{"title":"EPRO Eddy Tok Sensorlari (Problari)","description":"\u003cp\u003eEPRO Eddy Current Sensorlari, xususan PR6422, PR6423 va PR6424 seriyalari, milning tebranishi va pozitsiyasini aloqa qilmasdan o‘lchash uchun sanoat standartidagi probalardir. Sensor arxitekturasi eddy tok printsipidan foydalanadi, mustahkam, keramika uchi bilan qoplangan zanglamaydigan po‘lat korpusda aniq o‘ralgan bobinani o‘z ichiga oladi. Texnik xususiyatlarga keng chiziqli o‘lchash diapazoni, metall maqsadlarga yuqori sezgirlik va yuqori bosim hamda korroziy muhitlarga ajoyib chidamlilik kiradi. Funksional jihatdan, ushbu probalar radial mil tebranishi, eksantriklik va o‘q bo‘ylab siljishni real vaqt rejimida qayd etadi. \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/epro-mms-6000-series\"\u003eMMS 6000\u003c\/a\u003e konvertorlar bilan birgalikda ular bug‘ turbinalari va katta sanoat nasoslarining avtomatik himoya tizimi uchun aniq sensor ma’lumotlarini taqdim etadi.\u003c\/p\u003e","products":[{"product_id":"emerson-pr9268-300-000-electrodynamic-velocity-sensor","title":"Emerson PR9268\/300-000 Electrodynamic Velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR9268\/300-000\u003c\/strong\u003e absolute vibration transducer operates on the seismic low-tuned measuring principle to deliver precise absolute vibration measurements for machinery protection systems. Designed primarily for horizontal measurement applications, the electro-dynamic sensor utilizes a measuring coil suspended on membrane springs as its seismic mass. When operated above the natural resonance frequency, the seismic coil remains stationary, generating a voltage signal directly proportional to the vibration velocity through the relative movement between the resting coil and the moving transducer housing. Housed in durable materials with splash-proof protection, this device provides continuous asset monitoring and machinery protection in hostile industrial monitoring applications. It is fully compatible with professional machinery health protection systems and cards, such as the A6120 bearing vibration monitor and the A6500-xR system rack monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for reliable machinery protection systems and continuous vibration monitoring\u003c\/li\u003e\n\u003cli\u003eElectro-dynamic mechanical spring-mass sensor operating on a low-tuned seismic principle\u003c\/li\u003e\n\u003cli\u003eConfigured for horizontal measurement orientation with an operating temperature tolerance up to 100 degC\u003c\/li\u003e\n\u003cli\u003eAvailable with additional cable protection via a built-in armored cable structure\u003c\/li\u003e\n\u003cli\u003eFlexible integration options with or without an industrial Harting connector interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery protection systems\u003c\/li\u003e\n\u003cli\u003eBearing vibration monitoring structures\u003c\/li\u003e\n\u003cli\u003ePower generation plants and heavy rotating equipment protection\u003c\/li\u003e\n\u003cli\u003eHostile industrial process environments requiring continuous asset health monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow tuned measuring principle for absolute vibrations (Electro-dynamic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(± 5%) @ 80 Hz \/ 20 degC \/ 100 kOhm: 28.5 mV\/mm\/s (723.9 mV\/in\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1,500 µm (59,055 µin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Amplitude (Nominal Mounting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 µm peak-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit Stops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 µm peak-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(± 3dB) 4 to 1,000 Hz (240 to 60,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNatural Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz ± 0.75 Hz (at 20 degC and 100 kOhm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 at 110 Hz (horizontal mounting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDamping Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.56 at 20 degC (100 kOhm load), 0.42 at 100 degC (100 kOhm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity Error of Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Acceleration (Measuring)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g peak-peak continuous, 20 g peak-peak short-time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Acceleration (Transverse)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g peak-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measuring Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1875 Ohm ± 10% (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm (test voltage 500 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 90 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity against Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.2 nF (inclusive cable without corrugated hose)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Max Lifting Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 mA (maximum deviation 30 deg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 100 degC (-4 to 180 FX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +100 degC (without packing), -40 to +70 degC (with packing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100% Non-Condensing (in housing and plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAl Mg Si Pb F28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 0.5 mm2 shielded, PTFE coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm (for cable and protection hose)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 260 g (transducer only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling Precautions:\u003c\/strong\u003e Do not expose the transducer to hard mechanical shocks and do not drop it. Hard impacts can lead to critical internal damage, causing impairment or total loss of sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Surface:\u003c\/strong\u003e Mount the transducer firmly on a flat, clean surface using three through-bores for M6 screws or three blind hole threads for M4 screws (maximum thread depth 10 mm). Firmly tighten the mounting components to ensure accurate vibration transmission and measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Angle Constraints:\u003c\/strong\u003e The transducer is optimized for a horizontal nominal measuring direction (90 deg position). Without a lifting or sinking current, the maximum allowed angular deviation from the nominal position is ±10 deg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting\/Sinking Currents:\u003c\/strong\u003e When mounted with an angular deviation between ±60 deg and ±80 deg, a lifting current must be enabled via the system configuration software (maximum 1.8 mA at 60 deg deviation) to position the seismic mass accurately into the center of its working range. If deviation spans ±100 deg to ±120 deg, a corresponding sinking current must be utilized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Install the sensor connection cable without any structural torsion or elongation. Protect the cable from external environmental hazards. If using a model with a stainless steel armored protection hose, secure the hose with a clamp located as close to the transducer body as possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e The metal protection hose on armored cable versions is fully insulated from the cable shield and the transducer housing. Ensure the system installation conforms to standard EMC regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e II 1G Ex ia IIC T6... T4 Ga (Certificate Number: BVS 22 ATEX E 007 X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx Certification:\u003c\/strong\u003e Ex ia IIC T6... T4 Ga (Certificate Number: IECEx BVS 22.0009X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA Certification:\u003c\/strong\u003e Designated explosive atmosphere protection regulations compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European Electromagnetic Compatibility (2014\/30\/EU), ATEX Directive (2014\/34\/EU), and RoHS Directive (2011\/65\/EU) standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695172809067,"sku":"PR9268\/300-000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr9268-300-000-epro-eddy-current-sensor-qpspeijg1rd_3cf9d47e-52a0-4ade-879d-6295abb285ca.jpg?v=1766114105"},{"product_id":"emerson-pr9376-010-011-hall-effect-speed-proximity-sensor","title":"Emerson PR9376\/010-011 Hall Effect Speed\/Proximity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR9376\/010-011\u003c\/strong\u003e is a heavy-duty, non-contact Hall effect sensor specifically engineered for high-precision speed or proximity measurements on critical industrial turbomachinery. Operating as part of machine monitoring infrastructures, the \u003cstrong\u003ePR9376\/010-011\u003c\/strong\u003e tracks rotation dynamics by generating 1 AC cycle per revolution or gear tooth. This configuration comes equipped with an integrated 5-meter armored cable terminating in an open cable end, delivering robust mechanical protection in harsh operating environments. It is widely deployed to monitor the rotational velocities of steam, gas, and hydro turbines, as well as high-capacity compressors, pumps, and process fans.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact Hall effect sensing principle prevents mechanical wear and extends operational life.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty armored cable construction provides enhanced physical shielding against environmental stress.\u003c\/li\u003e\n\u003cli\u003eGenerates a precise digital output of 1 AC cycle per revolution or gear tooth for exact speed tracking.\u003c\/li\u003e\n\u003cli\u003eHigh-frequency response handling up to 12 kHz to support high-speed turbomachinery applications.\u003c\/li\u003e\n\u003cli\u003eIP67-rated environmental sealing ensures protection against dust and moisture ingress.\u003c\/li\u003e\n\u003cli\u003eOpen cable end interface provides installation flexibility for direct control cabinet termination.\u003c\/li\u003e\n\u003cli\u003eOptimized for target surfaces made of magnetic soft iron or steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbine speed monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor and turbo-charger rotation tracking\u003c\/li\u003e\n\u003cli\u003eHigh-capacity process pump speed verification\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fan and blower monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel No.\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArmored Cable Options\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePR9376\u003c\/td\u003e\n\u003ctd\u003e\/01 With Armored Cable\u003c\/td\u003e\n\u003ctd\u003e0-01 5m Cable Length\u003c\/td\u003e\n\u003ctd\u003ePR9376\/010-011 (PR9376 sensor with 5 meter armored cable, Open Cable End)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 AC cycle per revolution \/ gear tooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise \/ Fall Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 microsecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage (12 VDC at 100 kOhm load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh \u0026gt; 10 V \/ Low \u0026lt; 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 mm (Module 1)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e1.5 mm (Module \u0026gt;= 2)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kHz (720,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Mark Limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpur Wheel, Involute Gearing Module 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Target Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eST37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Surface Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic soft iron or steel (non-stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Celsius (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 100 Celsius (-13 to 212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 Celsius (-40 to 212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSealing Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC @ max. 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 400 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Body Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (Sensor Only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 grams (7.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Barrel Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Barrel Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Alignment:\u003c\/strong\u003e Ensure the sensor is positioned over a matching spur wheel or involute gearing made of magnetic soft iron or steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Gap Adjustment:\u003c\/strong\u003e Maintain an exact air gap of 1 mm for Module 1 targets, or 1.5 mm for targets with a Module \u0026gt;= 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Matching:\u003c\/strong\u003e Position the sensor body according to the structural orientation mark displayed on the housing for proper signal translation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the 5-meter armored cable away from high-voltage lines or electromagnetic interference sources to preserve signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Connect the open cable ends securely to the monitoring system interface matching the required 10 to 30 VDC supply profile.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Directive 2014\/30\/EU (EN 60947-5-2)\u003c\/li\u003e\n\u003cli\u003eCE Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eCE Directive 2011\/65\/EU (EN 63000)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695178084715,"sku":"PR9376\/010-011","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr9376-010-011-proximity-sensor-4z253ibywdl_69d82d8c-373b-485d-852a-c27359d57f90.jpg?v=1766114722"},{"product_id":"emerson-pr6423-010-010-con021-eddy-current-sensor-system","title":"Emerson PR6423\/010-010 CON021 Eddy Current Sensor System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR6423\/010-010\u003c\/strong\u003e with \u003cstrong\u003eCON021\u003c\/strong\u003e is a non-contact sensor and signal converter system engineered for critical turbomachinery applications, including steam, gas, and hydro turbines, compressors, gearboxes, pumps, and fans. The \u003cstrong\u003ePR6423\u003c\/strong\u003e eddy current sensor detects radial and axial shaft dynamic displacement, position, eccentricity, and speed. The \u003cstrong\u003eCON021\u003c\/strong\u003e sensor signal converter processes these proximity measurements into stable output signals suitable for monitoring industrial machinery health.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement principle for precise displacement tracking\u003c\/li\u003e\n\u003cli\u003eHigh-frequency response suitable for dynamic machine diagnostics\u003c\/li\u003e\n\u003cli\u003eArmored cable protection for enhanced mechanical durability in industrial environments\u003c\/li\u003e\n\u003cli\u003eFlexible mounting options with included installation screws\u003c\/li\u003e\n\u003cli\u003eTransducer connection utilizing a self-locking plug interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft dynamic displacement monitoring\u003c\/li\u003e\n\u003cli\u003eShaft position and eccentricity measurement\u003c\/li\u003e\n\u003cli\u003eSpeed monitoring and key pulse detection\u003c\/li\u003e\n\u003cli\u003eTurbomachinery protection systems (turbines, compressors, fans, pumps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel No. \/ Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6423\/01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored Cable: Yes, Case Threads: M10x1, Tip Diameter: 8mm, Case Thread X: 0 (25mm), Adapter Plug X: 0 (With), Cable Length X: 1 (5.0m), Cable End X: 0 (Lemo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Signal Converter, Sensor Type: PR6423, Measuring Range: 2.0mm (Standard Range), Linearity Error: \u0026lt;= 1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eCON021 Signal Converter Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 degC (-22 to 212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60 Hz @ 25 degC (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-24V config)\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output Range: -4V to -20V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-2V config)\u003c\/td\u003e\n\u003ctd\u003e-21V to -32V (Output Range: -2V to -18V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~120 grams (4.24 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003e4 Screws M5x20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePR6423 Eddy Current Sensor Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Threads\u003c\/td\u003e\n\u003ctd\u003eM10x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmored Cable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Air Gap\u003c\/td\u003e\n\u003ctd\u003e0.5 mm (20 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003eISO: 8 V\/mm (203.2 mV\/mil) +\/-5% @ 0 to 45 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.025 mm (+\/-1 mil) @ 0 to 45 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm (0.79 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003e42CrMo4 (AISI\/SAE 4140) Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor \u0026amp; 1m Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 degC (-31 to 356 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable \u0026amp; Connector Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 to +150 degC (-31 to 302 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eSensor Tip: PEEK, Case: Stainless Steel, Cable: PTFE, Connector: Brass (nickel-plated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Sensor with 1m Cable)\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 grams (3.53 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003eSelf-Locking Lemo-Plug Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply \/ Output Terminals\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Type (max. 1.5mm2 wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the minimum bending radius for the standard cable is at least 25 mm, and at least 35 mm for the armored cable.\u003c\/li\u003e\n\u003cli\u003eMaintain proper probe gap alignment using the target initial air gap specification of 0.5 mm for standard measurement ranges.\u003c\/li\u003e\n\u003cli\u003eMount the signal converter within an environment matching its IP20 rating, securing it firmly with the provided M5x20 screws.\u003c\/li\u003e\n\u003cli\u003eUse a safety barrier or current limiting device when deploying the system into hazardous environments requiring intrinsic safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU, DIN EN 50581\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb @ -20 degC \u0026lt;= Ta \u0026lt;= 80 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb @ -20 degC \u0026lt;= Ta \u0026lt;= 80 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I Division 1, Groups A, B, C, D, T4 (-25 degC \u0026lt;= Ta \u0026lt;= 80 degC); Class I Division 2, Groups A, B, C, D Ex nA II T3..T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e ANSI\/UL 913-2004, ANSI\/UL 1604-1995, UL 60079-15 2002, UL 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695185195371,"sku":"R6423\/010-010 CON021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-r6423-010-010-con021-eddy-current-sensor-2oasmbdbsgl_33b64fe2-06cb-4a9d-b67d-83b31db04323.jpg?v=1766114430"},{"product_id":"emerson-pr9268-017-100-electrodynamic-velocity-sensor","title":"Emerson PR9268\/017-100 Electrodynamic Velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR9268\/017-100\u003c\/strong\u003e is a mechanical electrodynamic velocity sensor designed for absolute vibration measurement of critical turbomachinery applications. It provides case vibration monitoring for systems such as steam, gas, and hydro turbines, as well as compressors, pumps, and fans. Operating as a self-powered device, this \u003cstrong\u003evelocity sensor\u003c\/strong\u003e converts mechanical vibration into an electrical signal proportional to velocity, transmitting dynamic data to continuous machinery protection systems like AMS monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical velocity sensor design optimized for critical turbomachinery protection.\u003c\/li\u003e\n\u003cli\u003eSelf-powered design requiring no external excitation power for signal generation.\u003c\/li\u003e\n\u003cli\u003eRobust housing constructed from stainless steel for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eOmni-directional sensor orientation capability enabling versatile mounting configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbine case vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eTurbo-compressor vibration measurement.\u003c\/li\u003e\n\u003cli\u003eHigh-performance industrial pumps and ventilation fans.\u003c\/li\u003e\n\u003cli\u003ePower plant and petrochemical industrial rotating machinery protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOmni Directional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mV\/mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNatural Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 Hz $\\pm$ 7% @ 20 degC (68 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 @ 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 $\\mu$m peak-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Acceleration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10g (98.1 $m\/s^2$) peak-peak continuous \/ 20g (196.2 $m\/s^2$) peak-peak intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transverse Acceleration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2g (19.62 $m\/s^2$)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDamping Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.696 @ 20 degC (68 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1723 $\\Omega$ $\\pm$ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e$\\le$ 90 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.2 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +100 degC (-4 to 212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100%, Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core Material \/ Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE, 3x 0.5 $mm^2$\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDie Cast Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor is securely attached to the machine housing using the specified M10x1 threads.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to prevent mechanical stress or wear on the armored cable assembly.\u003c\/li\u003e\n\u003cli\u003eKeep the integrated shielding grounded according to standard industrial machinery protection procedures to eliminate EMI\/RFI noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU (EN 63000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA\u003c\/strong\u003e: S.I. 2016 No. 1091, S.I. 2016 No. 1107, S.I. 2012 No. 3032\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695187259755,"sku":"PR9268\/017-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr9268-017-100-epro-mechanical-velocity-sensor-gpdx5p2ptbq_d1361f41-0858-4cd6-b7e9-144c18f4f774.jpg?v=1766114502"},{"product_id":"emerson-pr6426-010-000-con021-916-160-eddy-current-sensor-system","title":"Emerson PR6426\/010-000 CON021\/916-160 Eddy Current Sensor System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR6426\/010-000\u003c\/strong\u003e non-contact sensor combined with the \u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e signal converter forms an industrial eddy current measurement system optimized for critical turbomachinery applications, including steam, gas, and hydro turbines, compressors, pumps, and fans. The \u003cstrong\u003ePR6426\u003c\/strong\u003e eddy current sensor detects radial and axial shaft displacement, position, eccentricity, and motion under harsh operating conditions. The matched \u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e converter accurately processes these proximity metrics into reliable electrical signals required by machinery protection and TSI monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement technique for precise tracking of shaft position and dynamics\u003c\/li\u003e\n\u003cli\u003eRobust engineering built to withstand demanding and tough industrial conditions\u003c\/li\u003e\n\u003cli\u003eSensor tip assembly capable of enduring high pressure up to 6,500 hpa\u003c\/li\u003e\n\u003cli\u003eStable signal translation over an extended displacement range up to 16.0mm\u003c\/li\u003e\n\u003cli\u003eUnarmored cable layout equipped with a premium self-locking plug connector interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft dynamic displacement monitoring\u003c\/li\u003e\n\u003cli\u003eTurbomachinery position, motion, and eccentricity registration\u003c\/li\u003e\n\u003cli\u003eComprehensive mechanical protection loops for high-speed gas\/steam turbines and heavy compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6426\/010-000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32mm Eddy Current Sensor, No Sleeve Thread, Unarmored Cable, Mounting Plate, Without Adaptor Plug\u003c\/td\u003e\n\u003ctd\u003e+\/-4.0 mm (Standard Range) \/ 16.0mm Extended\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1.5% max (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Signal Converter for PR6426\u003c\/td\u003e\n\u003ctd\u003e16.0mm (Extended Range)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eCON021\/916-160 Signal Converter Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 degC (-22 to 212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60 Hz @ 25 degC (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-24V config)\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output Range: -4V to -20V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-2V config)\u003c\/td\u003e\n\u003ctd\u003e-21V to -32V (Output Range: -2V to -18V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~120 grams (4.24 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003e4 Screws M5x20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePR6426 Eddy Current Sensor Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e2 V\/mm (50.8 mV\/mil) \u0026lt;= +\/-1.5% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap (Center)\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.5 mm (0.22\") Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget\/Surface Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel (42 Cr Mo 4 Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surface Speed\u003c\/td\u003e\n\u003ctd\u003e2,500 m\/s (98,425 ips)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e200 mm (7.87\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-35 to 175 degC (-31 to 347 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Excursions (\u0026lt;4 Hours)\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Resistance to Sensor Head\u003c\/td\u003e\n\u003ctd\u003e6,500 hpa (94 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g (49.05 m\/s2) @ 60Hz @ 25 degC (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Sensor \u0026amp; 1M Cable, no Armor)\u003c\/td\u003e\n\u003ctd\u003e~800 grams (28.22 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Connection\u003c\/td\u003e\n\u003ctd\u003eSelf-Locking Lemo-Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\/Output Connection\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Type (max. 1.5mm2 wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the unarmored sensor cable respects a minimum static bending radius of 25 mm during routing.\u003c\/li\u003e\n\u003cli\u003eKeep a clear exclusion zone of at least 80 mm diameter centered around the 32mm sensor head to eliminate peripheral metal interference.\u003c\/li\u003e\n\u003cli\u003eAdjust the mechanical probe position to find the nominal center air gap of approximately 5.5 mm before locking down.\u003c\/li\u003e\n\u003cli\u003eUse appropriate safety barriers and signal isolation paths when routing transducer loops through explosive or certified hazardous zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU, DIN EN 50581\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb, -20 degC \u0026lt;= Ta \u0026lt;= 80 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb, -20 degC \u0026lt;= Ta \u0026lt;= 80 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CAN\/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN\/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04 (Class I Division 1, Groups A, B, C, D, T4; Class I Division 2, Groups A, B, C, D Ex nA II T3..T4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e ANSI\/UL Standard 913-2004, ANSI\/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695406346603,"sku":"PR6426\/010-000 CON021\/916-160","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6426-010-000-con021-916-160-epro-plc-module-qduwkey3kpw.jpg?v=1766052961"},{"product_id":"emerson-pr9350-02-ams-inductive-sensor","title":"Emerson PR9350\/02 AMS Inductive Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR9350\/02\u003c\/strong\u003e is a surface contact inductive sensor designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, pumps, and fans. This heavy-duty displacement transducer measures radial and axial shaft dynamic displacement, position, and eccentricity under tough environmental conditions. Operating on a carrier frequency principle with center-tapped windings, the \u003cstrong\u003ePR9350\/02\u003c\/strong\u003e provides stable position tracking and high precision for industrial machinery protection and condition monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSurface contact inductive design optimized for shaft displacement and eccentricity tracking \u003c\/li\u003e\n\u003cli\u003eRobust construction tailored to survive demanding and tough industrial environments \u003c\/li\u003e\n\u003cli\u003eSupplied with a matching solenoid plunger featuring an integrated M3 threaded rod \u003c\/li\u003e\n\u003cli\u003eEquipped with a reliable electrical interface utilizing an ITT Cannon connector \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft dynamic displacement measurement \u003c\/li\u003e\n\u003cli\u003eTurbomachinery shaft position and eccentricity monitoring \u003c\/li\u003e\n\u003cli\u003eCritical protection loops for gas, steam, and hydro turbines \u003c\/li\u003e\n\u003cli\u003eStructural or displacement monitoring on large industrial compressors, pumps, and fans \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR9350\/02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+25 mm\u003c\/td\u003e\n\u003ctd\u003e270 mV\/V\u003c\/td\u003e\n\u003ctd\u003e3.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance \u0026amp; Dynamic Performance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e+25 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e270 mV\/V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e3.5% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 Vrms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Frequency\u003c\/td\u003e\n\u003ctd\u003e3 to 5 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e250 pF (each winding) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20 to 100 degC (-4 to 212 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical \u0026amp; Mechanical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 grams \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension A\u003c\/td\u003e\n\u003ctd\u003e108 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension B\u003c\/td\u003e\n\u003ctd\u003e127 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension C (with core slug in nominal center or zero position)\u003c\/td\u003e\n\u003ctd\u003e65.4 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension D\u003c\/td\u003e\n\u003ctd\u003e76.2 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension E\u003c\/td\u003e\n\u003ctd\u003e123.2 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension F\u003c\/td\u003e\n\u003ctd\u003e25.4 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximal Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing Holes\u003c\/td\u003e\n\u003ctd\u003eM4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlunger Thread\u003c\/td\u003e\n\u003ctd\u003eM3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCannon Connector CA06COME10SL3S44\u003c\/td\u003e\n\u003ctd\u003eElectrical interface connection mapping to internal center tapped windings \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse the integrated M4 fixing holes to securely mount the housing block to a stable reference point on the machine casing.\u003c\/li\u003e\n\u003cli\u003eEnsure proper mechanical alignment of the solenoid plunger with the M3 threaded rod during setup.\u003c\/li\u003e\n\u003cli\u003eAlign the core slug to match dimension C (65.4 mm) relative to the sensor frame to reference the true nominal center or zero position.\u003c\/li\u003e\n\u003cli\u003eVerify that the carrier frequency of the driver electronics is configured between 3 and 5 kHz to preserve sensitivity and accuracy requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695408574827,"sku":"PR9350\/02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr9350-02-cylinder-expansion-yo5pbqqdyuc.jpg?v=1766052979"},{"product_id":"emerson-pr9376-010-001-epro-hall-effect-speed-proximity-sensor","title":"Emerson PR9376\/010-001 EPRO Hall Effect Speed\/ Proximity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR9376\/010-001\u003c\/strong\u003e is a non-contact \u003cstrong\u003eHall effect sensor\u003c\/strong\u003e engineered for precise speed or proximity measurements in critical turbomachinery applications. This \u003cstrong\u003esensor\u003c\/strong\u003e is designed for use with steam, gas and hydro turbines, compressors, pumps, and fans. It provides a frequency-based output proportional to the rotation of a gear or target, ensuring reliable performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact measurement technology\u003c\/li\u003e\n\u003cli\u003e1 AC cycle per revolution\/gear tooth output\u003c\/li\u003e\n\u003cli\u003eHigh frequency operation up to 12 kHz\u003c\/li\u003e\n\u003cli\u003eIntegrated armored cable for enhanced mechanical protection\u003c\/li\u003e\n\u003cli\u003eOpen cable end configuration\u003c\/li\u003e\n\u003cli\u003eRobust sealing for harsh industrial conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine speed monitoring\u003c\/li\u003e\n\u003cli\u003eHydro turbine rotation measurement\u003c\/li\u003e\n\u003cli\u003eCompressor and pump speed sensing\u003c\/li\u003e\n\u003cli\u003eCritical turbomachinery proximity detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel No.\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArmored Cable\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePR9376\u003c\/td\u003e\n\u003ctd\u003e1 With\u003c\/td\u003e\n\u003ctd\u003e0 3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e1 AC cycle per revolution\/gear tooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise\/Fall Time\u003c\/td\u003e\n\u003ctd\u003e1 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (12 VDC at 100 kOhm load)\u003c\/td\u003e\n\u003ctd\u003eHigh \u0026gt;10 V \/ Low \u0026lt;1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap\u003c\/td\u003e\n\u003ctd\u003e1 mm (Module 1), 1.5 mm (Module \u0026gt;= 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Frequency\u003c\/td\u003e\n\u003ctd\u003e12 kHz (720,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Target\u003c\/td\u003e\n\u003ctd\u003eMaterial ST37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC @ max. 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eMax. 400 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-25 to 100 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the target surface material consists of magnetic soft iron or steel (non-stainless steel).\u003c\/li\u003e\n\u003cli\u003eAlign the \u003cstrong\u003esensor\u003c\/strong\u003e to maintain the specified air gap (1 mm for Module 1, 1.5 mm for Module \u0026gt;= 2) from the trigger mark or spur wheel.\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated armored cable to prevent mechanical damage in vibration-prone areas.\u003c\/li\u003e\n\u003cli\u003eEnsure power supply remains within the 10 to 30 VDC range to maintain output signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE (2014\/30\/EU, EN 60947-5-2)\u003c\/li\u003e\n\u003cli\u003eCE (2014\/35\/EU)\u003c\/li\u003e\n\u003cli\u003eCE (2011\/65\/EU, EN 63000)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695409066347,"sku":"PR9376\/010-001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR9376_010-001_2_1.png?v=1782629706"},{"product_id":"emerson-pr6426-000-131-con041-916-200-eddy-current-sensor-system","title":"Emerson PR6426\/000-131 CON041\/916-200 Eddy Current Sensor System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR6426\/000-131\u003c\/strong\u003e non-contact eddy current sensor operates in combination with the \u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e signal converter to form a proximity measurement system for heavy industrial turbomachinery. Engineered for deployment on steam, gas, and hydro turbines, as well as compressors, pumps, and fans, this assembly measures radial and axial shaft displacement, position, eccentricity, and motion. The \u003cstrong\u003ePR6426\/000-131\u003c\/strong\u003e sensor monitors physical shaft proximity without direct contact, while the \u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e converter processes these variables into normalized electrical outputs suitable for continuous machinery protection networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement mechanism for detailed shaft dynamics and displacement tracking \u003c\/li\u003e\n\u003cli\u003eHigh-pressure durability with a sensor head rated to withstand up to 6,500 hpa \u003c\/li\u003e\n\u003cli\u003eExtended measurement range up to 20.0mm when paired with the designated configuration converter \u003c\/li\u003e\n\u003cli\u003eRugged physical construction featuring a stainless steel sleeve and high-temperature PTFE cable insulation \u003c\/li\u003e\n\u003cli\u003eFast loop processing execution defined by a signal rise time under 15 microseconds \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft dynamic displacement logging \u003c\/li\u003e\n\u003cli\u003eIndustrial turbomachinery position, motion, and eccentricity monitoring \u003c\/li\u003e\n\u003cli\u003eMachinery protection monitoring across turbines, compressors, and large industrial fans \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON041\/916-200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePR6426\u003c\/td\u003e\n\u003ctd\u003e20.0mm (Extended Range)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.5% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eDynamic \u0026amp; Performance Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003e2 V\/mm (50.8 mV\/mil) \u0026lt;= +\/-1.5% max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap (Center)\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.5 mm (0.22\") Nominal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surface Speed\u003c\/td\u003e\n\u003ctd\u003e2,500 m\/s (98,425 ips) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget \/ Surface Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel (42 Cr Mo 4 Standard) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 200 mm (7.87\") \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-24V Configuration)\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output Range: -4V to -20V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-2V Configuration)\u003c\/td\u003e\n\u003ctd\u003e-21V to -32V (Output Range: -2V to -18V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 degC (-22 to 212 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-35 to 175 degC (-31 to 347 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Temperature Excursions (\u0026lt;4 Hours)\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Shock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Shock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g (49.05 m\/s2) @ 60Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Protection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Housing Material\u003c\/td\u003e\n\u003ctd\u003ePA 6.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Weight\u003c\/td\u003e\n\u003ctd\u003e~60 grams (2.12 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sleeve Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Cable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Weight (with 1M Cable, No Armor)\u003c\/td\u003e\n\u003ctd\u003e~800 grams (28.22 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input Connection\u003c\/td\u003e\n\u003ctd\u003eSelf-Locking Lemo-Plug \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply \/ Output Connection\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Type (Max. 1.5mm2, wire-end sleeves) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the signal converter module on a standard DIN rail carrier inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain a clear zone of at least 80 mm diameter free of ferrous material around the 32mm sensor head to avoid field distortion.\u003c\/li\u003e\n\u003cli\u003eObserve a minimum cable bending radius of 35 mm for armored cable paths, or 25 mm for non-armored variants.\u003c\/li\u003e\n\u003cli\u003eCalibrate the initial sensor position to a nominal center air gap of approximately 5.5 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU (DIN EN 50581) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e EN 60079-0, EN 60079-11; II 2 G Ex ia IIC T4 Gb (-20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e IEC 60079-0, IEC 60079-11, IEC 60079-26; Ex ia IIC T4 Gb (-20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CAN\/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN\/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04; ANSI\/UL Standard 913-2004, ANSI\/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Entry:\u003c\/strong\u003e Intrinsic Safety (Ex ia IIC T4 Gb \/ Class I Division 1 Groups A, B, C, D T4); Non-sparking (Class I Division 2 Groups A, B, C, D \/ Ex nA II T3..T4 \/ AEx nA II T3..T4) \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695410770283,"sku":"PR6426\/000-131 CON041\/916-200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6426-000-131-con041-916-200-eddy-current-sensor-s3qmn1mgkux.jpg?v=1766052953"},{"product_id":"emerson-pr6426-010-030-con021-916-160-eddy-current-sensor-system","title":"Emerson PR6426\/010-030 CON021\/916-160 Eddy Current Sensor System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR6426\/010-030\u003c\/strong\u003e non-contact sensor combined with the \u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e signal converter forms an advanced eddy current measurement system designed for critical turbomachinery applications, such as steam, gas, and hydro turbines, compressors, pumps, and fans. The \u003cstrong\u003ePR6426\u003c\/strong\u003e eddy current sensor specializes in measuring radial and axial shaft displacement, position, eccentricity, and motion under demanding industrial environments. The processed information is transferred via the \u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e converter to provide a stable electrical output for machine protection and TSI monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement principle for precise tracking of industrial machine conditions \u003c\/li\u003e\n\u003cli\u003eHigh-temperature durability with sensor head operation up to 175 degC \u003c\/li\u003e\n\u003cli\u003eBuilt-in protection resisting pressures up to 6,500 hpa at the sensor head \u003c\/li\u003e\n\u003cli\u003eExtended measurement range capacity up to 16.0mm optimized for large displacement detection \u003c\/li\u003e\n\u003cli\u003eRugged design with a standard stainless steel sleeve and high-end PTFE insulation \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial and axial shaft displacement monitoring \u003c\/li\u003e\n\u003cli\u003eTurbomachinery position, motion, and eccentricity verification \u003c\/li\u003e\n\u003cli\u003eCritical machinery protection systems for gas\/steam turbines and heavy compressors \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6426\/010-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32mm Eddy Current Sensor\u003c\/td\u003e\n\u003ctd\u003e+\/-4.0 mm (Standard Range) \/ 16.0mm Extended\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1.5% max (Sensor) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePR6426\u003c\/td\u003e\n\u003ctd\u003e16.0mm (Extended Range)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.0% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eCON021\/916-160 Signal Converter Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 degC (-22 to 212 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g @ 60 Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-24V config)\u003c\/td\u003e\n\u003ctd\u003e-23V to -32V (Output Range: -4V to -20V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (-2V config)\u003c\/td\u003e\n\u003ctd\u003e-21V to -32V (Output Range: -2V to -18V) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~120 grams (4.24 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003e4 Screws M5x20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePR6426 Eddy Current Sensor Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e32mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e2 V\/mm (50.8 mV\/mil) \u0026lt;= +\/-1.5% max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap (Center)\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.5 mm (0.22\") Nominal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget\/Surface Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel (42 Cr Mo 4 Standard) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surface Speed\u003c\/td\u003e\n\u003ctd\u003e2,500 m\/s (98,425 ips) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e200 mm (7.87\") \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-35 to 175 degC (-31 to 347 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Excursions (\u0026lt;4 Hours)\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Temperature\u003c\/td\u003e\n\u003ctd\u003e200 degC (392 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Resistance to Sensor Head\u003c\/td\u003e\n\u003ctd\u003e6,500 hpa (94 psi) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003e5g (49.05 m\/s2) @ 60Hz @ 25 degC (77 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Sensor \u0026amp; 1M Cable, no Armor)\u003c\/td\u003e\n\u003ctd\u003e~800 grams (28.22 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Connection\u003c\/td\u003e\n\u003ctd\u003eSelf-Locking Lemo-Plug \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\/Output Connection\u003c\/td\u003e\n\u003ctd\u003eScrew Terminal Type (max. 1.5mm2 wire) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObserve the minimum cable bending radius rules: 35 mm for armored configurations and 25 mm for non-armored cables.\u003c\/li\u003e\n\u003cli\u003eKeep a clear zone of at least 80 mm diameter around the sensor head free of unintended ferrous materials.\u003c\/li\u003e\n\u003cli\u003eSet the center air gap to approximately 5.5 mm nominal during initial probe gap adjustment.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and use external current limiting, such as safety barriers, when installing in certified hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU, DIN EN 50581 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb, -20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC-Ex:\u003c\/strong\u003e IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb, -20 degC \u0026lt;= Ta \u0026lt;= 80 degC) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CAN\/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN\/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04 (Class I Division 1, Groups A, B, C, D, T4; Class I Division 2, Groups A, B, C, D Ex nA II T3..T4) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e ANSI\/UL Standard 913-2004, ANSI\/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695411687787,"sku":"PR6426\/010-030 CON021\/916-160","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6426-010-030-con021-916-160-eddy-current-sensor-wf5rcgbvout.jpg?v=1766052968"},{"product_id":"emerson-pr6423-xxx-x4x-con021-epro-eddy-current-proximity-transducer-system","title":"Emerson PR6423\/XXX-X4X + CON021 EPRO Eddy Current Proximity Transducer System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Emerson\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEPRO\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries PR6423 and CON021 constitute a complete Eddy Current Proximity Transducer System, engineered for high-precision, non-contacting displacement and vibration measurements. This system is a core component of the CSI 6500 and MMS 6000 Machinery Health Monitors, specifically designed for the protection of critical rotating machinery such as steam\/gas turbines, centrifugal compressors, and boiler feed pumps.\u003c\/p\u003e\n\u003cp\u003eThe system operates by generating a high-frequency electromagnetic field at the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423 Eddy Current Displacement Transducer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etip. As the distance between the sensor and the metallic shaft changes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021 Eddy Current Signal Converter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edetects variations in the eddy current losses and translates them into a highly linear negative voltage signal. Known for its stability in high-temperature and high-pressure environments, the EPRO PR6423 system is the industry standard for measuring radial shaft vibration, axial thrust position, and shaft eccentricity according to API 670 standards.\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture\u003c\/h3\u003e\n\u003cp\u003eThe measurement string is a factory-calibrated unit consisting of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePR6423 (Standard 2.0 mm range).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConverter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCON021 (Standard range driver).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterconnect:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated or extension cable matched to an 8-meter (\u003cstrong\u003eX4X\u003c\/strong\u003e) electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel (System)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePR6423\/XXX-X4X + CON021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (EPRO Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSI 6500 \/ MMS 6000 Machinery Health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (0.08 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 1.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20,000 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Meters (Fixed Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-23 VDC to -32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-4 V to -20 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensor: -35 to 180°C \/ Converter: -30 to 100°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Pressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 hPa (145 psi) at sensor head\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eTo ensure system compatibility and calibration accuracy, the following part number structures are utilized for the EPRO series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Converter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Signal Converter (Standard Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePR6423\/XXX-X4X\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0mm Sensor, 8m Total Length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX4X\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix denoting 8m system calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Cable Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the EPRO proximity system, the cable is an active part of the tuned oscillator circuit. The CON021 is specifically calibrated for the inductance of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-meter (X4X)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estring. Shortening the cable will increase sensitivity and decrease the linear range, while lengthening it will decrease sensitivity. Field repairs involving cable splicing are not permitted as they compromise the EMI shielding and system impedance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Runout and Target Material:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e42CrMo4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esteel. If the target area on the shaft has residual magnetism (magnetic runout) or is made of a different alloy, the CON021 output will include false vibration signals. Ensure the shaft is degaussed and the target surface is concentric to the bearing journals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PR6423 should be mounted in a rigid bracket to prevent \"bracket resonance\" from being misinterpreted as shaft vibration. Use the CON021 output voltage to set the air gap; a reading of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-12.0 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the sensor is at the electrical center of its 2.0 mm linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the PR6423 sensor is hermetically sealed, the Lemo connection between the sensor and extension cable is a common failure point if exposed to oil or moisture. It is mandatory to use the supplied PTFE sealing or an IP65-rated junction box for this connection.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting \u0026amp; FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace a PR6423 sensor without replacing the CON021?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new sensor has the same total cable length code (e.g., X4X for 8m) as the original, as the CON021 is tuned to the total length, not the individual sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does a constant -0.5V to -1.0V output from the CON021 indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This usually indicates a \"Short Circuit\" or \"Bottom Out\" condition where the sensor is physically touching the shaft or the cable is crushed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does temperature affect the EPRO system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The PR6423 features temperature compensation. However, extreme shifts can cause a zero-point drift of approximately 200 mV \/ 100° K. This is usually negligible for vibration but should be considered for precision thrust position monitoring.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695422337387,"sku":"PR6423\/XXX\/X4X CON021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6423-xxx-x4x-con021-eddy-current-signal-x3yaold02vt.jpg?v=1766052881"},{"product_id":"emerson-epro-pr6424-004-010-con021-eddy-current-transducer","title":"Emerson EPRO PR6424\/004-010 CON021 Eddy Current Transducer","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePR6424\/004-010 (CON021)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision non-contact Eddy Current Transducer,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ea core component of the Emerson (formerly Epro)\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePhilips\/Bently Nevada legacy\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration monitoring series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically engineered for demanding turbomachinery applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis 10 mm displacement sensor is designed to measure shaft vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaxial thrust,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand eccentricities in critical assets like steam turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecentrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand large industrial pumps.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing eddy current induction principles,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePR6424\/004-010\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edelivers a high-resolution signal proportional to the gap between the sensor tip and the target material,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling early detection of mechanical wear and preventing catastrophic machinery failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eCON021\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evariant is optimized for durability and specific cable management:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSensor Tip:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10 mm diameter probe,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edesigned for long-range displacement measurements and high sensitivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Architecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 m integral cable (often referred to by the \/010 suffix) terminating in a specialized connector for extension to the driver\/converter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEddy Current Principle:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperates by generating a high-frequency electromagnetic field; as a metallic target approaches,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeddy currents are induced,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecausing a measurable change in the oscillator amplitude.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor head is hermetically sealed and resistant to oils,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemicals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand high-pressure environments (up to 20 bar at the tip).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with the MMS 6000 and MMS 3000 machinery monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePR6424\/004-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson (Epro)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm to 4.0 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegral Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 Celsius (Sensor Tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000 kPa (20 bar) at the tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel with PEEK tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the significance of the \"CON021\" designation?\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe CON series refers to the specific configuration of the cable length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econnector type,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand armor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor the PR6424,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCON021 typically denotes the standard industrial configuration with a 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 m cable,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for use with the CON0x1 series of signal converters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this transducer require a driver (oscillator)?\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePR6424\/004-010\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a passive sensor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt must be connected to a matching converter (e.\u003c\/span\u003e\u003cspan class=\"\"\u003eg.,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCON011 or CON021 drivers) to translate the physical gap change into a standard 4-20 mA or voltage signal (typically -2V to -18V DC).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this sensor be used with any target material?\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard calibration is for 42CrMo4 steel (AISI 4140).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf the target shaft is made of a different alloy (e.\u003c\/span\u003e\u003cspan class=\"\"\u003eg.,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estainless steel or aluminum),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe sensitivity (mV\/mm) will change significantly,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enecessitating a custom calibration at the converter level.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe \"Static Gap\" must be set using a voltmeter connected to the driver output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor a standard 10 mm probe,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe sensor is usually positioned so the output is approximately -10.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 VDC (the center of the linear range).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCross-Talk Prevention:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf mounting multiple PR6424 probes in close proximity (e.\u003c\/span\u003e\u003cspan class=\"\"\u003eg.,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eX and Y vibration probes),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensure a minimum lateral distance of at least 40 mm between probe centers to prevent electromagnetic interference (cross-talk).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCable Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe integral cable is sensitive to sharp bends.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum bend radius of 25 mm.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn oily or abrasive environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensure the cable is routed through flexible stainless steel conduit or \"armor\" to prevent signal degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface Finish:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor accurate vibration measurement, the area of the shaft under the sensor tip (the \"track\") must be free of scratches, rust, and mechanical runout. A surface finish of 0.8 µm Ra or better is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695422828907,"sku":"PR6424\/004-010 CON021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR6424_004-010CON021_1.png?v=1776928759"},{"product_id":"pr6424-104-141-con041-emerson-epro-16mm-eddy-current-measurement-system","title":"PR6424\/104-141 CON041 Emerson Epro 16mm Eddy Current Measurement System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6424\/104-141 CON041 (PR6424\/104-141 CON041)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an integrated high-precision eddy current measurement set designed for the most demanding turbomachinery protection environments. This system combines a 16 mm diameter sensor with a dedicated CON041 signal converter to monitor shaft vibration, axial position, and eccentricity in heavy-duty rotating assets such as steam turbines, high-pressure compressors, and large hydro-generators. By utilizing a larger sensor head, the system achieves a significant measurement range and enhanced stability compared to standard probes. This assembly is a critical component of Turbine Supervisory Instrumentation (TSI), providing the real-time data necessary for the Emerson AMS 6500 to prevent catastrophic mechanical failure and ensure maximum plant availability in industries like power generation and oil refining.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThis system operates on the inductive eddy current principle, where the CON041 driver provides high-frequency excitation to the 16 mm sensor head.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16 mm Sensor Architecture (PR6424):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"104-141\" configuration specifies a ruggedized sensor with a 16 mm tip, optimized for large shaft diameters (greater than or equal to 80 mm). The larger coil diameter provides a deeper magnetic field penetration, which is essential for measuring high-amplitude vibrations or large axial displacements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Converter Logic (CON041):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe converter acts as a high-speed processor that demodulates the impedance changes in the sensor into a standardized analog voltage. It features a fast rise time of less than 15 microseconds, ensuring even high-frequency transients are captured accurately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor head is hermetically sealed and pressure-resistant up to 10,000 hPa (145 psi), allowing for installation in pressurized oil-lubricated bearing housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmored Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"1\" in the configuration typically denotes a reinforced armored cable, providing mechanical protection against sharp edges and physical stress in industrial conduit systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePR6424\/104-141 CON041\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (Epro)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~1.3 kg (Combined Set)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSleeve Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-16 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 mm (Standard Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 V\/mm (101.6 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than or equal to 1.5 percent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (Tip)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 150 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20,000 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-21 VDC to -32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why use a 16 mm sensor like the PR6424 instead of a standard 8 mm sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The 16 mm tip provides a much larger linear measuring range (up to 8.0 mm). This is vital for large machines where thermal expansion or axial \"float\" exceeds the 2.0 mm limit of smaller sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the significance of the target material for this system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Eddy current sensors are sensitive to the conductivity and permeability of the target. This system is factory-calibrated for Ferromagnetic Steel (42 Cr Mo4). Using other materials will require a sensitivity adjustment in the monitoring system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the CON041 be mounted directly on the machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No, the CON041 is an IP20 rated device and must be installed in a protected junction box or control cabinet using standard DIN rail mounting to prevent damage from moisture and dust.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor the 8.0 mm measuring range, the nominal air gap center is approximately 2.7 mm. During installation, adjust the sensor position until the CON041 output voltage reaches the midpoint of the linear curve (typically -10 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface Finish:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent \"electrical runout,\" the shaft surface must be free of scratches, tool marks, and magnetic spots. A surface finish of 1.0 micrometer Ra or better is recommended for vibration measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the armored cable is securely clamped but not crushed. Maintain a minimum bend radius to prevent internal damage to the coaxial core, which is critical for maintaining the tuned resonance frequency of the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe PR6424\/104-141 CON041 set offers an industry-leading long-term drift of less than 0.3%, ensuring that the safety protection system remains accurate between major plant turnarounds. The 16 mm head design provides a superior signal-to-noise ratio, allowing for the detection of subtle changes in machine health even in electrically noisy environments near high-power generators. Furthermore, its downward compatibility with older Philips epro systems simplifies the modernization of legacy TSI hardware without requiring structural modifications to the machine casing.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695423189355,"sku":"PR6424\/104-141 CON041","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR6424_104-141CON041_2.png?v=1775914067"},{"product_id":"pr6426-010-000-con021-emerson-epro-eddy-current-measurement-system","title":"PR6426\/010-000 CON021 Emerson Epro Eddy Current Measurement System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\/010-000 CON021 (PR6426\/010-000 CON021)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized non-contact eddy current measurement system designed for the most demanding turbomachinery protection applications. This high-reliability set combines a 12 mm displacement sensor with a Lemo-plug compatible signal converter to monitor shaft vibration, axial position, and eccentricity in power plant turbines, high-speed compressors, and industrial fans. By providing continuous, micron-level data to systems like the AMS 6500, this system acts as a critical early-warning mechanism. Its ability to operate in extreme environments—including high-pressure oil and temperatures up to 175 deg C—ensures operational safety and prevents catastrophic mechanical failures that lead to expensive unplanned outages.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes a matched-impedance inductive circuit to translate physical displacement into a standardized analog voltage.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Head (PR6426):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 12 mm diameter ceramic tip. The larger tip diameter relative to standard 8 mm sensors allows for a significantly wider magnetic field and a more robust linear measuring range, making it ideal for large-scale industrial shafts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Converter (CON021):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActs as the high-frequency driver and signal conditioner. It is specifically designed for the PR642x series and utilizes a self-locking Lemo-plug for the transducer connection, ensuring a vibration-proof electrical link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinearity \u0026amp; Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe system is engineered to maintain a linearity error of less than or equal to 1.5 percent over its standard measuring range, providing the deterministic performance required for safety-instrumented systems (SIS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a frequency range of 0 to 20,000 Hz and a rise time of less than 15 microseconds, the CON021 captures high-frequency vibration transients that are often missed by lower-specification converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePR6426\/010-000 CON021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (Epro)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~120 grams (Converter) \/ ~800 grams (Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 mm (Standard) \/ up to 20.0 mm (Extended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (Tip)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +175 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (CON)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20,000 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-23 VDC to -32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-2 VDC to -18 VDC or -4 VDC to -20 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of the Lemo-plug connection on the CON021?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The Lemo-plug is a self-locking connector that prevents accidental disconnection due to high machine vibration. It also ensures a consistent impedance at the connection point, which is vital for the accuracy of eddy current measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the PR6426\/010-000 be used in submerged oil applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the sensor tip is hermetically sealed and pressure-resistant up to 10 bar at the sensing face, making it suitable for installation inside gearboxes or hydrodynamic bearings where oil mist or submersion is common.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I choose between the -2 V to -18 V and -4 V to -20 V output ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: This is determined by your host system's input card requirements. The CON021 supports both, but you must ensure the supply voltage is matched (e.g., -21 V to -32 V for the -2 V to -18 V output range).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Setup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor precise measurement, the sensor must be gapped to the \"Zero\" point of the linear curve, typically resulting in a -10 VDC output at the CON021. Use a micrometer fixture during installation to verify the gap before tightening the mounting nuts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor cable is an integral part of the measurement circuit. Do not cut, splice, or shorten the cable, as this will alter the system inductance and invalidate the factory calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Side-Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure a minimum clearance of 1.5 times the tip diameter (approx. 18 mm) from any metallic side-walls to prevent \"side-loading\" effects that distort the magnetic flux and lead to false readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe PR6426\/010-000 CON021 set stands out for its superior thermal stability and \"fit-and-forget\" reliability. The 12 mm tip diameter allows for a larger physical clearance between the sensor and the target, reducing the risk of mechanical contact during extreme shaft surge. Furthermore, the CON021's aluminum housing (LMgSi 0.5 F22) provides excellent RFI\/EMI shielding, ensuring that the critical vibration signals remain pure even when the system is mounted in close proximity to high-voltage generators or frequency drives.\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695424303467,"sku":"PR6426\/010-000 CON021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR6426_010-000CON021.png?v=1775912802"},{"product_id":"pr6426-000-131-con041-emerson-epro-eddy-current-measurement-system","title":"PR6426\/000-131 CON041 Emerson Epro Eddy Current Measurement System","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\/000-131 CON041 (PR6426\/000-131 CON041)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an integrated eddy current measurement system designed for non-contact displacement and vibration monitoring in high-criticality turbomachinery. This industrial-grade solution combines a high-sensitivity 12 mm sensor with a dedicated signal converter to deliver precise measurements in power plants, oil refineries, and large-scale mining operations.\u003c\/p\u003e\n\u003cp\u003eBy converting physical distance changes into proportional voltage signals, the system provides real-time data to Turbine Supervisory Instrumentation (TSI) for detecting shaft vibration, axial position, and eccentricity. The ruggedized design ensures reliable operation in harsh environments with oil mist and extreme temperatures, significantly reducing the risk of catastrophic mechanical failure and unplanned plant downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration (Deep Dive)\u003c\/h2\u003e\n\u003cp\u003eThe system operates on the inductive eddy current principle, using a tuned resonance circuit between the sensor and the converter.\u003c\/p\u003e\n\u003ch3\u003eSensor Head Architecture\u003c\/h3\u003e\n\u003cp\u003eThe PR6426 sensor features a 12 mm diameter tip, providing a wider magnetic field and a longer linear measuring range compared to standard 8 mm probes.\u003c\/p\u003e\n\u003ch3\u003eSignal Converter Logic\u003c\/h3\u003e\n\u003cp\u003eThe CON041 acts as the driver unit, supplying high-frequency excitation to the sensor and demodulating the returned signal into a linear negative voltage output.\u003c\/p\u003e\n\u003ch3\u003eImpedance Matching\u003c\/h3\u003e\n\u003cp\u003eThe system is factory-calibrated as a matched pair. The inductance characteristics of the PR6426\/000-131 are precisely aligned with the CON041 circuitry to minimize drift and maintain measurement stability.\u003c\/p\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis configuration is fully compatible with Emerson AMS 6500 and MMS 6000 protection systems, allowing seamless integration into plant-wide condition monitoring and asset management platforms.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6426\/000-131 CON041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (Epro)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e8.0 mm (Standard Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (Sensor Tip)\u003c\/td\u003e\n\u003ctd\u003e-35 to +175°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (Converter)\u003c\/td\u003e\n\u003ctd\u003e-20 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-24 VDC (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003ch3\u003eHow does the CON041 handle long-distance signal transmission?\u003c\/h3\u003e\n\u003cp\u003eThe converter outputs a low-impedance voltage signal that remains stable over long cable runs. Using shielded twisted-pair cables helps prevent EMI interference and ensures measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eIs this system compatible with different shaft materials?\u003c\/h3\u003e\n\u003cp\u003eThe standard calibration is optimized for 42CrMo4 steel. If the shaft material differs, material-specific calibration may be required to maintain the 1.5% linearity specification.\u003c\/p\u003e\n\u003ch3\u003eCan the PR6426 sensor be replaced independently?\u003c\/h3\u003e\n\u003cp\u003eThe sensor and converter are modular, but they must share the same configuration. After replacing either component, recalibration of the gap voltage is required to ensure correct operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eGap Voltage Optimization\u003c\/h3\u003e\n\u003cp\u003eFor an 8.0 mm range, adjust the probe gap so the static output voltage sits near the center of the linear range, typically around -10 VDC. This configuration allows maximum vibration amplitude measurement without signal clipping.\u003c\/p\u003e\n\u003ch3\u003eSide Clearance Protocol\u003c\/h3\u003e\n\u003cp\u003eMaintain at least 20 mm radial clearance from surrounding metallic structures. Nearby metal objects can distort the magnetic field and introduce measurement errors.\u003c\/p\u003e\n\u003ch3\u003eMounting Rigidity\u003c\/h3\u003e\n\u003cp\u003eUse rigid stainless-steel brackets for mounting. Any vibration from the mounting structure may be interpreted as shaft vibration and trigger false alarms.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe PR6426\/000-131 CON041 system offers excellent thermal stability, with the sensor tip capable of continuous operation up to 175°C. The 12 mm probe diameter allows a larger operating gap, reducing the risk of mechanical contact during transient surge conditions.\u003c\/p\u003e\n\u003cp\u003eIts backward compatibility with legacy Philips epro equipment also makes it ideal for retrofitting existing turbomachinery protection systems without requiring mechanical redesign or major installation changes.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695424663915,"sku":"PR6426\/000-131 CON041","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR6426_000-131CON041.png?v=1775912173"},{"product_id":"pr6423-10r-040-emerson-epro-eddy-current-displacement-sensor","title":"PR6423\/10R-040 Emerson Epro Eddy Current Displacement Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR6423\/10R-040\u003c\/strong\u003e is a high-precision non-contact eddy current displacement sensor engineered for turbomachinery protection within Turbine Supervisory Instrumentation (TSI) systems. Operating on a contactless inductive measurement principle, this sensor measures shaft vibration, axial position, and eccentricity in high-speed rotating machinery. It outputs a proportional voltage signal that interfaces with machinery protection systems to assist in monitoring mechanical conditions and managing system downtime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFrictionless operation via a contactless inductive measurement principle\u003c\/li\u003e\n\u003cli\u003eRuggedized 8 mm diameter sensing tip constructed from ceramics and stainless steel\u003c\/li\u003e\n\u003cli\u003eHigh-durability armored jacket designed to withstand physical stresses during conduit routing\u003c\/li\u003e\n\u003cli\u003eOutput signal compatibility with machinery protection systems for real-time analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine shaft vibration and axial position monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed compressor eccentricity tracking\u003c\/li\u003e\n\u003cli\u003eGearbox asset protection in power plants, refineries, and industrial pumping stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson (Epro)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/10R-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (0.157 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 meters (Integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eReinforced \/ Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +175 deg C (Tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 20 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSet the sensor at its electrical center during installation, which typically corresponds to -10 VDC for a standard converter, by monitoring the gap voltage with a voltmeter while adjusting the mounting thread.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clear radius of 15 mm around the sensing tip to prevent metallic objects from distorting the magnetic field and causing false readings.\u003c\/li\u003e\n\u003cli\u003eAvoid routing the armored sensor cable parallel to high-voltage power lines, utilize dedicated instrument trays, and ground the cable armor exclusively at the machine housing to avoid noise induction from ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003efrom ground loops.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695425122667,"sku":"PR6423\/10R-040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PR6423_10R-040.png?v=1775910705"}],"url":"https:\/\/www.plcprotech.com\/uz\/collections\/epro-eddy-current-sensors-probes.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}