{"product_id":"ge-fanuc-ic695spf002-rx3i-small-form-factor-pluggable-transceiver-module","title":"GE Fanuc IC695SPF002 RX3i kichik form-faktorli plagin transiver moduli","description":"\u003ch3\u003eTavsif\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIC695SPF002\u003c\/strong\u003e PACSystems RX3i avtomatlashtirish platformasi uchun ishlab chiqilgan sanoat Small Form-factor Pluggable (SFP) optik transiver modulidir. Ushbu optik tarmoq komponenti RX3i PROFINET Scanner (\u003cstrong\u003eIC695PNS001\u003c\/strong\u003e) va Advanced PROFINET Scanner (\u003cstrong\u003eIC695PNS101\u003c\/strong\u003e) modullari kabi tashuvchi uskunalarning maxsus SFP slotlariga bevosita o‘rnatish uchun mo‘ljallangan. U mahalliy universal RX3i kirish\/chiqish stendlarini markazlashtirilgan PROFINET I\/O Controller qurilmasiga katta masofalar orqali ulash uchun yuqori tezlikdagi, shovqinga chidamli optik tolali ulanishlarni ta’minlaydi.\u003c\/p\u003e\n\u003cp\u003eStandart 100Base-FX protokol qatlami orqali ishlaydigan \u003cstrong\u003eIC695SPF002\u003c\/strong\u003e ko‘p rejimli tola (MMF) infratuzilmasida 100 Mbit\/s tezlikdagi Fast Ethernet aloqa imkonini beradi. U signal sifatini yo‘qotmasdan ma’lumotlarni 2 kilometrgacha bo‘lgan jismoniy masofaga uzatishi mumkin. Mis elektr toklaridan ko‘ra yorug‘lik impulslaridan foydalanadigan ushbu optik transiver yer halqalari, yuqori kuchlanishli kuchlanish sakrashlari hamda og‘ir sanoat ish zonalarida odatda uchraydigan kuchli elektromagnit yoki radiochastotali xalaqitlardan (EMI\/RFI) to‘liq izolyatsiyani ta’minlaydi. \u003cstrong\u003eIC695SPF002\u003c\/strong\u003e liniyali\/zanjirli, yulduzsimon yoki Media Redundancy Protocol (MRP) halqali tarmoqlarni o‘z ichiga olgan mustahkam, uzoq masofali tarmoq topologiyalarini yaratish uchun muhim hisoblanadi.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlari\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePACSystems RX3i tarmoq modullariga bevosita integratsiya qilish uchun ishlab chiqilgan.\u003c\/li\u003e\n\u003cli\u003eStandart 100Base-FX Fast Ethernet aloqa qatlamidan foydalanadi.\u003c\/li\u003e\n\u003cli\u003eSanoat korxonalarining optimallashtirilgan konfiguratsiyalari uchun ko‘p rejimli tola (MMF) arxitekturasida ishlaydi.\u003c\/li\u003e\n\u003cli\u003eTarmoq infratuzilmasi ulanishlarini 2 kilometrgacha bo‘lgan masofalarda qo‘llab-quvvatlaydi.\u003c\/li\u003e\n\u003cli\u003eIxcham SFP dizayni xost uskunasi slotlariga ishlash vaqtida ulash imkonini beradi.\u003c\/li\u003e\n\u003cli\u003eXost darajasidagi diagnostika bilan to‘liq mos keladi, aloqa liniyasi holati va xatolarni kuzatishni ko‘rsatadi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo‘llanilishi\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKirish\/chiqish stansiyalarini alohida ishlab chiqarish liniyalari, zavodning turli binolari yoki dala obyektlari bo‘ylab taqsimlash.\u003c\/li\u003e\n\u003cli\u003eO‘zgaruvchan chastotali yuritmalar (VFD), kuch transformatorlari va payvandlash zonalari yaqinidagi yuqori shovqinli qayta ishlash muhitlari.\u003c\/li\u003e\n\u003cli\u003eNosozliklarga chidamli avtomatlashtirish magistrallari uchun Industrial Media Redundancy Protocol (MRP) aloqa halqalari.\u003c\/li\u003e\n\u003cli\u003eUzoq masofalarda optik izolyatsiyani talab qiladigan suvni tozalash, kimyoviy qayta ishlash va elektr energiyasini taqsimlash infratuzilmalari.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuyurtma berish ma’lumotlari\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eQism raqami\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTavsif\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695SPF002\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRX3i 100Base-FX (2 km optik tolali) SFP (ko‘p modali optik tola — MMF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTexnik xususiyatlar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTexnik xususiyat\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlab chiqaruvchi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation Solutions \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC695SPF002 (A reviziyasi varianti: IC695SPF002A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMahsulot turi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKichik form-faktorli plaginli (SFP) optik qabul qiluvchi-uzatgich \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarmoq aloqa protokoli\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Base-FX \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQo‘llab-quvvatlanadigan optik tolali kabel muhiti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKo‘p modali optik tola (MMF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksimal ish masofasi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 km \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUzatish tezligi \/ tezlik\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mbps Fast Ethernet \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptik tolali interfeys ulanishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplex optik port tuzilishi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eXost tomonidan ajratilgan tok sarfi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHar bir faol SFP sloti uchun 0.35 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtrof-muhit haroratining ta’siri\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100MB Fiber SFP modullari o‘rnatilganda xost modullari (PNS) maksimal ish harorati chegarasini 57 degC gacha pasaytiradi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUlanishlar va interfeyslar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort elementi\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunksiya \/ tayinlanishi\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptik TX porti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKetma-ketlashtirilgan 100Base-FX ma’lumot signallarini ko‘p modali optik tolaga yuboruvchi lazer nurlatgich porti \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptik RX porti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKo‘p modali optik tolali kabeldan kelayotgan ma’lumot signallarini qabul qiluvchi fotodiod porti \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP interfeys ulagichi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXost SFP uyasi ichidagi qator kontakt liniyalariga ulanadigan ko‘p kontaktli orqa ulagich \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eO‘rnatish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptik nurlanishdan ehtiyot choralari:\u003c\/strong\u003e SFP qabul qiluvchi-uzatgichlari optik tolali aloqa signallarini hosil qilish uchun ko‘rinmas lazer nuridan foydalanadi. Optik tolali kabel uzilgan bo‘lsa, ochiq va himoyalanmagan port ichiga hech qachon to‘g‘ridan-to‘g‘ri qaramang. Bo‘sh slotlarni tegishli chang qopqoqlari bilan yopiq holda saqlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYuqori haroratda chiqarib olish xavfi:\u003c\/strong\u003e Xost skaneri yoki orqa panel yaqinidagi mahalliy havo harorati 40 degC dan oshganda, faol SFP qabul qiluvchi-uzatgichlarining tashqi korpusi 70 degC (158 degF) dan yuqori haroratgacha qizishi mumkin. Yalang‘och terini kuydirib olmaslik uchun qizigan qabul qiluvchi-uzatgich modulini uning uyasidan chiqarishda izolyatsiyalangan himoya qo‘lqoplaridan yoki uchlari ingichka ombirlardan foydalaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKabelning zo‘riqishi va bukilish cheklovlari:\u003c\/strong\u003e Ko‘p modali optik tolali kabellarni ishlab chiqaruvchi tomonidan belgilangan minimal bukilish radiusidan oshirmagan holda doimo xavfsiz yo‘naltiring. Bu optik ma’lumot uzatishning optimal bo‘lishini ta’minlaydi va ichki fizik yoriqlarning oldini oladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarmoq holatini tekshirish:\u003c\/strong\u003e Tarmoq holatini kuzatish uchun xost modulidagi o‘rnatilgan diagnostik LED indikatorlardan foydalaning. Tegishli port indikatori barqaror 100 Mbps ulanish o‘rnatilganda doimiy yashil rangda yonadi yoki slot ichida mos kelmaydigan yoxud sertifikatlanmagan SFP varianti aniqlansa, doimiy qizil rangda yonadi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695421780331,"sku":"IC695SPF002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695spf002a-rx3i-sfp-transceiver-module-0yvqxj4h3b4_d1957228-c5d4-4471-9d0b-57521a9464ca.jpg?v=1766135444","url":"https:\/\/www.plcprotech.com\/uz\/products\/ge-fanuc-ic695spf002-rx3i-small-form-factor-pluggable-transceiver-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}