{"product_id":"allen-bradley-1761-net-dni-slc-500-devicenet-interface-controller","title":"Allen-Bradley 1761-NET-DNI SLC 500 DeviceNet interfeys kontrolleri","description":"\u003ch3\u003eTavsif\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAllen-Bradley 1761-NET-DNI\u003c\/strong\u003e — DF1 ketma-ket qurilmalarini, jumladan MicroLogix, SLC 500 va PLC-5 kontrollerlari yoki MicroView operator interfeyslarini DeviceNet sanoat tarmog‘iga uzluksiz ulash uchun ishlab chiqilgan maxsus DeviceNet interfeys kontrolleridir. Tarmoq aloqa adapteri sifatida ishlaydigan qurilma standart DF1 nuqtadan nuqtaga ketma-ket protokollarini DeviceNet talablariga mos xabar tuzilmalariga o‘giradi. Bu eski yoki mustaqil kontrollerlarga taqsimlangan I\/O arxitekturalari va teng huquqli qurilmalar o‘rtasidagi boshqaruv strategiyalarida ishtirok etish imkonini beradi.\u003c\/p\u003e\n\u003cp\u003eSeries B yaxshilanishlari bilan \u003cstrong\u003e1761-NET-DNI\u003c\/strong\u003e DeviceNet orqali master\/slave I\/O xabarlarini hamda to‘g‘ridan-to‘g‘ri explicit xabarlarni yuborishni qo‘llab-quvvatlaydi. Tizimni RS-232 ketma-ket porti orqali DNI Configuration Software Utility yordamida mahalliy tarzda yoki RSNetWorx for DeviceNet dasturi va tegishli Electronic Data Sheet (EDS) fayllari yordamida tarmoq orqali sozlash mumkin. Input Split Point va Output Split Point kabi ilg‘or parametrlar xotirani davriy I\/O ma’lumotlari va explicit assembly xabarlari o‘rtasida aniq taqsimlash imkonini beradi. Bundan tashqari, maxsus DF1 Substitution Address funksiyasi ketma-ket operator interfeyslariga DeviceNet ulanishi orqali kontrollerlarga so‘rov yuborish va ular bilan uzluksiz aloqa qilish imkonini beradi.\u003c\/p\u003e\n\u003ch3\u003eFunksiyalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1-ni DeviceNet protokoliga aylantirish:\u003c\/strong\u003e MicroLogix va SLC 500 kontrollerlarini o‘z ichiga olgan DF1 ketma-ket qurilmalarini DeviceNet sanoat tarmoqlariga bevosita integratsiya qilish imkonini beradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplicit xabarlar imkoniyati:\u003c\/strong\u003e Series B funksiyalari modulga DeviceNet orqali explicit xabarlarni yuborish va istalgan vaqtda explicit assemblylarga yuborilgan xabarlarni qabul qilish imkonini beradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSozlanadigan ma’lumotlarni ajratish nuqtalari:\u003c\/strong\u003e Master\/Slave davriy I\/O va explicit xabarlar o‘rtasida xotiradan foydalanishni moslashuvchan tarzda muvozanatlash uchun foydalanuvchi belgilaydigan Input Split Point va Output Split Point parametrlarini o‘z ichiga oladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMahalliy RS-232 orqali sozlash:\u003c\/strong\u003e Maxsus DNI Configuration Software Utility yordamida RS-232 ketma-ket porti orqali parametrlarni bevosita sozlashni qo‘llab-quvvatlaydi; shu tariqa mustaqil sozlashda tarmoq interfeysi konvertorlariga ehtiyoj qolmaydi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1 Substitution Address:\u003c\/strong\u003e MicroView terminallari kabi DF1 qurilmalariga xabarlarni tarmoq orqali Allen-Bradley kontrollerlariga shaffof tarzda yo‘naltirish imkonini beruvchi maxsus almashtirish parametriga ega.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDinamik ish boshqaruvi:\u003c\/strong\u003e Tarmoqni boshqarishni soddalashtirish uchun Electronic Data Sheet (EDS) tarkibidagi eski Standby\/Operational parametrlarini I\/O Scan Enable boshqaruv parametri bilan almashtiradi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo‘llanilishi\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC tarmog‘iga integratsiya:\u003c\/strong\u003e DF1 ketma-ket portlaridan foydalanadigan SLC 500 va MicroLogix kontrollerlarini markazlashtirilgan DeviceNet boshqaruv arxitekturalariga ulaydi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHMI \/ operator interfeysini kengaytirish:\u003c\/strong\u003e Ketma-ket operator terminallariga DeviceNet kabel tarmog‘i orqali uzoqdagi PLC-lardan boshqaruv ma’lumotlarini olish imkonini beradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTaqsimlangan teng huquqli xabar almashinuvi:\u003c\/strong\u003e Umumiy DeviceNet tarmoq segmentidagi mustaqil mashina kontrollerlari o‘rtasida explicit xabar almashinuvini ta’minlaydi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTexnik xususiyatlar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eXususiyat\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIshlab chiqaruvchi\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMahsulot oilasi\u003c\/td\u003e\n\u003ctd\u003eMicroLogix \/ SLC 500 tarmoq interfeyslari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKatalog raqami\u003c\/td\u003e\n\u003ctd\u003e1761-NET-DNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparat seriyasi\u003c\/td\u003e\n\u003ctd\u003eSeries B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMahsulot turi\u003c\/td\u003e\n\u003ctd\u003eDeviceNet interfeys kontrolleri\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarmoq protokoli\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMahalliy protokol\u003c\/td\u003e\n\u003ctd\u003eDF1 to‘liq dupleks \/ DF1 yarim dupleks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSozlash dasturi bilan mosligi\u003c\/td\u003e\n\u003ctd\u003eRSNetWorx for DeviceNet (v2.11.36 yoki undan yuqori), DNI Configuration Utility (DNI_UTIL_B.EXE v2.001 yoki undan yuqori)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTalab qilinadigan EDS fayllari\u003c\/td\u003e\n\u003ctd\u003e1761DNI3.EDS (FRN 2.02 yoki undan past), 1761DNI4.EDS (FRN 2.03 yoki undan yuqori)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplicit xabarlar\u003c\/td\u003e\n\u003ctd\u003eQo‘llab-quvvatlanadi (yuborish va qabul qilish)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSozlash porti\u003c\/td\u003e\n\u003ctd\u003eRS-232 ketma-ket porti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUlanishlar \/ interfeyslar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ interfeys\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunksiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232 porti\u003c\/td\u003e\n\u003ctd\u003eDF1 protokolidan foydalanib, asosiy PLC ketma-ket porti yoki sozlash kompyuteriga ulanadi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet ulagichi\u003c\/td\u003e\n\u003ctd\u003eMagistral\/tarmoq shoxobchasiga ulanish uchun 5 kontaktli ochiq turdagi ulagich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eO‘rnatish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eO‘rnatishdan oldingi tekshiruv:\u003c\/strong\u003e 1761-NET-DNI qurilmasini qutisidan chiqaring va korpusi hamda ulagichlarida jismoniy shikastlanish bor-yo‘qligini tekshiring. Apparat reviziyasi (Series B) loyiha talablariga mosligini tasdiqlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO‘rnatish:\u003c\/strong\u003e Qurilmani ish muhiti uchun mos himoya darajasiga ega korpus ichida standart DIN-reyka yoki panelga o‘rnatish moslamalari yordamida mahkam o‘rnating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuvvat va yerga ulash:\u003c\/strong\u003e DeviceNet magistral tarmog‘i bo‘ylab to‘g‘ri quvvat berish va ekranlash talablariga rioya qiling. Elektromagnit xalaqitlarni kamaytirish uchun signal simlarini yuqori kuchlanishli o‘zgaruvchan tok liniyalaridan alohida yotqizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKetma-ket ulanish:\u003c\/strong\u003e 1761-NET-DNI ketma-ket porti bilan MicroLogix, SLC 500 yoki asosiy qurilmaning DF1 ketma-ket kanali o‘rtasida RS-232 aloqa kabelini ulang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarmoqqa ulanish:\u003c\/strong\u003e 5 o‘tkazgichli DeviceNet shoxobcha kabelini tarmoq ulagichiga ulang. Quvvat ($V+$, $V-$), signallar ($CAN\\_H$, $CAN\\_L$) va ekran uchun kontaktlar to‘g‘ri moslanganiga ishonch hosil qiling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSozlash bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEDS faylini o‘rnatish:\u003c\/strong\u003e To‘g‘ri Electronic Data Sheet (FRN $\\le 2.02$ uchun 1761DNI3.EDS yoki FRN $\\ge 2.03$ uchun 1761DNI4.EDS) RSNetWorx for DeviceNet dasturida ro‘yxatdan o‘tkazilganini tekshiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMahalliy ketma-ket sozlash:\u003c\/strong\u003e RS-232 ketma-ket porti orqali DNI Configuration Software Utility (DNI_UTIL_B.EXE) dasturidan foydalanib, tugun manzillari, bod tezliklari va ketma-ket port parametrlarini sozlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAjratish nuqtalarini taqsimlash:\u003c\/strong\u003e Tizim talablariga muvofiq ma’lumotlar buferi hajmlarini Master\/Slave I\/O va explicit xabar assemblylari o‘rtasida taqsimlash uchun Input Split Point va Output Split Point parametrlarini belgilang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDF1 Substitution Addressni sozlash:\u003c\/strong\u003e Ketma-ket HMI yoki MicroView ulanayotgan bo‘lsa, DeviceNet tarmog‘idagi maqsad kontroller manzillariga kiruvchi ketma-ket so‘rovlarni moslashtirish uchun DF1 Substitution Address parametrini sozlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries A dan ko‘chirish eslatmasi:\u003c\/strong\u003e Series A konfiguratsiya fayllari Series B apparati bilan bevosita mos kelmasligini inobatga oling; xabar almashish arxitekturasi yaxshilangani sababli parametrlarni Series B qurilmasiga qo‘lda qayta kiritish kerak.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53770304717163,"sku":"1761-NET-DNI","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1761-NET-DNI_001_1200x1200_37d182cb-f18b-405e-91df-5222acf90877.png?v=1788446337","url":"https:\/\/www.plcprotech.com\/uz\/products\/allen-bradley-1761-net-dni-slc-500-devicenet-interface-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}