c\/li\u003e\n\u003cli\u003eCE Compliant (EMC and LVD directives)\u003c\/li\u003e\n\u003cli\u003eCertified per DNV Standard 2.4\u003c\/li\u003e\n\u003cli\u003eGOST-R Certified (Gosstandart of Russia)\u003c\/li\u003e\n\u003cli\u003eByelorussian Certified\u003c\/li\u003e\n\u003cli\u003eIEEE C37.90.1-1989 Surge Withstand Capability (SWC) and Fast Transient\u003c\/li\u003e\n\u003cli\u003eIEEE 421.3 High Pot\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Basler Electric","offers":[{"title":"Default Title","offer_id":53643969397099,"sku":"DECS-200-2L","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DECS-200-2L_1.jpg?v=1785588706"},{"product_id":"basler-electric-decs-200-1l-digital-excitation-control-system","title":"Basler Electric DECS-200-1L Digital Excitation Control System","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBasler Electric DECS-200-1L\u003c\/strong\u003e Digital Excitation Control System provides precision excitation control for synchronous generators by regulating the direct current applied to the generator exciter field. Equipped with a pulse width modulated (PWM) power stage, the system delivers high performance across non-linear load applications and supports output capabilities of 32 Vdc, 63 Vdc, or 125 Vdc at up to 15 Adc. Operating modes include Automatic Voltage Regulation (AVR) with 0.25% accuracy, Field Current Regulation (FCR\/Manual mode), Var control, and Power Factor (PF) control.\u003c\/p\u003e\n\u003cp\u003eThe controller features true RMS single- or three-phase sensing for generator voltage, bus voltage matching, and generator current. Interface options consist of contact inputs, proportional ±10 Vdc or 4–20 mA inputs, a front-panel RS-232 port (COM0), a side RS-232 port for unit autotracking (COM1), and a side RS-485 port supporting Modbus RTU protocol (COM2). Integrated machine protection capabilities include generator overvoltage\/undervoltage, field overvoltage\/overcurrent, loss of sensing, loss of field, exciter diode monitoring (EDM), and overexcitation\/underexcitation limiting.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-based digital excitation control with pulse width modulated power stage\u003c\/li\u003e\n\u003cli\u003eSingle or three-phase true RMS sensing for generator and bus voltage\u003c\/li\u003e\n\u003cli\u003e0.25% voltage regulation accuracy over the load range\u003c\/li\u003e\n\u003cli\u003eFour operating modes: Automatic Voltage Regulation (AVR), Field Current Regulation (FCR), Var control, and Power Factor (PF) control\u003c\/li\u003e\n\u003cli\u003eInternal autotracking between modes for bumpless transfers\u003c\/li\u003e\n\u003cli\u003e20 standard preprogrammed stability selections and user customizable PID settings\u003c\/li\u003e\n\u003cli\u003eUnderfrequency compensation or V\/Hz ratio limiter with adjustable corner frequency\u003c\/li\u003e\n\u003cli\u003eSoft start voltage buildup with adjustable time rates\u003c\/li\u003e\n\u003cli\u003eReactive droop and reactive differential (cross-current) paralleling compensation\u003c\/li\u003e\n\u003cli\u003eIntegrated Exciter Diode Monitoring (EDM) for detecting open and shorted diodes\u003c\/li\u003e\n\u003cli\u003eSequence of Events Recording (SER) storing up to 127 event reports\u003c\/li\u003e\n\u003cli\u003eIntegrated COMTRADE-compliant oscillography logging up to 8 records\u003c\/li\u003e\n\u003cli\u003eFront panel HMI with backlit LCD display, programming keys, and diagnostic LEDs\u003c\/li\u003e\n\u003cli\u003eMultiple communication ports: RS-232 front (COM0), RS-232 side (COM1), and RS-485 side (COM2) with Modbus protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExcitation voltage and current regulation for synchronous generators\u003c\/li\u003e\n\u003cli\u003eUtility paralleling power generation systems requiring Var or Power Factor control\u003c\/li\u003e\n\u003cli\u003eBrushless generator exciter field control with diode health monitoring\u003c\/li\u003e\n\u003cli\u003eGenerator protection and overexcitation\/underexcitation limiting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTracking Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePower Supply Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDECS-200-1L\u003c\/td\u003e\n\u003ctd\u003e1 (Internal autotracking)\u003c\/td\u003e\n\u003ctd\u003eL (24\/48 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasler Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDECS-200-1L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-60 Vdc (24\/48 Vdc nominal, Style L), Burden = 30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (32 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Vac nominal (56-70 Vac +\/-10%), 1 or 3 phase, 50-500 Hz, 780 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (63 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Vac nominal (100-139 Vac +\/-10%), 1 or 3 phase, 50-500 Hz, 1570 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Operating Power Input (125 Vdc Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 Vac nominal (190-277 Vac +\/-10%), 1 or 3 phase, 50-500 Hz, 3070 VA burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Continuous Field Voltage Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Vdc, 63 Vdc, or 125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Continuous Field Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated 10-Second Forcing Voltage Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Vdc (32 Vdc mode), 100 Vdc (63 Vdc mode), 200 Vdc (125 Vdc mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated 10-Second Forcing Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Field Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.13 Ohms (32 Vdc), 4.2 Ohms (63 Vdc), 8.3 Ohms (125 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Voltage Sensing Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 3 phase, ranges: 100V\/50Hz (85-127V), 120V\/60Hz (94-153V), 200V\/50Hz (170-254V), 240V\/60Hz (187-305V), 400V\/50Hz (340-508V), 480V\/60Hz (374-600V), 500V\/50Hz (425-625V), 600V\/60Hz (510-660V); Burden \u0026lt; 0.1 VA\/phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Voltage Sensing Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 phase, ranges: 100V\/50Hz (85-127V), 120V\/60Hz (94-153V), 200V\/50Hz (170-254V), 240V\/60Hz (187-305V), 400V\/50Hz (340-508V), 480V\/60Hz (374-600V), 500V\/50Hz (425-625V), 600V\/60Hz (510-660V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Current Sensing Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1A and 5A AC ranges ( metering\/control \u0026amp; cross current compensation); Burden \u0026lt; 1 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 dry contact switching inputs supplied with 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Remote Set Point Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable +\/-10 Vdc or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistive: 7.0 A at 24 Vdc, 0.7 A at 48 Vdc, 0.2 A at 125 Vdc, 7.0 A at 120\/240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAVR Regulation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% over load range at rated power factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC (-40 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalt Fog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer MIL-STD-810E, Method 509.3 (100 hrs salt fog, 100 hrs drying)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Gs in three mutually perpendicular planes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-26Hz: 1.2Gs; 27-52Hz: 0.914mm double amplitude; 53-500Hz: 5.0Gs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 mm x 205 mm x 171 mm (12.0 in x 8.08 in x 6.76 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.35 kg (14 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBATT+ (B7)\u003c\/td\u003e\n\u003ctd\u003eDC Control Power Input (+24\/48 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBATT- (B8)\u003c\/td\u003e\n\u003ctd\u003eDC Control Power Input (-24\/48 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL (B9)\u003c\/td\u003e\n\u003ctd\u003eAC Control Power Input Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN (B10)\u003c\/td\u003e\n\u003ctd\u003eAC Control Power Input Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC (C4), B (C3), A (C2), GND (C1)\u003c\/td\u003e\n\u003ctd\u003eInput Operating Power Connections and Chassis Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1 (A1), E2 (A2), E3 (A3)\u003c\/td\u003e\n\u003ctd\u003eVoltage Sensing Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCTB 1AMP (B1), CTB 5AMP (B2), CTB COM (B3)\u003c\/td\u003e\n\u003ctd\u003eCurrent Sensing Channel B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCTCC 1AMP (B4), CTCC 5AMP (B5), CTCC COM (B6)\u003c\/td\u003e\n\u003ctd\u003eCross Current Compensation Sensing Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA5, B3, A4, B1\u003c\/td\u003e\n\u003ctd\u003eBus Voltage Matching Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF+ (C5), F- (C6)\u003c\/td\u003e\n\u003ctd\u003eExciter Field Power Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA6, A7\u003c\/td\u003e\n\u003ctd\u003e4-20 mAdc Auxiliary Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA8, A9, A10\u003c\/td\u003e\n\u003ctd\u003e+\/-10 Vdc Auxiliary Analog Input (GND, V+, V-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA11, A12\u003c\/td\u003e\n\u003ctd\u003eStop\/Start Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA13, A14\u003c\/td\u003e\n\u003ctd\u003eWatchdog Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA15, A16\u003c\/td\u003e\n\u003ctd\u003eProgrammable Output Relay #1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA17, A18\u003c\/td\u003e\n\u003ctd\u003eProgrammable Output Relay #2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA19, A20\u003c\/td\u003e\n\u003ctd\u003eProgrammable Output Relay #3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA21, A22\u003c\/td\u003e\n\u003ctd\u003eStart Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA23, A24\u003c\/td\u003e\n\u003ctd\u003eStop Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA25, A26\u003c\/td\u003e\n\u003ctd\u003eAVR Mode Select Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA27, A28\u003c\/td\u003e\n\u003ctd\u003eFCR Mode Select Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA29, A30\u003c\/td\u003e\n\u003ctd\u003eRaise Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA31, A32\u003c\/td\u003e\n\u003ctd\u003eLower Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA33, A34\u003c\/td\u003e\n\u003ctd\u003ePre-position Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA35, A36\u003c\/td\u003e\n\u003ctd\u003eUnit\/Parallel Operation Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA37, A38\u003c\/td\u003e\n\u003ctd\u003eVar\/PF Control Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA39, A40\u003c\/td\u003e\n\u003ctd\u003eSecondary Unit Enable Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA41, A42\u003c\/td\u003e\n\u003ctd\u003eAlarm Reset Contact Input and Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA43, A44, A45\u003c\/td\u003e\n\u003ctd\u003eRS-485 Communication Output Port COM2 (A, B, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM0 (Front Panel)\u003c\/td\u003e\n\u003ctd\u003eRS-232 9-pin Sub-D Serial Port for local PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 (Side Panel)\u003c\/td\u003e\n\u003ctd\u003eRS-232 9-pin Sub-D Serial Port for dual unit autotracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect terminal C1 (GND) securely to the system chassis ground to ensure proper grounding and noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Isolation:\u003c\/strong\u003e If dual control power sources are utilized, install an AC Control Power Isolation Transformer (Basler P\/N BE31449-001) on the AC power input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Mitigation:\u003c\/strong\u003e When powering from a source already at rated voltage levels, install an Inrush Current Reduction Module (ICRM-15) to limit startup inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Unit Configurations:\u003c\/strong\u003e For redundant DECS-200 arrangements, connect units using interconnection cable P\/N 9310300032 and install a DECS Freewheeling Diode Module P\/N 9293600101.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e Maintain RS-485 network cables within a maximum distance of 4,000 feet using recommended shielded twisted-pair cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Sensing:\u003c\/strong\u003e Ensure potential transformers are installed if the line voltage exceeding 600 Vac is connected to the sensing terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized per Standard 508 (File E97035)\u003c\/li\u003e\n\u003cli\u003eCSA Certified per Standard CAN\/CSA-C22.2 No. 14 (File LR23131)\u003c\/li\u003e\n\u003cli\u003eCE Compliant (EMC and LVD directives)\u003c\/li\u003e\n\u003cli\u003eDNV Certified per Standard 2.4\u003c\/li\u003e\n\u003cli\u003eGOST-R Certified\u003c\/li\u003e\n\u003cli\u003eByelorussian Certified\u003c\/li\u003e\n\u003cli\u003eIEEE C37.90.1-1989 (Surge Withstand Capability and Fast Transient)\u003c\/li\u003e\n\u003cli\u003eIEEE 421.3 (High Pot testing)\u003c\/li\u003e\n\u003cli\u003eISO 9001:2000 Registered\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Basler Electric","offers":[{"title":"Default Title","offer_id":53644055511403,"sku":"DECS-200-1L","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DECS-200-1L_1.jpg?v=1785590957"}],"url":"https:\/\/www.plcprotech.com\/uz\/collections\/basler-electric.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}