{"product_id":"ge-fanuc-ic600pm541-series-six-24-vdc-input-cpu-dpu-power-supply-module","title":"GE Fanuc IC600PM541 Series Six 24 VDC kirishli CPU\/DPU quvvat ta’minoti moduli","description":"\u003ch3\u003eTavsif\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGE Fanuc IC600PM541\u003c\/strong\u003e — \u003cstrong\u003eGE Fanuc Series Six\u003c\/strong\u003e dasturlanadigan mantiqiy boshqaruv tizimi uchun ishlab chiqilgan, shkafga o‘rnatiladigan \u003cstrong\u003e24 VDC kirishli CPU\/DPU quvvat ta’minoti moduli\u003c\/strong\u003e. \u003cstrong\u003e20–32 VDC\u003c\/strong\u003e diapazonidagi kirish manbasidan ishlaydigan ushbu quvvat ta’minoti moduli Markaziy protsessor qurilmasi (CPU) yoki Ma’lumotlarni qayta ishlash qurilmasini (DPU) qo‘llab-quvvatlash uchun rostlangan \u003cstrong\u003e+5 VDC\u003c\/strong\u003e, \u003cstrong\u003e+12 VDC\u003c\/strong\u003e va \u003cstrong\u003e-12 VDC\u003c\/strong\u003e kuchlanishlarini to‘g‘ridan-to‘g‘ri shkafning orqa paneliga uzatadi. U CPU\/DPU shkafining eng o‘ng tomoniga o‘rnatiladi va sanoat boshqaruv tizimlarida standart \u003cstrong\u003e115\/230 VAC\u003c\/strong\u003e kirishli quvvat ta’minoti modullariga to‘g‘ridan-to‘g‘ri doimiy tok muqobili bo‘lib xizmat qiladi.\u003c\/p\u003e\n\u003cp\u003eKommutatsion topologiya asosida qurilgan \u003cstrong\u003eIC600PM541\u003c\/strong\u003e muayyan yuklama uchun kirish quvvati sarfini deyarli doimiy saqlaydi va ichki sxemalarni kirishdagi doimiy tok qutblari teskari ulanishidan himoya qiladi. Tizim quvvatini o‘zgartirishdan tashqari, qurilmada tizim nosozliklari vaqtida tashqi foydalanuvchi indikatorlari yoki ogohlantirgichlariga ulanadigan o‘rnatilgan elektromexanik signalizatsiya relesi kontaktlari mavjud. Shuningdek, protsessor shkafidagi CMOS xotirasini saqlab qolish uchun ixtiyoriy yordamchi batareyani qo‘llab-quvvatlaydigan integratsiyalangan kuchlanish regulyatori ham mavjud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGE Fanuc IC600PM541A\u003c\/strong\u003e old panelida mahalliy tizim boshqaruvi va xotira xavfsizligini ta’minlovchi ikkita kalitli tumbler hamda holat indikatorlari mavjud. Rejim tanlash tumbleri operatorlarga protsessorni \u003cstrong\u003eRUN\u003c\/strong\u003e va \u003cstrong\u003eSTOP\u003c\/strong\u003e rejimlari o‘rtasida almashtirish imkonini beradi, maxsus xotira himoyasi tumbleri esa protsessor xotirasini \u003cstrong\u003eREAD ONLY\u003c\/strong\u003e qulflash holatiga o‘tkazadi. Har ikkala kalit bitta umumiy kalit bilan boshqariladi. Old panelga o‘rnatilgan \u003cstrong\u003ePOWER\u003c\/strong\u003e LED indikatori real vaqt rejimida diagnostika holatini ko‘rsatadi va uchala doimiy tok chiqish shinalari ham standart kuchlanish tolerantliklari doirasida ishlaganda yonib turadi.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlari\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeng doimiy tok kirish mosligi:\u003c\/strong\u003e \u003cstrong\u003e20–32 VDC\u003c\/strong\u003e (\u003cstrong\u003emaksimal 180 VA\u003c\/strong\u003e) manba kuchlanishini qabul qiladi va tizimni \u003cstrong\u003e24 VDC\u003c\/strong\u003e quvvat tarmoqlarida qo‘llash imkoniyatini kengaytiradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUchta rostlangan chiqish shinasi:\u003c\/strong\u003e Asosiy doimiy tok kirishini rostlangan \u003cstrong\u003e+5 VDC\u003c\/strong\u003e (\u003cstrong\u003e16,5 A\u003c\/strong\u003e), \u003cstrong\u003e+12 VDC\u003c\/strong\u003e (\u003cstrong\u003e1,5 A\u003c\/strong\u003e) va \u003cstrong\u003e-12 VDC\u003c\/strong\u003e (\u003cstrong\u003e1,0 A\u003c\/strong\u003e) orqa panel quvvatiga aylantiradi; umumiy chiqish quvvati \u003cstrong\u003e90 Vatt\u003c\/strong\u003edan kam.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIkki xil shkafga moslashuvchanlik:\u003c\/strong\u003e \u003cstrong\u003eGE Fanuc Series Six\u003c\/strong\u003e platformasidagi \u003cstrong\u003eCPU\u003c\/strong\u003e va \u003cstrong\u003eDPU\u003c\/strong\u003e shkaflariga to‘g‘ridan-to‘g‘ri o‘rnatish uchun mo‘ljallangan, bu ehtiyot qismlar zaxirasini boshqarishni soddalashtiradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegratsiyalangan signalizatsiya kontaktlari:\u003c\/strong\u003e Nosozlik holatlarida tashqi signalizatsiya indikatorlari yoki boshqaruv qurilmalarini ishga tushirish uchun elektromexanik rele kontaktlarini (\u003cstrong\u003e1 NO\u003c\/strong\u003e, \u003cstrong\u003e1 NC\u003c\/strong\u003e, \u003cstrong\u003e2 NO\u003c\/strong\u003e, \u003cstrong\u003e2 NC\u003c\/strong\u003e) taqdim etadi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYordamchi batareya regulyatori:\u003c\/strong\u003e Protsessor shkafidagi CMOS xotirasini zaxiralash uchun tashqi batareya ulanishini (\u003cstrong\u003e8–28 VDC\u003c\/strong\u003e) qo‘llab-quvvatlaydigan ichki kuchlanish regulyatoriga ega.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOld paneldagi integratsiyalangan kalitli boshqaruvlar:\u003c\/strong\u003e CPU rejimini (\u003cstrong\u003eRUN\/STOP\u003c\/strong\u003e) boshqarish va xotira tarkibini \u003cstrong\u003eREAD ONLY\u003c\/strong\u003e holatida qulflash (\u003cstrong\u003eWRITE\/MEMORY PROTECT\u003c\/strong\u003e) uchun old panel tumblerlari bilan jihozlangan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeskari qutblanish va ortiqcha tokdan himoya:\u003c\/strong\u003e Doimiy tok qutblarining tasodifiy teskari ulanishidan himoyalangan va quvvat kaliti\/sug‘urta blokida joylashgan \u003cstrong\u003e8 A kechikuvchi\u003c\/strong\u003e ichki sug‘urta bilan himoyalangan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostik quvvat monitoringi:\u003c\/strong\u003e Old paneldagi \u003cstrong\u003ePOWER\u003c\/strong\u003e LED indikatori barcha chiqish kuchlanishlari (\u003cstrong\u003e+5V\u003c\/strong\u003e, \u003cstrong\u003e+12V\u003c\/strong\u003e, \u003cstrong\u003e-12V\u003c\/strong\u003e) ish tolerantliklari doirasida ekanini ko‘rsatadi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo‘llanilishi\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Six PLC CPU shkaflari:\u003c\/strong\u003e Eski avlod texnologik boshqaruv tizimlaridagi asosiy protsessor shkaflari uchun birlamchi doimiy tokni orqa panel quvvatiga aylantiradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMa’lumotlarni qayta ishlash qurilmasi (DPU) shkaflari:\u003c\/strong\u003e Kengaytirilgan \u003cstrong\u003eGE Fanuc Series Six\u003c\/strong\u003e boshqaruv arxitekturalaridagi yordamchi ma’lumotlarni qayta ishlash shkaflarini quvvatlaydi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC sanoat boshqaruv tizimlari:\u003c\/strong\u003e Elektr tarmog‘i ishonchliligi muhim bo‘lgan sanoat obyektlarida PLC qurilmalarini statsionar \u003cstrong\u003e24 VDC\u003c\/strong\u003e batareya bloklari yoki doimiy tok shinalaridan bevosita ishlatish uchun qo‘llaniladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMasofaviy signalizatsiya va ogohlantirish interfeysi:\u003c\/strong\u003e Ichki PLC tizimi nosozlik mantiqini ajratilgan rele chiqishlari orqali tashqi vizual\/ovozli obyekt ogohlantirish tizimlariga ulaydi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuyurtma ma’lumotlari\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKatalog raqami\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModul turi \/ Tavsifi\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eUL ro‘yxatga olish standarti\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC600PM541\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC kirishli CPU\/DPU quvvat ta’minoti moduli\u003c\/td\u003e\n\u003ctd\u003eUL Standard No. 508 (sanoat boshqaruv uskunalari)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTexnik xususiyatlar\u003c\/h3\u003e\n\u003ch4\u003eUmumiy\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlab chiqaruvchi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeriya\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries Six dasturlanadigan kontrollerlari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC600PM541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMahsulot turi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU\/DPU quvvat ta’minoti moduli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO‘rnatish joyi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU yoki DPU shkafining eng o‘ng tomoni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eKirish xususiyatlari\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManba kuchlanishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksimal kirish quvvati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emaks. 180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRuxsat etilgan quvvat uzilishlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 VDC liniyada kamida 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIchki himoya\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A slo-blo sug‘urta bilan himoyalangan; teskari qutblanishdan himoyalangan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eChiqish xususiyatlari\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish kuchlanishlari va toklari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC da maks. 16,5 A; +12 VDC da maks. 1,5 A; -12 VDC da maks. 1,0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmumiy chiqish quvvati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarcha chiqishlardan olinadigan umumiy quvvat 90 W dan kam bo‘lishi kerak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYordamchi batareya kirishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8–28 VDC (integratsiyalangan kuchlanish regulyatori mavjud)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSignalizatsiya kontaktlari ko‘rsatkichlari\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRele kontaktlari turlari\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAjratilgan kontaktlarning ikki to‘plami: 1-to‘plam (1 NO, 1 NC), 2-to‘plam (2 NO, 2 NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKontakt yuklamasi ko‘rsatkichi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 28 VDC da 1 A dan ko‘p bo‘lmagan tok oluvchi aktiv qarshilikli yuklama\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRele mantiqiy holati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal ishlashda quvvatlangan; signalizatsiya holatida quvvatsizlangan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eAtrof-muhit va mexanik xususiyatlar\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlash harorati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C dan 60 °C gacha (shkaf tashqarisida)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSaqlash harorati\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C dan +80 °C gacha\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNamlik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% dan 95% gacha (kondensatsiyasiz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlash balandligi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDengiz sathidan 10 000 futgacha (3 000 metr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShovqinga chidamlilik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA ICS 2-230 va ANSI C37.90A talablariga javob beradi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO‘lchamlari (K x B x Ch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,75 x 12,46 x 9,00 dyuym (70 x 317 x 229 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUlanishlar \/ Interfeyslar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKlemma \/ Interfeys\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTuri\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunksional tavsifi\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kontaktli Molex ulagichi\u003c\/td\u003e\n\u003ctd\u003eIchki quvvat ta’minoti mantiqi va signal kabelini shkafning orqa panelidan ulaydi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOS \/ NEG \/ GND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVintli klemmalar (pastki panel)\u003c\/td\u003e\n\u003ctd\u003eAsosiy 20–32 VDC quvvat ulanishlari va himoya yerga ulash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBAT + \/ BAT -\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVintli klemmalar (pastki panel)\u003c\/td\u003e\n\u003ctd\u003eXotirani zaxiralovchi yordamchi batareyani ulash kirishi (8–28 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1NO \/ 1NC \/ COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVintli klemmalar (pastki panel)\u003c\/td\u003e\n\u003ctd\u003eSignalizatsiya relesi 1-to‘plamining ajratilgan chiqish kontaktlari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2NO \/ 2NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVintli klemmalar (pastki panel)\u003c\/td\u003e\n\u003ctd\u003eSignalizatsiya relesi 2-to‘plamining ajratilgan chiqish kontaktlari\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIchki klemmalar qatori\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVintli klemmalar (yon tomon)\u003c\/td\u003e\n\u003ctd\u003eOrqa panel simlari uchun quvvat taqsimlash klemmalari (-12V, -12V COM, +5V, +5V COM, +12V, POS, NEG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKorpusni yerga ulash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShpilkali ulanish\u003c\/td\u003e\n\u003ctd\u003eKorpus yerga ulash nuqtasi (Stud-A \/ Stud-B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eO‘rnatish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eXavfsiz ajratish:\u003c\/strong\u003e CPU kalitini \u003cstrong\u003eSTOP\u003c\/strong\u003e holatiga o‘tkazing. Qurilmani jismoniy ushlashdan oldin asosiy avtomat orqali tizimdagi barcha asosiy kirish quvvatini ajrating va olib tashlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShkafdagi joylashuv:\u003c\/strong\u003e Mo‘ljallangan joy \u003cstrong\u003eSeries Six\u003c\/strong\u003e CPU yoki DPU shkafining eng o‘ng tomonida ekanini tasdiqlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKuchlanish yo‘qligini tekshirish:\u003c\/strong\u003e Himoya pastki plastik qopqog‘ini otvyortka yordamida olib tashlang va kalibrlangan multimetr bilan kirish klemmalarida doimiy tok mavjud emasligini tekshiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSim ulanishlarini hujjatlashtirish:\u003c\/strong\u003e Ajratishdan oldin mavjud yordamchi batareya, signalizatsiya relesi va doimiy tok kirish klemmalaridagi simlarning joylashuvi, raqamlari va qutblarini qayd eting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrqa panel va kabel to‘plamini ajratish:\u003c\/strong\u003e Yuqori va pastki chorak buriluvchi vintlarni bo‘shating. Yon tomondagi klemma qatoridan ichki sim ulanishlarini ehtiyotkorlik bilan ajrating va tor platadagi \u003cstrong\u003e18 kontaktli (P1) Molex ulagichini\u003c\/strong\u003e uzing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJismoniy tekislash:\u003c\/strong\u003e \u003cstrong\u003eIC600PM541A\u003c\/strong\u003e ni yo‘naltiruvchi relslar bo‘ylab shkaf karkasiga suring; ichki kabel to‘plami simlari mexanik qisilib qoladigan joylardan xoli ekaniga ishonch hosil qiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMahkamlash:\u003c\/strong\u003e Yuqori va pastki vintlarni soat strelkasi yo‘nalishida shkaf konstruksiyasiga mahkam qulflanguncha torting. Zarur bo‘lsa, sim qisqichlarini karkas shpilkalariga mahkamlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElektr ulanishini tiklash:\u003c\/strong\u003e Yon tomondagi ichki quvvat simlari va \u003cstrong\u003e18 kontaktli Molex ulagichini\u003c\/strong\u003e qayta ulang. Tashqi doimiy tok kirishini (\u003cstrong\u003ePOS\u003c\/strong\u003e, \u003cstrong\u003eNEG\u003c\/strong\u003e, \u003cstrong\u003eGND\u003c\/strong\u003e), yordamchi batareya va signalizatsiya relesi simlarini oldingi klemma blokiga ulang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQutblarni tekshirish:\u003c\/strong\u003e Quvvatni yoqishdan oldin doimiy tok ta’minoti qutblari to‘g‘ri ekanini tasdiqlang. \u003ci\u003eKirish qutblarini teskari ulash ortiqcha tok sarfiga olib keladi va ichki \u003cstrong\u003e8 A kechikuvchi\u003c\/strong\u003e sug‘urtani kuydiradi.\u003c\/i\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuvvat berish:\u003c\/strong\u003e 24 VDC kirish quvvatini ulang. Old paneldagi \u003cstrong\u003ePOWER\u003c\/strong\u003e indikatori \u003cstrong\u003eON\u003c\/strong\u003e holatiga o‘tganini tekshiring; bu +5V, +12V va -12V chiqish shinalari ish spetsifikatsiyalariga mosligini bildiradi.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTexnik xizmat va diagnostika bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePOWER indikatorini talqin qilish:\u003c\/strong\u003e Yashil \u003cstrong\u003ePOWER\u003c\/strong\u003e LED indikatori barcha uchta chiqish kuchlanishi me’yorida ishlayotganini bildiradi. Agar indikator ishlash vaqtida \u003cstrong\u003eOFF\u003c\/strong\u003e bo‘lsa, kamida bitta doimiy tok chiqish shinasi (\u003cstrong\u003e+5V\u003c\/strong\u003e, \u003cstrong\u003e+12V\u003c\/strong\u003e yoki \u003cstrong\u003e-12V\u003c\/strong\u003e) ish tolerantligidan pastlagan yoki asosiy doimiy tok kirish kuchlanishi uzilgan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSug‘urtani almashtirish:\u003c\/strong\u003e Modul ishga tushmasa va kirish qutblari teskari ulangan yoki ortiqcha tok holati yuz bergan bo‘lsa, asosiy quvvat kaliti yaqinida joylashgan \u003cstrong\u003e8 A kechikuvchi\u003c\/strong\u003e sug‘urtani tekshiring. Faqat ayni ko‘rsatkichdagi ekvivalent kechikuvchi sug‘urta bilan almashtiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalizatsiya kontaktlari mantiqiy holati:\u003c\/strong\u003e Normal, nosozliksiz ishlash vaqtida ichki signalizatsiya relesi \u003cstrong\u003equvvatlangan\u003c\/strong\u003e holatda bo‘ladi. Signalizatsiya holatida yoki modul quvvati to‘liq yo‘qolganda relelar \u003cstrong\u003equvvatsizlanadi\u003c\/strong\u003e, natijada \u003cstrong\u003e1NO \/ 2NO\u003c\/strong\u003e kontaktlari ochiladi va \u003cstrong\u003e1NC \/ 2NC\u003c\/strong\u003e kontaktlari yopiladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatareyani ajratish bo‘yicha ehtiyot chorasi:\u003c\/strong\u003e Agar CMOS xotirasini zaxiralovchi yordamchi batareya \u003cstrong\u003eBAT + \/ BAT -\u003c\/strong\u003e klemmalariga ulangan bo‘lsa, batareyaning qisqa tutashuviga yo‘l qo‘ymaslik uchun ulash zanjiri tizimning qolgan qismidan ajratilganini ta’minlang.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMuvofiqlik va sertifikatlar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL standarti:\u003c\/strong\u003e Underwriters Laboratories Inc. tomonidan \u003cstrong\u003eUL Standard No. 508\u003c\/strong\u003e (sanoat boshqaruv uskunalari, elektron quvvatni o‘zgartirish uskunalari bo‘limi) bo‘yicha ro‘yxatga olingan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShovqin standartlari:\u003c\/strong\u003e \u003cstrong\u003eNEMA ICS 2-230\u003c\/strong\u003e va \u003cstrong\u003eANSI C37.90A\u003c\/strong\u003e shovqinga chidamlilik talablariga muvofiqligi baholangan.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770268901739,"sku":"IC600PM541","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC600PM541_1200x1200_9cfed6c4-241d-4fa6-9a89-fc1074dd6fa2.jpg?v=1788267009","url":"https:\/\/www.plcprotech.com\/uz\/products\/ge-fanuc-ic600pm541-series-six-24-vdc-input-cpu-dpu-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}