{"product_id":"honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-module","title":"Honeywell 51196653-100 TDC 3000 besh slotli fayl quvvat ta’minoti moduli","description":"\u003ch3\u003eTavsif\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHoneywell 51196653-100\u003c\/strong\u003e — TotalPlant Solution (TPS) va TDC 3000 boshqaruv arxitekturalaridagi Local Control Network (LCN) tugun shassisi fayllari uchun barqaror ish quvvatini ta’minlashga mo‘ljallangan, shassiga o‘rnatiladigan \u003cstrong\u003eTDC 3000 Five-slot File Power Supply\u003c\/strong\u003e quvvat manbai. 55 A chiqish quvvatiga ega ushbu quvvat manbai moduli orqa paneldagi fayl majmuasi bo‘ylab tugun protsessor platalari, koprotsessorlar, yuritma lotoklari va periferik kiritish-chiqarish modullarini quvvatlantiradi.\u003c\/p\u003e\n\u003cp\u003eTizimning yuqori darajadagi mavjudligini ta’minlash uchun ishlab chiqilgan, \u003cstrong\u003e51196653-100\u003c\/strong\u003e Unda old tomondan foydalaniladigan jumper orqali boshqariladigan kuchlanish chegaralarini sozlash funksiyasi mavjud. Bu imkoniyat tizim muhandislariga diagnostika sinovlari va zavoddagi nosozliklarni bartaraf etish vaqtida chiqish kuchlanishi chegaralarini +5% ga sozlash imkonini beradi. Modul old paneldagi quvvat tugmasi, tiklash boshqaruvi va maxsus holat indikatorlarini birlashtirib, ta’minot yaxlitligi haqida darhol mahalliy fikr-mulohaza beradi.\u003c\/p\u003e\n\u003cp\u003eYevropa EMC hamda sog‘liq va xavfsizlik direktivalariga muvofiq ishlab chiqilgan CE talablariga mos \u003cstrong\u003eHoneywell 51196653-100\u003c\/strong\u003e standart 3 kontaktli o‘zgaruvchan tok ulagichi interfeysi va yuqori samarali ventilyatorli sovitishni birlashtirib, uzluksiz sanoat avtomatlashtirish muhitlarida ishonchli issiqlik boshqaruvini ta’minlaydi.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYuqori sig‘imli tok uzatish:\u003c\/strong\u003e Ko‘p slotli LCN tugun majmualari, protsessorlar va disk lotoklarini qo‘llab-quvvatlash uchun orqa panel bo‘ylab 55 A gacha tartibga solingan quvvat yetkazib beradi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKuchlanish chegaralarini sinash imkoniyatlari:\u003c\/strong\u003e Texnik xizmat ko‘rsatish sinovlari va nosozliklarni bartaraf etish jarayonlari uchun kuchlanishni +5% ga yuqori chegara qiymatiga sozlash imkonini beruvchi, old tomondan foydalaniladigan jumper bilan jihozlangan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOld panelga integratsiyalangan diagnostika:\u003c\/strong\u003e Haqiqiy vaqtda vizual kuzatuv va boshqaruv uchun maxsus Power OK holat LED indikatori, quvvat tugmasi va qo‘lda tiklash tugmasini o‘z ichiga oladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE talablariga mos xavfsizlik arxitekturasi:\u003c\/strong\u003e Sanoat boshqaruv korpuslari uchun Yevropa Ittifoqining EMC hamda sog‘liq va xavfsizlik direktivalariga to‘liq mos keladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandart sanoat o‘zgaruvchan tok kirishi:\u003c\/strong\u003e Oddiy va xavfsiz quvvat ulanishi uchun standart 3 kontaktli o‘zgaruvchan tok ulagichiga ega.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMajburiy havo orqali issiqlikni boshqarish:\u003c\/strong\u003e O‘rnatilgan ventilyator majmuasi uzluksiz ichki sovitishni ta’minlab, 5-slotli fayl shassisi ichidagi optimal ish haroratini saqlaydi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo‘llanilishi\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTDC 3000 va TPS LCN tugunlari:\u003c\/strong\u003e Application ModuleX (AXM) protsessorlari, K2LCN yoki K4LCN tugun platalari joylashadigan 5-slotli fayl shassisi uchun asosiy quvvatni o‘zgartirish moduli.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanoat boshqaruv fayli korpuslari:\u003c\/strong\u003e Xotira modullari, koprotsessor platalari va qattiq disk yuritmalari lotoklari uchun umumiy orqa panellar bo‘ylab toza doimiy tok quvvat taqsimotini ta’minlaydi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJarayonlarni avtomatlashtirish bo‘yicha texnik xizmat va modernizatsiya:\u003c\/strong\u003e Tizimni yangilash va texnik xizmat ko‘rsatish jarayonida eskirgan DCS infratuzilmasi uchun almashtiriladigan shassi quvvat ta’minoti moduli.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTexnik xususiyatlar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametr\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpetsifikatsiya\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIshlab chiqaruvchi\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel raqami\u003c\/td\u003e\n\u003ctd\u003e51196653-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMahsulot turi\u003c\/td\u003e\n\u003ctd\u003eTDC 3000 besh slotli fayl quvvat ta’minoti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiqish toki nominali\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKuchlanish marjalash opsiyalari\u003c\/td\u003e\n\u003ctd\u003e+5% yuqori marja (zavod\/sinov jumperi orqali boshqariladi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePast marja chegarasi\u003c\/td\u003e\n\u003ctd\u003e-5% (AXM fayl shassilarida foydalanish cheklangan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOld panel boshqaruvlari\u003c\/td\u003e\n\u003ctd\u003eQuvvatni yoqish\/o‘chirish tugmasi, Reset tugmasi, marjalash jumperi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOld panel indikatorlari\u003c\/td\u003e\n\u003ctd\u003ePower OK LED indikatori\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKirish ulanishi\u003c\/td\u003e\n\u003ctd\u003eStandart 3 kontaktli ulagich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorpus mosligi\u003c\/td\u003e\n\u003ctd\u003e5-slotli LCN tugun shassisi \/ fayl yig‘masi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSovitish\u003c\/td\u003e\n\u003ctd\u003eIntegratsiyalangan ventilyator moduli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMuvofiqlik\u003c\/td\u003e\n\u003ctd\u003eCE talablariga mos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTashish og‘irligi\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eO‘rnatish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eXavfsizlik bo‘yicha dastlabki tekshiruv:\u003c\/strong\u003e Quvvat ta’minotini fayl shassisiga o‘rnatish yoki undan chiqarishdan oldin asosiy o‘zgaruvchan tok manbaini uzing. ESDdan himoyalovchi to‘g‘ri yerga ulash tartiblariga rioya qilinganini ta’minlang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumperni tekshirish:\u003c\/strong\u003e Jarayon faol uskunasini yoqishdan oldin old paneldagi kuchlanish marjasi jumperi Normal (\"Norm\") holatida qulflanganini tekshiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShassi bilan tekislash:\u003c\/strong\u003e Quvvat ta’minoti modulini 5-slotli fayl shassisining chap tomondagi quvvat slotiga orqa panel ulagichlari mahkam o‘rnashguncha silliq surib kiriting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO‘zgaruvchan tok ulanishi:\u003c\/strong\u003e Asosiy quvvat liniyasini standart 3 kontaktli ulagich interfeysi orqali ulang.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTizimni ishga tushirish:\u003c\/strong\u003e Old paneldagi almashtirish tugmasi yordamida quvvatni yoqing. Yashil \"Power OK\" LED indikatori yonganini va ventilyator havo oqimi faol ekanini tekshiring.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eAlmashtirish bo‘yicha tavsiyalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuvvatni o‘chirishdan oldin dasturiy ta’minotni to‘xtatish:\u003c\/strong\u003e Quvvatni o‘chirish yoki quvvat ta’minotini olib tashlashdan oldin tugun protsessori dasturiy ta’minoti va koprotsessor operatsion tizimlarini (masalan, AXM tugunlaridagi HP-UX) har doim tartibli tarzda o‘chiring. Quvvatni ogohlantirmasdan uzish qattiq disk lotoklaridagi fayl tizimlarining buzilishiga olib kelishi mumkin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKuchlanish marjalash cheklovlari:\u003c\/strong\u003e AXM tugunlari yoki qattiq disk lotoklari o‘rnatilgan shassilarda past quvvat marjasi opsiyasi (-5%) \u003cstrong\u003eHECH QACHON\u003c\/strong\u003e tanlanmasligi kerak, chunki ularning apparat dizayni quvvat ta’minotidagi juda tor og‘ish oralig‘ini (maksimal -2,5% pasayish) talab qiladi. Past marjada ishlash tizimning oldindan aytib bo‘lmaydigan xatti-harakatiga yoki disk nosozliklariga olib keladi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJarayon cheklovlari:\u003c\/strong\u003e Tugun faol jarayonni boshqarayotgan yoki onlayn jarayonda ishtirok etayotgan paytda yuqori (+5%) yoki past (-5%) marja sinovlarini bajarmang.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759559019,"sku":"51196653-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-hid4xug3c1l_599db822-3779-4818-a011-a23882dc7f5e.jpg?v=1765501685","url":"https:\/\/www.plcprotech.com\/uz\/products\/honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}