{"product_id":"honeywell-tc-odd321-experion-dc-output-module","title":"Honeywell TC-ODD321 Experion doimiy tok chiqish moduli","description":"\u003cp\u003e\u003cstrong\u003eHoneywell TC-ODD321\u003c\/strong\u003e — Experion shassisi I\/O platformasi uchun 24 VDC raqamli chiqish moduli. U har bir umumiy yer ulanishiga 16 ta nuqtadan iborat ikki guruhga sozlangan, izolyatsiya qilinmagan 32 ta chiqish kanaliga ega. Solenoidlar, relelar va indikatorlar kabi dala qurilmalarini boshqarish uchun mo‘ljallangan ushbu qurilma Experion C200\/C200E kontrollerlaridan keladigan raqamli boshqaruv signallarini tezkor, qattiq holatli javob bilan qayta ishlaydi.\u003c\/p\u003e\n\u003ch3\u003eXususiyatlari\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 ta chiqish nuqtasi:\u003c\/strong\u003e 16 ta nuqtadan iborat 2 ta alohida guruhga, har biri umumiy ulanishga birlashtirilgan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChiziqli kamaytirish:\u003c\/strong\u003e 50 °C gacha to‘liq tok yuklamalarini, 60 °C gacha esa boshqariladigan chiziqli issiqlik kamaytirishini qo‘llab-quvvatlaydi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTezkor kommutatsiya javobi:\u003c\/strong\u003e Yoqish\/o‘chirish signali kechikishi maksimal 1,0 ms bilan cheklangan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSozlanadigan kanal holatlari:\u003c\/strong\u003e Nosozlik holatlarida yoki dastur rejimida alohida kanallarni oxirgi holatini saqlash yoki standart bo‘yicha YOQILGAN yoki O‘CHIRILGAN holatga o‘rnatish mumkin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIssiq almashtirish:\u003c\/strong\u003e Xavfsiz hududdagi qurilmalarda quvvat yoqilgan holda olib tashlash va o‘rnatishni (RIUP) qo‘llab-quvvatlaydi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQo‘llanilishi\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24 VDC sanoat solenoidlari va aktuator g‘altaklarini boshqarish\u003c\/li\u003e\n\u003cli\u003eOraliq boshqaruv relelari va kontaktorlarini ishga tushirish\u003c\/li\u003e\n\u003cli\u003eDala indikator chiroqlari va signalizatsiya panellarini boshqarish\u003c\/li\u003e\n\u003cli\u003eAvtomatlashtirish interfeysi chiqishlarini tashqi quyi tizim mantiqiga ulash\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTexnik xususiyatlar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametr\u003c\/th\u003e\n\u003cth\u003eSpetsifikatsiya\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIshlab chiqaruvchi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-ODD321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMahsulot turi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiskret chiqish moduli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqishlar soni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 (har bir umumiy ulanishga 16 nuqta)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish kuchlanish diapazoni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 °C da 10–31,2 VDC (chiziqli kamaytirish), 60 °C da 10–28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish toki nominal qiymati (har bir nuqta uchun)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 °C da maksimal 0,5 A (chiziqli kamaytirish), 60 °C da maksimal 0,35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish toki nominal qiymati (har bir modul uchun)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 °C da maksimal 16 A (chiziqli kamaytirish), 60 °C da maksimal 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZarba toki\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHar biri 10 ms davomida 1 A, 60 °C da har 2 soniyada takrorlanishi mumkin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYoqilgan holatdagi minimal yuklama toki\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHar bir chiqishga 3,0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaksimal yoqilgan holatdagi kuchlanish pasayishi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal tok bo‘yicha har bir nuqtaga 1 VDC (IEC 1131-2 uchun 3 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO‘chirilgan holatdagi maksimal sizib chiqish toki\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHar bir nuqtaga 0,5 mA (0,25 A chiqish uchun IEC 1131-2 bo‘yicha har bir nuqtaga 1 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiqish kechikish vaqti (o‘chiqdan yoqilgan holatga \/ yoqilgandan o‘chirilgan holatga)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaksimal 1,0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuvvat sarfi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSaqlagich bilan himoyalash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHimoyalanmagan (saqlagichli terminal kolodkasi\/IFM tavsiya etiladi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTeskari qutblanishdan himoya\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMavjud emas (noto‘g‘ri ulash modulga zarar yetkazishi mumkin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIzolyatsiya kuchlanishi (guruhdan guruhgacha)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2546 VDC kuchlanishda 1 soniya davomida 100% sinovdan o‘tkazilgan (uzluksiz maksimal 250 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIzolyatsiya kuchlanishi (foydalanuvchidan tizimgacha)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2546 VDC kuchlanishda 1 soniya davomida 100% sinovdan o‘tkazilgan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal kolodkasi ulagichi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH (36 kontaktli terminal kolodkasi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUlanishlar\/interfeyslar\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal ulanishi\u003c\/th\u003e\n\u003cth\u003eFunksiya\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUlanish turi\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH 36 kontaktli olinadigan terminal kolodkasi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKabel yig‘masi opsiyasi\u003c\/td\u003e\n\u003ctd\u003eOldindan ulangan 1492-HWCAB yoki 1492-CABLE tizimi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasofaviy interfeys opsiyasi\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley 1492-IFM \/ 1492-XIM seriyali RTP’lar bilan mos keladi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eO‘rnatish bo‘yicha ko‘rsatmalar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQutblanish haqida ogohlantirish\u003c\/strong\u003e: Modul teskari qutblanishdan himoyalanmagan; ichki chiqish zanjirlariga zarar yetkazmaslik uchun simlar qutblanishi to‘g‘ri ulanganiga ishonch hosil qiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTashqi zanjirni himoyalash\u003c\/strong\u003e: Chiqishlar ichki saqlagichlar bilan himoyalanmagan. Alohida kanallarni ortiqcha tokdan himoyalash uchun saqlagichli masofaviy terminal panellari (RTP) yoki interfeys modullaridan foydalaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIssiqlikni boshqarish\u003c\/strong\u003e: Belgilangan ish harorati chegaralarida tabiiy konveksiya orqali to‘g‘ri sovitishni ta’minlash uchun korpuslar ichida shassi atrofida yetarli bo‘sh joy qoldiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXavfli joylarda RIUP\u003c\/strong\u003e: Atrof-muhit xavfli joy sifatida tasniflangan bo‘lsa, quvvat yoqilgan paytda modullarni chiqarmang yoki o‘rnatmang.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMuvofiqlik va sertifikatlar\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\u003c\/strong\u003e: UL 508 sanoat boshqaruv uskunalari\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXavfli joylar\u003c\/strong\u003e: I sinf, 2-bo‘lim, A, B, C va D guruhlari — xavfli va oddiy joylar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC direktivalari\u003c\/strong\u003e: 89\/336\/EEC EMC direktivasi, EN 50081-2 (emissiyalar), EN 50082-2 (immunitet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick\u003c\/strong\u003e: 1992-yildagi Avstraliya radioaloqa qonuniga muvofiq\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705777811819,"sku":"TK-ODD321","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-ODD321_005_1200x1200_20f93688-c6ea-46c8-912e-91b9922db054.jpg?v=1785990770","url":"https:\/\/www.plcprotech.com\/uz\/products\/honeywell-tc-odd321-experion-dc-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}