{"product_id":"allen-bradley-1756-ox8i-controllogix-digital-i-o-module","title":"Allen-Bradley 1756-OX8I ControlLogix raqamli I\/O moduli","description":"\u003cp\u003e\u003cstrong\u003eAllen-Bradley 1756-OX8I\u003c\/strong\u003e moduli ControlLogix tizimlariga integratsiya qilish uchun mo'ljallangan sakkizta izolyatsiyalangan raqamli chiqish kontaktlarini taqdim etadi. Ushbu qurilma AC va DC kuchlanish diapazonlarini qo'llab-quvvatlaydi, turli sanoat ilovalarida boshqaruvni ta'minlaydi. 1756-OX8I alohida izolyatsiyalangan chiqish guruhlariga ega bo'lib, murakkab elektr muhitlarida xavfsiz va ishonchli ishlashni kafolatlaydi. ControlLogix orqa panellari bilan muammosiz moslashuv uchun ishlab chiqilgan modul avtomatlashtirish arxitekturalarida oson o'rnatish va texnik xizmat ko'rsatishni ta'minlaydi. Ushbu modul rele asosidagi ishga tushirish, holat ko'rsatkichlari va kichik motor boshqaruvi kabi mustahkam kontakt chiqishlarini talab qiladigan ilovalar uchun ideal. Uning izolyatsiyalangan dizayni yer aylanishlarini kamaytiradi va shovqin qarshiligini oshiradi, bu esa uni talabchan sanoat sharoitlari uchun mos qiladi.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlar\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e8 ta N.O. (Odatda ochiq) rele kontaktlarini taqdim etadi.\u003c\/li\u003e\n\u003cli\u003eElektr shovqinini kamaytirish uchun alohida izolyatsiyalangan chiqish guruhlari (har guruhda ikki nuqta).\u003c\/li\u003e\n\u003cli\u003eKeng kuchlanish diapazonida ishlaydi: AC (10...240V) yoki DC (5...125V).\u003c\/li\u003e\n\u003cli\u003eIshonchli o'tkazish uchun yuqori pilot yuklamasi reytingi (C300\/R150).\u003c\/li\u003e\n\u003cli\u003eNosozlik rejimi va rejalashtirilgan chiqishlar uchun holat ko'rsatkichlarini o'z ichiga oladi.\u003c\/li\u003e\n\u003cli\u003eNoto'g'ri modul o'rnatilishini oldini olish uchun dasturiy ta'minot bilan sozlanadigan elektron kalitlash.\u003c\/li\u003e\n\u003cli\u003eSamarali issiqlik tarqalishi uchun ochiq turdagi qopqoq dizayni.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIlovalar\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eTashqi relelar, solenoidlar va kontaktorlarni boshqarish.\u003c\/li\u003e\n\u003cli\u003eJarayon asbob-uskunalari uchun holat chiqishlarini taqdim etish.\u003c\/li\u003e\n\u003cli\u003eKo'rsatkich chiroqlarini yoki eshitish signalizatsiyasini boshqarish.\u003c\/li\u003e\n\u003cli\u003eGibrid tizimlarda PLC boshqarilmaydigan mashinalar bilan interfeys.\u003c\/li\u003e\n\u003cli\u003eIzolyatsiyalangan sxemalarda kichik o'lchamli motorni ishga tushirish\/to'xtatish boshqaruvi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTexnik xususiyatlar \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eXususiyat\u003c\/th\u003e\n\u003cth\u003eQiymat\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqishlar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ta N.O. (Odatda ochiq), alohida izolyatsiyalangan (har guruhda ikki nuqta)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot yuklamasi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300\/R150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlash kuchlanish diapazoni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...125V DC10...240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKontakt joriy reytingi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A @ 5...30V DC0.5 A @ 48V DC0.22 A @ 125V DC1.5 A @ 250V AC 50\/60 Gts0.75 A @ 480V AC 50\/60 Gts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish kechikish vaqti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eO'chirilgandan yoqilganga: maksimal 13 msYoqilgandan o'chirilganga: maksimal 13 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJoriy tortish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e@ 5.1V: 800 mA@ 24V: 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmumiy orqa panel quvvati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuvvat sarfi, maksimal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 W @ 60 daraja S (140 daraja F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIssiqlik tarqalishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.57 BTU\/soat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO'chirilgan holat oqimi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimal yuk oqimi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNuqtada minimal yuk oqimi 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoshlang'ich kontakt qarshiligi, maksimal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mOhm @ 6V 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO'tkazish chastotasi, maksimal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ta amal\/3 s (reyting yukida 0.3 Gts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO'rtacha sakrash vaqti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKutilayotgan kontakt muddati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300,000 sikl qarshilikli100,000 sikl induktiv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRejalashtirilgan chiqishlar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e167.6 ms ichida sinxronizatsiya, Muvofiqlashtirilgan tizim vaqtiga nisbatan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNosozlik rejimidagi holatlar nuqtada\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOxirgi holatni ushlab turish, Yoqilgan yoki O'chirilgan (O'chirilgan standart)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDastur rejimidagi holatlar nuqtada\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOxirgi holatni ushlab turish, Yoqilgan yoki O'chirilgan (O'chirilgan standart)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIzolyatsiya kuchlanishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V (uzluksiz), asosiy izolyatsiya turi, chiqishlar orqa panelga va chiqishdan chiqishga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModul kalitlash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElektron, dasturiy ta'minot bilan sozlanadigan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFyuzyon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHimoyalanmagan. Chiqishlarni himoya qilish uchun IF6H sig‘imli tavsiya etiladi.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOlib tashlanadigan terminal bloki\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH1756-TBS6H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTB kalitlash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFoydalanuvchi belgilagan mexanik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot kengligi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSim toifasi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ep(1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQopqoq turi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYo‘q (ochiq tur)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShimoliy Amerika harorat kodi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\n\u003cp\u003e(1) Ushbu o‘tkazgich toifasi ma’lumotlarini tizim darajasidagi o‘rnatish qo‘llanmasida ko‘rsatilganidek o‘tkazgich yo‘nalishini rejalashtirish uchun foydalaning. Sanoat avtomatlashtirish simlash va yerga ulash bo‘yicha ko‘rsatmalar, 1770-4.1 nashri.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eAtrof-muhit spetsifikatsiyalari\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eXususiyat\u003c\/th\u003e\n\u003cth\u003eQiymat\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarorat, ishlayotganda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)IEC 60068-2-1 (Ab testi. Ishlayotgan sovuq)IEC 60068-2-2 (Bb testi. Ishlayotgan quruq issiqlik)IEC 60068-2-14 (Nb testi. Ishlayotgan termal zarba)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarorat, ishlamayotganda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...+185 degF)IEC 60068-2-1 (Ab testi. Qadoqsiz ishlamayotgan sovuq)IEC 60068-2-2 (Bb testi. Qadoqsiz ishlamayotgan quruq issiqlik)IEC 60068-2-14 (Na testi. Qadoqsiz ishlamayotgan termal zarba)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNisbiy namlik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% kondensatsiyasizIEC 60068-2-30 (Db testi. Qadoqsiz namlik)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibratsiya\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g, 30...500 HzIEC 60068-2-6 (Fc testi. Ishlayotganda)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZarba, ishlayotganda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 gIEC 60068-2-27 (Ea testi. Qadoqsiz zarba)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZarba, ishlamayotganda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 gIEC 60068-2-27 (Ea testi. Qadoqsiz zarba)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqindilar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD immuniteti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV kontakt zaryadlari8 kV havo zaryadlariIEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiatsiyalangan RF immuniteti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V\/m, 1kHz sinus to‘lqin, 80% AM, 80...2000 MHz oralig‘ida10V\/m, 200 Hz, 50% impuls, 100% AM @ 800 MHz10V\/m, 200 Hz, 50% impuls, 100% AM @ 880 MHz30V\/m, 1kHz sinus to‘lqin, 80% AM, 2000...2700 MHz oralig‘idaIEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEFT\/portlash immuniteti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+-4 kV, 5 kHz signal portlaridaIEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO‘tkazilgan to‘lqin immuniteti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+-1 kV chiziq-chiziq (DM) va +-2 kV chiziq-zamin (CM) signal portlaridaIEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO‘tkazilgan RF immuniteti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V rms, 1 kHz sinus to‘lqin, 80% AM, 150 kHz...80 MHz oralig‘idaIEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSertifikatlar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSertifikatlash(1)\u003c\/th\u003e\n\u003cth\u003eTafsilotlar\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL ro‘yxatga olingan sanoat boshqaruv uskunalari, AQSh va Kanada uchun sertifikatlangan. UL faylini ko‘ring E48599.UL ro‘yxatga olingan, I sinf, 2-bo‘lim, A,B,C,D guruh xavfli joylar uchun, AQSh va Kanada uchun sertifikatlangan. UL faylini ko‘ring E49480.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYevropa Ittifoqi 2014\/30\/EU EMC Direktivi, quyidagilarga muvofiq:• EN 61326-1: O‘lchash, boshqaruv va laboratoriya uskunalari. Sanoat talablari• EN 61000-6-2: Sanoat immuniteti• EN 61000-6-4: Sanoat chiqindilari• EN 61508-2: Dasturlashtiriladigan boshqaruvchilar (8.2-band, A va B zonalari)• EN 61508-2: Dasturlashtiriladigan boshqaruvchilar (II-band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYevropa 2014\/35\/EU LVD, EN 61010-2 ga muvofiq: Dasturlashtiriladigan boshqaruvchilarAvstraliya Radiokommunikatsiya Qonuni, EN 61000-6-4 ga muvofiq: Sanoat chiqindilari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFM tasdiqlangan uskunalar, I sinf, 2-bo‘lim, A,B,C,D guruh xavfli joylarda foydalanish uchun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadio to‘lqinlari to‘g‘risidagi Qonunning 58-2-moddasi, 3-bandiga muvofiq Koreya Broadcasting va Kommunikatsiya Uskunalari Ro‘yxatga olish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUKCA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuyidagi Buyuk Britaniya qonuniy hujjatlari va ularning o‘zgartirishlariga muvofiq:• 2016 yil 109-son: Elektromagnit Moslik Qoidalari• 2016 yil 1101-son: Elektr jihozlari (Xavfsizlik) Qoidalari• 2016 yil 107-son: Potentsial portlashli muhitda foydalanish uchun mo‘ljallangan jihozlar va himoya tizimlari Qoidalari• 2012 yil 3032-son: Elektr va elektron jihozlarda ba’zi xavfli moddalar ishlatilishini cheklash Qoidalari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarokash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1er muharram 1437 yil (2015 yil 15 oktyabr) sanasidagi 04-15 raqamli vazirlik farmoni Elektr jihozlarini kuchlanish ta’siridan himoya qilishga oid qo‘llanma 29 ramazon 1436 yil (2015 yil 16 iyul) sanasidagi 04-15 raqamli vazirlik farmoni Elektr jihozlarining elektromagnit mosligi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\n\u003cp\u003e(1) Mahsulot sotuvga chiqarilganda. Moslik deklaratsiyalari, sertifikatlar va boshqa sertifikatlash tafsilotlari uchun \u0026lt;a href=\"#\"\u0026gt;ra.rockwellautomation.com\u0026lt;\/a\u0026gt; saytidagi Mahsulot Sertifikati havolasiga qarang.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eUlanishlar va interfeyslar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUlagich \/ Terminal\u003c\/th\u003e\n\u003cth\u003eFunktsiya \/ Elektr sxemasi tayinoti\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTa’minot ulanishlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eL1-0 dan L1-7 gacha\u003c\/strong\u003e: Izolyatsiyalangan AC\/DC ta’minot umumiylari (Kerakli uzunlikda kesilgan)• \u003cstrong\u003eDC-2 (H)\u003c\/strong\u003e: Izolyatsiyalangan DC ta’minot umumiy (Kerakli uzunlikda kesilgan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish ulanishlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eOUT-0 N.O. dan OUT-7 N.O.gacha\u003c\/strong\u003e: Alohida izolyatsiyalangan Form A (Odatda ochiq) rele kontaktlari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMexanik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• \u003cstrong\u003eJumper Bar\u003c\/strong\u003e: L1 ta’minotini qo‘shni RTBlarga zanjirga ulash uchun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ci\u003eEslatma: Ulanishlar olib tashlanadigan 36-pinli terminal bloki (1756-TBCH yoki 1756-TBS6H) orqali amalga oshiriladi.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eMaydon o‘rnatish ko‘rsatmalari\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eMUHIM XAVF BAHOLASHI:\u003c\/strong\u003e ARC FLASH XAVFI VA PORTLASH IMKONIYATI. Faol chiziq kuchlanishlari kontakt tugatish bloklariga uzatilayotgan paytda mexanik sim bog‘lamlarini uzmang yoki Olib tashlanadigan Terminal Blokini (RTB) qulflash ulagichlaridan tortib olmang. Rele chiqish pinlarida yuqori potentsial energiya maydonlari arc hosil qilishi mumkin, bu modulni yo‘q qilishi yoki mahalliy quvvat uzilishlarini keltirib chiqarishi mumkin.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eShassi moslashuvi:\u003c\/strong\u003e Modulning plastik karta yo‘riqchilarini 1756 ControlLogix shassi bankidagi maqsadli slotning yuqori va pastki kanallari bilan moslang.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eJoylashtirish mexanizmi:\u003c\/strong\u003e Majmua ichkariga qattiq suring, to‘g‘ri qulflash tasmachalari joyida bosish tovushi bilan mahkamlanib, ikki ulagichli yadroni faol orqa panel interfeysiga bog‘laydi.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eMaydon simlarini tugatish:\u003c\/strong\u003e Maydon kabellaringizni kerakli uzunlikda qirqib oling, izolyatsiyalangan AC\/DC quvvat liniyalarini maxsus 36-pinli RTB terminal bloklariga ulang va siqish terminal vintlarini standart chegaralarga qadar mahkamlang.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eO‘tkir kuchlanishdan himoya:\u003c\/strong\u003e Ichki mexanik rele kontaktlarini yuqori kuchlanishli induktiv orqaga urilishlardan himoya qilish uchun tashqi o‘tkir kuchlanishdan himoya qiluvchi qurilmalarni (masalan, varistorlar yoki snabberlar) induktiv maydon yuklari bo‘ylab to‘g‘ridan-to‘g‘ri o‘rnating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eRTB ulanishi:\u003c\/strong\u003e Oldindan simlangan 1756-TBCH yoki 1756-TBSH blokini interfeys pinlari ustiga to‘g‘ridan-to‘g‘ri suring, qulflash tutqichini pastga bosib mahkamlang va maydon interfeysini mustahkamlash uchun markaziy ushlab turuvchi vintlarni qattiq burang.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695172677995,"sku":"1756-OX8I","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-ox8i-isolated-contact-module-xirxw3mjtin_11a2dd27-c449-4465-b3dc-73953d8a42ac.jpg?v=1766114098","url":"https:\/\/www.plcprotech.com\/uz\/products\/allen-bradley-1756-ox8i-controllogix-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}