{"product_id":"bently-nevada-991-06-70-02-01-thrust-transmitter","title":"Bently Nevada 991-06-70-02-01 Surish Transmitteri","description":"\u003ch3\u003eTavsif\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-06-70-02-01\u003c\/strong\u003e - bu 2 simli, aylana quvvat bilan ishlaydigan \u003cstrong\u003eItarish transmitteri\u003c\/strong\u003e bo'lib, u aylanuvchi uskunalarda axial mil pozitsiyasi yoki itarish siljishini o'lchash uchun yaqinlik probi tizimidan keladigan signallarni qayta ishlash uchun mo'ljallangan. Ushbu qurilma xom signalni umumiy maqsad harakatiga mutanosib bo'lgan standart 4 dan 20 mA analog chiqishga aylantiradi. U alohida monitor shkafi talab qilmasdan, PLC yoki DCS kabi boshqaruv tizimlari bilan to'g'ridan-to'g'ri interfeys qilish uchun ishlab chiqilgan bo'lib, muhim uskunalarni himoya qilish uchun tejamkor yechim taqdim etadi. Qurilma sanoat muhitida aniq, yuqori tezlikdagi axial siljishni monitoring qilish uchun mos yaqinlik transduserlari bilan integratsiyalash uchun optimallashtirilgan.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAylana quvvat bilan ishlaydigan 2 simli dizayn maydon simlarini soddalashtiradi va o'rnatish xarajatlarini kamaytiradi.\u003c\/li\u003e\n\u003cli\u003eTo'g'ridan-to'g'ri 4 dan 20 mA analog chiqish PLC va DCS tizimlari bilan muammosiz interfeys qiladi.\u003c\/li\u003e\n\u003cli\u003eKontakt bo'lmagan eddy tok o'lchash printsipi uzoq muddatli ishonchlilikni ta'minlaydi.\u003c\/li\u003e\n\u003cli\u003eMaxsus BNC ulagichi diagnostika uchun bufersiz xom kuchlanish signalini taqdim etadi.\u003c\/li\u003e\n\u003cli\u003eIxcham DIN relsiga o'rnatiladigan dizayn boshqaruv shkafi joyini tejaydi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo'llanmalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarkazdan qochiruvchi kompressorlar axial itarish siljishini monitoring qilish\u003c\/li\u003e\n\u003cli\u003eBug' va gaz turbina rotorining o'qi axial pozitsiyasini kuzatish\u003c\/li\u003e\n\u003cli\u003eKazan oziqlantirish nasosining milini monitoring qilish\u003c\/li\u003e\n\u003cli\u003eSanoat reduktorining itarish yostig'i aşınishini baholash\u003c\/li\u003e\n\u003cli\u003eYuqori tezlikdagi ventilyator va blovyer milining pozitsiyasini aniqlash\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuyurtma ma'lumotlari\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e991: Itarish transmitteri\u003c\/li\u003e\n\u003cli\u003e06: 3300 XL 8 mm yaqinlik probi 1.0 mm chiziqli diapazon bilan mosligi\u003c\/li\u003e\n\u003cli\u003e70: 7.0 metr tizim uzunligi varianti\u003c\/li\u003e\n\u003cli\u003e02: 35 mm DIN relsiga o'rnatish varianti\u003c\/li\u003e\n\u003cli\u003e01: Ko'p tasdiqlash varianti (ATEX, IECEx, CSA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTexnik spetsifikatsiyalar\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eTexnik xususiyatlar\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eIshlab chiqaruvchi\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eIshlab chiqarilgan mamlakat\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAmerika Qo'shma Shtatlari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMahsulot turi\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eItarish transmitteri\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eChiqish signali\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4 dan 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eQuvvat talablari\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e17 dan 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eO'lchov koeffitsienti\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e4 mA\/mm (yoki ekvivalent mil asosidagi kalibrlash)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eIshlash harorati oralig'i\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e-35 dan +85 Selsiygacha\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eSaqlash harorati oralig'i\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-40 dan +100 Selsiygacha\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eKorpus materiali\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eSink qoplangan po'lat yoki maxsus polimer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eO'rnatish turi\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e35 mm DIN relsiga o'rnatish turi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eTaxminiy vazn\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eO'lchamlar\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e25.4 mm kenglik x 112 mm balandlik x 99 mm chuqurlik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUlanishlar \/ interfeyslar\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eUlagich pinlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunktsiya\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e+4-20mA \/ +VTX\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMusbat quvvat \/ aylana oqimi kirishi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-4-20mA \/ -VTX\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eManfiy quvvat \/ aylana oqimi qaytishi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePROX\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eYaqinlik probi signal kirish terminali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eUmumiy referens terminali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSHLD\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eShild \/ Yerga ulash terminali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBNC ulagichi\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eBuferli xom kuchlanish chiqishi (10.2 mV\/mikrometr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eO'rnatish bo'yicha ko'rsatmalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN relsiga o'rnatish:\u003c\/strong\u003e Transmitterni chang va suv kirishidan himoya qilish uchun IP54 yoki undan yuqori darajadagi qopqoq ichida, yerga ulangan 35 mm DIN relsiga mahkamlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQalqon tugashi:\u003c\/strong\u003e Transduser kabel qalqonlarini uzatuvchi SHLD terminaliga ulang va boshqaruv halqasi qalqonini faqat DCS\/PLC tomonida yerga ulang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProb bo‘shlig‘ini sozlash:\u003c\/strong\u003e 4 dan 20 mA nol nuqtasini kalibrlashdan oldin, tegishli yaqinlik probini mexanik jihatdan uning fizik o‘rta diapazon voltajiga sozlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabel yo‘nalishi:\u003c\/strong\u003e Kirish yaqinlik prob kabellarini va chiqish tok halqasi kabellarini yuqori kuchlanishli AC liniyalardan ajrating, magnit shovqinining o‘tishini oldini olish uchun.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuvvat ta’minoti polariteti:\u003c\/strong\u003e Ichki himoya diodlariga zarar yetmasligi uchun quvvatni yoqishdan oldin halqa voltajining polaritetini tekshiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMoslik va sertifikatlash\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTez-tez so‘raladigan savollar\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUshbu uzatuvchining asosiy vazifasi nima?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eU xom yaqinlik prob signallarini shaftning o‘q bo‘ylab siljishini kuzatish uchun proporsional 4 dan 20 mA tok halqasiga aylantiradi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUshbu qurilma alohida shkaf asosidagi monitoring tizimini talab qiladimi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYo‘q, u ma’lumotlarni to‘g‘ridan-to‘g‘ri PLC yoki DCS ga yuborish uchun mo‘ljallangan, maxsus shkaf monitorlariga ehtiyoj yo‘q.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMuhandislar ushbu qurilmadan xom dinamik tebranish ma’lumotlarini qanday yig‘adilar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOld paneldagi BNC rozetkasi standart portativ ma’lumot yig‘uvchilar yordamida shartlanmagan dinamik signalga mahalliy kirishni ta’minlaydi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQurilmani to‘g‘ri quvvat bilan ta’minlash uchun qanday halqa voltaji talab qilinadi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUzatuvchi 17 dan 30 VDC gacha bo‘lgan standart halqa quvvat voltaj oralig‘ida samarali ishlaydi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUshbu qurilma to‘g‘ridan-to‘g‘ri mashina korpusiga o‘rnatilishi mumkinmi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eU yuqori harorat ta’sirini va ortiqcha tebranishni kamaytirish uchun himoyalangan maydon tugun qutisiga yoki boshqaruv qopqog‘iga o‘rnatilishi kerak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAgar simlash paytida halqa polariteti tasodifan teskari bo‘lsa, nima bo‘ladi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIchki teskari polaritetdan himoya komponentlarning shikastlanishini oldini oladi, ammo to‘g‘rilanmaguncha qurilma tok signalini chiqarmaydi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDastlabki o‘rnatishda kalibrlash kerakmi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUskuna zavodda maxsus tizim uzunliklari va prob turlariga moslab kalibrlangan bo‘lib, o‘rnatishda faqat bo‘shliqni tekshirish talab etiladi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5 metrli prob tizimi 7.0 metrli uzatuvchi opsiyasiga ulangan bo‘lishi mumkinmi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYo‘q, elektr tizimi uzunligi variantlarini noto‘g‘ri moslashtirish sezilarli chiziqlilik xatolariga olib keladi va chiqish aniqligini buzadi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKo‘p tasdiqlash qo‘shimcha opsiyasining ahamiyati nima?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eU ATEX, IECEx va CSA ko‘rsatmalariga muvofiq, to‘siqlar bilan o‘rnatilganda, maxsus xavfli hududlarda o‘rnatish uchun uzatuvchini sertifikatlaydi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO‘zgaruvchan chastotali drayverlardan keladigan elektr shovqini qanday boshqarish kerak?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBarcha qalqonlarning butunligini, mashina yeridan to‘g‘ri izolyatsiya qilinganligini va faqat to‘g‘ri asbobning umumiy relsiga ulanganligini ta’minlang.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733953387,"sku":"991-06-70-02-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-70-02-01-thrust-transmitter-fb4rym3o53w_88ad2eb0-7ac2-4e76-be22-962babfff94a.jpg?v=1765446737","url":"https:\/\/www.plcprotech.com\/uz\/products\/bently-nevada-991-06-70-02-01-thrust-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}