{"product_id":"ge-ex2000-531x171tmaafg2-terminal-board-relay-card","title":"GE EX2000 531X171TMAAFG2 Terminal taxtasi rele kartasi","description":"\u003ch3\u003eMahsulot sharhi\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e531X171TMAAFG2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral Electric tomonidan \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEX2000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eraqamli eksitatsiya va haydash ekotizimi uchun ishlab chiqilgan maxsus yuqori ishonchlilikdagi Terminal taxtasi rele kartasi hisoblanadi. Signal I\/O yo‘naltirish va murakkab interfeys ishlov berish uchun markaziy bog‘lovchi sifatida xizmat qiladi, bu sanoat taxtasi maxsus ko‘p o‘tkazgichli lenta kabellari orqali asosiy haydash mantiq kartasiga to‘g‘ridan-to‘g‘ri ulanadi. Chuquroq kon qazib olish korxonalari, issiqlik elektr stansiyalari va gaz siqish infratuzilmalari kabi yuqori talabli sanoat sohalari ushbu modulga raqamli boshqaruv halqalarini maydon tomonidagi aktuator toklaridan xavfsiz ajratish uchun tayanadi. Toza potentsialsiz fikrsiz aloqa o‘rnatish orqali karta erta nosozliklarni aniqlash, yuqori darajadagi boshqaruv kompyuter tizimlarini induktiv o‘q otishlardan himoya qilish, maydon qurilmasi signalizatsiyasini tezkor ta’minlash va qimmatbaho zavod to‘xtash vaqtini kamaytirishni kafolatlaydi.\u003c\/p\u003e\n\u003ch3\u003eElektr sxemasi topografiyasi va interfeys protokollari\u003c\/h3\u003e\n\u003cp\u003eIchki apparat konfiguratsiyasi\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e531X171TMAAFG2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBoshqaruv taxtasi ishonchli terminal guruhlanishi, signal izolyatsiyasi va avlodlararo modul almashtirishga e’tibor qaratadi.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePotentsialsiz kontaktlar:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuvvat uzilishi ogohlantirishlari, umumiy tizim signalizatsiyasi, batareya past parametrlari va faol bypass holati sikllari kabi muhim uskunalar yangilanishlarini xaritalash uchun mo‘ljallangan to‘rt yuqori ishonchlilikdagi quruq almashtirish rele yo‘llari bilan jihozlangan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIkki tomonlama seriyali integratsiya interfeysi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMahalliy kompyuter tizimlari va zaxira quvvat tizimlari o‘rtasida ilg‘or ishlov berish aloqalarini ta’minlash uchun USB ulagichi va og‘ir yukli 9-pol Sub-D ulagich portini o‘z ichiga oladi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTo‘g‘ridan-to‘g‘ri almashtirish:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOrqaga mos keluvchi iz xaritasi bilan ishlab chiqilgan, bu maxsus apparat versiyasi bir nechta eski yoki shikastlangan GE interfeys kartalarini asosiy tizim funksional parametrlarini yo‘qotmasdan almashtirish imkonini beradi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePast quvvatli faollashtirish tarmog‘i:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFaqat 8 dan 18 V gacha ishchi tok talab qiladi, barcha quruq kontaktli relelar bir vaqtning o‘zida yopiq holatga o‘tkazilganda maksimal 2 W tok sarflaydi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIshlash ma’lumotlari va tizim indekslari\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTizim parametri\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMuhandislik spetsifikatsiyasi\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel nomlanishi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e531X171TMAAFG2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrend ishlab chiqaruvchisi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoshqaruv seriyasi liniyasi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEX2000 eksitatsiya \/ haydash platformasi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModul identifikatsiyasi sinfi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal taxtasi rele kartasi \/ I\/O interfeysi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIshlash quvvat kirishi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 dan 18 VDC oralig‘i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksimal modul quvvat sarfi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 W maksimal (barcha rele kanallari yopiq holatda)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal kirish faollashtirish darajasi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,4 VDC da 1,35 mA minimal faol holat chegarasi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChiqish turi tartibi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElektromexanik rele kontaktlari vintli terminal bloklari orqali\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksimal kontakt kuchlanish reytingi\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 VDC yoki 42 VAC RMS limiti\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaksimal uzluksiz tok\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,25 A maksimal (50 VA maksimal induktiv yuk limiti)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAtrof-muhit harorati chegaralari\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 dan +40 daraja Selsiygacha ish harorati oralig‘i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSaqlash harorati chegaralari\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 dan +60 daraja S maksimal issiqlik sig'imi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIshlab chiqarilgan mamlakat\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmerika Qo'shma Shtatlari (AQSh)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunktsional operatsiyalar va qayta jihozlash bo'yicha tez-tez so'raladigan savollar\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e531X171TMAAFG2 eski avlod terminal platalarini maydon simlarini o'zgartirmasdan to'g'ridan-to'g'ri almashtira oladimi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYo'q, to'g'ridan-to'g'ri almashtirish kichik maydon chiziqlari yangilanishlarini talab qiladi, bu GE texnik qo'llanmalarida ko'rsatilgan. Masalan, agar mavjud shikastlangan karta ACOM tugunidagi 24-terminalga simni xaritalasa, bu maydon simi yangi plata yig'ilmasidagi AN1 terminaliga ko'chirilishi kerak. Bundan tashqari, ba'zi terminal yo'nalishlari simlarni eski 4TB terminal blok guruhidan yangi 3TB blok guruhiga ko'chirishni talab qiladi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAgar tizim sinovida signal kirishi 2,4 VDC dan pastga tushsa, to'g'ri protsedura nima?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2,4 VDC dan past kirish kuchlanishi yoki 1,35 mA dan past kirish toki on-plata optokoplerlari yoki rele bobinlarini ishonchli ishga tushira olmaydi. Texniklar signal manbai zanjirini tekshirib, yuqori qarshilikli terminal ulanishlarini tozalashi yoki uzoq maydonli kabel yo'llaridagi kuchlanish tushishini tuzatishi kerak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRele chiqishlari tomonidan boshqariladigan maksimal quvvat reytingini belgilovchi muhim o'zgaruvchilar nimalar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegratsiyalangan almashtirish rele kontaktlari maksimal 60 VDC yoki 42 VAC RMS gacha past kuchlanishli signal uchun mo'ljallangan. Doimiy tok limiti 1,25 A, agar umumiy reaktiv quvvat 50 VA dan oshmasa. Ushbu qiymatlarni oshirish kontakt nuqtalarini yoki iz zanjirlarini darhol payvandlab qo'yishi mumkin.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMuhandislik va o'rnatish qo'llanmasi\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElektrostatik yerga ulash va komponentlarni himoya qilish:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e531X171TMAAFG2 statik elektrga sezgir nozik qattiq holatli komponentlarni o'z ichiga oladi. Modulni o'rnatish paytida anti-statik himoya sumkasida yopiq holda saqlang. Maydon xodimlari platalarni ushlashdan oldin korpusning bo'yalmagan qismiga yerga ulangan statik bilak tasmasini taqishlari va PCBni faqat tashqi shisha tolali chekkalaridan ushlashlari kerak, shunda teri yog'lari va statik zaryadlar komponentlar yoki ochiq payvand joylariga tegmaydi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminalarni qayta jihozlash va simlarni ko'chirish qoidalari:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eZamonaviy 531X171TMAAFG2 versiyasiga eski plata variantini almashtirganda, terminal belgilanishlarini asl chizmalar bo'yicha tekshiring. Eski 24-terminaldan chiziqlarni moslashtirganda, ACOM terminalidan AN1 pozitsiyasiga o'tkazing. To'g'ri mantiqiy signalni saqlash uchun eski 4TB headeriga ulangan sim guruhlarini to'g'ridan-to'g'ri 3TB terminal blok yig'ilmasiga ehtiyotkorlik bilan ko'chiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal moment chegaralari va kiritish nazorati:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBarcha maydon chiziqlarini 7 mm orqaga torting va ularni og'ir yuk uchun mo'ljallangan vint bloklariga mahkamlang. Barcha terminalarni izolyatsiyalangan sanoat tornavida yordamida maksimal 0,4 N-m (3,5 dyuym-funt) moment bilan mahkamlang. Haddan tashqari moment terminal bloki va plata qatlami orasidagi ichki izlarni sindirishi mumkin, kam moment esa sanoat uskunalarining kuchli tebranishi ostida ochiq zanjirlarga olib keladi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695407985003,"sku":"531X171TMAAFG2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-531x171tmaafg2-terminal-board-relay-card-a3zik5vitgg_6c17de0f-7eda-43cc-93d3-6d4bc73662e2.jpg?v=1766134955","url":"https:\/\/www.plcprotech.com\/uz\/products\/ge-ex2000-531x171tmaafg2-terminal-board-relay-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}