{"product_id":"adv141-p12-s1-yokogawa-centum-vp-ac-digital-input-module","title":"ADV141-P12 S1 Yokogawa CENTUM VP AC Raqamli Kirish Moduli","description":"\u003ch3\u003eMahsulot Sharhi\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eADV141-P12 S1 (ADV141)\u003c\/strong\u003e — bu Yokogawa CENTUM VP tarqatilgan boshqaruv tizimi (DCS) uchun mo‘ljallangan yuqori zichlikdagi, 16-kanalli izolyatsiyalangan AC raqamli kirish moduli. 100 dan 120 V AC gacha bo‘lgan nominal kuchlanish oralig‘ida ishlaydigan ushbu modul sanoat maydon qurilmalari, masalan, limit kalitlari, motor starterlari va tugmachalar uchun muhim holat monitoringi va impuls hisoblash imkoniyatlarini taqdim etadi. Neftni qayta ishlash zavodlari va neft-kimyo korxonalari kabi murakkab jarayon muhitlarida \u003cstrong\u003eADV141\u003c\/strong\u003e yuqori aniqlikdagi signal olishni 160 ms javob vaqti bilan ta’minlaydi. Uning yuqori darajadagi izolyatsiyasi va G3 atrof-muhitga chidamliligi korroziy yoki issiqlik jihatdan o‘zgaruvchan joylarda tizim ish faoliyatini saqlash uchun asosiy element hisoblanadi. FIO (Maydon tarmog‘i I\/O) subsistemasiga aniq real vaqtdagi diagnostika ma’lumotlarini yetkazib berish orqali ushbu modul rejalashtirilmagan to‘xtashlarni oldini olish va missiya uchun muhim infratuzilmalarda xavfsizlikni ta’minlashda muhim rol o‘ynaydi.\u003c\/p\u003e\n\u003ch3\u003eQo‘shimcha Belgilarning Tahlili\u003c\/h3\u003e\n\u003cp\u003eUshbu maxsus birlik uchun qo‘shimcha konfiguratsiya uning takomillashgan apparat imkoniyatlari va atrof-muhit talablari quyidagicha aniqlanadi:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e Tugmacha kirish funksiyasi bilan jihozlangan bo‘lib, modul tugmacha chekkalarini 200 ms minimal aniqlash vaqti bilan hisoblash imkonini beradi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e Standart apparat konfiguratsiyasi, integratsiyalangan holat ko‘rsatkichlarisiz; portlashdan himoyalanmagan sifatida tasniflanadi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2:\u003c\/strong\u003e Korroziyaga chidamlilik uchun ilg‘or ISA Standart G3 konformal qoplamasi, shuningdek, -20 dan 70 daraja S gacha kengaytirilgan ish harorati oralig‘i.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS1:\u003c\/strong\u003e CENTUM VP integratsiyasi uchun maxsus apparat takomillashtirishlari bilan standart tur sifatida belgilangan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModul Texnik Xususiyatlari\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eElement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTexnik Xususiyatlar\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eADV141-P12 S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrend\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKelib chiqishi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYaponiya\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKanallar soni\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Izolyatsiyalangan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal kirish kuchlanishi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 dan 120 V AC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKirish ON kuchlanishi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 V AC (113 V Peak) dan 132 V AC gacha\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKirish OFF kuchlanishi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 V AC (28 V Peak) yoki undan kam\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaksimal tok iste’moli\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mA (5 V DC da)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsh harorati\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 dan 70 daraja S gacha\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChidamlilik kuchlanishi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKirish va tizim o‘rtasida 2 kV AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOg‘irligi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTashqi ulanish\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBosim qisqich terminali yoki AKB332 kabeli\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMuhandislik Maslahatlari (Tez-tez so‘raladigan savollar)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eADV141 tugmacha kirishlarini standart holat kirishlaridan qanday farq bilan boshqaradi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-P qo‘shimchasi bilan sozlanganida, modul tugmacha chekkalarini hisoblash uchun maxsus ichki funksiyadan foydalanadi. Standart holat kirishlari ON\/OFF holatini aniqlashga qaratilgan bo‘lsa, tugmacha rejimi aniq impulslarni ushlash uchun minimal 200 ms ON aniqlash vaqtini va maksimal 2.5 Hz sikl tezligini talab qiladi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eYuqori zichlikdagi terminal ulanishlari uchun qanday kabel talab qilinadi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eADV141 uchun Yokogawa maxsus AKB332 kabelini tavsiya qiladi. Bu impedans mosligini ta’minlaydi va 16 izolyatsiyalangan kanalni terminal platasiga ulashni soddalashtiradi, ishga tushirish vaqtida simlarni noto‘g‘ri ulash ehtimolini kamaytiradi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUshbu modul uchun aniq izolyatsiya chegaralari qanday?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModul kirish signali va tizim logikasi o‘rtasida 1 daqiqa davomida 2 kV AC izolyatsiyasini ta’minlaydi. Bundan tashqari, har 8-kanalli guruh uchun umumiy minus tomonlar o‘rtasida 1.35 kV AC izolyatsiyasi mavjud bo‘lib, bu o‘zaro aralashuvni oldini oladi va tizim orqa panelini maydon tomonidagi kuchlanish o‘zgarishlaridan himoya qiladi.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMuhandislik va O‘rnatish Qo‘llanmasi\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtrof-muhit himoyasi:\u003c\/strong\u003e \"G3\" reytingi ushbu modulning ISA S71.04 standartiga muvofiq konformal qoplama bilan ishlanganligini bildiradi. Bu gidrogen sulfid (H2S) yoki xlor gazining yuqori darajada bo‘lgan \"G3 sinfi\" muhitlarda o‘rnatish uchun zarur. Shkafni yopiq holda saqlang va ichki harorat 70 daraja S ga yaqinlashganda sovutish ventilyatorlaridan foydalaning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimlash va Ekranlash:\u003c\/strong\u003e Bosim qisqich terminalari uchun 14 dan 22 AWG gacha simlardan foydalaning. Yaqin atrofdagi yuqori kuchlanishli elektr liniyalaridan elektromagnit shovqinni (EMI) kamaytirish uchun maydon simlarini burish kerak. Umumiy qaytish chiziqlari 8-kanalli izolyatsiya bloklari bo‘yicha to‘g‘ri guruhlanganligiga ishonch hosil qiling, bu chidamlilik kuchlanishi ko‘rsatkichlarini saqlash uchun muhimdir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTizim yaxlitligi:\u003c\/strong\u003e Modulni almashtirishda, CENTUM VP quruvchi dasturida Suffix kodlari tizim konfiguratsiyasiga mos kelishini tekshiring. Issiq almashtirish qo‘llab-quvvatlanadi, ammo tashqi AC quvvat kirish terminallaridan uzilganligiga ishonch hosil qiling, bu yong‘in va 120 V AC ta’siridan xodimlarni himoya qilish uchun zarur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695400415595,"sku":"ADV141-P12 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-adv141-p12-s1-digital-input-module-20thg1gvqxj_75688d27-f463-4525-869f-a40286643a98.jpg?v=1766133705","url":"https:\/\/www.plcprotech.com\/uz\/products\/adv141-p12-s1-yokogawa-centum-vp-ac-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}