{"product_id":"bently-nevada-125800-01-3500-25-keyphasor-i-o-module","title":"Bently Nevada 125800-01 3500\/25 Keyphasor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 125800-01\u003c\/strong\u003e is an internal termination Keyphasor I\/O module designed for use with the 3500\/25 Enhanced Keyphasor Module within a 3500 Machinery Protection System rack. The \u003cstrong\u003e125800-01\u003c\/strong\u003e receives input signals directly from proximity probes or magnetic pickups and delivers phase and speed timing signals to monitor modules across the rack system. Installed in a full-height rear slot, this non-isolated I\/O module provides direct internal wiring terminal connections and rear buffered Keyphasor signal outputs for machine diagnostics and TSI monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect internal termination connections using Euro-style\/screw terminal blocks for transducer field wiring\u003c\/li\u003e\n\u003cli\u003eDual-channel transducer input handling for proximity probe and magnetic pickup signals\u003c\/li\u003e\n\u003cli\u003eRear-panel buffered Keyphasor signal outputs via terminal headers\u003c\/li\u003e\n\u003cli\u003eSeamless integration with 3500\/25 main half-height cards across legacy and current 3500 system racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection systems requiring once-per-turn or multi-event timing reference signals\u003c\/li\u003e\n\u003cli\u003eShaft rotative speed and phase angle (1X vibration amplitude\/phase) tracking\u003c\/li\u003e\n\u003cli\u003eTurbine, compressor, and large rotating equipment condition monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125800-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+0.8 V to -21.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.8 kOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed\/Frequency Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput: 1 to 1,200,000 cpm (0.017 to 20 kHz); Output: 1 to 99,999 cpm (0.017 to 1667 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Signal Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.017 to 100 Hz: +\/-1 cpm; 101 to 500 Hz: +\/-8 cpm; 501 to 20 kHz: +\/-1% of cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, 40 mA maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504 Ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 103.1 mm (9.50 in x 0.96 in x 4.06 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - PWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power (-24 Vdc) Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Common Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - KPH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyphasor Signal Input Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - SHLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Cable Shield Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - PWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power (-24 Vdc) Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Common Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - KPH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyphasor Signal Input Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - SHLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Cable Shield Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Output Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM (BUF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Common Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Output Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM (BUF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Common Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSHIELD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Ground\/Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Placement:\u003c\/strong\u003e Mount the I\/O module in the full-height rear slot directly behind the corresponding 3500\/25 main half-height module position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Shielding:\u003c\/strong\u003e Connect transducer field wiring to the internal terminal blocks (PWR, COM, KPH, SHLD). Ensure shield wires are properly landed at the assigned SHLD terminals to prevent signal noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Compatibility:\u003c\/strong\u003e Do not attempt to connect External Termination (ET) blocks or cables to this internal termination module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area (cNRTLus):\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area (ATEX\/IECEx):\u003c\/strong\u003e Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units); ABS Rules for Condition of Classification Part 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU; China RoHS SJ\/T 11364-2024\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866336107,"sku":"125800-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125800-01-keyphasor-i-o-module-g0u1ored1qb_f6776ea8-729d-4501-8bed-87071ff51568.jpg?v=1765449463","url":"https:\/\/www.plcprotech.com\/uz\/products\/bently-nevada-125800-01-3500-25-keyphasor-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}