{"title":"ABB S800 I\/O","description":"\u003cp\u003eThe ABB S800 I\/O is a comprehensive, distributed process I\/O system that communicates over Advant Fieldbus 100 or PROFIBUS DP. Its modular architecture consists of communication interfaces, terminal bases, and high-density I\/O modules such as the DI8, DO81, and AI8 series. Technical characteristics include hot-swap capability (MTU), modular redundancy, and G3 conformal coating for harsh environments. Functionally, S800 I\/O provides a bridge between field sensors and the controller, supporting sequence of events (SOE) and HART pass-through. This versatility makes it the preferred choice for integrating field signals into the 800xA system, ensuring high availability and precision in critical industrial automation processes.\u003c\/p\u003e","products":[{"product_id":"abb-tu838-3bse008572r1-s800-i-o-extended-module-termination-unit","title":"Đơn vị kết thúc mô-đun mở rộng ABB TU838 3BSE008572R1 S800 I\/O","description":"\u003ch3\u003eTổng quan sản phẩm\u003c\/h3\u003e\n\u003cp\u003eABB \u003cstrong\u003eTU838 (3BSE008572R1)\u003c\/strong\u003e là Đơn vị Kết thúc Mô-đun Mở rộng I\/O S800 được thiết kế cho hệ thống điều khiển phân tán ABB. Nó cung cấp giao diện điện và cơ học giữa dây trường và các mô-đun I\/O S800 trong kiến trúc System 800xA.\u003c\/p\u003e\n\u003cp\u003eMTU này phân phối nguồn quá trình, định tuyến tín hiệu ModuleBus và hỗ trợ cấu hình I\/O lên đến 16 kênh. Nó được sử dụng rộng rãi trong môi trường tự động hóa quy trình nơi cần kết thúc tín hiệu ổn định và mở rộng mô-đun.\u003c\/p\u003e\n\u003cp\u003eTU838 hỗ trợ đầu ra nguồn cảm biến có cầu chì, đường cấp nguồn L+ \/ L- dự phòng và mã hóa cơ học để ngăn chặn lắp sai mô-đun.\u003c\/p\u003e\n\u003ch3\u003eTính năng chính\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eĐơn vị kết thúc I\/O S800 16 kênh\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTương thích với ABB System 800xA và Advant OCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhân phối nguồn cảm biến có cầu chì tích hợp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHệ thống khóa cơ học ngăn chặn lắp sai mô-đun\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLắp đặt trên ray DIN với chốt nối đất tích hợp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHỗ trợ nguồn quá trình L+ \/ L- dự phòng\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eĐịa chỉ tuần tự ModuleBus tự động\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThiết kế cho hệ thống tự động hóa quy trình công nghiệp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông số kỹ thuật kỹ thuật\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eTham số\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eThông số kỹ thuật\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThương hiệu\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMẫu\u003c\/td\u003e\n\u003ctd\u003eTU838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMã sản phẩm\u003c\/td\u003e\n\u003ctd\u003e3BSE008572R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDòng hệ thống\u003c\/td\u003e\n\u003ctd\u003eI\/O S800 (Hệ thống 800xA \/ Advant OCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoại\u003c\/td\u003e\n\u003ctd\u003eĐơn vị Kết thúc Mô-đun Mở rộng\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKênh\u003c\/td\u003e\n\u003ctd\u003e16 kênh I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eĐiện áp tối đa\u003c\/td\u003e\n\u003ctd\u003e50 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDòng tối đa\u003c\/td\u003e\n\u003ctd\u003e3 A mỗi kênh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTổng dòng\u003c\/td\u003e\n\u003ctd\u003eDòng tối đa 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNguồn quá trình\u003c\/td\u003e\n\u003ctd\u003eNguồn L+ \/ L- dự phòng\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoại cầu chì\u003c\/td\u003e\n\u003ctd\u003eCầu chì nhanh 100 mA (tối đa 3.5 A có thể thay thế tại hiện trường)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eĐánh giá ModuleBus\u003c\/td\u003e\n\u003ctd\u003e1.5 A @ 5 V \/ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLắp đặt\u003c\/td\u003e\n\u003ctd\u003eRay DIN 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBảo vệ\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKích thước\u003c\/td\u003e\n\u003ctd\u003e58.5 × 64 × 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrọng lượng\u003c\/td\u003e\n\u003ctd\u003e0.375 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXuất xứ\u003c\/td\u003e\n\u003ctd\u003eThụy Điển\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMã HS\u003c\/td\u003e\n\u003ctd\u003e85369095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChức năng và Kiến trúc Hệ thống\u003c\/h3\u003e\n\u003cp\u003eTU838 hoạt động như một mô-đun kết thúc và phân phối thụ động trong hệ thống I\/O S800. Nó không xử lý tín hiệu mà cung cấp định tuyến có cấu trúc giữa thiết bị trường và mô-đun I\/O.\u003c\/p\u003e\n\u003cp\u003eGiao tiếp ModuleBus sử dụng phát hiện khe cắm tuần tự, cho phép địa chỉ tự động mà không cần cấu hình phần mềm. Mỗi MTU truyền tín hiệu vị trí đến thiết bị tiếp theo trong chuỗi ray DIN.\u003c\/p\u003e\n\u003cp\u003eThiết bị cũng phân phối nguồn quá trình qua các nhóm đầu ra có cầu chì, bảo vệ các thiết bị trường kết nối khỏi tình trạng quá tải.\u003c\/p\u003e\n\u003ch3\u003eHướng dẫn lắp đặt và đi dây\u003c\/h3\u003e\n\u003cp\u003eViệc lắp đặt đúng cách là cần thiết để hệ thống hoạt động ổn định.\u003c\/p\u003e\n\u003cp\u003eGắn thiết bị lên thanh ray DIN 35 mm theo vị trí ngang. Đảm bảo thanh ray DIN được nối đất đúng cách bằng cách liên kết trở kháng thấp với hệ thống đất của tủ.\u003c\/p\u003e\n\u003cp\u003eGiữ chiều dài bóc dây 7 mm và siết chặt vít đầu cuối ở 0,5–0,6 Nm. Sử dụng khoảng cách thích hợp giữa dây tín hiệu và dây nguồn AC để giảm nhiễu điện từ.\u003c\/p\u003e\n\u003cp\u003eDây trường được chia thành 16 kênh tín hiệu với đầu ra cảm biến có cầu chì nhóm. Một số cấu hình cho phép chia sẻ nhóm cầu chì tùy theo thiết kế mô-đun.\u003c\/p\u003e\n\u003ch3\u003eHệ thống khóa cơ học\u003c\/h3\u003e\n\u003cp\u003eTU838 bao gồm hệ thống khóa cơ học kép với sáu vị trí chọn cho mỗi chìa khóa, cho phép 36 tổ hợp cấu hình.\u003c\/p\u003e\n\u003cp\u003eĐiều này ngăn chặn việc lắp sai mô-đun I\/O S800 như AI810, DI810 hoặc DO814. Hệ thống đảm bảo tính tương thích cơ học và bảo vệ mạch bên trong khỏi điện áp trường sai.\u003c\/p\u003e\n\u003ch3\u003eYêu cầu về EMC và nối đất\u003c\/h3\u003e\n\u003cp\u003eHoạt động ổn định yêu cầu nối đất đúng cách và thiết kế EMC phù hợp.\u003c\/p\u003e\n\u003cp\u003eThanh ray DIN đóng vai trò là kết nối đất chức năng thông qua cơ chế khóa tích hợp. Tủ phải được nối với hệ thống đất có trở kháng thấp bằng dây đồng bện.\u003c\/p\u003e\n\u003cp\u003eCáp tín hiệu nên được tách biệt khỏi cáp nguồn để giảm thiểu nhiễu. Tránh đi dây song song dài giữa đường điện cao áp và thấp áp.\u003c\/p\u003e\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cp\u003eABB TU838 được sử dụng trong:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHệ thống tự động hóa quy trình công nghiệp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHệ thống điều khiển dầu khí\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNhà máy phát điện\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKiến trúc ABB System 800xA DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTự động hóa nhà máy quy mô lớn\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMạng lưới thiết bị đo an toàn quan trọng\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông tin đặt hàng\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMã sản phẩm: 3BSE008572R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoại ABB: TU838\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHệ thống: I\/O S800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSố lượng đặt hàng tối thiểu: 1 chiếc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCâu hỏi thường gặp\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChức năng của TU838 trong hệ thống I\/O S800 là gì?\u003c\/strong\u003e\u003cbr\u003eNó cung cấp chức năng kết thúc tín hiệu, phân phối nguồn và định tuyến ModuleBus giữa dây trường và các mô-đun I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTU838 có yêu cầu cấu hình phần mềm không?\u003c\/strong\u003e\u003cbr\u003eKhông. Địa chỉ mô-đun được xử lý tự động thông qua tín hiệu ModuleBus tuần tự.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCó thể thay thế cầu chì không?\u003c\/strong\u003e\u003cbr\u003eCó. Cầu chì có thể thay thế tại hiện trường và có thể nâng cấp tùy theo yêu cầu ứng dụng.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eĐiều gì sẽ xảy ra nếu nối đất không chính xác?\u003c\/strong\u003e\u003cbr\u003eĐất không đúng cách có thể dẫn đến nhiễu EMC, tín hiệu không ổn định hoặc lỗi giao tiếp hệ thống.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668497920363,"sku":"TU838 3BSE008572R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu838-3bse008572r1-tu838-extended-module-termination-unit-releuqkxedv_4820a9c5-09fa-4dcf-94fb-295b49e567ab.jpg?v=1765532469"},{"product_id":"abb-3bse061579r1-xf801-s800-i-o-fast-i-o-module","title":"ABB 3BSE061579R1 XF801 S800 I\/O Fast I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eXF801\u003c\/strong\u003e processes high-speed digital signals within distributed automation frameworks, serving as a specialized interface for time-critical subprocess operations. This hardware subassembly operates within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e platform to execute rapid signal transformation, reducing propagation delays between primary field instrumentation and the controller core. Fully compatible with \u003cstrong\u003eAC 800M Control Software 5.1\u003c\/strong\u003e and broader \u003cstrong\u003eSystem 800xA\u003c\/strong\u003e architectures, the module acts as a fast-response localized subsystem to ensure high-frequency processing demands are met with strict deterministic execution. Its integrated design allows seamless mounting inside standard system line-ups, expanding standard distributed I\/O control topologies into specialized fast-acting process zones.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed cycle processing dedicated for time-critical subprocess monitoring\u003c\/li\u003e\n\u003cli\u003eFull integration alignment within the S800 I\/O and AC 800M controller bus structure\u003c\/li\u003e\n\u003cli\u003eLow propagation delay architecture for optimized signal turnaround performance\u003c\/li\u003e\n\u003cli\u003eForm-factor optimized for standardized panel layout positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-frequency industrial process tracking\u003c\/li\u003e\n\u003cli\u003eAC 800M distributed controller node expansion\u003c\/li\u003e\n\u003cli\u003eSub-millisecond signal processing sequences\u003c\/li\u003e\n\u003cli\u003eSectional process line automation deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXF801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE061579R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Mount the module carefully onto the designated S800 system station base to ensure complete engagement of structural internal logic connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e Observe appropriate electro-static handling criteria during unboxing and physical mounting routines to protect fast-switching internal semiconductors from static breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Integrity:\u003c\/strong\u003e Ensure sufficient free clearance above and below the operational housing cluster to permit natural thermal convection currents inside the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Coordination:\u003c\/strong\u003e Confirm that the accompanying AC 800M controller base firmware aligns with Version 5.1 criteria before attempting online device configuration loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat primary platform does this device support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is engineered to operate exclusively as a component within the S800 I\/O distributed hardware system managed by AC 800M controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat distinguishes this component from standard I\/O options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module provides fast-response processing attributes designed for application paths that cannot tolerate standard digital tracking cycles or traditional latency levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include physical built-in safety barriers for intrinsic safety application zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe engineering data establishes this as a standard fast-response processing module; check specific assembly variants for hazardous field circuit boundaries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the precise standalone mass specification for structural weight calculations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe net weight of the unpackaged hardware module is precisely 1 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device compatible with alternative non-ABB control architectures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module is developed to attach directly to the proprietary bus structures found in System 800xA and compatible platform segments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668512665963,"sku":"3BSE061579R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-xf801-3bse061579r1-fast-i-o-module-ottf4psa4v0_f884a379-cc02-4089-81cc-e170916ad377.jpg?v=1765532563"},{"product_id":"abb-tb820v2-3bse013208r1-s800-i-o-modulebus-cluster-modem","title":"ABB TB820V2 3BSE013208R1 S800 I\/O Modulebus Cluster Modem","description":"\u003cp\u003eThe \u003cstrong\u003eTB820V2\u003c\/strong\u003e with part number \u003cstrong\u003e3BSE013208R1\u003c\/strong\u003e is an optical cluster modem designed for non-redundant communication operations within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system framework. It functions as a specialized interface for the reception, conversion, transmission, and regeneration of data signals across local or wide area industrial networks. The module establishes secure, fiber-optic links between distributed \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e clusters and central controllers, ensuring noise-immune data transfer in harsh environments. Each unit comes packaged with a dedicated power supply connector and a \u003cstrong\u003eTB807 Modulebus Terminator\u003c\/strong\u003e to ensure correct electrical termination of the local bus cluster.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB820V2\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3BSE013208R1: Modulebus Cluster Modem (Non-redundant operation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB820V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013208R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulebus Cluster Modem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant OCS with MOD 300 SW, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Power Supply Connector, 1 x TB807 Modulebus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture Integration\u003c\/strong\u003e: The cluster modem operates within the local Modulebus hierarchy to bridge communication between external controller racks and distributed S800 remote I\/O blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Requirement\u003c\/strong\u003e: Correct bus topology requires the installation of the included TB807 Modulebus Terminator at the physical end of the localized cluster segment to suppress signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Redundant Configuration\u003c\/strong\u003e: This hardware variant is optimized strictly for simplex (non-redundant) communication lines; dual-line pathing architectures require alternative module selections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Platform Compatibility\u003c\/strong\u003e: Fully verified for cross-generational deployment, bridging legacy Advant Fieldbus 100 systems with modern System 800xA control configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Assembly\u003c\/strong\u003e: Mount the unit onto its designated backplane slot within the I\/O chassis, securing any mechanical lock latches to ensure solid alignment with the backplane communication rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection\u003c\/strong\u003e: Use only the provided power supply connector block to land the required operational voltages, ensuring correct polarity before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Handling\u003c\/strong\u003e: Avoid sharp bends or pulling stresses on the optical patch cables connected to the modem interface, as excessive attenuation or physical breakage can degrade cyclic data exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Precautions\u003c\/strong\u003e: Adhere to strict industrial ESD measures, including wearing an approved grounding wrist strap, when handling the modem or installing the terminating plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What physical accessories are included standard in the box with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Every unit ships complete with one power supply connector and one TB807 Modulebus Terminator block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this specific module designation be deployed in a redundant network communication layout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this unit is engineered and specified strictly for non-redundant network configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this hardware module require any internal backup batteries for configuration retention?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the module operates with zero internal batteries, running completely on external system backplane power.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514435435,"sku":"3BSE013208R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tb820v2-3bse013208r1-modulebus-optical-modem-t5d5kfhvioi_0d061849-df46-4de7-9bd4-4c6603e63913.jpg?v=1765532624"},{"product_id":"abb-tb806-3bse008536r1-s800-i-o-modulebus-bus-inlet","title":"ABB TB806 3BSE008536R1 S800 I\/O Modulebus Bus Inlet","description":"\u003cp\u003eThe \u003cstrong\u003eTB806\u003c\/strong\u003e with part number \u003cstrong\u003e3BSE008536R1\u003c\/strong\u003e is a specialized Modulebus bus inlet adapter designed to facilitate physical bus expansion within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e hardware architecture. It features a male D-sub 25-pin connector housing that acts as the hardware bridge to interface standard internal bus signaling with extended field configurations. Exactly one adapter unit is required to properly terminate and connect each \u003cstrong\u003eTK801\u003c\/strong\u003e Modulebus extension cable assembly. This component guarantees the maintenance of continuous, low-impedance connection profiles for control bus lines bridging separate chassis segments across System 800xA, Advant OCS, or Compact Product Suite networks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB806\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3BSE008536R1: Modulebus Extension Cable Adaptor D-sub 25, Male\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE008536R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD-sub 25, male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires 1 pcs per TK801 extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant Fieldbus 100, Advant OCS with MOD 300 SW, Compact Product Suite (Versions 4.1, 5.0, 5.1, 6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85369095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.046 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulebus Segments Integration\u003c\/strong\u003e: The bus inlet serves as a critical connection link for adding distance or shifting layouts via cables between distributed rail segments without causing protocol transmission timing issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatching Cable Requirements\u003c\/strong\u003e: System planning matrices must allocate precisely one inlet plug for every individual TK801 extension cable run deployed in the topology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive Electrical Interface\u003c\/strong\u003e: As a non-powered, mechanical-electrical adaptation interface, this module carries no active firmware or logic properties, minimizing component wear vectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint Deployment\u003c\/strong\u003e: The minimal physical envelope allows clean, space-saving mounting paths inside restricted junction boxes or congested system panel rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Alignment\u003c\/strong\u003e: Align the D-sub 25-pin male connection pattern squarely over the receptacle port before applying force, avoiding skewed paths that bent or crushed pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief\u003c\/strong\u003e: Anchor adjacent TK801 cables to a structural support rail or bracket to prevent localized terminal pull forces from causing intermittent bus open-faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Charge Control\u003c\/strong\u003e: Ensure the field technician is thoroughly grounded using an standard industrial ESD wrist strap during handling and seating phases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Environment Sealing\u003c\/strong\u003e: Keep the connector free from dust, corrosive airborne chemical compounds, and localized moisture tracking to preserve stable contact interface resistances.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668584198507,"sku":"TB806 3BSE008536R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tb806-3bse008536r1-modulebus-extension-cable-adaptor-254v0dndczj_06ef793e-b839-4eb9-934a-b7b868b46030.jpg?v=1765532989"},{"product_id":"abb-tu843-3bse021443r1-s800-i-o-redundant-module-termination-unit","title":"Đơn vị kết thúc mô-đun dự phòng ABB TU843 3BSE021443R1 S800 I\/O","description":"\u003ch3\u003eMô tả\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTU843\u003c\/strong\u003e là một \u003cstrong\u003eĐơn vị Kết thúc Mô-đun (MTU)\u003c\/strong\u003e chuyên dụng được thiết kế để tích hợp với các mô-đun \u003cstrong\u003eI\/O dự phòng\u003c\/strong\u003e trong hệ sinh thái \u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e. Nó đóng vai trò là cơ sở neo cơ học và điện cho hai mô-đun I\/O, tạo ra giao diện vững chắc cho phép thay nóng và cấu hình chuyển đổi dự phòng liền mạch trong các quy trình công nghiệp quan trọng. Cơ sở này hỗ trợ tất cả các kết nối dây hiện trường và các kênh truyền ModuleBus nội bộ mà không làm gián đoạn tín hiệu trong quá trình bảo trì.\u003c\/p\u003e\n\u003cp\u003eĐơn vị này được cấu hình đặc biệt cho \u003cstrong\u003elắp đặt thanh ray DIN dọc\u003c\/strong\u003e, cho phép kỹ sư điều khiển tối ưu hóa bố trí tủ và theo dõi mật độ cao. Hoạt động an toàn trong phạm vi điện áp thấp lên đến \u003cstrong\u003e50V\u003c\/strong\u003e, đơn vị quản lý các đường phân phối tín hiệu rời rạc, analog và vòng truyền thông trong các cơ sở điều khiển tự động được quản lý bởi các mạng điều khiển phân tán rộng hơn.\u003c\/p\u003e\n\u003ch3\u003eTính năng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChỉ được thiết kế để chứa các mô-đun I\/O S800 dự phòng kép\u003c\/li\u003e\n\u003cli\u003eCấu trúc lắp đặt thanh ray DIN dọc cho các hướng tủ cụ thể\u003c\/li\u003e\n\u003cli\u003eĐơn giản hóa việc định tuyến tín hiệu hiện trường qua các khối đầu cuối tích hợp sẵn\u003c\/li\u003e\n\u003cli\u003eHỗ trợ thay nóng các mô-đun không hoạt động hoặc bị lỗi khi có nguồn điện\u003c\/li\u003e\n\u003cli\u003eNgưỡng hoạt động đã được xác minh lên đến 50V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriển khai Hệ thống Điều khiển Phân tán (DCS) với ABB System 800xA\u003c\/li\u003e\n\u003cli\u003eBộ sản phẩm tự động hóa nhỏ gọn yêu cầu các yếu tố hình thức tiết kiệm không gian\u003c\/li\u003e\n\u003cli\u003eCác vòng quy trình có độ sẵn sàng cao trong các cơ sở hóa dầu, hàng hải và điện lực\u003c\/li\u003e\n\u003cli\u003eCác trạm giám sát an toàn hoặc phụ trợ quan trọng yêu cầu đường dự phòng dự phòng\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông số kỹ thuật kỹ thuật\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTham số\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eThông số kỹ thuật\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhà sản xuất\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMẫu \/ Định danh loại\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE021443R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐơn vị kết thúc mô-đun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐiện áp định mức\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTối đa 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDự phòng I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHỗ trợ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHướng lắp đặt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThanh ray DIN dọc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều sâu \/ chiều dài tịnh sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều cao tịnh sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều rộng tịnh sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186,5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrọng lượng tịnh sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThông tin RoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTheo Chỉ thị EU 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDanh mục WEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Thiết bị nhỏ (Kích thước bên ngoài không quá 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSố lượng pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSố SCIP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7c710169-c950-4bd8-ae0c-d8dba80a0de2 Bulgaria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLắp đặt trên thanh DIN\u003c\/strong\u003e: Gắn chặt cụm vào thanh DIN dọc tiêu chuẩn 35mm. Đảm bảo thanh DIN được nối đất với hệ thống đất của vỏ chính.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHướng tủ\u003c\/strong\u003e: Xác nhận hướng lắp đặt phù hợp với yêu cầu bố trí dọc để đảm bảo luồng không khí đối lưu mặc định quanh các mô-đun vận hành.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThực hành đi dây\u003c\/strong\u003e: Kết thúc cáp trường sử dụng kích thước đầu cos dây phù hợp, chú ý tách riêng các vòng thiết bị điện áp thấp khỏi các đường phân phối điện áp cao liền kề.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXử lý mô-đun\u003c\/strong\u003e: Khi lắp hoặc tháo mô-đun I\/O từ bất kỳ khe nào, hãy dùng lực đều để tránh làm lệch các chân kết nối đa chân trên bo mạch sau.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCâu hỏi thường gặp\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSự khác biệt cốt lõi giữa các bộ kết thúc TU842 và TU843 là gì?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSự khác biệt chính là bố trí lắp đặt vật lý. TU842 được cấu hình để gắn trên thanh DIN ngang, trong khi thiết bị này được thiết kế cấu trúc để lắp trên thanh DIN dọc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMTU này có cần dây nối đất ngoài cách ly không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThiết bị được nối đất qua giá đỡ DIN, tuy nhiên cần tuân theo các thực hành nối đất tủ tiêu chuẩn bằng cách duy trì kết nối trở kháng thấp với tấm lưng chính.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTôi có thể chạy các vòng điều khiển AC 120V tiêu chuẩn trực tiếp qua khối kết thúc này không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKhông, bộ kết thúc này có điện áp kỹ thuật tối đa được đánh giá là 50V. Vượt quá giới hạn này sẽ làm giảm an toàn và các giới hạn vận hành của thiết bị.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCó pin bên trong cần lên lịch bảo trì thay thế không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKhông, bộ kết thúc thụ động này không chứa pin và hoàn toàn dựa vào kiến trúc bus hệ thống bên ngoài để vận hành logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNhững phiên bản nào của nền tảng điều khiển ABB 800xA tương thích với thiết bị này?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNó được liệt kê để tương thích với các phiên bản I\/O S800 4.0, 4.1, 5.0, 5.1 và các thiết lập System 800xA 6.0.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668610511211,"sku":"3BSE021443R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu843-3bse021443r1-compact-product-suite-hardware-selector-yrnn1ujdza1_0bca439e-cd83-4bf3-99f3-a0742d437c85.jpg?v=1765535473"},{"product_id":"abb-tu842-3bse020850r1-s800-i-o-redundant-module-termination-unit","title":"Đơn vị kết thúc mô-đun dự phòng ABB TU842 3BSE020850R1 S800 I\/O","description":"\u003ch3\u003eMô Tả\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTU842\u003c\/strong\u003e là \u003cstrong\u003eBộ Đơn Vị Kết Thúc Mô-đun\u003c\/strong\u003e (MTU) được thiết kế cho hệ thống \u003cstrong\u003eI\/O S800\u003c\/strong\u003e để hỗ trợ cấu hình \u003cstrong\u003eI\/O dự phòng\u003c\/strong\u003e. Nó đóng vai trò là cơ sở giao diện vật lý và điện, cho phép hai mô-đun I\/O S800 tương thích hoạt động theo cặp cho các ứng dụng tự động hóa quy trình có độ sẵn sàng cao. Được thiết kế với điện áp tối đa \u003cstrong\u003e50V\u003c\/strong\u003e, thiết bị này dẫn đường tín hiệu và nguồn điện một cách an toàn đồng thời hỗ trợ \u003cstrong\u003elắp đặt ngang trên thanh ray DIN\u003c\/strong\u003e bên trong tủ điều khiển điện.\u003c\/p\u003e\n\u003ch3\u003eTính Năng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eXây dựng cho việc ghép đôi mô-đun I\/O dự phòng để loại bỏ điểm lỗi đơn lẻ.\u003c\/li\u003e\n\u003cli\u003eĐược đánh giá cho phân phối tín hiệu và nguồn điện tối đa 50V.\u003c\/li\u003e\n\u003cli\u003eThiết kế cho hướng lắp đặt ngang trên thanh ray DIN công nghiệp tiêu chuẩn.\u003c\/li\u003e\n\u003cli\u003eĐơn giản hóa việc kết thúc dây trường để cải thiện khả năng bảo trì hệ thống.\u003c\/li\u003e\n\u003cli\u003eCơ chế khóa tích hợp ngăn chặn việc lắp đặt nhầm các mô-đun I\/O không tương thích.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eỨng Dụng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHệ thống Điều Khiển Phân Tán (DCS) yêu cầu cấu hình độ sẵn sàng cao.\u003c\/li\u003e\n\u003cli\u003eVòng lặp quy trình quan trọng trong nhà máy hóa chất, lọc dầu và xử lý nước.\u003c\/li\u003e\n\u003cli\u003eThiết lập an toàn và điều khiển phụ trợ cho nhà máy phát điện.\u003c\/li\u003e\n\u003cli\u003eHệ thống điều khiển tự động hóa nhà máy sử dụng kiến trúc I\/O S800.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông Số Kỹ Thuật\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTham Số\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eGiá Trị\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhà Sản Xuất\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTên Mẫu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE020850R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBộ Đơn Vị Kết Thúc Mô-đun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTương Thích Hệ Thống\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHệ Thống I\/O S800 (Hệ Thống 800xA 4.0\/4.1\/5.0\/5.1\/6.0, Bộ Sản Phẩm Nhỏ Gọn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCấu Hình I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHỗ Trợ I\/O Dự Phòng\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐánh Giá Điện Áp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐiện Áp Tối Đa 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHướng Lắp Đặt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNgang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMã HS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMã Thuế Quan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều Rộng Tịnh Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều Cao Tịnh Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186,5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều Sâu \/ Dài Tịnh Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrọng Lượng Tịnh Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSố Lượng Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTuân Thủ RoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTheo Chỉ Thị EU 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDanh Mục WEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Thiết Bị Nhỏ (Kích Thước Ngoài Không Quá 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003ch3\u003eLắp đặt trên thanh DIN\u003c\/h3\u003e\n\u003cp\u003eGắn thiết bị ngang trên thanh DIN chuẩn 35 mm loại top-hat. Đảm bảo thanh được nối đất đúng cách với tấm lưng của vỏ để kiểm soát nhiễu điện từ. Bấm chốt khóa chắc chắn vào thanh để tránh di chuyển khi rung.\u003c\/p\u003e\n\u003ch3\u003eĐi dây và cách điện tín hiệu\u003c\/h3\u003e\n\u003cp\u003eXác minh rằng tất cả dây dẫn trường đi đến các kết nối đầu cuối không vượt quá thông số tối đa 50V. Giữ khoảng cách thích hợp giữa cáp tín hiệu điện áp thấp và các đường điện công suất cao trong ống cáp.\u003c\/p\u003e\n\u003ch3\u003eĐối chiếu mô-đun dự phòng\u003c\/h3\u003e\n\u003cp\u003eKhi lắp mô-đun vào hai khe của bộ phận cơ sở, đảm bảo cả hai thành phần có cùng số model và phiên bản firmware để duy trì đồng bộ và chức năng chuyển đổi dự phòng đúng cách.\u003c\/p\u003e\n\u003ch3\u003eTản nhiệt\u003c\/h3\u003e\n\u003cp\u003eGiữ khoảng trống thích hợp phía trên và dưới bộ phận cơ sở được lắp ngang. Khoảng cách phù hợp ngăn ngừa các túi khí nóng ứ đọng và đảm bảo đối lưu tự nhiên đủ qua vỏ mô-đun.\u003c\/p\u003e\n\u003ch3\u003eCâu hỏi thường gặp\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMục đích chính của bộ phận cơ sở TU842 là gì?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNó cung cấp các điểm kết nối điện chung và khe gắn cơ học cần thiết để vận hành hai mô-đun S800 I\/O trong cấu hình dự phòng.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eĐiện áp hoạt động tối đa mà bộ phận đầu cuối này hỗ trợ là bao nhiêu?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThiết bị được chỉ định điện áp hoạt động tối đa là 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThiết bị này có thể được gắn dọc trên thanh DIN không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKhông, bộ phận đầu cuối mô-đun này được thiết kế riêng cho việc gắn ngang trên thanh DIN.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSản phẩm này có tích hợp pin không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKhông, thiết bị không chứa pin và hoàn toàn phụ thuộc vào nguồn điện hệ thống bên ngoài.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKiến trúc điều khiển ABB nào hỗ trợ thiết bị này?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNó hoàn toàn tương thích với các phiên bản ABB System 800xA từ 4.0 đến 6.0 và Bộ Sản Phẩm Compact chạy các mô-đun S800 I\/O.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668610871659,"sku":"3BSE020850R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu842-3bse020850r1-redundant-module-termination-unit-5vorksgfbzz_39676cee-c90a-47a9-b5a3-6ee7289098f7.jpg?v=1765535487"},{"product_id":"abb-tu811v1-3bse013231r1-s800-i-o-compact-module-termination-unit","title":"Đơn vị kết thúc mô-đun ABB TU811V1 3BSE013231R1 S800 I\/O Compact","description":"\u003cp style=\"font-size: 14px; color: #2d3748; line-height: 1.6; margin-top: 0; margin-bottom: 20px;\"\u003e\n  ABB TU811V1 là một đơn vị kết thúc mô-đun nhỏ gọn được thiết kế cho nền tảng \u003cstrong\u003ehệ thống S800 I\/O\u003c\/strong\u003e để quản lý các đường tín hiệu trường trong kiến trúc điều khiển phân tán. Thành phần giao diện công nghiệp này hỗ trợ liên kết điện điểm-điểm, sử dụng \u003cstrong\u003ecấu hình đầu cuối tín hiệu 1x8\u003c\/strong\u003e được đánh giá cho giới hạn hoạt động lên đến \u003cstrong\u003e250V\u003c\/strong\u003e. Được chỉ định bởi mã sản phẩm (số đặt hàng) \u003cstrong\u003e3BSE013231R1\u003c\/strong\u003e và Ký Hiệu Loại \u003cstrong\u003eTU811V1\u003c\/strong\u003e, nền tảng phần cứng nhỏ gọn này dẫn các tín hiệu trường thụ động hoặc chủ động an toàn vào các mô-đun xử lý trong các nhà máy sản xuất liên tục. Được chế tạo không có pin bên trong, thiết kế khoảng cách thấp của nó cho phép tích hợp dưới giá đỡ mật độ cao, ngăn ngừa lỗi đi dây phức tạp, bảo vệ liên kết dữ liệu khỏi nhiễu điện từ lưới điện và ổn định đồng bộ dữ liệu công nghiệp.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eTính Năng\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px; padding-left: 20px; list-style-type: square; font-size: 14px; color: #2d3748; line-height: 1.6;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eBố trí phần cứng nhỏ gọn với nhóm đầu cuối tín hiệu 1x8 tập trung cho việc đi dây dẫn trường sạch sẽ.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCấu hình mạch điện áp cao được công nhận chính thức với giới hạn phân phối tối đa 250V.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eThiết kế linh kiện không pin giảm công việc theo dõi bảo trì phòng ngừa và thay thế tại hiện trường.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eTuân thủ Chỉ thị RoHS của Châu Âu 2011\/65\/EU và được phân loại theo hướng dẫn thiết bị nhỏ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eỨng Dụng\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px; padding-left: 20px; list-style-type: square; font-size: 14px; color: #2d3748; line-height: 1.6;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCác nút điều khiển phân tán S800 I\/O và System 800xA xử lý các vòng tự động hóa trường đa kênh.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eAdvant OCS với giao diện fieldbus Master SW hoặc MOD 300 SW.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eBộ sản phẩm nhỏ gọn dành cho môi trường trường yêu cầu cấu hình đầu cuối mật độ cao cách ly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eThông Tin Đặt Hàng\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 25px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 40%;\"\u003eTham Số Đặt Hàng\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 60%;\"\u003eGiá Trị\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eMã Sản Phẩm (Số Đặt Hàng)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e3BSE013231R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eKý Hiệu Loại ABB\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTU811V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eSố Biểu Thuế Hải Quan\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e85371098\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eMã HS\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e853710 - Bảng mạch, bảng điều khiển, bàn điều khiển, tủ cho điều khiển điện (điện áp không vượt quá 11000 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eThông số kỹ thuật kỹ thuật\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 25px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 40%;\"\u003eThông số kỹ thuật\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d; border: 1px solid #e2e8f0; width: 60%;\"\u003eDữ liệu đặc tả\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eNhà sản xuất\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eLoại sản phẩm\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eĐơn vị kết thúc mô-đun (MTU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eCấu hình đầu cuối\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eĐầu cuối tín hiệu 1x8\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eĐiện áp định mức\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e250V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eChiều rộng tịnh sản phẩm\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e58,5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eChiều cao tịnh sản phẩm\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e170 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eChiều sâu \/ chiều dài tịnh sản phẩm\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e64 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eTrọng lượng tịnh sản phẩm\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0,2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eSố lượng pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eHồ sơ môi trường RoHS\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTuân theo Chỉ thị EU 2011\/65\/EU\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eDanh mục thiết bị WEEE\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e5. Thiết bị nhỏ (Không có kích thước bên ngoài nào vượt quá 50 cm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eSự hiện diện SVHC\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eKhông có SVHC (Bulgaria)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eNước sản xuất\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eThụy Điển\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fcfcfc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eTrọng lượng vận chuyển (tính toán)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0,35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eKích thước bao bì (tính toán)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e190 mm x 85 mm x 75 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; font-size: 18px; border-bottom: 2px solid #e2e8f0; padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px;\"\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #2d3748; margin-bottom: 20px; line-height: 1.6;\"\u003e\n  Để tránh các vòng xử lý không ổn định hoặc hư hại điện áp tức thời cho các mô-đun I\/O S800 được kết nối, hãy tuân thủ các trình tự thực hiện công nghiệp cụ thể.\n\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #e53e3e; padding: 12px 15px; margin-bottom: 20px; border-radius: 0 4px 4px 0;\"\u003e\n  \u003cdiv style=\"color: #c53030; font-weight: bold; margin-bottom: 5px; font-size: 13px; letter-spacing: 0.5px;\"\u003e\n    CẢNH BÁO QUAN TRỌNG: CẦN CÁCH LY NĂNG LƯỢNG\n  \u003c\/div\u003e\n  \u003cdiv style=\"font-size: 13px; color: #742a2a; line-height: 1.5;\"\u003e\n    Xác minh rằng tất cả các đường cấp nguồn vào, vòng lặp thiết bị trường và lưới điện phụ kết nối với bảng mạch sau đều được ngắt hoàn toàn trước khi bắt đầu thao tác lắp ráp. Xử lý các thành phần trên khung hoạt động có thể gây ra hồ quang tạm thời cao hoặc hư hại vật lý cho nhà máy.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin: 20px 0;\"\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eXác minh điều kiện khóa thiết bị\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eXác nhận rằng các giá đỡ đầu cuối mục tiêu không có điện và sử dụng thiết bị kiểm tra đã hiệu chuẩn để xác minh trạng thái không có năng lượng trước khi lắp ráp.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eCố định phần cứng vào thanh ray DIN tiêu chuẩn\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eCăn chỉnh các kênh gắn phía sau với thanh ray DIN của khung phụ và ấn xuống cho đến khi các kẹp tiếp đất cơ học kêu \"cạch\" chắc chắn vào đường dẫn kim loại.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"position: relative; padding-left: 35px; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"position: absolute; left: 0; top: 2px; background-color: #2b6cb0; color: #ffffff; width: 22px; height: 22px; border-radius: 50%; text-align: center; font-size: 12px; font-weight: bold; line-height: 22px;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"font-size: 14px; line-height: 1.5;\"\u003e\n      \u003cdiv style=\"font-weight: bold; color: #1a365d; margin-bottom: 3px;\"\u003eĐấu dây dẫn trường vào các hàng đầu cuối\u003c\/div\u003e\n      \u003cdiv style=\"color: #2d3748; font-size: 13px;\"\u003eTách dây tín hiệu trường theo đúng chiều dài quy định, lần lượt cắm vào các khối đầu cuối 1x8 và khóa chặt kẹp giữ đầu cuối.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613656939,"sku":"TU811V1 3BSE013231R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu811v1-3bse013231r1-process-automation-module-0jopisj0p2w_dfad0978-5e61-48a8-b70a-dce49ff14e6c.jpg?v=1765535584"},{"product_id":"abb-tu818-3bse069209r1-s800-i-o-compact-module-termination-unit","title":"ABB TU818 3BSE069209R1 S800 I\/O Compact Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU818\u003c\/strong\u003e (\u003cstrong\u003e3BSE069209R1\u003c\/strong\u003e) is an \u003cstrong\u003eOriginal New\u003c\/strong\u003e compact module termination unit (MTU) designed for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e distributed hardware platform by \u003cstrong\u003eABB\u003c\/strong\u003e. This passive base unit bridges field wiring and plug-in electronic I\/O modules, accommodating a signal density of up to 1x32 or 2x16 independent terminal channels rated for an operational threshold of 50V. The unit establishes direct data bus backplane routing and localized power distribution links, eliminating separate external marshaling panels. It ensures broad cross-system integration across diverse control environments, providing backward and native hardware compatibility with \u003cstrong\u003e800xA\u003c\/strong\u003e, \u003cstrong\u003eAdvant OCS with Master SW\u003c\/strong\u003e, \u003cstrong\u003eAdvant OCS with MOD 300 SW\u003c\/strong\u003e, and the \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e. Built for reliable deployment within modern fieldbus architectures, the component facilitates simple modular maintenance cycles and high signal integrity for mixed analog and discrete process applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures high-density signal integration providing 1x32 and 2x16 terminal layout arrangements.\u003c\/li\u003e\n\u003cli\u003eCompact baseline form factor reduces physical footprint requirements within electrical control cabinets.\u003c\/li\u003e\n\u003cli\u003eSupports up to 50V field voltage distribution across active process channels.\u003c\/li\u003e\n\u003cli\u003eDesigned for passive operational longevity without specialized internal battery backups.\u003c\/li\u003e\n\u003cli\u003eEngineered for rapid plug-in insertion and removal of S800 I\/O electronic modules during lifecycle servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e remote sub-rack architectures utilized in distributed control system (DCS) nodes.\u003c\/li\u003e\n\u003cli\u003eProcess machinery interfaces inside thermal power utilities, marine platforms, and chemical treatment loops.\u003c\/li\u003e\n\u003cli\u003eFactory floor fieldbus control systems incorporating Advant Fieldbus 100 networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 57.9173%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eTU818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e3BSE069209R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eTU818 Compact MTU, 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eSignal Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e1x32 (and 2x16) signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eMaximum Rated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.7589%;\"\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.9173%;\"\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail Installation\u003c\/h3\u003e\n\u003cp\u003eMount the termination unit onto standard 35 mm DIN rail profiles. Ensure the integrated grounding clips on the rear frame seat fully against clean, unpainted metallic tracks to achieve reliable instrument ground connection.\u003c\/p\u003e\n\u003ch3\u003eModule Attachment\u003c\/h3\u003e\n\u003cp\u003eAlign the mating interface slots of the designated S800 I\/O electronic module with the base unit housing. Insert smoothly perpendicular to the rail until the latching tabs snap into position. Do not force alignment pins if resistance occurs.\u003c\/p\u003e\n\u003ch3\u003eCable Routing and Wire Stripping\u003c\/h3\u003e\n\u003cp\u003eStrip the field signal cabling insulation according to the specified wire gauge tolerances for S800 termination blocks. Route external field lines through dedicated lower wire trays, keeping low-voltage signal runs separated from high-capacity power lines to prevent signal cross-talk.\u003c\/p\u003e\n\u003ch3\u003eMoisture Protection\u003c\/h3\u003e\n\u003cp\u003eVerify the operational enclosure maintains structural ingress integrity against moisture accumulation and ambient dust. Ensure continuous environmental controls prevent moisture condensation inside the termination housing.\u003c\/p\u003e\n\u003ch3\u003eShielding Continuity\u003c\/h3\u003e\n\u003cp\u003eTerminate incoming field instrument cable shields at the dedicated ground bars positioned within the terminal assembly area to maintain low impedance pathways for electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEU Directive 2011\/65\/EU (RoHS)\u003c\/li\u003e\n\u003cli\u003eSVHC Status: No SVHC present per Bulgarian registry data (SCIP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the voltage limit specification for this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe termination unit is officially rated to handle field distribution voltages not exceeding 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many signal lines can be terminated onto a single base block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accommodates configurations of either 1x32 terminal arrangements or 2x16 split terminal pathways.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this MTU require internal batteries to preserve operational data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is a passive structural interconnection interface that contains 0 batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O series is this base architecture designed for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is built specifically to host the ABB S800 I\/O hardware component series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be integrated into legacy Advant OCS architectures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully compatible with Advant OCS with Master SW and Advant OCS with MOD 300 SW systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical width of this module for cabinet layout calculations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe structural net width of the termination framework is precisely 58.5 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical ground continuity established for the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding path connectivity is automatically completed via integrated spring clips contacting the standard DIN rail system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be done if the internal S800 I\/O module needs replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDe-energize local loop channels and release the module mounting locks to pull the device straight out without dismantling field wires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 85371098 Customs Tariff Number refer to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis identifier classifies the asset as an electrical control or distribution board, console, panel, or base assembly rated under 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the termination block feature conformal coating variations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit corresponds to the standard catalog specification layout; specific environment variants should refer to specific suffix lists.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613853547,"sku":"3BSE069209R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu818v1-3bse069209r1-compact-module-termination-unit-bkoxqvrdkg3_6f8a04f9-10f4-41bd-92ef-6400f2c39e31.jpg?v=1765535590"},{"product_id":"abb-tu846-3bse022460r1-s800-i-o-module-termination-unit","title":"ABB TU846 3BSE022460R1 S800 I\/O Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU846\u003c\/strong\u003e is a \u003cstrong\u003eModule Termination Unit\u003c\/strong\u003e (MTU) designed for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system. It provides the physical housing, electrical connections, and termination points for two \u003cstrong\u003eCI840\u003c\/strong\u003e Fieldbus Communication Interfaces in a \u003cstrong\u003e1+1 redundant\u003c\/strong\u003e configuration. This unit enables \u003cstrong\u003eredundant I\/O\u003c\/strong\u003e capabilities and is engineered for \u003cstrong\u003evertical mounting\u003c\/strong\u003e within control cabinets to optimize space and thermal management. The unit distributes power and internal Modulebus signals to the hosted communication modules while maintaining complete electrical isolation and signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports dual \u003cstrong\u003eCI840\u003c\/strong\u003e modules for fully redundant fieldbus communication.\u003c\/li\u003e\n\u003cli\u003eDesigned for vertical DIN-rail mounting to facilitate efficient cabinet layout.\u003c\/li\u003e\n\u003cli\u003eIncludes one dedicated power supply connector for secure input distribution.\u003c\/li\u003e\n\u003cli\u003eEquipped with two \u003cstrong\u003eTB807\u003c\/strong\u003e Modulebus Terminators to ensure correct bus impedance.\u003c\/li\u003e\n\u003cli\u003eBuilt-in mechanical keying prevents the insertion of incorrect module types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) and Programmable Logic Controllers (PLC).\u003c\/li\u003e\n\u003cli\u003eProcess automation industries including oil and gas, chemical, and water treatment.\u003c\/li\u003e\n\u003cli\u003eHigh-availability power generation and electrical distribution control systems.\u003c\/li\u003e\n\u003cli\u003eFactory automation environments requiring redundant I\/O infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE022460R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O System (System 800xA 4.0\/4.1\/5.0\/5.1\/6.0, Compact Product Suite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1+1 CI840 Fieldbus Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Power Supply Connector, 2 x TB807 Modulebus Terminators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDIN Rail Installation\u003c\/h3\u003e\n\u003cp\u003eMount the termination unit vertically onto a standard 35 mm DIN rail. Ensure the rail is properly grounded to the cabinet enclosure. Engage the top DIN rail clip first, then press the lower portion of the unit firmly against the rail until the locking mechanism clicks into place.\u003c\/p\u003e\n\u003ch3\u003ePower Connection\u003c\/h3\u003e\n\u003cp\u003eConnect the system power supply using the included power supply connector block. Verify that the input voltage complies with the requirements of the hosted communication modules before energizing the circuit. Ensure proper polarity is maintained to prevent component damage.\u003c\/p\u003e\n\u003ch3\u003eModulebus Termination\u003c\/h3\u003e\n\u003cp\u003eThe two included \u003cstrong\u003eTB807\u003c\/strong\u003e Modulebus Terminators must be installed at the designated ends of the internal bus segment. Correct termination is required to eliminate signal reflections and maintain reliable communication across the S800 I\/O structure.\u003c\/p\u003e\n\u003ch3\u003eCooling and Ventilation\u003c\/h3\u003e\n\u003cp\u003eMaintain adequate clearance above and below the vertically mounted unit to allow natural convective airflow. Do not block the ventilation paths of the hosted modules, as proper thermal dissipation prevents localized overheating.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TU846 unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as a physical base and electrical interface that supports two fieldbus communication modules in a redundant configuration for the S800 I\/O system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module termination unit come with the necessary terminators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the package includes two TB807 Modulebus Terminators along with one power supply connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be mounted horizontally on a DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is designed exclusively for vertical mounting to ensure proper module alignment and optimal heat dissipation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich specific communication module is compatible with this MTU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is explicitly designed to host the CI840 Fieldbus Communication Interface in a 1+1 redundant setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any special tool required to secure the power supply connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard industrial screwdrivers matching the terminal block screws are sufficient to secure the incoming power wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control systems support this equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with ABB System 800xA (versions 4.0 through 6.0) and the Compact Product Suite utilizing S800 I\/O.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668617195883,"sku":"3BSE022460R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu846-3bse022460r1-module-termination-unit-s5vgviwm0sq_7ee41948-f260-41f2-bc09-d74e1f57e505.jpg?v=1765535714"},{"product_id":"abb-3bse021447r1-tu845-s800-i-o-redundant-module-termination-unit","title":"ABB 3BSE021447R1 TU845 S800 I\/O Redundant Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE021447R1 TU845\u003c\/strong\u003e is a dedicated \u003cstrong\u003eModule Termination Unit\u003c\/strong\u003e (MTU) designed for high-availability configurations within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system platform. Engineered to support redundant input\/output operational structures, this base infrastructure element provides physical housing and electrical routing connections for dual redundant I\/O modules. The unit operates safely within a maximum working voltage threshold of 50V, making it highly suitable for low-voltage signal transmission loops. By routing signals through a structured backplane configuration, the \u003cstrong\u003e3BSE021447R1\u003c\/strong\u003e enables concurrent dual-channel module connections to preserve continuous data acquisition and system control even during individual module diagnostics or field replacements. This structural solution seamlessly bridges field instrumentation wiring directly into distributed automation networks monitored by plant DCS architectures like the \u003cstrong\u003e800xA\u003c\/strong\u003e or \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in support for dual redundant I\/O module assemblies to enable fail-safe process monitoring loops.\u003c\/li\u003e\n\u003cli\u003eRated for low-voltage signal deployment handling a maximum system rating of 50V.\u003c\/li\u003e\n\u003cli\u003eIntegrated vertical DIN rail mounting framework optimized to maximize internal layout density inside industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003ePass-through terminal interface layout enabling convenient connection of multi-channel field sensors and actuator signal wiring.\u003c\/li\u003e\n\u003cli\u003eComponent space allocation designed to operate without the pre-installation of an integrated shunt stick accessory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant analog or digital field signal termination within \u003cstrong\u003e800xA\u003c\/strong\u003e distributed control system process nodes.\u003c\/li\u003e\n\u003cli\u003eHigh-density field wiring networks in continuous chemical plant processes, petroleum extraction plants, and petrochemical distribution hubs.\u003c\/li\u003e\n\u003cli\u003eFail-safe safety and automation sub-loops in municipal clean water networks and industrial pumping stations.\u003c\/li\u003e\n\u003cli\u003eMulti-channel instrumentation routing for critical power plant auxiliary control setups and boiler management architectures.\u003c\/li\u003e\n\u003cli\u003eDistributed tracking assets deployed within heavy-duty manufacturing equipment managed by the \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eOrdering Information must be strictly evidence-based; if not explicitly present in source, omit entirely without explanation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 466.251px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"1\" style=\"width: 26.61%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"2\" style=\"width: 26.61%; height: 19.5938px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"3\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct ID\u003c\/td\u003e\n\u003ctd data-row=\"3\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e3BSE021447R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"4\" style=\"width: 26.61%; height: 19.5938px;\"\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd data-row=\"4\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eTU845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"5\" style=\"width: 26.61%; height: 19.5938px;\"\u003eCatalog Description\u003c\/td\u003e\n\u003ctd data-row=\"5\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eTU845 Redundant MTU, 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd data-row=\"6\" style=\"width: 26.61%; height: 39.1875px;\"\u003eLong Description\u003c\/td\u003e\n\u003ctd data-row=\"6\" style=\"width: 70.5329%; height: 39.1875px;\"\u003eUsed with redundant I\/O. Vertical DIN rail mounting. Shunt Stick not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"7\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"7\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eModule_Termination_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"8\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"8\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eS800 I\/O (S800 I\/O 4.0 \/ 4.1 \/ 5.0 \/ 5.1 \/ 6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"9\" style=\"width: 26.61%; height: 19.5938px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"9\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e800xA System, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"10\" style=\"width: 26.61%; height: 19.5938px;\"\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eMaximum 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"11\" style=\"width: 26.61%; height: 19.5938px;\"\u003eRedundancy Capability\u003c\/td\u003e\n\u003ctd data-row=\"11\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eSupported (Used with redundant I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"12\" style=\"width: 26.61%; height: 19.5938px;\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd data-row=\"12\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"13\" style=\"width: 26.61%; height: 19.5938px;\"\u003eShunt Stick Included\u003c\/td\u003e\n\u003ctd data-row=\"13\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.5938px;\"\u003e\n\u003ctd data-row=\"14\" style=\"width: 26.61%; height: 15.5938px;\"\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd data-row=\"14\" style=\"width: 70.5329%; height: 15.5938px;\"\u003e186.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"15\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd data-row=\"15\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd data-row=\"16\" style=\"width: 26.61%; height: 39.1875px;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd data-row=\"16\" style=\"width: 70.5329%; height: 39.1875px;\"\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"17\" style=\"width: 26.61%; height: 19.5938px;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd data-row=\"17\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"18\" style=\"width: 26.61%; height: 19.5938px;\"\u003eNumber of Batteries\u003c\/td\u003e\n\u003ctd data-row=\"18\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"19\" style=\"width: 26.61%; height: 19.5938px;\"\u003eRoHS Information\u003c\/td\u003e\n\u003ctd data-row=\"19\" style=\"width: 70.5329%; height: 19.5938px;\"\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"20\" style=\"width: 26.61%; height: 19.5938px;\"\u003eWEEE Category\u003c\/td\u003e\n\u003ctd data-row=\"20\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"21\" style=\"width: 26.61%; height: 19.5938px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd data-row=\"21\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd data-row=\"22\" style=\"width: 26.61%; height: 19.5938px;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd data-row=\"22\" style=\"width: 70.5329%; height: 19.5938px;\"\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eTerminal \/ Connection Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDual Module Slots\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBuilt-in matching interfaces providing concurrent electrical links for redundant I\/O module pairs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBase Wire Terminals\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStructured physical wire termination points for external instrumentation inputs and control loop paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Mount the hardware module framework strictly in a vertical orientation onto a standard 35 mm industrial DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Verification:\u003c\/strong\u003e Ensure that any required external shunt stick devices are sourced separately before commencing full loop integration, as they are not pre-packaged with the base unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Constraints Check:\u003c\/strong\u003e Verify that the connected signal loops and auxiliary power sources do not exceed the absolute operational specification ceiling of 50V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Spacing:\u003c\/strong\u003e Arrange adjacent components inside the electrical cabinet to properly accommodate the unit's net height of 124 mm and width of 186.5 mm, ensuring adequate airflow and routing clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Alignment:\u003c\/strong\u003e Seat both the primary and secondary I\/O modules firmly into their designated base slots to guarantee complete channel coupling and continuous circuit tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary technical use of this termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is designed to provide structural termination and signal routing paths for dual redundant module setups within the S800 I\/O product line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this specific product arrive with an integrated shunt stick included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the tracking data explicitly confirms that the shunt stick component is not included and must be provided separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the absolute maximum working voltage defined for this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is rated to manage low-voltage signal transmission loops running up to a maximum parameter of 50V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this particular unit physically positioned and fixed inside a cabinet enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module termination unit is explicitly configured for vertical mounting onto standard industrial DIN rail tracks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich primary distributed automation architectures are fully compatible with this component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is natively matched with ABB 800xA and Compact Product Suite platforms utilizing S800 I\/O variations from version 4.0 through 6.0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the exact physical net weight of this standalone termination base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe baseline equipment has an individual net hardware weight of exactly 0.6 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any toxic internal battery sub-assemblies inside this hardware structure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the unit is constructed with zero internal batteries, minimizing hazardous waste and simplified disposal processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical outline metrics for panel layout planning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe structural housing tracks at a width of 186.5 mm, a height of 124 mm, and a net thickness depth of 64 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat structural commodity code governs international customs shipping for this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe verified global tariff index records this equipment under Customs Tariff Number 85371098 and HS Code 853710.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware follow European environmental substance restrictions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the manufacturing guidelines comply fully with the parameters set forth in EU RoHS Directive 2011\/65\/EU.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668618080619,"sku":"ABB TU845 3BSE021447R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu845-3bse021447r1-redundant-termination-unit-4ucdhdk4koj_ed1bbdaa-0c31-4e5e-be18-9e3d9c2034e3.jpg?v=1765535749"},{"product_id":"abb-3bsc690075r1-tu890-s800-i-o-module-termination-unit","title":"ABB 3BSC690075R1 TU890 S800 I\/O Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU890\u003c\/strong\u003e is a specialized Module Termination Unit (MTU) configured for the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system, offering a dedicated \u003cstrong\u003eIntrinsic Safety (IS) interface\u003c\/strong\u003e for hazardous area deployments. This critical hardware unit provides 3x9 signal terminals for efficient field wiring routing while isolating safe-area circuitry from potentially explosive environments. By establishing a structurally sound connection layer for companion I\/O blocks, it forms the underlying framework for localized distributed marshalling loops.\u003c\/p\u003e\n\u003cp\u003eThe assembly includes an integrated physical \u003cstrong\u003ewiring separator\u003c\/strong\u003e designed to enforce correct physical clearance gaps between intrinsically safe loops and non-IS conductors. This component is highly compatible across a broad spectrum of \u003cstrong\u003eABB\u003c\/strong\u003e controller segments, including the \u003cstrong\u003eSystem 800xA\u003c\/strong\u003e (versions 4.0 through 6.0), \u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e, and legacy platforms like \u003cstrong\u003eAdvant OCS with Master SW\u003c\/strong\u003e or \u003cstrong\u003eMOD 300 SW\u003c\/strong\u003e. Its compact footprint ensures strict conformity to industrial spacing metrics within local sub-distribution and power cabinets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModule Termination Unit integrated with an Intrinsic Safety (IS) interface topology\u003c\/li\u003e\n\u003cli\u003eConfigured with 3x9 signal terminals for precise field wire allocation\u003c\/li\u003e\n\u003cli\u003eIncludes an engineering-grade physical wiring separator to preserve field segment isolation\u003c\/li\u003e\n\u003cli\u003eDirect-fit mechanical alignment for a wide range of S800 I\/O module families\u003c\/li\u003e\n\u003cli\u003eCompact configuration suitable for dense panel cabinet setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHazardous environment field instrument termination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem 800xA\u003c\/strong\u003e distributed control architectures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Product Suite\u003c\/strong\u003e I\/O marshalling assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvant Fieldbus 100\u003c\/strong\u003e remote network nodes\u003c\/li\u003e\n\u003cli\u003ePetrochemical, refining, and gas processing control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSC690075R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3x9 signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiring separator included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e194 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCIP Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo SVHC present Singapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e The included physical wiring separator must remain correctly positioned during installation. Maintain strict physical separation distances between intrinsically safe and non-intrinsically safe cabling runs inside the cable ducts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail and Mechanical Mounting:\u003c\/strong\u003e Mount the unit firmly onto standard grounding rails, confirming that all rear locking latches engage properly to absorb engine room vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Utilize standardized anti-static field gear, including an ESD wrist strap, prior to clicking the active S800 I\/O modules into the termination base socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Assignment Execution:\u003c\/strong\u003e Wire field signals strictly in compliance with the 3x9 designated terminal layout schema to ensure proper instrument power and loop-back mapping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core engineering purpose of this specific termination unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit provides a secure, physical connection base for standard S800 modules while establishing an Intrinsic Safety interface boundary for wiring operating in hazardous industrial locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat function does the integrated wiring separator fulfill?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe wiring separator forms an explicit physical isolation barrier between adjacent wire groupings, ensuring high-voltage noise or non-IS loops cannot inadvertently bridge into isolated circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this hardware base backward compatible with older Advant OCS distributed platforms?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is formally documented as compatible with Advant OCS with Master SW and Advant OCS with MOD 300 SW configurations utilizing standard S800 footprints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this termination framework contain internal backup batteries or charge cells?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is a passive structural interface and contains exactly zero internal batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensional values required for internal enclosure mapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit measures 194 mm in height, 58.5 mm in width, and 64 mm in depth, with a net standalone hardware mass of 0.3 kg.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668626796907,"sku":"3BSC690075R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tu890-3bsc690075r1-module-termination-unit-e2lcp2rygkh_b5ec7a0a-76d7-4004-9f32-c816d9b4903c.jpg?v=1765536011"},{"product_id":"abb-sdcs-iob-23-kit-c-64349708-acs800-digital-connection-board","title":"ABB SDCS-IOB-23 KIT\/C (64349708) ACS800 Digital Connection Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ABB SDCS-IOB-23 KIT\/C is a high-integrity discrete interface assembly engineered for variable speed motor controls and electrical distribution cabinets within the ACS800-X04 system portfolio. Operating as a specialized \u003cstrong\u003edigital connection board\u003c\/strong\u003e rated for 230V applications, this hardware assembly delivers reliable galvanic isolation and signal conditioning between the primary controller electronics and external field contact circuits.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nTo maintain stable runtime data tracking in severe industrial layouts, the \u003cstrong\u003eSDCS-IOB-23 KIT\/C\u003c\/strong\u003e features an advanced protective \u003cstrong\u003ecoated\u003c\/strong\u003e circuit architecture that shields components from airborne particulate layout drift and humidity. This comprehensive component kit includes a heavy-duty \u003cstrong\u003e3 meter interface cable\u003c\/strong\u003e, allowing for immediate deployment and flexible installation inside separate low-voltage control cubicles. The robust tracking design minimizes binary transmission latency, ensuring continuous logic protection and interlocking safety.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e230V Discrete Interfacing\u003c\/strong\u003e: Engineered explicitly to route high-voltage digital inputs and status interlocks securely without auxiliary step-down hardware.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCoated Circuit Insulation\u003c\/strong\u003e: Equipped with a specialized protective surface coating to resist conductive dust, environmental moisture, and harsh factory chemistry.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eExtended 3 Meter Cable Assembly\u003c\/strong\u003e: Supplied with a factory-tested 3 meter shielded wiring bundle to facilitate remote control box mounting away from localized electromagnetic paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-voltage discrete signal translation, tracking, and remote safety interlocking within ABB ACS800-X04 industrial converter modules.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy industrial plants including metal machining centers, continuous chemical refinement plants, and mineral processing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSDCS-IOB-23 KIT\/C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct ID \/ Order Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e64349708\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eABB Type Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDigital connection board, 230V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Main Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACS800-X04\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVoltage Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e230V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3 meter cable \/ Coated board version\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCN8 Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85049099\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85049090\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Type Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eOriginal \/ New\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFinland (FI)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e320 mm x 240 mm x 85 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0;\"\u003e\n    CRITICAL WARNING: 230V ELECTROCUTION HAZARD\n  \u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003e\n    Isolate, switch off, and lock out all primary and auxiliary 230V control potential voltages feeding this interface terminal grid before starting work. Drive bus capacitors store hazardous potential voltages after main terminal breaks. Wait at least 15 minutes for safety discharge paths to actuate, and use a certified voltmeter to confirm a completely dead electrical state before touching trace layouts or wiring connectors.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003eFasten a verified static control strip to your arm and clamp the terminal onto an unpainted grounded frame element to safely ground body static charges.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003eRoute the bundled 3 meter interface cable entirely through the low-voltage wire trays, maintaining strict physical separation from three-phase armature lines to eliminate induction noise.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003eMount the board into the designated control slot tracking points, torque down all frame screws evenly to guarantee proper structure ground contact, and lock down the cable harness connectors.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955391851,"sku":"SDCS-IOB-23 KIT\/C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse005178r1-2yatpyd3hd1_1bbf7ca6-18f3-4299-94c0-b38c76734eef.jpg?v=1766478057"},{"product_id":"abb-ai845-3bse023675r1-s800-i-o-analog-input-module","title":"Module đầu vào tương tự ABB AI845 3BSE023675R1 S800 I\/O","description":"\u003ch3\u003eMô tả\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAI845\u003c\/strong\u003e với mã sản phẩm \u003cstrong\u003e3BSE023675R1\u003c\/strong\u003e là mô-đun đầu vào analog 8 kênh thiết kế cho kiến trúc hệ thống phân tán S800 I\/O. Thiết bị phần cứng này kết nối tín hiệu dòng điện tiêu chuẩn 0 đến 20 mA hoặc 4 đến 20 mA từ các bộ truyền trường trực tiếp đến bộ điều khiển trung tâm. Nó tích hợp khả năng định tuyến HART riêng biệt cho từng kênh, cho phép giao tiếp hai chiều với các thiết bị thông minh qua các vòng analog hiện có mà không làm thay đổi việc truyền biến quy trình thông thường. Nó cung cấp tùy chọn dự phòng phần cứng hai kênh khi kết hợp với các đơn vị đầu cuối phù hợp, duy trì đường tín hiệu hoạt động và độ sẵn sàng hệ thống trong trường hợp lỗi một mô-đun.\u003c\/p\u003e\n\u003ch3\u003eTính năng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCung cấp 8 kênh đầu vào theo dõi dòng điện đơn cuối hỗ trợ tín hiệu 0 đến 20 mA hoặc 4 đến 20 mA.\u003c\/li\u003e\n\u003cli\u003eTích hợp truyền thông HART qua từng kênh cho hệ thống quản lý tài sản.\u003c\/li\u003e\n\u003cli\u003eHỗ trợ thay nóng và cấu hình dự phòng hoàn toàn để thu thập dữ liệu quy trình liên tục.\u003c\/li\u003e\n\u003cli\u003eTính năng các quy trình chẩn đoán tích hợp để giám sát mạch hở và trạng thái tín hiệu vượt ngưỡng.\u003c\/li\u003e\n\u003cli\u003eSử dụng thiết lập kết thúc điện nhỏ gọn với các Đơn vị Kết Thúc Mô-đun S800 tiêu chuẩn.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTruyền dữ liệu vòng quy trình có độ sẵn sàng cao trong các đơn vị lọc hóa dầu và phát điện.\u003c\/li\u003e\n\u003cli\u003eLiên kết giao diện chịu lỗi kép kết nối các tham số an toàn với hệ thống điều khiển phân tán.\u003c\/li\u003e\n\u003cli\u003eTích hợp quản lý tài sản sử dụng giao thức định vị chẩn đoán HART từ xa.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông số kỹ thuật\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eThông số\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eGiá trị\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhà sản xuất\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMẫu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMã sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE023675R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDòng sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMô-đun đầu vào analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSố lượng kênh\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kênh đơn cuối (hỗ trợ dự phòng)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDải đầu vào\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 đến 20 mA \/ 4 đến 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrở kháng đầu vào\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐộ phân giải\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChuyển đổi A\/D 12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHỗ trợ giao thức HART\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCó, truyền qua từng kênh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYêu cầu nguồn điện\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTiêu thụ nội bộ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCấp độ bảo vệ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhiệt độ hoạt động\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 đến +55 độ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhiệt độ lưu trữ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 đến +70 độ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNước sản xuất\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThụy Điển (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrọng lượng\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eKết nối\/Giao diện\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eChân đầu cuối\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChức năng\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 1 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 2 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 3 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 4 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 5 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 6 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 7 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu đầu vào kênh 8 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9 đến 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTín hiệu trả về kênh \/ Đất chung (0V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLắp đặt trên bản đế\u003c\/strong\u003e: Xác nhận rằng Bộ Kết Thúc Mô-đun (như TU844 hoặc TU845) đã được cố định trên thanh DIN trước khi gắn thân mô-đun. Ngắt nguồn điện chính, căn chỉnh các chốt nhựa dẫn hướng và dùng lực thẳng đứng đều cho đến khi các chốt giữ bên kêu tiếng “click”.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGiao thức che chắn\u003c\/strong\u003e: Kết thúc lưới kim loại bên ngoài của dây cặp xoắn thiết bị bằng thanh nối đất đặt trên khung cửa vào tủ. Duy trì điểm nối đất đơn tại tường tủ điều khiển để loại bỏ phản hồi vòng lặp đất tần số thấp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCấu hình dự phòng\u003c\/strong\u003e: Để triển khai các mô-đun dự phòng, cả hai thiết bị phải nằm trong cụm khe cắm ghép đôi giống hệt nhau. Lập bản đồ thứ tự chính\/phụ trong phần mềm lập trình điều khiển để xử lý chức năng chờ nóng.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eĐiều hướng tách cáp\u003c\/strong\u003e: Dẫn các tín hiệu hoạt động dòng thấp trong các ống dây riêng biệt, cách ly khỏi biến tần tốc độ biến đổi, khối điều khiển tiếp điểm lớn và các đường dây điện ba pha nặng với khoảng cách không khí tối thiểu là 30 cm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955916139,"sku":"3BSE023675R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse023675r1-gu1p3aqzaub_06616861-c453-4b2e-9abe-458dadb57d0f.jpg?v=1766478073"},{"product_id":"abb-ao810v2-3bse038415r1-s800-i-o-analog-output-module","title":"Mô-đun Đầu ra Tương tự ABB AO810V2 3BSE038415R1 S800 I\/O","description":"\u003ch3\u003eMô tả\u003c\/h3\u003e\n\u003cp\u003eĐược thiết kế để tích hợp liền mạch vào hệ thống I\/O S800, \u003cstrong\u003eABB AO810V2\u003c\/strong\u003e (mã sản phẩm \u003cstrong\u003e3BSE038415R1\u003c\/strong\u003e) cung cấp tín hiệu điều khiển analog đáng tin cậy cho các ứng dụng tự động hóa quy trình. Module này hoạt động như một giao diện công nghiệp chuyển đổi các lệnh điều khiển kỹ thuật số thành tín hiệu dòng điện analog tiêu chuẩn, cho phép điều khiển chính xác các thiết bị hiện trường như van điều khiển, bộ truyền động, bộ định vị và biến tần điều chỉnh tốc độ.\u003c\/p\u003e\n\n\u003cp\u003e3BSE038415R1 nổi bật với kết cấu chắc chắn, cách ly điện và thiết kế mật độ cao, là thành phần đáng tin cậy cho cả hệ thống điều khiển máy nhỏ và hệ thống điều khiển phân tán (DCS) quy mô lớn. Hoạt động trong nền tảng I\/O S800, nó giao tiếp trực tiếp với bộ điều khiển ABB Advant và System 800xA, cung cấp các tùy chọn chẩn đoán và cấu hình ngay từ trạm kỹ thuật.\u003c\/p\u003e\n\n\u003ch3\u003eTính năng\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCung cấp nhiều kênh đầu ra analog độ chính xác cao cho điều khiển thiết bị linh hoạt.\u003c\/li\u003e\n  \u003cli\u003eCó cách ly galvanic giữa mạch hiện trường và hệ thống nội bộ để bảo vệ điện tử điều khiển.\u003c\/li\u003e\n  \u003cli\u003eĐầu ra chống ngắn mạch giúp ngăn ngừa hư hỏng do lỗi đấu dây hiện trường.\u003c\/li\u003e\n  \u003cli\u003eHỗ trợ Hot Swap (tháo lắp khi có điện) khi kết hợp với các Đơn vị Kết thúc Module (MTU) tương thích.\u003c\/li\u003e\n  \u003cli\u003eĐèn báo trạng thái mặt trước cung cấp thông tin chẩn đoán và cảnh báo lỗi theo thời gian thực.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eQuản lý van điều khiển và bộ truyền động định vị trong các nhà máy lọc dầu, khí và hóa chất.\u003c\/li\u003e\n  \u003cli\u003ePhân phối tín hiệu tham chiếu tốc độ cho biến tần (VFD) trong các nhà máy xử lý nước.\u003c\/li\u003e\n  \u003cli\u003eĐiều khiển vòng quy trình trong các nhà máy phát điện và tiện ích công cộng.\u003c\/li\u003e\n  \u003cli\u003eHệ thống tự động hóa sản xuất chung và ngành giấy bột.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThông số kỹ thuật\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNhà sản xuất\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMã sản phẩm \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAO810V2 \/ 3BSE038415R1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDòng sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eS800 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoại module\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModule đầu ra analog\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhạm vi dòng đầu ra\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 đến 20 mA, 4 đến 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGiai đoạn vòng đời sản phẩm\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eĐang hoạt động\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTrọng lượng\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0,50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKích thước (R x C x S)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 mm x 120 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cp\u003eĐể đảm bảo hiệu suất tối ưu và vận hành an toàn cho Module đầu ra analog 3BSE038415R1, hãy tuân thủ các quy trình lắp đặt điện và vật lý sau:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLắp đặt:\u003c\/strong\u003e Gắn chắc module vào Đơn vị Kết thúc Module (MTU) S800 được lắp trên thanh ray DIN tiêu chuẩn 35mm. Đảm bảo MTU được nối đất đúng cách trước khi trượt module vào vị trí.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChống nhiễu:\u003c\/strong\u003e Sử dụng cáp xoắn đôi có lớp chắn cho tất cả các đường tín hiệu analog. Nối đất lớp chắn cáp chỉ ở một đầu (thường là tại cửa tủ hoặc khối đầu cuối) để tránh vòng đất.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTách dây:\u003c\/strong\u003e Định tuyến cáp tín hiệu analog tránh xa các đường dây điện AC cao áp và cáp động cơ để giảm nhiễu điện từ.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThông gió:\u003c\/strong\u003e Cung cấp khoảng cách đủ trong tủ để duy trì nhiệt độ vận hành trong giới hạn môi trường tiêu chuẩn của S800. Không che chắn các khe thông gió.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956243819,"sku":"3BSE038415R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse038415r1-fpyfc1332cj_4d48fd49-9479-4bee-aa48-d58d4ed92bf1.jpg?v=1766478084"},{"product_id":"abb-tu810v1-3bse013230r1-s800-i-o-compact-module-termination-unit","title":"ABB TU810V1 3BSE013230R1 S800 I\/O Compact Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Serving as a robust connection interface within the S800 I\/O distributed automation architecture, the \u003cstrong\u003eABB TU810V1\u003c\/strong\u003e (part number \u003cstrong\u003e3BSE013230R1\u003c\/strong\u003e) acts as a compact module termination unit designed to route signals reliably between field wiring and active I\/O process modules. This unit accommodates up to 16 independent channels, operating at a maximum rating of 50V, making it a critical component for high-density cabinet layouts where footprint optimization is vital.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Density Compact Footprint:\u003c\/strong\u003e Allows direct horizontal or vertical DIN-rail mounting to minimize cabinet space requirements.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e16-Channel Configuration:\u003c\/strong\u003e Routes up to 16 individual I\/O channels alongside dual process voltage connections.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eMechanical Coding Keys:\u003c\/strong\u003e Prevents mismatched module insertion, safeguarding the active electronics from field configuration errors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Modulebus Link:\u003c\/strong\u003e Seamlessly transfers signals and power to adjacent units without external jumper cables.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDual Voltage Distribution:\u003c\/strong\u003e Includes 2 isolated groups with commoned terminal distribution points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAdvant OCS and System 800xA distributed control architectures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePetrochemical, power generation, and water treatment field-instrumentation processing.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-density electrical marshaling cabinets and field junction boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTU810V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct ID \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3BSE013230R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eS800 I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eType\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCompact Module Termination Unit (MTU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e50 V DC \/ AC maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3 A per channel maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSingle-wire screw clamp terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConductor Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.2 to 2.5 mm² (24 to 14 AWG)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModulebus Load\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNegligible (passive routing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e165 mm x 45 mm x 72 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eTerminal \/ Connector Point\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 1 to 16\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eI\/O Channel connections (Signals 1 to 16)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 17 \u0026amp; 18\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProcess Voltage Common 1 (distribution bus)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 19 \u0026amp; 20\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProcess Voltage Common 2 (distribution bus)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The TU810V1 serves as a direct, drop-in evolution of the legacy TU810 compact MTU. The V1 variant features improved thermal tolerance and mechanical housing updates, ensuring absolute backward-compatibility with all existing S800 I\/O modules that require a 50V connection interface. If upgrading from non-V1 units, no software modifications or engineering changes are required in the System 800xA or Control Builder environments.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  While rated for 50V operational limits, designers must verify that the total accumulated current across all 16 connected channels does not exceed the capacity of the power distribution source. In highly compact enclosures, field wiring must be routed systematically to prevent localized heating near the screw terminals, which could accelerate degradation of the adjacent active I\/O modules.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To ensure noise immunity in electromagnetic interference (EMI) heavy environments, signal cables should be shielded up to the cabinet entrance, and shields must be grounded to a designated bar separate from the MTU. Ensure that the plastic coding keys on the MTU base are properly configured to match the corresponding module type before power-up to prevent physical component damage during hot-swapping procedures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Complete physical isolation and de-energization of the field supply and Modulebus backplane are mandatory before mounting, unmounting, or wiring the MTU. Failure to isolate power may cause electrical arcing, module destruction, or hazardous field conditions.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eMount the TU810V1 MTU onto a grounded 35mm horizontal DIN rail by latching the top groove and snapping the lower locking tab onto the rail.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eSlide the unit laterally along the DIN rail to connect its Modulebus port directly to the adjacent MTU\/Modulebus optical port, ensuring the connection latches completely.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eStrip field signal and distribution wires to 6mm, insert them into the screw terminals (terminals 1-20), and torque them uniformly to 0.5 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eConfigure the physical mechanical coding keys on the MTU surface to correspond with the targeted I\/O module type before docking the electronic module.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956800875,"sku":"3BSE013230R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013230r1-fbjpzifxlxq_b99e9acb-757e-4b4d-85f5-6d8fe75ecb86.jpg?v=1766478102"},{"product_id":"abb-3bse018172r1-advant-s800-i-o-sb822-rechargeable-battery-unit","title":"ABB 3BSE018172R1 Advant S800 I\/O SB822 Rechargeable Battery Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for reliable backup power protection within process automation systems, the \u003cstrong\u003eABB 3BSE018172R1\u003c\/strong\u003e serves as a dedicated \u003cstrong\u003eSB822 rechargeable battery unit\u003c\/strong\u003e. This module provides essential 24V DC backup power, ensuring that critical configuration parameters and volatile memory states are preserved during primary power supply interruptions or planned system shutdowns. Engineered specifically for integration with the Advant S800 I\/O architecture, it maintains system integrity and prevents data loss in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides continuous 24V DC backup power to prevent processor memory loss.\u003c\/li\u003e\n  \u003cli\u003eFully integrated form factor compatible with Advant S800 I\/O mounting requirements.\u003c\/li\u003e\n  \u003cli\u003eConstructed for robust industrial operations, offering stable voltage characteristics over its operational life.\u003c\/li\u003e\n  \u003cli\u003eEnables simple maintenance and replacement routines within standard system cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing, refining, and petrochemical installations.\u003c\/li\u003e\n  \u003cli\u003eContinuous process industries requiring uninterruptible data retention.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3BSE018172R1 (SB822)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAdvant S800 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25 cm x 12 cm x 10 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85389091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eECCN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance and safety, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit in a well-ventilated enclosure to prevent localized heat accumulation. Ensure orientation complies with standard ABB cabinet layout recommendations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use recommended cable gauges and verify correct polarity before connecting the unit to the 24V DC backplane or distribution bus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Implement a routine battery check schedule. Replace the unit at recommended service intervals to ensure reliable power retention during unexpected outages.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956997483,"sku":"3BSE018172R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse018172r1-zt3ltub0vnh_6ade710e-b8d2-4b34-a084-2cc2f86db250.jpg?v=1766478107"},{"product_id":"abb-do810-3bse008510r1-advant-s800-i-o-digital-output-module","title":"ABB DO810 3BSE008510R1 Advant S800 I\/O Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration within the S800 I\/O system, the \u003cstrong\u003eABB 3BSE008510R1\u003c\/strong\u003e (DO810) provides reliable 24 V DC digital output control for process automation applications. This 16-channel current-sourcing module interfaces field-level actuators, relays, and indicators with the controller via the ModuleBus. Operating with high efficiency, the \u003cstrong\u003eDO810 digital output module\u003c\/strong\u003e features electronic short-circuit protection and diagnostics to minimize system downtime in demanding industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eThe module mounts directly onto a compatible Module Termination Unit (MTU), allowing for simple, tool-free field wiring. It supports hot-swapping under power, enabling swift module replacement without disrupting system operations. Galvanic isolation between the internal logic (ModuleBus) and field outputs ensures reliable signal isolation and protection of the host PLC\/DCS controller.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 16 current-sourcing digital output channels rated at 24 V DC.\u003c\/li\u003e\n  \u003cli\u003eEquipped with built-in electronic short-circuit and over-temperature protection.\u003c\/li\u003e\n  \u003cli\u003eProvides individual channel LED status indication along with global RUN\/FAULT diagnostic indicators.\u003c\/li\u003e\n  \u003cli\u003eSupports dynamic hot-swapping during runtime, minimizing process interruption.\u003c\/li\u003e\n  \u003cli\u003ePairs with various standard S800 I\/O Termination Units (MTUs) for flexible wiring configurations.\u003c\/li\u003e\n  \u003cli\u003eGalvanically isolated from system backplane circuitry to prevent ground loop issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and oil and gas processing facilities.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal treatment installations.\u003c\/li\u003e\n  \u003cli\u003ePulp and paper machine controls.\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial factory automation systems utilizing System 800xA or Advant OCS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3BSE008510R1 \/ DO810\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAdvant S800 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 mA (off-state)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eElectronic, thermal current limitation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes (tested at 50 V DC to system backplane)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 4.5 W at nominal operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC (vertical mounting), 0 to 40 degC (horizontal mounting)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance and safe operation of the DO810 digital output module, adhere to the following installation instructions:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the Module Termination Unit (MTU) is securely latched to the standard DIN rail before inserting the DO810 module. Do not force alignment pins during insertion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route all field digital output cables away from high-voltage AC lines or power distribution cables to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the DIN rail to a low-impedance safety ground system. Proper grounding of the MTU is required for robust functional earth (FE) protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain standard clearance gaps above and below the module assembly to allow natural convective cooling. Do not exceed the rated maximum operating temperature of 55 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957226859,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse008510r1-io20znm2zt3_68e21796-b812-4bde-85b8-352de44a17cd.jpg?v=1766478115"},{"product_id":"abb-3bse013224r1-ci810v2-advant-s800-i-o-af100-communication-interface","title":"ABB 3BSE013224R1 CI810V2 Advant S800 I\/O AF100 Communication Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating seamless Advant Fieldbus 100 connectivity into distributed control architectures, the \u003cstrong\u003eABB 3BSE013224R1 CI810V2\u003c\/strong\u003e functions as a high-speed communication interface for S800 I\/O modules. This field communication interface acts as the local link master, managing exchange rates and diagnostic reporting between connected I\/O clusters and upper-level Advant Controllers (such as AC 800M or AC 450). It delivers reliable cyclic data transmission and supports redundant configurations to maximize process uptime in heavy industrial automation systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eProvides physical and logical connection to the Advant Fieldbus 100 (AF100) twisted-pair network.\u003c\/li\u003e\n  \u003cli\u003eSupports up to 12 S800 I\/O modules per cluster, handling both digital and analog signal types.\u003c\/li\u003e\n  \u003cli\u003eEquipped with comprehensive LED diagnostics on the front face for run, fail, and traffic status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports hot-swap operation (Hot Configuration in Run) when paired with compatible module termination units.\u003c\/li\u003e\n  \u003cli\u003eOptoelectronic galvanic isolation ensures high electromagnetic compatibility (EMC) and protects internal logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) in oil, gas, and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation and turbine control systems requiring deterministic process bus communication.\u003c\/li\u003e\n  \u003cli\u003ePulp and paper mill processing lines with dense, localized analog and digital I\/O clusters.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater plant control upgrades running legacy Advant S800 I\/O networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCI810V2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3BSE013224R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtocol Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAdvant Fieldbus 100 (AF100)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported I\/O System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eS800 I\/O Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC (limits 19.2 V DC to 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 mA typical at 24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 V (galvanic isolation to I\/O backplane)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to +55 degC (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e25.0 x 12.0 x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CI810V2 directly replaces older legacy revisions (such as CI810V1) within existing S800 structures. When upgrading, ensure the system controller's system software\/firmware supports the newer V2 module revision. While form-factor compatible, failing to align controller-side hardware configuration files can prevent module identification on the AF100 bus.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAvoid running signal cables and the AF100 bus lines in the same wire ducts as high-power AC lines to prevent magnetic coupling. In high-temperature panels exceeding 45 degC, verify active air circulation, as the thermal build-up inside tightly enclosed clusters can degrade optical link stability when fiber-optic modems are coupled to the bus.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways double-check that both termination resistors are in place at the physical ends of the AF100 bus network. An un-terminated or double-terminated bus leads to high reflection coefficients and diagnostic errors. Ensure that the module is completely clicked into its slot on the Module Termination Unit (MTU) before securing the screw terminals.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all 24 V DC system power sources before performing physical replacement or wiring on the communication module backplane. Working on an active system can cause transient bus faults, halting down-stream process controllers.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConfigure the station address on the Module Termination Unit (MTU) rotary switches prior to slotting the CI810V2 interface module.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAlign the module guides with the slots on the MTU and push firmly until the locking mechanisms click securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTerminate the AF100 twisted pair cable shield to the grounding rail using low-impedance ground clamps to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eRestore 24 V DC power and verify that the \"RUN\" LED lights steady green, confirming that system initialization is successful.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957390699,"sku":"3BSE013224R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013224r1-2g2zfn5xxly_d85d59c4-674d-4fd8-ac57-c96c0817db42.jpg?v=1766478120"},{"product_id":"abb-do801-3bse020510r1-s800-i-o-digital-output-module","title":"Mô-đun Đầu ra Kỹ thuật số ABB DO801 3BSE020510R1 S800 I\/O","description":"\u003ch3\u003eTóm tắt kiến trúc\u003c\/h3\u003e\n\n\u003cp\u003e\nABB \u003cstrong\u003eDO801\u003c\/strong\u003e (Mã nội bộ: \u003cstrong\u003e3BSE020510R1\u003c\/strong\u003e) là khối đầu ra rời 16 kênh mật độ cao được thiết kế cho nền tảng I\/O S800. Hoạt động trong các hệ thống điều khiển phân tán phức tạp (DCS) như 800xA, thành phần này quản lý các phần tử điều khiển cuối cấp trường trong các ngành công nghiệp quy trình liên tục như lọc hóa dầu, phát điện nhiệt và nhà máy tổng hợp hóa chất.\n\u003c\/p\u003e\n\n\u003cp\u003e\nMô-đun tổ chức 16 đầu ra trạng thái rắn thành một nhóm galvanic cách ly duy nhất, bảo vệ logic điều khiển quan trọng khỏi các xung điện bên phía trường. Được trang bị bảo vệ ngắn mạch điện tử tích hợp mạnh mẽ và giới hạn dòng 0,5 A mỗi kênh, \u003cstrong\u003eDO801\u003c\/strong\u003e chủ động ngăn chặn sự cố dây cục bộ lan rộng thành mất điện toàn hệ thống, giảm đáng kể thời gian ngừng hoạt động không kế hoạch.\n\u003c\/p\u003e\n\n\u003ch3\u003eCơ sở hạ tầng phần cứng \u0026 Cấu hình kênh\u003c\/h3\u003e\n\n\u003cp\u003e\nCấu trúc mô-đun tận dụng thiết kế nhỏ gọn gắn trên thanh DIN, tương thích trực tiếp với các backplane ModuleBus tiêu chuẩn của ABB. Tất cả 16 kênh kỹ thuật số được thiết kế để hoạt động nguồn 24 VDC.\n\u003c\/p\u003e\n\n\u003cp\u003e\nMa trận transistor đầu ra bên trong bao gồm chức năng tắt nhiệt tự động và vòng giới hạn dòng, cho phép phần cứng chịu được ngắn mạch trực tiếp xuống 0 VDC mà không làm hỏng linh kiện. Sự cách ly giữa nhóm dây trường và hệ thống backplane nội bộ được duy trì qua các optocoupler tốc độ cao.\n\u003c\/p\u003e\n\n\u003cp\u003e\nDãy đèn LED phía trước hiển thị trạng thái chẩn đoán theo thời gian thực, ánh xạ kích hoạt từng kênh riêng lẻ và lỗi toàn bộ mô-đun trực tiếp đến nhân viên bảo trì dây chuyền.\n\u003c\/p\u003e\n\n\u003ch3\u003eThông số kỹ thuật toàn diện\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eThông số\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eDữ liệu vận hành\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMẫu mã\u003c\/td\u003e\n            \u003ctd\u003eDO801\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMã sản phẩm\u003c\/td\u003e\n            \u003ctd\u003e3BSE020510R1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eThương hiệu\u003c\/td\u003e\n            \u003ctd\u003eABB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eXuất xứ\u003c\/td\u003e\n            \u003ctd\u003eThụy Điển\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eLoại mô-đun\u003c\/td\u003e\n            \u003ctd\u003eMô-đun đầu ra kỹ thuật số\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSố lượng kênh\u003c\/td\u003e\n            \u003ctd\u003e16 kênh\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eĐiện áp ra danh định\u003c\/td\u003e\n            \u003ctd\u003e24 VDC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDòng ra tối đa\u003c\/td\u003e\n            \u003ctd\u003e0,5 A mỗi kênh (tải trở)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCấu hình cách ly\u003c\/td\u003e\n            \u003ctd\u003e1 nhóm gồm 16 kênh, cách ly với logic\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCấp độ bảo vệ\u003c\/td\u003e\n            \u003ctd\u003eBảo vệ ngắn mạch tích hợp, giới hạn dòng quá tải\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eChiều rộng\u003c\/td\u003e\n            \u003ctd\u003e86,1 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eChiều cao\u003c\/td\u003e\n            \u003ctd\u003e102,0 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eChiều sâu\u003c\/td\u003e\n            \u003ctd\u003e58,5 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTrọng lượng\u003c\/td\u003e\n            \u003ctd\u003e0,24 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTỏa nhiệt\u003c\/td\u003e\n            \u003ctd\u003eTiêu thụ công suất điển hình 2,5 W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNhiệt độ hoạt động\u003c\/td\u003e\n            \u003ctd\u003e0 đến 55 độ C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNhiệt độ lưu trữ\u003c\/td\u003e\n            \u003ctd\u003e-40 đến 70 độ C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eĐộ ẩm tương đối\u003c\/td\u003e\n            \u003ctd\u003e5 đến 95 phần trăm (không ngưng tụ)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTuân thủ RoHS\u003c\/td\u003e\n            \u003ctd\u003eTuân thủ Chỉ thị EU 2011\/65\/EU\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCâu hỏi thường gặp về Chẩn đoán \u0026 Kỹ thuật Ứng dụng\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eModule hoạt động như thế nào trong trường hợp ngắn mạch bên phía trường kéo dài?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\nMô-đun sử dụng bảo vệ ngắn mạch điện tử thông minh. Khi phát hiện quá dòng hoặc ngắn mạch trên một kênh, transistor nội bộ giới hạn dòng và hạ điện áp.\n\u003c\/p\u003e\n\n\u003cp\u003e\nNếu tình trạng tiếp diễn và gây tích tụ nhiệt, kênh bị ảnh hưởng sẽ tự động tắt cho đến khi lỗi được khắc phục và mối nối nguội lại. Trong khi đó, 15 kênh còn lại tiếp tục hoạt động không gián đoạn.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCó thể song song nhiều kênh của DO801 để điều khiển tải lớn hơn không?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\nKhông. Không khuyến nghị song song các đầu ra trong DO801 để đạt dòng điện cao hơn. Sự khác biệt nhỏ về thời gian chuyển mạch transistor có thể dẫn đến quá tải không cân bằng và ngắt nhiệt ngay lập tức trên kênh nhanh hơn.\n\u003c\/p\u003e\n\n\u003cp\u003e\nĐối với nhu cầu dòng điện cao hơn, sử dụng rơ-le trung gian bên ngoài.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMô-đun này có cần nguồn điện bên ngoài cho phía trường không?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\nCó. Mặc dù mô-đun lấy logic nội bộ và sức mạnh xử lý từ backplane S800 ModuleBus, điện áp điều khiển 24 VDC cho 16 kênh đầu ra phải được cấp qua các đầu nguồn trường riêng biệt trên Đế Đầu cuối tương ứng (MTU).\n\u003c\/p\u003e\n\n\u003ch3\u003eHướng dẫn lắp đặt hiện trường chuyên nghiệp \u0026amp; An toàn điện\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eTương thích MTU \u0026amp; Lắp ráp cơ khí:\u003c\/strong\u003e\n            Đảm bảo Đơn vị Đầu cuối Cơ khí (như TU810 hoặc TU812) được cố định chắc chắn trên thanh ray DIN kim loại 35 mm trước khi lắp mô-đun. Căn chỉnh vỏ mô-đun song song với khe MTU và ấn mạnh cho đến khi cả hai chốt giữ nhựa khóa chặt với tiếng kêu “click”.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eThông số lực mô-men xoắn vít đầu cuối:\u003c\/strong\u003e\n            Khi cố định dây trường vào các đầu vít MTU, sử dụng đầu cos dây cho tất cả các dây đã bóc vỏ. Vặn chặt tất cả các vít đầu cuối với lực mô-men xoắn đồng đều từ 0,5 N-m đến 0,6 N-m.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n            Kết nối lỏng lẻo có thể tạo ra các vùng nhiệt điện trở cao, dẫn đến suy giảm tín hiệu gián đoạn.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eỨng phó tải cảm ứng:\u003c\/strong\u003e\n            Khi điều khiển các phần tử cảm ứng như van điện từ 24 VDC, cuộn tiếp điểm động cơ công suất lớn hoặc phanh từ, hãy lắp diode flyback bên ngoài (như 1N4007) trực tiếp trên các cực của tải.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n            Điều này ngăn chặn các xung điện cảm áp cao có thể làm tăng tốc độ lão hóa của các transistor đầu ra mô-đun.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eQuản lý nhiệt và khoảng cách:\u003c\/strong\u003e\n            Duy trì khoảng cách không khí dọc rõ ràng ít nhất 50 mm phía trên và dưới cụm mô-đun. Đảm bảo quạt thông gió hoặc làm mát tủ giữ nhiệt độ không khí môi trường bên trong tủ dưới 55 độ C.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n            Điều này giúp ngăn các mạch bảo vệ ngắn mạch kích hoạt sớm do bão hòa nhiệt độ môi trường.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957489003,"sku":"3BSE020510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse020510r1-4h3flck0pqn_29c12f70-714f-4ed5-acdd-4264f1770c96.jpg?v=1766478123"},{"product_id":"abb-3bse041882r1-ci840a-s800-i-o-profibus-dp-v1-interface","title":"ABB 3BSE041882R1 CI840A S800 I\/O PROFIBUS DP-V1 Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3BSE041882R1 CI840A\u003c\/strong\u003e serves as a high-performance communication interface designed to manage data exchange between the S800 I\/O station and a PROFIBUS DP-V1 master unit. This field communication interface handles cyclic data exchange alongside non-cyclic configuration, diagnostics, and parameter assignment tasks. Engineered for seamless deployment across industrial automation environments, it offers complete software compatibility with the ABB 800xA distributed control system and Compact Product Suite platforms. The unit acts as a crucial link for field devices, translating signals reliably while permitting the implementation of complete physical media redundancy. Operating the \u003cstrong\u003e3BSE041882R1 CI840A\u003c\/strong\u003e within demanding industrial plants guarantees precise, real-time control loop execution and continuous communication uptime across critical automation networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides standard field bus communication interface using the PROFIBUS DP-V1 protocol.\u003c\/li\u003e\n\u003cli\u003eIntegrates directly into multiple generations of S800 I\/O systems, including versions 4.1, 5.0, and 5.1.\u003c\/li\u003e\n\u003cli\u003eFacilitates full redundancy schemes for dual interface topologies when paired with specific modular terminal units.\u003c\/li\u003e\n\u003cli\u003eFeatures a lightweight, space-saving design optimizing DIN rail space inside standard marshalling panels.\u003c\/li\u003e\n\u003cli\u003eOperates with absolute zero battery requirements, reducing routine infrastructure upkeep costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) integration via PROFIBUS communication infrastructures.\u003c\/li\u003e\n\u003cli\u003eRedundant field I\/O data aggregation for System 800xA production networks.\u003c\/li\u003e\n\u003cli\u003eFactory automation assembly interfaces using Compact Product Suite controller packages.\u003c\/li\u003e\n\u003cli\u003eHigh-availability process lines requiring redundant communication modules on matching terminal units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eQty\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3BSE041882R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCI840A PROFIBUS DP-V1 Interface\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE041882R1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCI840A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number \/ HS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85176200 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly\u003c\/strong\u003e: Fit the interface module firmly onto its designated slot on the terminal base unit. Ensure the rear grounding contacts press cleanly against the DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Configuration\u003c\/strong\u003e: To implement a redundant communication interface, two CI840A modules must be ordered and paired with either one TU847 or one TU846 terminal unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segment Isolation\u003c\/strong\u003e: Route the PROFIBUS DB9 network cable away from high-voltage motor starters and power lines to reduce EMI\/RFI noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Retention\u003c\/strong\u003e: Verify the module locking latches engage properly after insertion into the base unit to withstand industrial vibration and shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e: Manufactured in accordance with the regulatory standards outlined in EU Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Category\u003c\/strong\u003e: Classified under Category 5: Small Equipment (No External Dimension More Than 50 cm).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957816683,"sku":"3BSE041882R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse041882r1-dywrfhj0qbg_0ff1a729-dfd6-4949-9f9e-eb21a6e3a847.jpg?v=1766478133"},{"product_id":"abb-tu831v1-3bse013235r1-s800-i-o-extended-mtu-module-termination-unit","title":"ABB TU831V1 3BSE013235R1 S800 I\/O Extended MTU Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU831V1\u003c\/strong\u003e is an \u003cstrong\u003eExtended Module Termination Unit (MTU)\u003c\/strong\u003e engineered for the \u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e system. It provides a reliable mechanical and electrical platform for interfacing field wiring with specified S800 I\/O modules. Featuring a \u003cstrong\u003e2x8 signal terminal\u003c\/strong\u003e configuration, this extended unit breaks out field signals efficiently while establishing the necessary connections to the internal ModuleBus.\u003c\/p\u003e\n\u003cp\u003eIn contrast to low-voltage termination bases, this unit features an insulation rating up to \u003cstrong\u003e250V\u003c\/strong\u003e, making it suitable for standard process voltage networks, high-voltage discrete control loops, and specialized power signaling environments. It integrates smoothly into various generations of decentralized control networks, ensuring consistent signal path distribution without compromising field isolation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtended layout featuring 2x8 signal terminal connections\u003c\/li\u003e\n\u003cli\u003eHigher dielectric rating optimized for applications up to 250V\u003c\/li\u003e\n\u003cli\u003eDirect pass-through connectivity to the S800 ModuleBus interface\u003c\/li\u003e\n\u003cli\u003eCompact footprint optimizing available cabinet real estate\u003c\/li\u003e\n\u003cli\u003eReliable wire-clamp termination points for direct field landing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) managed by ABB System 800xA platforms\u003c\/li\u003e\n\u003cli\u003eLegacy Advant OCS with Master or MOD 300 software via Advant Fieldbus 100\u003c\/li\u003e\n\u003cli\u003eProcess loop terminations in high-density Compact Product Suite infrastructure\u003c\/li\u003e\n\u003cli\u003e120V\/240V AC or DC discrete control interfaces within power generation and water treatment facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\/Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU831V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013235R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule_Termination_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x8 signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCIP Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo SVHC present Bulgaria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Allocation\u003c\/strong\u003e: Affix the base securely to the designated section of the DIN rail, ensuring standard locking clips engage fully to prevent lateral sliding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Separation\u003c\/strong\u003e: Maintain proper clearance between high-voltage field wiring (up to 250V) routed to this unit and nearby low-voltage instrument signals to minimize electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e: Secure field conductors into the screw clamp or compression terminals using the manufacturer-specified torque limits to avoid loosening from vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Align the mating plug of the matching S800 I\/O module vertically with the guide pins of the MTU before exerting downward force to sit the module securely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation \"Extended MTU\" indicate for this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates the presence of an expanded physical layout or additional terminal capacity, structured here as a 2x8 matrix, providing extra termination flexibility for specific I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this termination unit safe for standard 230V AC applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the technical data sheet specifies a maximum insulation threshold of 250V, which accommodates standard 120V and 230V industrial control voltages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this base unit be utilized within an Advant OCS architecture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is officially classified for use with Advant OCS with Master or MOD 300 software utilizing Advant Fieldbus 100 setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain any substance of very high concern (SVHC)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, according to the official SCIP filing, there are no SVHC present in this hardware variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical weight of the unit without an I\/O module attached?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe net engineering weight of the bare module termination unit is exactly 0.22 kg.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958078827,"sku":"3BSE013235R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013235r1-n2swcuhstsy_0e6457d9-fda2-4fb1-a534-4c9c80718bf4.jpg?v=1766478142"},{"product_id":"abb-s800-i-o-3bse008538r1-tb807-modulebus-terminator","title":"ABB S800 I\/O 3BSE008538R1 TB807 Modulebus Terminator","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTB807 (3BSE008538R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ABB S800 I\/O Modulebus terminator designed to ensure stable signal integrity at the end of the Modulebus communication line. It provides electrical termination to prevent reflections, signal distortion, and communication instability in distributed I\/O architectures.\u003c\/p\u003e\n\u003cp\u003eThis component is widely used in ABB 800xA and S800 I\/O systems deployed in power plants, oil and gas facilities, and continuous process industries. It plays a critical role in maintaining deterministic communication across high-density I\/O networks. Without correct termination, Modulebus performance degrades and may cause intermittent system faults.\u003c\/p\u003e\n\u003cp\u003eEngineers install TB807 to secure network stability in both new installations and retrofit expansions. It supports long-term reliability in harsh electrical environments where signal quality is sensitive to noise and impedance mismatch.\u003c\/p\u003e\n\u003ch3\u003eFunctional Role in Modulebus Network\u003c\/h3\u003e\n\u003cp\u003eTB807 functions as a passive termination element for the ABB Modulebus communication line. It does not require configuration, addressing, or external power supply.\u003c\/p\u003e\n\u003cp\u003eThe device ensures correct impedance matching at the end of the bus segment. This prevents signal reflection that can affect data transmission between S800 I\/O modules and controllers. It is a mandatory component in properly designed ABB Modulebus topologies.\u003c\/p\u003e\n\u003cp\u003eThe compact design allows direct installation into terminal positions within S800 I\/O assemblies. It maintains system communication integrity without introducing latency or active processing overhead.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Code\u003c\/td\u003e\n\u003ctd\u003e3BSE008538R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModulebus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13 x 19 x 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNone (passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eModulebus termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs TB807 required in every S800 I\/O system?\u003c\/strong\u003e\u003cbr\u003eYes, it is required at the end of each Modulebus segment to ensure signal stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan TB807 be replaced with a generic resistor?\u003c\/strong\u003e\u003cbr\u003eNo, ABB specifies TB807 to match Modulebus electrical characteristics precisely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if TB807 is not installed?\u003c\/strong\u003e\u003cbr\u003eMissing termination can cause communication errors, data loss, or unstable I\/O behavior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs TB807 an active electronic module?\u003c\/strong\u003e\u003cbr\u003eNo, it is a passive termination device with no logic or power consumption.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall TB807 only at the final node of the Modulebus segment. Incorrect placement in the middle of the bus will destabilize communication.\u003c\/p\u003e\n\u003cp\u003eEnsure firm seating into the designated terminal position. Loose installation can introduce intermittent signal reflection under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eMaintain correct system topology before commissioning. Verify that only one termination exists per bus segment to avoid impedance imbalance.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958242667,"sku":"3BSE008538R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse008538r1-qwcxjxpdrdq_7b6ef9de-77b1-4988-885d-68d65eeaf0d5.jpg?v=1766478147"},{"product_id":"tu811v1-3bse013231r1-abb-s800-i-o-compact-mtu-module-termination-unit","title":"TU811V1 3BSE013231R1 ABB S800 I\/O Compact MTU Module Termination Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTU811V1 (3BSE013231R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB S800 I\/O Compact MTU provides a compact module termination solution for distributed control systems requiring stable signal interfacing at field level. It is designed for ABB S800 I\/O architectures used in power plants, oil refineries, offshore platforms, and industrial automation systems where reliable signal termination is critical. The unit supports 1 x 8 signal terminals and ensures secure electrical connection between field wiring and I\/O modules. Engineers deploy it to simplify cabinet wiring and reduce installation time in modular control systems. Its compact footprint allows high-density installation in constrained panel environments. The design improves system reliability by providing stable termination points for low and medium voltage signal circuits up to 250 V. It plays a key role in reducing wiring errors and maintenance downtime in continuous process industries.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration and Signal Interface Design\u003c\/h3\u003e\n\u003cp\u003eThe TU811V1 functions as a passive termination interface between field devices and S800 I\/O modules. It provides structured 8-channel signal routing through a compact terminal layout. The module integrates directly into ABB S800 I\/O racks, ensuring consistent signal integrity and mechanical stability. Each terminal point is engineered for secure clamping and vibration resistance in industrial environments. The design supports standardized wiring practices for scalable control system expansion. It eliminates complex marshalling panels by centralizing field termination at module level. Electrical isolation depends on the connected I\/O module design within the S800 system architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU811V1 (3BSE013231R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x H x W)\u003c\/td\u003e\n\u003ctd\u003e64 mm x 170 mm x 58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive module (no internal consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O base system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSignal termination interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs TU811V1 compatible with all S800 I\/O modules?\u003c\/strong\u003e\u003cbr\u003eIt is designed for ABB S800 I\/O systems and works with supported compatible I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes TU811V1 provide signal conditioning or isolation?\u003c\/strong\u003e\u003cbr\u003eNo, it functions as a passive termination unit. Signal conditioning is handled by the I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in high vibration environments?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for industrial cabinets with vibration-resistant terminal structures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum voltage rating supported?\u003c\/strong\u003e\u003cbr\u003eIt supports up to 250 V field signal wiring as per S800 I\/O specifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the TU811V1 on a properly grounded S800 I\/O mounting structure. Ensure tight and uniform terminal torque to maintain long-term signal stability. Use shielded cables for field wiring in high electromagnetic interference zones. Keep separation between power cables and signal terminals to reduce noise coupling. Verify correct module alignment before energizing the system. In high vibration environments, inspect terminal tightness during scheduled maintenance cycles. Maintain proper cabinet airflow to support long-term reliability of adjacent I\/O modules.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958472043,"sku":"3BSE013231R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013231r1-mssxetxhs4t_383def30-cffd-4e02-b7a5-60e8177fa84f.jpg?v=1766478154"},{"product_id":"abb-tu830v1-s800-i-o-extended-module-termination-unit-3bse013234r1","title":"ABB TU830V1 S800 I\/O Extended Module Termination Unit 3BSE013234R1","description":"\u003ch3\u003eS800 I\/O Termination Interface Overview\u003c\/h3\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eTU830V1 (3BSE013234R1)\u003c\/strong\u003e is an extended Module Termination Unit (MTU) within ABB’s S800 I\/O system. \nIt provides the physical and electrical interface between I\/O modules and field wiring, forming a critical part of the signal distribution architecture in industrial control systems.\n\u003c\/p\u003e\n\n\u003cp\u003e\nUnlike compact MTUs, the TU830V1 features an extended terminal layout that supports high-density wiring and shared power distribution. \nIt is widely used in ABB 800xA, Advant OCS, and Compact Product Suite environments, where modularity and fast maintenance are essential.\n\u003c\/p\u003e\n\n\u003ch3\u003eWiring Architecture \u0026amp; Functional Design\u003c\/h3\u003e\n\n\u003cp\u003e\nThe TU830V1 is designed to simplify cabinet wiring while maintaining signal stability and mechanical robustness:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Density:\u003c\/strong\u003e 32 terminals arranged in 2 × 16 configuration for high-channel I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e Rated up to 50 V, optimized for 24 VDC digital and analog signal applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e Supports a wide range of S800 I\/O modules via ModuleBus integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Locking:\u003c\/strong\u003e DIN rail mounting with secure locking lever for vibration-resistant installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Screw terminals designed for stable long-term electrical and mechanical connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eElectrical \u0026amp; Mechanical Data\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU830V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013234R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit (MTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 (2 × 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.5 × 110 × 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplication \u0026amp; System Notes\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between TU810 and TU830V1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nThe TU810 is a compact MTU with fewer terminals and typically requires external terminal blocks for distribution. \nThe TU830V1 provides extended 2 × 16 terminals, allowing direct connection of both signal and common wiring on the same unit.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan TU830V1 be used with high-voltage I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nNo. The TU830V1 is limited to a maximum of 50 V. \nHigh-voltage modules require appropriately rated MTUs with increased clearance distances for safety compliance.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this MTU support redundant I\/O configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nNo. The TU830V1 is intended for single-module operation. \nRedundant I\/O systems require specialized MTU variants such as TU842 or TU843.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cbr\u003e\nUse wire-end ferrules for all field connections. \nApply correct torque to terminal screws (typically 0.5 Nm) to avoid damage to internal contact structures.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eModuleBus Integration:\u003c\/strong\u003e\u003cbr\u003e\nEnsure proper engagement of ModuleBus connectors between adjacent MTUs on the DIN rail. \nThis guarantees stable communication and power distribution across the I\/O cluster.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGrounding Strategy:\u003c\/strong\u003e\u003cbr\u003e\nConnect DIN rail to functional earth to support shielding and reduce electromagnetic interference in dense cabinet environments.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLabeling Discipline:\u003c\/strong\u003e\u003cbr\u003e\nClearly label terminal rows and signal groups. With 32 terminals per unit, structured identification is critical for commissioning accuracy.\n\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958963563,"sku":"3BSE013234R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013234r1-zo4lmi350nr_4ebfa23c-0d6e-41b3-a8bd-98b8636b1bf7.jpg?v=1766478166"},{"product_id":"abb-di810-3bse008508r1-s800-i-o-16-channel-digital-input-module","title":"ABB DI810 3BSE008508R1 S800 I\/O 16-Channel Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI810 (3BSE008508R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-111 citation-end-111\"\u003eThis versatile module features 16 channels specifically rated for 24 VDC signals, making it a cornerstone for industrial automation within the 800xA, Advant OCS, and Compact Product Suite environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for maximum reliability, featuring galvanic isolation between two groups of 8 channels to prevent ground loops and protect the system bus from field-side electrical interference.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-110 citation-end-110\"\u003eIts compact design and \"hot-swap\" capability ensure that process interruptions are minimized, providing a scalable and robust interface for discrete sensors, switches, and auxiliary contacts in demanding applications such as power generation, chemical processing, and marine engineering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for seamless integration and field-side flexibility:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-109\"\u003e\u003c\/span\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan class=\"citation-109 citation-end-109\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides 16 digital input channels, categorized into two isolated groups of 8 channels each, allowing for different power source references within a single module.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMTU Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to be used with a wide range of Module Termination Units (MTU), including the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTU810, TU812, TU814, TU818, TU830, TU833, TU838, and TU850\u003c\/strong\u003e, providing various wiring options (crimp, screw, or spring).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with ABB’s flagship control systems, including System 800xA (versions 4.0 through 6.0), Advant Fieldbus 100, and the Compact Product Suite.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 24 VDC positive logic, optimized for industrial standard sensors and mechanical contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a plug-and-play interface that connects directly to the S800 I\/O backplane\/MTU, allowing for rapid deployment and easy maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDI810\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE008508R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS800 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Isolated in 2 groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm x 119 mm x 102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-power design for high-density packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroup-to-group and group-to-bus isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C (standard industrial range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Module Termination Unit (MTU) should I select for the DI810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe selection depends on your wiring preference. For standard screw terminals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTU810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTU830\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare common choices. If your application requires high-density spring terminals to resist vibration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTU812\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTU814\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the two groups of 8 channels be powered by different 24V sources?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the two groups are isolated from each other, you can use independent power supplies for each group of 8 channels, which is ideal for systems requiring physical separation of safety or interlocking circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DI810 support \"Hot-Swap\" functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When used within an S800 I\/O station, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule can be removed and replaced while the system is powered (under certain configuration conditions), significantly reducing downtime during maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMTU Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the Module Termination Unit (MTU) is securely fastened to the DIN rail before plugging in the DI810 module. The module should snap into place with a firm click to ensure the internal bus connectors are fully engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor 24 VDC inputs, ensure that the cable runs are appropriately shielded if they pass near high-voltage motor cables. The isolation in the DI810 provides protection, but good EMC practices prevent nuisance signal flickering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemember that channels 1-8 share a common return and channels 9-16 share a separate common return. Do not bridge these returns if you wish to maintain the galvanic isolation between the two groups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn environments with high humidity or corrosive gases, ensure the I\/O cabinet is appropriately rated. The DI810 is a compact IP20-rated module and relies on the enclosure for primary environmental protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959160171,"sku":"3BSE008508R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse008508r1-ubc5jxm3rtu_9d0b6046-10df-42ec-ba7b-7b22a8fc7240.jpg?v=1766478172"},{"product_id":"abb-s800-i-o-3bse008544r1-ai820-analog-input-module","title":"ABB S800 I\/O 3BSE008544R1 | AI820 Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eABB \u003cstrong\u003e3BSE008544R1\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e (Type: AI820) \u003c\/strong\u003eis a high-performance \u003cspan\u003e4-channel Analog Input Module\u003c\/span\u003e designed for the \u003cspan\u003eS800 I\/O\u003c\/span\u003e family. This module is engineered for maximum versatility, supporting a wide range of voltage and current signals, including bipolar ranges such as ±20mA and ±10V. A critical feature of the \u003cspan\u003eAI820\u003c\/span\u003e is its \u003cspan\u003eindividually galvanic isolated channels\u003c\/span\u003e, which provide superior protection against ground loops and common-mode interference up to 50V. This makes the \u003cspan\u003e3BSE008544R1\u003c\/span\u003e an ideal choice for complex industrial environments where signal integrity and high precision are required for mission-critical process monitoring.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Signal Precision\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eAI820\u003c\/span\u003e utilizes \u003cspan\u003e14-bit plus sign\u003c\/span\u003e resolution to deliver high-fidelity data to the controller. Each of the four channels can be independently configured for different signal types, allowing a single module to simultaneously process inputs from diverse field instruments like pressure transmitters, flow meters, and temperature sensors. Its high input impedance for voltage signals and a precise \u003cspan\u003e250 Ohm\u003c\/span\u003e internal resistance for current signals ensure minimal load on field devices. The module integrates seamlessly with \u003cspan\u003e800xA\u003c\/span\u003e, \u003cspan\u003eAdvant OCS\u003c\/span\u003e, and \u003cspan\u003eCompact Product Suite\u003c\/span\u003e systems, providing deterministic data acquisition across the plant floor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct ID\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE008544R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI820\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Individually Galvanically Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Ranges (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±20mA, 0(4)...20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Ranges (Voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, ±5V, 0(1)...5V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit + sign\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommon Mode Voltage (CMV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 V (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (HxWxD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e119 mm x 45 mm x 102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhy is individual galvanic isolation important?\u003c\/span\u003eIn many analog loops, different field instruments may have varying ground potentials. Without individual isolation, these differences can cause ground loop currents that distort signals or damage hardware. The \u003cspan\u003eAI820\u003c\/span\u003e isolates each channel from the others and from the system backplane, ensuring that an electrical fault or noise on one channel does not affect the rest of the module or the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhich Module Termination Units (MTUs) are compatible with 3BSE008544R1?\u003c\/span\u003eThe \u003cspan\u003eAI820\u003c\/span\u003e must be paired with an S800 MTU for field wiring. Compatible units include \u003cspan\u003eTU810, TU812, TU814, TU830,\u003c\/span\u003e or \u003cspan\u003eTU833\u003c\/span\u003e. The choice of MTU depends on whether your application requires screw terminals, spring terminals, or extended grounding features.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMTU Selection:\u003c\/span\u003e Verify your field wiring type before installation. If your project requires redundant I\/O or fused power distribution, ensure you have selected the appropriate MTU (such as the \u003cspan\u003eTU830\u003c\/span\u003e) for the \u003cspan\u003e3BSE008544R1\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration Logic:\u003c\/span\u003e In the control system software (e.g., Control Builder M), ensure each channel is correctly mapped to its specific signal range. Incorrect software scaling can lead to \"Out of Range\" errors even if the physical field wiring is correct.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShielding Protocol:\u003c\/span\u003e To maximize the benefits of the module's 50V CMV protection, field cables should be shielded. Terminate the shields at the designated grounding points on the MTU to minimize electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eABB 3BSE008544R1\u003c\/span\u003e provides a robust, space-efficient solution for analog data acquisition. Its ability to handle bipolar signals and provide per-channel isolation reduces the need for external signal conditioners and isolators, lowering the overall cost of the control cabinet. For B2B procurement, choosing the original \u003cspan\u003e3BSE008544R1\u003c\/span\u003e ensures full compatibility with the \u003cspan\u003e800xA\u003c\/span\u003e lifecycle and maintains the industrial certifications (CE, RoHS) required for global process safety and environmental compliance.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959684459,"sku":"3BSE008544R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse008544r1-vc5fhauapdb_d752756a-b34e-4766-9f04-19ef03e8f10b.jpg?v=1766478192"},{"product_id":"abb-s800-i-o-3bse020838r1-do840-digital-output-module","title":"Mô-đun Đầu ra Kỹ thuật số ABB S800 I\/O 3BSE020838R1 DO840","description":"\u003ch3\u003eTổng Quan Mô-đun Đầu Ra Kỹ Thuật Số S800 I\/O\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003e3BSE020838R1 (DO840)\u003c\/strong\u003e là mô-đun đầu ra kỹ thuật số độ tin cậy cao trong hệ thống S800 I\/O của ABB, được thiết kế cho các ứng dụng tự động hóa công nghiệp và điều khiển quy trình.\nNó cung cấp 16 kênh đầu ra transistor 24V DC với chẩn đoán nâng cao và các tùy chọn dự phòng linh hoạt.\n\u003c\/p\u003e\n\n\u003cp\u003e\nMô-đun được thiết kế cho các môi trường điều khiển khắt khe, nơi hiệu suất chuyển mạch ổn định, cách ly kênh và chẩn đoán hệ thống là rất quan trọng.\nNó được sử dụng rộng rãi trong kiến trúc ABB 800xA và Compact Product Suite để điều khiển các bộ truyền động, solenoid và hệ thống liên động trong các hoạt động công nghiệp liên tục.\n\u003c\/p\u003e\n\n\u003ch3\u003eKiến Trúc Hệ Thống \u0026amp; Thiết Kế Chức Năng\u003c\/h3\u003e\n\n\u003cp\u003e\nDO840 được thiết kế tập trung vào cách ly kênh, dự phòng mô-đun và minh bạch chẩn đoán:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCấu Hình Kênh:\u003c\/strong\u003e 16 đầu ra kỹ thuật số chia thành 2 nhóm cách ly, mỗi nhóm 8 kênh.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHỗ Trợ Dự Phòng:\u003c\/strong\u003e Hỗ trợ cấu hình hệ thống đơn và dự phòng cho các ứng dụng yêu cầu độ sẵn sàng cao.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCông Suất Đầu Ra:\u003c\/strong\u003e 0,5A mỗi kênh để chuyển mạch thiết bị hiện trường đáng tin cậy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChẩn Đoán Trên Bo Mạch:\u003c\/strong\u003e Chẩn đoán nâng cao cho phép phát hiện lỗi thời gian thực và giám sát từng kênh.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTích Hợp Mô-đun:\u003c\/strong\u003e Thiết kế cho giá đỡ S800 I\/O và tương thích với hệ thống ABB 800xA và Compact Product Suite.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDữ Liệu Điện \u0026amp; Cơ Khí\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMã Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE020838R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại ABB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDO840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại Sản Phẩm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMô-đun Đầu Ra Kỹ Thuật Số\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSố Kênh Đầu Ra\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (2 nhóm cách ly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoại Kênh\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐầu Ra Kỹ Thuật Số 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDòng Đầu Ra\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,5 A mỗi kênh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCách Ly Nguồn\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCách Ly Nhóm (2 × 8 kênh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKích Thước\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 × 119 × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrọng Lượng Tịnh\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTuân Thủ RoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTuân thủ (Chỉ thị EU 2011\/65\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eỨng Dụng \u0026amp; Ghi Chú Vận Hành\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eDO840 có thể hoạt động trong cấu hình dự phòng không?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCó. Mô-đun hỗ trợ cấu hình dự phòng khi sử dụng với kiến trúc hệ thống S800 I\/O tương thích, đảm bảo độ sẵn sàng hệ thống cao trong các ứng dụng điều khiển quy trình quan trọng.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoại tải nào mà các đầu ra có thể điều khiển?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nMỗi kênh hỗ trợ tải 24V DC lên đến 0,5A, thường dùng cho solenoid, rơ-le, đèn báo và các thiết bị truyền động nhỏ trong hệ thống tự động hóa.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThông tin chẩn đoán được cung cấp như thế nào?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nMô-đun bao gồm chẩn đoán nâng cao trên bo mạch báo cáo lỗi kênh, trạng thái truyền thông và điều kiện nguồn điện trực tiếp đến hệ thống điều khiển.\n\u003c\/p\u003e\n\n\u003ch3\u003eHướng Dẫn Lắp Đặt \u0026amp; Kỹ Thuật\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eTương Thích MTU:\u003c\/strong\u003e\u003cbr\u003e\nDO840 phải được lắp đặt với các Đơn Vị Kết Thúc Mô-đun (TU810, TU812, TU814, TU830, TU833, TU842, TU843, TU852) tương thích.\nLựa chọn MTU phù hợp đảm bảo mật độ dây đúng và độ tin cậy hệ thống.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCách Ly Dây:\u003c\/strong\u003e\u003cbr\u003e\nCác đầu ra được chia thành hai nhóm cách ly. Giữ khoảng cách thích hợp để tránh nhiễu chéo và đảm bảo tính toàn vẹn tín hiệu trong tủ có mật độ cao.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuản Lý Nhiệt:\u003c\/strong\u003e\u003cbr\u003e\nMặc dù mô-đun có công suất tỏa nhiệt thấp, hãy đảm bảo thông gió tủ thích hợp khi nhiều mô-đun I\/O được lắp đặt gần nhau.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTích Hợp Hệ Thống:\u003c\/strong\u003e\u003cbr\u003e\nKhi sử dụng trong hệ thống 800xA, đảm bảo cấu hình I\/O chính xác trong phần mềm điều khiển để kích hoạt đầy đủ các tính năng chẩn đoán và dự phòng.\n\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959782763,"sku":"3BSE020838R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse020838r1-vprkccjumrg_a3901b93-cbb8-4578-9972-b342a76e0e19.jpg?v=1766478195"},{"product_id":"abb-do820-s800-i-o-8-channel-digital-output-relay-module-3bse008514r1","title":"ABB DO820 S800 I\/O 8-Channel Digital Output Relay Module 3BSE008514R1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\nThe \u003cstrong\u003e3BSE008514R1 (DO820)\u003c\/strong\u003e is a high-density, 8-channel digital output relay module within the ABB S800 I\/O family. \nEngineered for maximum versatility in industrial automation, this module provides high-current switching capabilities for both AC and DC loads. \nIts primary strength lies in its individually galvanic isolated channels, making it an ideal choice for diverse control applications where different voltage potentials or electrical isolation between circuits are required.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWhether integrated into the Advant OCS, 800xA, or Compact Product Suite systems, the DO820 serves as a robust interface for driving solenoids, motor starters, and actuators. \nIt enhances system reliability by protecting sensitive control electronics from field-side electrical noise and surges.\n\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\nThe DO820 is designed for seamless integration and rugged performance in demanding DCS and PLC environments:\n\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Supports 24 to 230 VAC\/VDC, with a maximum current rating of 3 A per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Each channel is individually isolated, allowing mixed voltage types within a single module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Management:\u003c\/strong\u003e Optimized for switching loads with a power factor (cos φ) greater than 0.4 and a DC rating of 42 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Compatibility:\u003c\/strong\u003e Works with MTUs including TU811, TU813, TU831, TU836, TU837, and TU851.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDO820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE008514R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEstonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay (8 Channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 to 230 VAC \/ 24 to 230 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually Galvanic Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm × 119 mm × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the DO820 handle different voltage sources on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nYes. Because each channel is individually galvanic isolated, you can switch 230 VAC on one channel and 24 VDC on another without electrical interference.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat happens if I exceed the 3 A current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nRelay contacts may experience arcing or welding if overloaded. For loads exceeding 3 A, use an external interposing relay or apply proper surge suppression.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhich Module Termination Unit (MTU) should I use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nSelection depends on wiring density and safety requirements. TU811 is a standard compact MTU, while TU813 and TU831 provide alternative terminal configurations.\n\u003c\/p\u003e\n\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eArc Suppression:\u003c\/strong\u003e\u003cbr\u003e\nInstall a flyback diode for DC inductive loads. For AC loads, use an RC snubber to extend relay contact life.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cbr\u003e\nIf all eight channels operate at maximum current simultaneously, ensure adequate cabinet ventilation to prevent heat buildup.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e\u003cbr\u003e\nMount vertically on a DIN rail via the compatible MTU. Confirm the locking mechanism is fully engaged to avoid vibration-related contact issues.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHot Swapping:\u003c\/strong\u003e\u003cbr\u003e\nS800 I\/O modules support HCIR, but always disconnect field power or ensure the process is in a safe state before removal.\n\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701960470891,"sku":"3BSE008514R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse008514r1-qymczgq33si_eb5fc5e7-ca97-49de-8270-39f145b84237.jpg?v=1766478216"},{"product_id":"abb-ai835a-3bse051306r1-s800-i-o-8-channel-thermocouple-input-module","title":"ABB AI835A 3BSE051306R1 S800 I\/O 8-Channel Thermocouple Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB AI835A is an 8-channel analog input module for S800 I\/O systems.\u003cbr\u003eIt supports thermocouple and mV signal acquisition across multiple TC types for accurate temperature monitoring.\u003cbr\u003eMoreover, it is compatible with System 800xA, Advant OCS, and Compact Product Suite for flexible industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI835A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e3BSE051306R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Analog Inputs (Thermocouple\/mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouples\u003c\/td\u003e\n\u003ctd\u003eB, C, D, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, AC 800M Controllers, System 800xA, Advant OCS, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eRack-mounted analog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring\u003c\/td\u003e\n\u003ctd\u003eRequires compatible MTU (TU810, TU812, TU814, TU818, TU830, TU833)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial temperature measurement and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple signal acquisition for process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized or distributed control architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with System 800xA, Advant OCS, or Compact Product Suite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density analog input solutions for mission-critical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701961060715,"sku":"3BSE051306R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse051306r1-0sie0wwls02_e66f7065-a2c3-4c68-ac32-15de3e1d5178.jpg?v=1766478234"},{"product_id":"abb-3bse022366r1-ci801-profibus-dp-s800-i-o-interface-module","title":"ABB 3BSE022366R1 CI801 PROFIBUS DP S800 I\/O Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI801 (3BSE022366R1) is a PROFIBUS DP Field Communication Interface for S800 I\/O systems.\u003cbr\u003eIt enables efficient I\/O scanning, configuration, and diagnostics across S800 clusters with seamless network integration.\u003cbr\u003eMoreover, it includes essential accessories for immediate installation and reliable operation in System 800xA environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eField Communication Interface Module (FCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e3BSE022366R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O System (System 800xA 4.0–6.0, Compact Product Suite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003e1x Power Supply Connector, 1x TB807 Modulebus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eRail-mounted interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e85.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth\u003c\/td\u003e\n\u003ctd\u003e58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePROFIBUS DP integration for S800 I\/O clusters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial field device communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData exchange between controllers and I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem 800xA and Compact Product Suite architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl system expansion and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701961355627,"sku":"3BSE022366R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse022366r1-5nxxhp2kzr5_9ebb8c2d-c7df-464d-97a7-3fffb5635b47.jpg?v=1766478242"},{"product_id":"abb-tu812v1-3bse013232r1-s800-i-o-compact-mtu-50v-d-sub","title":"ABB TU812V1 3BSE013232R1 S800 I\/O Compact MTU 50V D-sub","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB TU812V1 is a compact Module Termination Unit designed for S800 I\/O field wiring applications.\u003cbr\u003eIt provides a 25-pin D-sub interface for efficient signal termination while supporting 50 V isolation ratings.\u003cbr\u003eMoreover, it enables dense I\/O installation and straightforward maintenance across System 800xA environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact Module Termination Unit (MTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU812V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013232R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eRail-mounted MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e25-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Gender\u003c\/td\u003e\n\u003ctd\u003eMale on unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA, Advant OCS, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85371098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e58.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eS800 I\/O field wiring termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density control cabinet installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation systems using System 800xA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl system expansion and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact I\/O marshalling solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701961388395,"sku":"3BSE013232R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013232r1-s3yu1yvhoyv_71c7e7ef-9aa8-4f6a-a45f-5c74241f5855.jpg?v=1766478243"},{"product_id":"abb-ao815-3bse052605r1-s800-analog-output-hart-module","title":"ABB AO815 3BSE052605R1 S800 Analog Output HART Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB AO815 (3BSE052605R1) is an 8-channel analog output module with HART communication.\u003cbr\u003eIt provides precise 4–20 mA control signals with 12-bit resolution for industrial devices.\u003cbr\u003eMoreover, it integrates seamlessly with ABB System 800xA and Compact Product Suite for high-density cabinet mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eS800 Analog Output HART Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Type Designation\u003c\/td\u003e\n\u003ctd\u003eAO815\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE052605R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Channels (4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Resistance (RLmax)\u003c\/td\u003e\n\u003ctd\u003e750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e45 × 119 × 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O System 800xA v4.1–6.0, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eUse with MTU TU810, TU812, TU814, TU830, or TU833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS 2011\/65\/EU, WEEE Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003e\u0026lt;ul\u0026gt; \u0026lt;li\u0026gt;Control of field devices such as valves, actuators, and process instruments\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;High-density I\/O cabinets in industrial automation systems\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;ABB System 800xA and Compact Product Suite integration\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Process control requiring precise analog output signals\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;HART-enabled devices for advanced diagnostics and communication\u0026lt;\/li\u0026gt; \u0026lt;\/ul\u0026gt;\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701961978219,"sku":"3BSE052605R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse052605r1-33svhhsx4qn_d84786f5-2e23-4b20-98f7-e810f3856a67.jpg?v=1766478256"},{"product_id":"abb-di814-3bur001454r1-s800-digital-input-module","title":"ABB DI814 3BUR001454R1 S800 Digital Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB DI814 is a 16-channel 24V DC digital input module for the S800 I\/O system.\u003cbr\u003eIt features current sourcing inputs isolated into two groups of 8 channels for signal integrity.\u003cbr\u003eMoreover, it is compatible with System 800xA, Advant OCS, and Compact Product Suite environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Type Designation\u003c\/td\u003e\n\u003ctd\u003eDI814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BUR001454R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eTwo groups of 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eRack-mounted digital input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired MTU\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830, TU833, TU838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e45 × 119 × 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA 4.0–6.0, Advant OCS, Advant Fieldbus 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003e\u0026lt;ul\u0026gt; \u0026lt;li\u0026gt;Industrial process monitoring and control\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Sequence of digital inputs in S800 I\/O systems\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;System 800xA and Advant OCS integration\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Compact control cabinet installations\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;High-reliability automation environments\u0026lt;\/li\u0026gt; \u0026lt;\/ul\u0026gt;\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701962305899,"sku":"3BUR001454R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bur001454r1-3rrsao03ccs_a61a2ea3-3ffd-48f4-bada-66da8c25df85.jpg?v=1766478262"},{"product_id":"abb-di885-3bse013088r1-s800-digital-input-module-8-ch-24-48v-soe","title":"ABB DI885 3BSE013088R1 S800 Digital Input Module 8-Ch 24\/48V SOE","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB DI885 is an 8-channel digital input module for S800 I\/O systems with Sequence of Events (SOE) functionality.\u003cbr\u003eIt operates at 24V or 48V DC, providing precise timing for fault analysis and process diagnostics.\u003cbr\u003eMoreover, it is compatible with ABB System 800xA, Advant OCS, and Compact Product Suite environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Type Designation\u003c\/td\u003e\n\u003ctd\u003eDI885\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE013088R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24V \/ 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eSequence of Events (SOE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Isolation\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance \/ Usage\u003c\/td\u003e\n\u003ctd\u003eService spare part for legacy systems pre-July 2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Module Termination Units\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eRack-mounted digital input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e45 × 119 × 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eNot compliant (legacy spare part only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003e\u0026lt;ul\u0026gt; \u0026lt;li\u0026gt;Sequence of Events (SOE) monitoring\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Industrial process fault analysis\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Legacy ABB System 800xA and Advant OCS installations\u0026lt;\/li\u0026gt; \u0026lt;li\u0026gt;Maintenance, repair, and functional upgrades for existing control systems\u0026lt;\/li\u0026gt; \u0026lt;\/ul\u0026gt;\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701962338667,"sku":"3BSE013088R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013088r1-c40g2320wdy_ae1aceb1-5525-4bcb-b75c-48cf47549168.jpg?v=1766478263"}],"url":"https:\/\/www.plcprotech.com\/vi\/collections\/abb-s800-i-o.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}