{"product_id":"delta-ah08ad-5b-ah500-series-8-channel-analog-input-module","title":"DELTA AH08AD-5B AH500 seriyali 8 kanalli analog kirish moduli","description":"\u003ch3\u003eUmumiy ko‘rinish va muhandislik qiymati\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH08AD-5B (AH08AD5B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelta AH500 seriyali PLC platformasi uchun ishlab chiqilgan yuqori zichlikdagi analog kirish interfeysi vazifasini bajaradi. Oqova suvlarni tozalash, neft-kimyo mahsulotlarini qayta ishlash va elektr energiyasini avtomatlashtirilgan taqsimlash kabi sohalardagi murakkab jarayonlarni boshqarish vazifalarini bajarish uchun yaratilgan ushbu modul og‘ir elektr sharoitlarida aniq ma’lumot yig‘ishni kafolatlaydi. Sakkizta yuqori aniqlikdagi kanalni ixcham korpusga birlashtirish orqali u shkaf uchun zarur joyni kamaytiradi va shovqinga nisbatan yuqori chidamlilikni ta’minlaydi. Issiq almashtirish funksiyasi muntazam texnik xizmat ko‘rsatish vaqtida ishlab chiqarish liniyasining to‘xtab qolishini bartaraf etadi, bu esa tizim integratorlariga markaziy protsessorni to‘xtatmasdan yoki muhim ketma-ket boshqaruv operatsiyalarini uzmasdan modullarni almashtirish imkonini beradi.\u003c\/p\u003e\n\u003ch3\u003eTizim konfiguratsiyasi va arxitektura dizayni\u003c\/h3\u003e\n\u003cp\u003eUshbu modulning apparat arxitekturasi dala tomonidagi konturlarni sezgir ichki mantiqiy sxemalardan ajratish uchun izolyatsiyalangan signal dizaynidan foydalanadi. Ushbu konfiguratsiya sanoat muhitida keng tarqalgan yer konturlari va yuqori kuchlanishli o‘tkinchi jarayonlarni samarali to‘sadi. Signalni raqamlashtirish yuqori unumdorlikka ega 16 bitli ketma-ket yaqinlashish registri (SAR) analog-raqamli o‘zgartirgichi orqali boshqariladi va kuchlanish hamda tok konturlari uchun nozik aniqlikni ta’minlaydi.\u003c\/p\u003e\n\u003cp\u003eO‘rnatilgan uzilish funksiyasi kanal chegarasi buzilganda, odatiy dastur skanerlash vaqtlarini chetlab o‘tib, protsessdagi muhim og‘ishlarga protsessorning bir zumda javob berishiga imkon beradi. Diagnostika imkoniyatlari tizim holatini, sim uzilishlarini va diapazondan tashqari kirishlarni doimiy kuzatib boradigan, aniqlangan nosozliklar haqida orqa panel orqali boshqaruv kontrolleriga real vaqt rejimida xabar beradigan integratsiyalangan apparat registrlari orqali amalga oshiriladi.\u003c\/p\u003e\n\u003ch3\u003eUskuna xususiyatlari\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTexnik xususiyatlar tafsilotlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAH08AD-5B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrend\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKelib chiqishi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTayvan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKirishlar soni\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 ta kanal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal diapazonlari (kuchlanish)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 dan 1 V gacha, 1 dan 5 V gacha, -5 dan +5 V gacha, 0 dan 10 V gacha, -10 dan +10 V gacha\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal diapazonlari (tok)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 dan 20 mA gacha, 4 dan 20 mA gacha, -20 dan +20 mA gacha\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUskuna aniqligi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKonversiya tezligi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHar bir kanal uchun 150 mikrosekund\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAsosiy xato (25 °C da)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKuchlanish rejimi: +\/-0,1%, tok rejimi: +\/-0,1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAsosiy xato (to‘liq diapazon)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKuchlanish rejimi: +\/-0,45%, tok rejimi: +\/-0,2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChiziqlilik xatosi (25 °C da)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKuchlanish rejimi: +\/-0,07%, tok rejimi: +\/-0,05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eQuvvat sarfi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,9 W (ichki orqa panel quvvati)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIzolyatsiya usuli\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRaqamli va analog sxemalar o‘rtasidagi optik izolyatsiya\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal ulanishi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJIS olinadigan terminal bloki\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eO‘lchamlar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm x 35 mm x 103 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOg‘irlik\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg (jo‘natish og‘irligi: himoya qadoqlari sababli 2.0 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIshlash harorati\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 dan 60 °C gacha\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTexnik savollar va muammolarni bartaraf etish\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModul kuchlanish va tok kirishlarining kombinatsiyasini bir vaqtning o‘zida qanday boshqaradi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUskuna o‘zining 8 kanalida aralash signal taqsimotini qo‘llab-quvvatlaydi. Konfiguratsiya PLC dasturlash dasturi orqali boshqariladi; har bir kanal dala sensorining elektr chiqish profiliga mos keladigan tarzda mustaqil ravishda tayinlanishi mumkin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModul holati LED indikatori xatoni ko‘rsatsa, qanday choralar ko‘rish kerak?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIchki diagnostika registrlarini dasturlash yordam dasturi orqali tekshiring. Doimiy qizil xato indikatori odatda tashqi quvvat manbai nosozligini, 4-20 mA tok konturidagi uzilishni yoki kirish signalining sozlangan maksimal chegaradan oshib ketganini bildiradi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJarayon ishlayotgan paytda issiq almashtirish funksiyasidan foydalanish xavfsizmi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHa. Orqa plata interfeysi ishga tushish toklarini boshqarish uchun bosqichma-bosqich uzunlikdagi pinlar bilan ishlab chiqilgan. Ichki mantiqni shikastlash yoki qo‘shni kirish-chiqish modullarining ishini buzish xavfisiz modulni stend quvvatlangan holatda chiqarish yoki o‘rnatish mumkin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eJoyida ishga tushirish va xavfsizlik protokollari\u003c\/h3\u003e\n\u003ch3\u003eEkranlash va yerga ulash standartlari\u003c\/h3\u003e\n\u003cp\u003eElektromagnit xalaqitlarni kamaytirish uchun barcha analog asbob kabellarida umumiy o‘rama ekranli o‘ralgan juft o‘tkazgichlardan foydalanish kerak. Ekranni faqat boshqaruv shkafining yerga ulash shinasiga past impedansli yerga ulash qisqichi yordamida ulang. Ekranning dala asbobi tomonini ulanmagan holda qoldirish yer konturlarining hosil bo‘lishining oldini oladi, aks holda ular 16 bitli signal konversiyasi aniqligini buzishi mumkin.\u003c\/p\u003e\n\u003ch3\u003eTerminal bloki momenti va simlarni ulash\u003c\/h3\u003e\n\u003cp\u003eJIS olinadigan terminal blokiga ulashda, adashgan sim tolalari qisqa tutashuvga sabab bo‘lishi xavfini bartaraf etish uchun izolyatsiyalangan gilzali klemma uchlaridan foydalaning. Barcha terminal vintlarini ko‘pi bilan 0.5 Nm moment bilan torting. Induktiv shovqin ulanishining oldini olish uchun past kuchlanishli analog signal liniyalarini yuqori kuchlanishli o‘zgaruvchan tok dvigatel yuritmasi kabellari bilan bir xil quvur yoki kabel kanali ichidan o‘tkazmang.\u003c\/p\u003e\n\u003ch3\u003eIssiqlikni boshqarish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003cp\u003eTabiiy konvektiv havo oqimini ta’minlash uchun modul stendi ustida va ostida kamida 50 mm bo‘sh joy qoldiring. Atrof-muhit harorati 60 °C yuqori chegaraga yaqin bo‘lgan yopiq boshqaruv panellarida ichki analog tayanch signallarining termik siljishining oldini olish uchun majburiy shamollatish yoki faol konditsioner tizimi o‘rnatilishi shart.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102411972971,"sku":"AH08AD-5B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AH08AD-5B-0g5kvjqqwsl.png?v=1776137196","url":"https:\/\/www.plcprotech.com\/uz\/products\/delta-ah08ad-5b-ah500-series-8-channel-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}