{"title":"Allen-Bradley MicroLogix","description":"\u003cp\u003eThe Allen-Bradley MicroLogix family (1761, 1762, 1763, 1764, 1766) offers a proven range of small, standalone controllers for basic machine automation. The architecture ranges from fixed I\/O blocks to modular expansion systems, providing flexibility for varied machine sizes. Technical characteristics include integrated high-speed counters, serial or Ethernet ports, and an embedded LCD for localized diagnostics. Functionally, MicroLogix excels in small-scale applications like conveyor control, packaging, and basic SCADA RTU tasks. While transitioning toward the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-micro800\"\u003eMicro800\u003c\/a\u003e series, these robust controllers remain a staple for thousands of industrial systems, requiring reliable spare parts to maintain consistent operational uptime.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1766-l32bxba-micrologix-1400-32-point-controller","title":"Allen-Bradley 1766-L32BXBA MicroLogix 1400 32 Point Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1766-L32BXBA\u003c\/strong\u003e is a programmable logic controller within the \u003cstrong\u003eMicroLogix 1400\u003c\/strong\u003e series designed for industrial automation applications requiring a high density of discrete and analog control paths. This controller operates on a 24V DC power supply and manages a total embedded array of 32 digital points alongside integral analog processing modules. The discrete input capabilities include 12 fast 24V DC inputs and 8 standard 24V DC inputs, which couple with 6 relay outputs, 3 fast 24V DC outputs, and 3 normal 24V DC FET outputs. Furthermore, the unit integrates 4 embedded 12-bit voltage inputs and 2 embedded 12-bit analog outputs, removing the necessity for supplementary hardware modules in basic mixed-signal tracking routines. Outfitted with an isolated Ethernet port, the system facilitates industrial protocol communications including EtherNet\/IP messaging, Modbus TCP\/IP, and DNP3 over IP, ensuring full compatibility with supervising workstation infrastructures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates a diverse embedded multi-channel mix comprising 20 digital inputs, 12 digital outputs, 4 analog inputs, and 2 analog outputs.\u003c\/li\u003e\n\u003cli\u003eFeatures 12 high-speed discrete inputs and 3 fast FET outputs for rapid signal execution.\u003c\/li\u003e\n\u003cli\u003eProvides dual discrete output topologies utilizing both rugged isolation relays and fast-switching 24V DC FET channels.\u003c\/li\u003e\n\u003cli\u003eOutfitted with an isolated Ethernet port supporting multi-protocol network integration alongside serial interface capabilities.\u003c\/li\u003e\n\u003cli\u003eContains 20 KB of internal memory to process user control logic applications safely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmbedded system automation loops requiring localized mixing of high-speed discrete and analog instrumentation.\u003c\/li\u003e\n\u003cli\u003eSCADA remote terminal units utilizing DNP3 or Modbus communication configurations across water, wastewater, or utility infrastructures.\u003c\/li\u003e\n\u003cli\u003eLocalized material handling conveyors, packaging machinery control panels, and process pump skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1766-L32BXBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Input channels, 12 Output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 fast 24V DC inputs, 8 normal 24V DC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 relay outputs, 3 fast 24V DC outputs, 3 normal 24V DC FET outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Voltage Inputs (12 bits) \/ 2 Analog Outputs (12 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Relay and 6 24V DC FET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDF1, DH-485, Modbus RTU, ASCII, DNP3, EtherNet\/IP messaging, DNP3 over IP, Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet Port, Isolated Serial Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm (3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mm (7.087 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 mm (3.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller housing securely onto a standard industrial DIN rail structure inside an environmental protective control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming auxiliary power link delivers a regulated 24V DC voltage source matching the strict electrical profile of the hardware terminal blocks.\u003c\/li\u003e\n\u003cli\u003eSeparate instrumentation signaling lines, particularly the integrated 12-bit analog input and output loops, from neighboring high-voltage electrical lines to decrease noise coupling risks.\u003c\/li\u003e\n\u003cli\u003eGround the controller chassis using the dedicated grounding terminal path to guarantee reliable internal diagnostic operations and optimize electrostatic immunity thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695173759339,"sku":"1766-L32BXBA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1766-l32bxba-micrologix-1400-plc-1nsjzz1wqgz_c02cd092-d614-41fb-a7b2-43f9cc939a28.jpg?v=1766114468"},{"product_id":"allen-bradley-1761-net-aic-aic-advanced-interface-converter","title":"Allen-Bradley 1761-NET-AIC AIC+ Advanced Interface Converter","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003eAllen-Bradley 1761-NET-AIC\u003c\/strong\u003e is a high-performance \u003cstrong\u003eAIC+ advanced interface converter\u003c\/strong\u003e engineered to provide a reliable, isolated electronic communication link between various networked automation components. Operating as an intelligent protocol and physical layer adapter, the module features built-in electrical isolation to establish point-to-point or multidrop routing across diverse serial networks without risking ground loop faults. By utilizing dual RS-232 pathways combined with a dedicated RS-485 port interface, this device smoothly links controllers, personal computer configurations, operator terminals, and modems across demanding shop floor networks.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTriple Port Interface:\u003c\/strong\u003e Integrated architecture offering one RS-485 Phoenix plug connection, an 8-pin mini-DIN RS-232 port, and a conventional 9-pin DB-9 DTE RS-232 communication port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Electrical Isolation:\u003c\/strong\u003e Delivers 500V DC internal electrical isolation boundary limits between all communication ports and the active power supply terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Operational Clocking:\u003c\/strong\u003e Built-in communication-rate selector switch supports distinct transmission steps including 1200, 2400, 4800, 9600, 14400, and 19200 bps, alongside an automated AUTO position mode.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdaptable Power Sourcing:\u003c\/strong\u003e Built-in DC power-source selector switch allows the module to extract active power directly from a connected MicroLogix controller or use external 24V DC auxiliary block terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Networking Range:\u003c\/strong\u003e Extends a standard DH-485, DF1, or user network multidrop segment up to 1219 m (4000 ft) with a total allowance of up to 32 nodes per network link.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eMultidrop DH-485 or DF1 industrial network extensions connecting modular SLC 500 and compact MicroLogix controller nodes.\u003c\/li\u003e\n  \u003cli\u003eIsolation interfaces between local supervisory computer workstations (PC serial COM ports) and high-voltage factory networks.\u003c\/li\u003e\n  \u003cli\u003eDistributed multi-node configurations linking remote PanelView operator graphic terminals to distributed control backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCatalog Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1761-NET-AIC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAIC+ Advanced Interface Converter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e24V DC Power Source Requirement\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20.4 to 28.8V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Draw\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 120 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInrush Current (Max.)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e200 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInternal Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e500V DC between all ports and power supply terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported Network Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDH-485, DF1, or User Network ASCII\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Nodes per Multidrop Link\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e32 nodes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Network Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1219 m (4000 ft) per multidrop network\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMax. Ganged Multidrop Networks\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommunication Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1200, 2400, 4800, 9600, 14400, 19200 bps and AUTO\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 85 degC (-40 to 175 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDescription \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-485 Port (Phoenix Plug)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTerminal 1: Chassis Ground | Terminal 2: Shield | Terminal 3: Common | Terminal 4: B | Terminal 5: A | Terminal 6: Termination\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-232 Port (8-pin mini-DIN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary communication connection designed to interface with MicroLogix controllers; capable of drawing internal operational power.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRS-232 Port (DB-9, DTE)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eStandard 9-pin serial layout matching personal computer COM channels, PanelView graphic units, modems, or alternative DTE lines.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExternal Power Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew block connection points for dedicated auxiliary external 24V DC supply lines and structural ground wire runs.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eATTENTION: EXPLOSION HAZARD.\u003c\/strong\u003e Substitution of components may impair suitability for Class I, Division 2 environments. Do not replace components or disconnect equipment unless power has been switched off or the installation area is known to be nonhazardous. Do not operate switches or mating cables while the circuit is live.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eEnclosure Selection:\u003c\/strong\u003e Install the interface converter inside a protective industrial enclosure. All interconnecting data cables must remain housed within the enclosure or be shielded using rigid electrical conduit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eDIN Rail Assembly:\u003c\/strong\u003e Snap the converter housing directly onto a standardized top-hat style DIN rail channel, or mount it securely to a backpanel plane using the integrated mounting feet holes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003ePower Switch Selection:\u003c\/strong\u003e Position the DC power-source selector switch before activating the lines. Set the switch to EXTERNAL when using independent 24V DC terminal feeds, or set it to CABLE if deriving internal power directly from a MicroLogix 8-pin mini-DIN cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eRS-485 Cable Termination:\u003c\/strong\u003e For end-of-line nodes on a daisy-chained RS-485 trunk line using Belden #3106A or #9842 cable, connect a short wire jumper between Terminal 1 (Chassis Ground) and Terminal 2 (Shield) on one end to provide a single, secure earth path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003e\u003cstrong\u003eBaud Rate Optimization:\u003c\/strong\u003e Keep the communication-rate selector switch set to the AUTO position for standard installations. In environments with severe electromagnetic noise or interference, switch it to manual and set it to match the exact fixed baud rate of the network.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eUL 1604 Standard\u003c\/li\u003e\n  \u003cli\u003eC-UL C22.2 No. 213\u003c\/li\u003e\n  \u003cli\u003eClass I, Division 2, Groups A, B, C, D Hazardous Locations\u003c\/li\u003e\n  \u003cli\u003eCE Compliant (Council Directive 89\/336\/EEC EMC \/ Council Directive 73\/23\/EEC Low Voltage)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695180935531,"sku":"1761-NET-AIC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-net-aic-micrologix-and-slc-communication-adaptor-z0toe1mj3ov_ea878e4d-8e8f-4925-9659-179743b23b9f.jpg?v=1766114284"},{"product_id":"allen-bradley-1761-l16bwb-micrologix-1000-programmable-controller","title":"Allen-Bradley 1761-L16BWB MicroLogix 1000 Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003e1761-L16BWB\u003c\/strong\u003e is a compact \u003cstrong\u003eprogrammable controller\u003c\/strong\u003e belonging to the MicroLogix 1000 product line. This electronic processor functions as a localized control block designed to modernize hardwired control logic systems within machine control configurations, localized factory automation setups, and designated process loops. Powered by an external 24V DC utility framework, the module maintains direct discrete tracking through integrated digital channels, executing instruction words via internal memory logic blocks.\u003c\/p\u003e\n\u003cp\u003eTo enable technical updates, diagnostic tracing, and commissioning loops, the \u003cstrong\u003e1761-L16BWB\u003c\/strong\u003e features an RS232 serial communication interface supporting the native DF1 protocol format. This dedicated connection port allows cross-system link setups to Human Machine Interfaces (HMI), Supervisory Control and Data Acquisition (SCADA) packages, and peripheral hardware converters. The controller can also adapt to external multi-node DH485 networks using a separate advanced interface converter or execute adjustments through a physical hand-held setup interface.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 16-point integrated I\/O configuration optimizing local physical space.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication channel backing native serial point-to-point interface.\u003c\/li\u003e\n\u003cli\u003eDual sinking and sourcing wiring options for versatile sensor configuration.\u003c\/li\u003e\n\u003cli\u003eInternal EEPROM storage framework ensuring reliable parameter preservation without battery dependencies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery manufacturing and localized operational line sequencing.\u003c\/li\u003e\n\u003cli\u003eFactory floor process automation nodes.\u003c\/li\u003e\n\u003cli\u003eWater, wastewater treatment, and HVAC equipment control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSeries \/ Revision Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser A\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/A, Series A, Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser B\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/B, Series B, Rev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser C\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/C, Series C, Rev C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser D\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/D, Series D, Rev D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1761-L16BWB Ser E\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\/E, Series E, Rev E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller (PLC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1761-L16BWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468554497\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Count\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e20.4-26.4V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30A for 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Inputs\u003c\/td\u003e\n\u003ctd\u003eTen (10); Sinking \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003e14 - 30V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e24V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSix (6); Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Contact Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Size and Type\u003c\/td\u003e\n\u003ctd\u003e1 K EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003eApprox. 737 instruction words and 437 data words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eDF1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Feature\u003c\/td\u003e\n\u003ctd\u003eMaster Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Cycles\u003c\/td\u003e\n\u003ctd\u003e50,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e10 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e20 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 lbs (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller securely in a horizontal orientation to ensure proper ventilation and thermal cooling across internal electronic elements.\u003c\/li\u003e\n\u003cli\u003eRoute all low-voltage signal wiring separately from high-voltage electrical lines to eliminate signal crossover or EMI\/RFI noise distortion.\u003c\/li\u003e\n\u003cli\u003eEstablish a direct, low-impedance ground connection from the chassis earth terminal to the main system enclosure backplane.\u003c\/li\u003e\n\u003cli\u003eEnsure power sourcing requirements match the specified 20.4-26.4V DC bounds before energizing input terminal rows.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181459819,"sku":"1761-L16BWB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1761-l16bwb-micrologix-1000-controller-hn1dzc0nzcf_3354eb5a-107e-4225-932b-c0f7f3df0621.jpg?v=1766114303"},{"product_id":"1763-l16bbb-allen-bradley-micrologix-1100-16-point-plc-controller","title":"1763-L16BBB Allen-Bradley MicroLogix 1100 16-Point PLC Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-946\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1763-L16BBB (1763L16BBB)\u003c\/strong\u003e\u003cspan class=\"citation-946 citation-end-946\"\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile, compact controller within the MicroLogix 1100 family, designed to provide high-end features like online editing and built-in Ethernet\/IP at a micro-PLC price point.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 16 integrated I\/O points (comprising 10 digital inputs, 2 analog inputs, and 6 digital outputs), this unit is a preferred choice for remote monitoring stations, building automation, and distributed control in the oil and gas sector. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eempowers engineers to make real-time programming changes without shutting down the process, effectively eliminating downtime during commissioning.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-945 citation-end-945\"\u003eIts integrated LCD screen provides immediate diagnostic feedback and allows for the adjustment of internal integer and bit files without the need for an external HMI.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-944\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan class=\"citation-944 citation-end-944\"\u003e\u003cspan\u003e \u003c\/span\u003eis powered by a 24 VDC supply and features a sophisticated I\/O arrangement.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-943 citation-end-943\"\u003eThe input section consists of ten 24 VDC digital inputs, including four high-speed inputs (40 kHz) capable of high-frequency pulse counting and motion sensing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-942 citation-end-942\"\u003eAdditionally, it provides two 10-bit analog voltage inputs (0-10 VDC) integrated directly into the base.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe output side is optimized for high-speed switching and flexibility, featuring two 24 VDC FET outputs and four isolated relay outputs.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-941 citation-end-941\"\u003eFor connectivity, the controller boasts dual communication ports: an isolated RS-232\/RS-485 combo port and a full-featured 10\/100 Mbps EtherNet\/IP port, supporting peer-to-peer messaging and remote programming across local or wide-area networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1763-L16BBB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Singapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 (24 VDC Sink\/Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (0-10 VDC, 10-bit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 24 VDC FET \/ 4 Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Speed I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Inputs (40 kHz) \/ 2 Outputs (40 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 KB (4 KB User Program \/ 4 KB User Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet\/IP, RS-232, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1763-L16BBB be used for high-speed motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the controller features two high-speed PTO (Pulse Train Output) or PWM (Pulse Width Modulation) outputs via its FET channels. These are ideal for basic stepper motor control or proportional valve modulation in compact machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Ethernet port compatible with standard office networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EtherNet\/IP port uses standard RJ45 connectors and TCP\/IP protocols. However, for industrial reliability, it is recommended to use shielded Cat5e or Cat6 cabling to prevent signal drops caused by high-voltage motor cables or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat expansion modules are compatible with this base controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports up to four 1762 series expansion I\/O modules. These modules connect to the right side of the controller via a bus interface, allowing for additional digital, analog, or temperature-sensing (TC\/RTD) points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFET Output Polarity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the two 24 VDC FET outputs, ensure that the polarity is strictly observed. Unlike relay outputs, FET outputs are solid-state and polarity-sensitive. Reversing the 24 VDC supply or the load connection can cause immediate failure of the output circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Signal Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe two embedded 0-10 VDC analog inputs share a common return and provide 10-bit resolution. For precision applications requiring 12-bit or 16-bit accuracy, or for 4-20 mA signals, use a 1762-IF4 expansion module instead of the built-in terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Editing Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1763-L16BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports online editing, engineers should verify all rung logic changes in a simulation environment before applying them to a live process. Sudden changes in timer values or output states during a machine cycle can lead to mechanical stress or safety hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough rated for up to 65 deg C, if the controller is installed in an outdoor enclosure (e.g., a wellhead site), ensure the cabinet is vented or equipped with a heat sink to prevent the internal LCD from fading due to prolonged exposure to extreme thermal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183556971,"sku":"Allen Bradley 1763-L16BBB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1763-l16bbb-micrologix-1100-16-point-controller-ppiovh01k0k_a3109e4e-ee9e-496a-acd3-e193fb8ecae5.jpg?v=1766114381"},{"product_id":"1764-24awa-allen-bradley-micrologix-1500-24-point-base-unit","title":"1764-24AWA Allen-Bradley MicroLogix 1500 24-Point Base Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA (176424AWA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-density foundational base for the Allen-Bradley MicroLogix 1500 controller system. This 120\/240 VAC powered unit features 24 integrated I\/O points, specifically designed to bridge the gap between compact micro-PLCs and larger modular systems. Ideal for distributed control in wastewater management, pharmaceutical secondary packaging, and precision assembly lines, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential power supply and I\/O interface required to support a 1764-LRP or 1764-LSP processor. By decoupling the processor from the I\/O base, this architecture allows for rapid maintenance and upgrades with zero rewiring, significantly lowering the Total Cost of Ownership (TCO) and reducing critical system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a split-architecture design where the base unit contains the power supply, input\/output circuitry, and expansion ports. It is equipped with 12 isolated 120 VAC inputs and 12 relay outputs, making it natively compatible with high-voltage field devices without requiring interposing relays. The unit features an integrated expansion port that supports up to 16 Compact I\/O (1769 series) modules, allowing for massive scalability. The internal power supply is engineered to handle industrial-grade voltage fluctuations, while the relay outputs are rated for heavy-duty cycling, ensuring long-term mechanical reliability in high-vibration or high-cycle environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1764-24AWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Singapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85-265 VAC (47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (120 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpansion Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 1769 Compact I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e138 x 168 x 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I operate the 1764-24AWA base unit without a processor module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a base unit only. It requires a 1764-LSP or 1764-LRP processor module plugged into the front interface to function as a complete programmable logic controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum output current rating for the relay contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay outputs on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare typically rated for a continuous current of 2.0 A per point, with a maximum controlled load of 1440 VA for AC. Always verify your specific inductive load requirements against the NEMA ICS ratings provided in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to mix AC and DC expansion modules with this AC base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the base unit uses 120 VAC inputs, you can add 1769 series Compact I\/O expansion modules (Digital DC, Analog, or Thermocouple) to the right side of the unit to accommodate diverse field signal requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Hot-Plugging Warning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNever attempt to install or remove the 1764-LSP\/LRP processor module while power is applied to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebase. This can cause electrical arcing across the backplane pins, potentially corrupting the processor memory or causing permanent hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Bus Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen expanding the system with 1769 Compact I\/O modules, ensure that a 1769-ECR or 1769-ECL end cap is securely installed at the end of the I\/O bank. Without the end cap, the I\/O bus will remain an open circuit, and the processor will flag a major non-recoverable fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven that this base unit utilizes relay outputs, switching inductive loads (such as motor contactors or solenoids) generates significant Back-EMF. It is mandatory to install MOV (Metal Oxide Varistors) or RC snubbers across AC loads to prevent electromagnetic interference from resetting the internal processor logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695183917419,"sku":"Allen Bradley 1764-24AWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1764-24awa-micrologix-1500-base-unit-imukxjybyqv_3cbde214-b442-4ab1-9bb5-ec02af3178b7.jpg?v=1766114395"},{"product_id":"allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller","title":"Allen-Bradley 1762-L40BWA MicroLogix 1200 40 Point Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-931\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1762-L40BWA (1762L40BWA)\u003c\/strong\u003e\u003cspan class=\"citation-931 citation-end-931\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact programmable logic controller within the MicroLogix 1200 family, engineered to handle complex industrial applications with a small physical footprint.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFeaturing 40 integrated I\/O points (24 inputs and 16 outputs), this controller is a staple in critical infrastructure such as municipal water pumping stations, material handling conveyors, and specialized packaging machinery. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the processing power necessary to reduce cycle times and optimize throughput. Its robust design ensures high reliability in demanding environments, minimizing unplanned downtime and maintaining system stability in 120\/240 VAC powered architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware architecture is designed for versatility and expansion.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-930 citation-end-930\"\u003eIt features 24 VDC sink\/source inputs and highly durable relay outputs, allowing it to interface directly with various field devices.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-929 citation-end-929\"\u003eThe unit is powered by a 120\/240 VAC supply, eliminating the need for external DC power modules for the base controller operation.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCommunication is handled via an isolated RS-232 port, supporting DF1, DH-485, and Modbus RTU protocols for seamless integration into existing SCADA or HMI networks. The controller’s memory is flash-based, protecting user programs and data without the absolute necessity of battery backup, though a battery (1747-BA) is supported for long-term data retention.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1762-L40BWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Malaysia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Sink\/Source (24 points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay (16 points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100-240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 KB (approx. 4 KB Instruction\/2 KB Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (8-pin mini-DIN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 x 160 x 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-L40BWA support I\/O expansion beyond the built-in 40 points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MicroLogix 1200 series supports up to six 1762 expansion I\/O modules. These modules are connected via a ribbon cable on the right side of the unit, allowing for a significant increase in digital or analog point counts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required to program this specific controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis programmed using RSLogix 500 software or MicroLogix-specific versions of the same suite. It is compatible with Windows-based environments and utilizes a standard ladder logic programming structure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I reset the controller to factory defaults if the password is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eResetting the controller usually requires a specific memory clearing procedure or a factory-authorized \"Master Password\" depending on the firmware version. Note that a factory reset will erase all stored ladder logic and data tables.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Output Longevity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo extend the life of the internal relay contacts, always install an external suppression circuit (such as an RC snubber for AC loads or a diode for DC loads) when switching inductive loads like solenoids or motor starters. This prevents contact arcing and premature failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail and Panel Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the unit supports DIN rail mounting, for high-vibration environments (such as rock crushing or heavy stamping), it is recommended to use the integrated screw mounting holes for a more secure, direct-to-panel installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Noise Reduction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the \"Chassis Ground\" terminal is connected to a low-impedance earth ground using a short, heavy-gauge wire. This is critical for protecting the internal 24 VDC sensor power supply and ensuring stable RS-232 communication signals in electrically noisy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188537707,"sku":"1762-L40BWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1762-l40bwa-micrologix-1200-40-point-controller-ed4xi5bj2x3_3724e6e5-154e-4b4f-bc96-12ed5d3b362a.jpg?v=1766114546"},{"product_id":"allen-bradley-1762-l24bwar-micrologix-1200-24-point-controller","title":"Allen-Bradley 1762-L24BWAR MicroLogix 1200 24 Point Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1762-L24BWAR\u003c\/strong\u003e is a 24-point programmable logic controller belonging to the \u003cstrong\u003eMicroLogix 1200\u003c\/strong\u003e product series. It serves as a compact and reliable processing module for localized machine-level industrial automation. Operating on a 120\/240V AC power supply, the unit delivers integrated input\/output processing via 14 digital 24V DC inputs—configured as 10 standard inputs and 4 fast high-speed inputs—combined with 10 digital relay outputs. This Series C revision features an integrated auxiliary Programming\/HMI port alongside its primary interface to allow concurrent terminal or peripheral messaging.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnified fixed controller configuration supporting a 24-point localized I\/O array.\u003c\/li\u003e\n\u003cli\u003eConfigured with 14 discrete 24V DC inputs, utilizing 4 fast points specialized for high-speed counter tasks.\u003c\/li\u003e\n\u003cli\u003eProvides 10 isolated mechanical relay outputs capable of multi-voltage load switching.\u003c\/li\u003e\n\u003cli\u003eEquipped with an additional specialized Programming\/HMI port to facilitate localized monitoring.\u003c\/li\u003e\n\u003cli\u003eSystem expansion ready, allowing up to four discrete 1762 I\/O expansion modules to fit customized applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocalized machine control and packaging machinery.\u003c\/li\u003e\n\u003cli\u003eMulti-axis material handling and conveyor automation.\u003c\/li\u003e\n\u003cli\u003eSCADA RTU nodes and distributed pumping control installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1762-L24BWAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Power Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 total: 10 Standard 24V DC, 4 Fast 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Speed Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20 kHz (on fast inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-state Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 30.0V DC (at 30 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-state Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x Programming\/HMI Port, Expansion Bus Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm (4.33 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm (3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 mm (3.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the device within a clean industrial enclosure, maintaining a required clearance of at least 50 mm (2 in.) on all sides to allow proper ventilation and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eAttach firmly to a standard symmetric DIN rail or use the integrated screw mounting holes for secure flat panel installation.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC input lines and low-voltage 24V DC I\/O lines through separate wiring conduits to limit local electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eConnect the frame ground terminal directly to a low-impedance master ground system before completing auxiliary I\/O terminations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53434514473323,"sku":"1762-L24BWAR","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1762-L24BWAR_1.jpg?v=1782716996"}],"url":"https:\/\/www.plcprotech.com\/vi\/collections\/allen-bradley-micrologix.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}