{"product_id":"bently-nevada-125840-01-3500-15-high-voltage-ac-power-input-module","title":"Bently Nevada 125840-01 3500\/15 High Voltage AC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cb\u003e125840-01\u003c\/b\u003e is a High Voltage AC Power Input Module (PIM) manufactured by \u003cb\u003eBently Nevada\u003c\/b\u003e for the 3500\/15 Power Supply system within the 3500 Series Machinery Protection System. Installed in a special half-height slot directly behind the associated AC power supply module at the rear of the rack, the \u003cb\u003e125840-01\u003c\/b\u003e accepts high-voltage AC utility power and routes it to the primary or backup AC power supply module. The module accommodates an input range of 175 to 264 Vac rms (247 to 373 Vac pk) at 47 to 63 Hz, drawing up to 2.3 A rms maximum under full rack load conditions. It includes internal fuse protection against over-voltage line conditions and operates seamlessly in single or dual-redundant power supply configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eHalf-height rear Power Input Module designed for the 3500\/15 Power Supply system\u003c\/li\u003e\n  \u003cli\u003eAccepts high voltage AC power input ranging from 175 to 264 Vac rms\u003c\/li\u003e\n  \u003cli\u003eSupports full rack power operation without requiring a minimum rack load\u003c\/li\u003e\n  \u003cli\u003eOperates in both primary (lower slot) and backup (upper slot) redundant power supply configurations\u003c\/li\u003e\n  \u003cli\u003eFeatures built-in over-voltage protection utilizing a replaceable line fuse\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003ePower distribution for 3500 Series Machinery Protection System racks\u003c\/li\u003e\n  \u003cli\u003eContinuous vibration and condition monitoring systems in industrial environments\u003c\/li\u003e\n  \u003cli\u003eHigh-voltage AC utility powered machinery protection installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Part Number\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003e3500\/15-AXX-BXX-CXX\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eA: Power Supply Type (Top Slot)\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage ac (85 to 132 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage ac (175 to 264 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage dc (88 to 140 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage dc (20 to 30 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eB: Power Supply Type (Bottom Slot)\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo supply (use when only one supply is required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage ac (85 to 132 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage ac (175 to 264 Vac rms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage dc (88 to 140 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage dc (20 to 30 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eC: Agency Approval Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eCSA\/NRTL\/C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eATEX\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eSpares \u0026amp; Related Parts\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e125840-01\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage ac Power Input Module (PIM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e127610-01\u003c\/td\u003e\n      \u003ctd\u003eac Power Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e125840-02\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage ac Power Input Module (PIM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e129486-01\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage dc Power Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e129478-01\u003c\/td\u003e\n      \u003ctd\u003eHigh Voltage dc Power Input Module (PIM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e133292-01\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage dc Power Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e129767-01\u003c\/td\u003e\n      \u003ctd\u003eLow Voltage dc Power Input Module (PIM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e01720025\u003c\/td\u003e\n      \u003ctd\u003eReplacement Fuse (for both ac PIMs and High Voltage dc PIMs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e01720045\u003c\/td\u003e\n      \u003ctd\u003ePower Supply Operations and Maintenance Manual\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eNominal Input Voltage\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 Vac nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eInput Voltage Range\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e175 to 264 Vac rms (247 to 373 Vac pk)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eInput Frequency Range\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFull Rack Current Draw\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.3 A rms maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eOut of Range Protection\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnder-voltage will not harm the PIM; over-voltage causes the internal fuse to open\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMinimum Loading\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo minimum rack load required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eHumidity\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003ePIM Dimensions (H x W x D)\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003ePIM Weight\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eRack Space Requirement\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpecial half-height module located directly behind the associated power supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMount the module into the designated rear half-height slot directly behind its corresponding front-installed 3500\/15 AC power supply module.\u003c\/li\u003e\n  \u003cli\u003eWhen utilizing two power supplies for redundancy, ensure the primary supply is positioned in the lower slot and the backup supply in the upper slot.\u003c\/li\u003e\n  \u003cli\u003eEither power supply or PIM can be inserted or removed without disrupting rack operation, provided a second functional power supply is installed and active.\u003c\/li\u003e\n  \u003cli\u003eConnect high voltage AC line power within the specified 175 to 264 Vac rms operating window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eCE Mark Directives (EMC)\u003c\/b\u003e: EN 50081-2 (Radiated Emissions EN 55011 Class A, Conducted Emissions EN 55011 Class A); EN 50082-2 (Electrostatic Discharge EN 61000-4-2 Criteria B, Radiated Susceptibility ENV 50140 Criteria A, Conducted Susceptibility ENV 50141 Criteria A, Electrical Fast Transient EN 61000-4-4 Criteria B, Surge Capability EN 61000-4-5 Criteria B, Magnetic Field EN 61000-4-8 Criteria A, Power Supply Dip EN 61000-4-11 Criteria B, Radio Telephone ENV 50204 Criteria B)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eLow Voltage Directives\u003c\/b\u003e: EN 61010-1 Safety Requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eCSA\/NRTL\/C (Option 01)\u003c\/b\u003e: Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF); Certification Number CSA 150268-1002151 (LR 26744)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eCSA\/NRTL\/C (Option 02)\u003c\/b\u003e: A\/Ex nC[L] IIC, Class I, Zone 2; Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF); Certification Number CSA 1389797 (LR 26744-211)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eATEX (Option 02)\u003c\/b\u003e: II 3\/(3) G, EEx nCAL[L] IIC, T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF); Certification Number LCIE 04 ATEX 6161X\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868597099,"sku":"125840-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125840-01-high-voltage-ac-power-input-module-a1mxnejqphc_41102af6-a9b2-4d46-8806-de0b662e47f6.jpg?v=1765449548","url":"https:\/\/www.plcprotech.com\/uz\/products\/bently-nevada-125840-01-3500-15-high-voltage-ac-power-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}