{"product_id":"honeywell-lg1093ac01-gas-turbine-lg-flame-detector","title":"Honeywell LG1093AC01 Gas Turbine LG Flame Detector","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell LG1093AC01\u003c\/strong\u003e is a ultraviolet (UV) radiation flame detector engineered for gas turbine flame monitoring systems. The unit senses the UV radiation emitted by a hydrocarbon flame and transmits a high-speed signal to indicate a flame or no-flame condition. Utilizing a Geiger Mueller-type phototube sensor, the detector is solar blind and tolerant to black body radiation. It is widely applied across General Electric and GE licensee gas turbines for power generation and compressor operations, delivering high sensitivity with typical response times of 0.1 seconds for flame presence.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeiger Mueller-type sensor phototube detecting UV radiation in the 180 to 260 nm spectral range\u003c\/li\u003e\n\u003cli\u003eSolar blind design tolerant to black body radiation\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity with typical 0.1-second Flame Present Response Time and 0.2-second maximum Flame Loss Response Time\u003c\/li\u003e\n\u003cli\u003eTwo-year shelf life and 10,000-hour MTBF\u003c\/li\u003e\n\u003cli\u003eLong-distance sensor-to-amplifier signal transmission capability up to 330 m (1000 ft)\u003c\/li\u003e\n\u003cli\u003eSealed viewing window rated for pressures up to 428 mbar (6.3 psi)\u003c\/li\u003e\n\u003cli\u003eIntegrated 9 ft (2.7 m) 2-conductor armored cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral Electric (and GE licensee) heavy-duty gas turbines\u003c\/li\u003e\n\u003cli\u003ePower generation gas turbine flame monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor gas turbine installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct No.\u003c\/td\u003e\n\u003ctd\u003eLG1093AC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLG Flame Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eGeiger Mueller-type phototube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Range\u003c\/td\u003e\n\u003ctd\u003e180 to 260 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to 176 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9 ft (2.7 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e2-conductor armored cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.73 in. O.D. by 0.14 in. wide flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing Window Pressure Rating\u003c\/td\u003e\n\u003ctd\u003e428 mbar (6.3 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Required\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Present Response Time\u003c\/td\u003e\n\u003ctd\u003e0.1 sec typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Loss Response Time\u003c\/td\u003e\n\u003ctd\u003e0.2 sec max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e10,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 330 m (1000 ft) from sensor to amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Output Compatibility\u003c\/td\u003e\n\u003ctd\u003eEG1033 series amplifier modules only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplifier Compatibility:\u003c\/strong\u003e Hardware outputs are designed exclusively for connection to Honeywell EG1033 series amplifier modules (EG1033AA, EG1033AB, EG1033AC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Distance:\u003c\/strong\u003e Ensure proper routing of the attached 2-conductor armored cable. Sensor-to-amplifier runs can extend up to 330 m (1000 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e Verify that process conditions at the viewing interface do not exceed the window rating of 428 mbar (6.3 psi).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Mounting:\u003c\/strong\u003e Observe all local codes and area classification constraints when mounting in classified explosive environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-NOx Exception Note:\u003c\/strong\u003e Standard LG1093 series detectors may not function as expected on GE\/NP DLE (Dry Low NOx) gas turbines; these applications require specialized pre-selected variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE \/ ATEX:\u003c\/strong\u003e EEx d IIA T3 or EEx d IIC T3, Zone 1 and 2 (Directive 94\/9\/EC, EMC 89\/336\/EEC, LVD 73\/23\/EEC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM):\u003c\/strong\u003e Class I, Div 1 and 2, Groups B, C, and D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53627954168171,"sku":"LG1093AC01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/LG1093AC01.jpg?v=1785374504","url":"https:\/\/www.plcprotech.com\/uz\/products\/honeywell-lg1093ac01-gas-turbine-lg-flame-detector","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}