{"title":"Bently Nevada 3300 NSv Proximitor Sensor","description":"\u003cp\u003eThe Bently Nevada 3300 NSv Proximitor Sensor is the electronic heart of the NSv transducer system, engineered specifically for confined mounting scenarios. Its architecture is designed to drive \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-nsv-proximity-probes\"\u003e3300 NSv proximity probes\u003c\/a\u003e through specialized \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-nsv-extension-cable\"\u003eNSv extension cables\u003c\/a\u003e. Technical characteristics include a unique linear range optimized for smaller targets and the ability to operate effectively with narrow shaft diameters. Functionally, this sensor converts the impedance changes in the probe tip into a proportional voltage signal, specialized for detecting shaft vibration and position in tight spaces. It offers the same high reliability as the standard 3300 XL series but with electronic tuning that accounts for the smaller physical dimensions of the NSv probe, ensuring precision in air compressors and high-speed pumps.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330980-70-00-3300-xl-nsv-proximitor-sensor","title":"Cảm biến Bently Nevada 330980-70-00 3300 XL NSv Proximitor","description":"\u003ch3\u003eMô tả\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e330980-70-00\u003c\/strong\u003e là cảm biến tiếp cận hiệu suất cao được thiết kế như một thành phần cốt lõi của \u003cstrong\u003eHệ thống Bộ chuyển đổi Tiếp cận 3300 XL NSv\u003c\/strong\u003e. Cảm biến này được thiết kế đặc biệt cho các ứng dụng máy móc quan trọng với các hạn chế lắp đặt chặt chẽ, bao gồm máy nén khí ly tâm, máy nén lạnh và máy nén khí quy trình. \u003cstrong\u003e330980-70-00\u003c\/strong\u003e nhận tín hiệu đầu vào từ đầu dò tiếp cận không tiếp xúc 3300 RAM hoặc 3300 NSv và cáp nối dài liên quan, tạo ra đầu ra điện áp tương tự liên tục tỷ lệ thuận với khoảng cách khe hở giữa đầu dò và mục tiêu. Với Hệ số Tỷ lệ Trung bình (ASF) là 7,87 V\/mm (200 mV\/mil), nó cung cấp dữ liệu chính xác cho rung động hướng kính, vị trí trục, tốc độ đồng hồ tua và đo tín hiệu tham chiếu pha trên các máy có ổ trục màng chất lỏng. Vỏ cơ khí mỏng, tiết kiệm không gian của nó phù hợp với bố trí hệ thống giám sát đa kênh mật độ cao với khả năng bảo vệ RFI\/EMI hoàn chỉnh.\u003c\/p\u003e\n\u003ch3\u003eTính năng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTương thích hệ thống liền mạch, chấp nhận một đầu dò tiếp cận không tiếp xúc 3300 RAM hoặc 3300 NSv và cáp nối dài kèm theo.\u003c\/li\u003e\n\u003cli\u003eĐế lắp bảng mật độ cao được thiết kế để tích hợp chắc chắn vào các cấu hình giám sát tiêu chuẩn.\u003c\/li\u003e\n\u003cli\u003eKhả năng chống nhiễu RFI\/EMI tiên tiến đảm bảo tuân thủ đầy đủ dấu CE châu Âu và ngăn ngừa nhiễu tần số vô tuyến mà không cần vỏ che chắn chuyên dụng.\u003c\/li\u003e\n\u003cli\u003eDải đầu cuối SpringLoc không cần dụng cụ đặc biệt, cung cấp kết nối dây điện trường đáng tin cậy và kín khí.\u003c\/li\u003e\n\u003cli\u003eMạch nội bộ chắc chắn được bảo vệ chống phóng tĩnh điện (ESD) trong quá trình xử lý và vận hành.\u003c\/li\u003e\n\u003cli\u003eHiệu chuẩn mặc định tại nhà máy theo thép AISI 4140, duy trì độ chính xác cao và khả năng thay thế tuyến tính.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGiám sát rung động hướng kính và vị trí hướng kính trên máy nén ly tâm và máy nén khí quy trình.\u003c\/li\u003e\n\u003cli\u003eĐo vị trí trục (lực đẩy) trong các lắp đặt máy móc không gian chật hẹp.\u003c\/li\u003e\n\u003cli\u003eTạo tín hiệu tham chiếu pha cho đồng hồ tua, tốc độ bằng không và Keyphasor.\u003c\/li\u003e\n\u003cli\u003eNâng cấp và cải tiến cho các lắp đặt bộ chuyển đổi 3300 RAM, dòng 3000 và dòng 7000 190 cũ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông tin đặt hàng\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSố bộ phận\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMô tả\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330980-70-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCảm biến Proximitor 3300 XL NSv \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChiều dài tổng và tùy chọn lắp đặt: Hệ thống dài 7,0 mét (23,0 feet), lắp trên bảng điều khiển \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTùy chọn phê duyệt của cơ quan: Không yêu cầu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThông số kỹ thuật\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTham số\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eThông số kỹ thuật\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhà sản xuất\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDòng \/ Hệ thống\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHệ thống cảm biến gần 3300 XL NSv \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChấp nhận đầu vào\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMột đầu dò gần không tiếp xúc 3300 RAM hoặc 3300 NSv và cáp nối mở rộng \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYêu cầu nguồn điện\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17,5 Vdc đến -26 Vdc không có rào cản; -23 Vdc đến -26 Vdc có rào cản \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiêu thụ dòng\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTiêu thụ dòng tối đa 12 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐiện trở đầu ra\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhạm vi tuyến tính\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhạm vi tuyến tính 1,5 mm (60 mils) tổng; bắt đầu khoảng 0,25 mm (10 mils) từ mục tiêu \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHệ số tỷ lệ trung bình (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHệ số tỷ lệ tăng dần (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil) +12,5% \/ -20% trên phạm vi môi trường \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐáp ứng tần số\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 đến 10 kHz: +0, -3 dB điển hình với dây hiện trường lên đến 305 mét (1000 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKích thước dây hiện trường\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,2 đến 1,5 mm2 (16 đến 24 AWG) [0,25 đến 0,75 mm2 (18 đến 23 AWG) có đầu cos] \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChiều dài dây hiện trường\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTối đa 305 mét (1.000 feet) giữa cảm biến và bộ giám sát \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhiệt độ hoạt động\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 độ C đến +100 độ C (-62 độ F đến +212 độ F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNhiệt độ lưu trữ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 độ C đến +105 độ C (-62 độ F đến +221 độ F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐộ ẩm tương đối\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% ngưng tụ, không ngập nước khi đầu nối được bảo vệ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVật liệu vỏ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNhôm A380 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVật liệu đầu nối\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐầu nối ClickLoc bằng đồng thau mạ vàng \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrọng lượng\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrọng lượng điển hình 255 gram (9 ounce) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eKết nối\/Giao diện\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eKhối đầu cuối \/ Chân cắm\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eChức năng\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐầu vào nguồn cảm biến (-24 Vdc danh định) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eĐầu ra tín hiệu tương tự (Điện áp tỷ lệ với khe hở) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChung \/ Trở về mạch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐầu nối đồng trục\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKết nối đầu vào từ cáp mở rộng 3300 NSv (loại ClickLoc) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCấu hình lắp đặt:\u003c\/strong\u003e Mẫu cụ thể này (\u003cstrong\u003e-70\u003c\/strong\u003e) được cung cấp với cấu hình đế gắn bảng điều khiển. Cố định vỏ thiết bị phẳng lên bảng cấu trúc bằng các vít lắp được khuyến nghị.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKết nối dây hiện trường:\u003c\/strong\u003e Sử dụng dải đầu cuối SpringLoc không cần dụng cụ bằng cách chèn trực tiếp dây dẫn đã tước vỏ (16 đến 24 AWG) vào cơ chế kẹp để cố định dây hiện trường.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhù hợp cáp:\u003c\/strong\u003e Đảm bảo tổng chiều dài vật lý của đầu dò gần và cáp nối mở rộng được chọn chính xác bằng chiều dài điều chỉnh hệ thống 7,0 mét của cảm biến.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXả tĩnh điện (ESD):\u003c\/strong\u003e Áp dụng dây đeo đất ESD và các biện pháp phòng ngừa thích hợp khi chạm vào các đầu nối hoặc cổng đầu vào đồng trục trong quá trình lắp đặt để ngăn ngừa hư hại các linh kiện bên trong mạch.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666743751019,"sku":"330980-70-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-70-00-nsv-proximity-sensor-dgaaoqm1s0g_4fb30580-5cb3-4bae-9010-2ca327f5d798.jpg?v=1765446933"},{"product_id":"bently-nevada-330980-51-05-3300-xl-nsv-proximitor-sensor","title":"Cảm biến Bently Nevada 330980-51-05 3300 XL NSv Proximitor","description":"\u003ch3\u003eMô tả\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330980-51-05\u003c\/strong\u003e là \u003cstrong\u003ecảm biến Proximitor 3300 XL NSv\u003c\/strong\u003e không tiếp xúc được thiết kế như một thành phần tích hợp của \u003cstrong\u003eHệ thống cảm biến khoảng cách 3300 XL NSv\u003c\/strong\u003e. Hệ thống này được phát triển đặc biệt cho máy móc có giới hạn lắp đặt chặt chẽ hoặc kích thước mục tiêu hạn chế, như máy nén khí ly tâm, máy nén lạnh và máy nén khí quy trình. Nó vượt trội trong các ứng dụng mà giới hạn khoét lỗ, quan sát bên hoặc quan sát phía sau hạn chế việc sử dụng các biến thể cảm biến tiêu chuẩn 5 mm và 8 mm. \u003cstrong\u003e330980-51-05\u003c\/strong\u003e xử lý tín hiệu đầu vào để cung cấp giám sát chính xác rung động hướng kính, vị trí hướng kính, vị trí trục dọc, đồng hồ tốc độ và tín hiệu tham chiếu pha (Keyphasor) trên máy có ổ trục màng chất lỏng.\u003c\/p\u003e\n\u003cp\u003eĐược thiết kế với kích thước nhỏ gọn và mỏng, \u003cstrong\u003eCảm biến Proximitor\u003c\/strong\u003e này được cấu hình tại nhà máy cho cấu trúc gắn thanh ray DIN 35 mm mật độ cao nhằm giảm thiểu không gian vỏ cần thiết. Nó có Hệ số Tỷ lệ Tăng dần (ISF) là 7,87 V\/mm (200 mV\/mil) trên phạm vi tuyến tính 1,5 mm (60 mils). Được trang bị dải đầu cuối SpringLoc tích hợp, thiết bị hỗ trợ kết nối hiện trường chắc chắn và nhanh chóng mà không cần dụng cụ chèn chuyên dụng. Thêm vào đó, khả năng chống nhiễu RFI\/EMI tiên tiến giúp thiết bị đáp ứng yêu cầu CE của châu Âu mà không cần che chắn đặc biệt hoặc lắp đặt cách ly.\u003c\/p\u003e\n\u003ch3\u003eTính năng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTối ưu hóa hiệu suất đo không tiếp xúc cho không gian máy chật hẹp và đường kính trục nhỏ.\u003c\/li\u003e\n\u003cli\u003eHồ sơ cơ học mỏng cho phép lắp đặt hiệu quả mật độ cao trên thanh ray DIN tiêu chuẩn 35 mm.\u003c\/li\u003e\n\u003cli\u003eDải đầu cuối SpringLoc tích hợp cung cấp kết nối điện đáng tin cậy, chống rung mà không cần dụng cụ đặc biệt.\u003c\/li\u003e\n\u003cli\u003eKháng RFI\/EMI cao ngăn chặn các tín hiệu radio tần số cao xung quanh làm giảm độ chính xác đo của cảm biến.\u003c\/li\u003e\n\u003cli\u003eMạch bảo vệ bên trong bảo vệ các đường dẫn đầu cuối và đầu nối nhạy cảm khỏi hư hại do phóng tĩnh điện.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eỨng dụng\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMáy nén khí ly tâm\u003c\/li\u003e\n\u003cli\u003eMáy nén lạnh\u003c\/li\u003e\n\u003cli\u003eMáy nén khí quy trình\u003c\/li\u003e\n\u003cli\u003eTheo dõi rung động hướng kính và vị trí trục dọc trên trục đường kính nhỏ (dưới 51 mm)\u003c\/li\u003e\n\u003cli\u003eGiám sát tín hiệu tham chiếu pha (Keyphasor) và tốc độ không của đồng hồ tốc độ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThông tin đặt hàng\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eTùy chọn\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 14.5098%;\"\u003e\u003cstrong\u003eLựa chọn\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 53.2027%;\"\u003e\u003cstrong\u003eMô tả\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eMẫu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e330980\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003eCảm biến Proximitor 3300 XL NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eAA (Chiều dài tổng \u0026amp; Gắn kết)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e51\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003eChiều dài hệ thống 5,0 mét (16,4 feet), gắn DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.7534%;\"\u003e\u003cstrong\u003eBB (Phê duyệt cơ quan)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.5098%;\"\u003e05\u003c\/td\u003e\n\u003ctd style=\"width: 53.2027%;\"\u003eCSA, ATEX, IECEx Vùng 0\/1, Lớp cơ bản I, Vùng 0\/1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThông số kỹ thuật kỹ thuật\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDanh mục\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTham số\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eThông số kỹ thuật\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eĐiện\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCấu hình đầu vào cảm biến\u003c\/td\u003e\n\u003ctd\u003eChấp nhận một đầu dò tiếp cận không tiếp xúc 3300 RAM hoặc 3300 NSv và cáp nối dài\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYêu cầu điện áp đầu vào\u003c\/td\u003e\n\u003ctd\u003e-17,5 Vdc đến -26 Vdc (không có rào cản), dòng tối đa 12 mA; -23 Vdc đến -26 Vdc (có rào cản)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTrở kháng đầu ra\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eĐộ nhạy điện áp cung cấp\u003c\/td\u003e\n\u003ctd\u003eThay đổi điện áp đầu ra dưới 2 mV trên mỗi volt thay đổi điện áp đầu vào\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhạm vi tuyến tính\u003c\/td\u003e\n\u003ctd\u003e1,5 mm (60 mils); bắt đầu khoảng 0,25 mm (10 mils) từ bề mặt mục tiêu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHệ số tỷ lệ gia tăng (ISF)\u003c\/td\u003e\n\u003ctd\u003e7,87 V\/mm (200 mV\/mil) +12,5% \/ -20% trong phạm vi tuyến tính bao gồm khả năng thay thế\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSai lệch so với đường thẳng phù hợp nhất (DSL)\u003c\/td\u003e\n\u003ctd\u003eSai lệch dưới ±0,06 mm (±2,3 mils) trong phạm vi tuyến tính\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eĐáp ứng tần số\u003c\/td\u003e\n\u003ctd\u003e0 đến 10 kHz: +0, -3 dB điển hình với dây trường dài đến 305 mét (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCài đặt khe hở khuyến nghị\u003c\/td\u003e\n\u003ctd\u003e1,0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCơ khí\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVật liệu vỏ\u003c\/td\u003e\n\u003ctd\u003eNhôm A380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eKết thúc dây\u003c\/td\u003e\n\u003ctd\u003eDải đầu nối SpringLoc tích hợp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eKích thước (D x R x C)\u003c\/td\u003e\n\u003ctd\u003e8,13 cm x 6,12 cm x 6,35 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTrọng lượng tịnh (Thông thường)\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMôi trường\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNhiệt độ hoạt động\u003c\/td\u003e\n\u003ctd\u003e-52 độ C đến +100 độ C (-62 độ F đến +212 độ F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNhiệt độ lưu trữ\u003c\/td\u003e\n\u003ctd\u003e-52 độ C đến +105 độ C (-62 độ F đến +221 độ F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhạm vi độ ẩm tương đối\u003c\/td\u003e\n\u003ctd\u003e100% ngưng tụ, không ngâm nước khi các đầu nối được bảo vệ (Đã thử nghiệm theo IEC 68-2-3 nhiệt ẩm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHướng dẫn lắp đặt\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLắp đặt trên ray DIN:\u003c\/strong\u003e Gắn chắc chắn lên ray DIN tiêu chuẩn 35 mm bằng đế gắn tích hợp mật độ cao. Đảm bảo khoảng cách tối thiểu 3,05 mm để dễ dàng lắp và tháo ray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKết nối dây trường:\u003c\/strong\u003e Cắm dây trường đã bóc vỏ vào các đầu nối SpringLoc. Tiết diện dây hỗ trợ từ 0,2 đến 1,5 mm2 (16 đến 24 AWG), hoặc 0,25 đến 0,75 mm2 (18 đến 23 AWG) nếu sử dụng đầu cos dây. Khuyến nghị sử dụng cáp ba dây có che chắn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGiới hạn khoảng cách tối đa:\u003c\/strong\u003e Khoảng cách cáp tối đa cho phép giữa Cảm biến Proximitor và giá giám sát không được vượt quá 305 mét (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiếp đất và che chắn:\u003c\/strong\u003e Đảm bảo thân cảm biến được cách ly cơ học khỏi đất vỏ bằng các thành phần không dẫn điện phù hợp để ngăn nhiễu chế độ chung và vòng đất.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTuân thủ và Chứng nhận\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChỉ thị EMC:\u003c\/strong\u003e Tuân thủ Chỉ thị Cộng đồng Châu Âu 2014\/30\/EU, EN 61000-6-2 (Miễn dịch công nghiệp) và EN 61000-6-4 (Phát xạ công nghiệp).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Tuân thủ Chỉ thị Cộng đồng Châu Âu 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChứng nhận khu vực nguy hiểm:\u003c\/strong\u003e Được chứng nhận theo tiêu chuẩn CSA, ATEX và IECEx cho các lắp đặt an toàn nội tại Zone 0\/1, Div 1 theo mã tùy chọn 05.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666758693227,"sku":"330980-51-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-51-05-proximity-sensor-ldi15pzeysx_72df144a-4f50-41b4-8f77-e811785b6031.jpg?v=1765447085"},{"product_id":"bently-nevada-330980-50-00-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-00 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-50-00\u003c\/strong\u003e is a non-contacting proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is engineered for machines with tight installation requirements, such as centrifugal air compressors, refrigeration compressors, and process gas compressors, where counter bore, sideview, or rearview restrictions limit the use of standard transducer systems. The \u003cstrong\u003e330980-50-00\u003c\/strong\u003e functions by outputting an Average Scale Factor of 7.87 V\/mm (200 mV\/mil), which is ideal for small target applications such as measuring radial vibration on shafts smaller than 51 mm or axial position on flat targets smaller than 15 mm.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e features a thin design optimized for traditional panel mount configurations. It provides advanced RFI\/EMI immunity that prevents nearby high-frequency radio signals from adversely affecting the transducer system, enabling it to achieve European CE mark approvals without specialized mounting considerations. Additionally, the device is equipped with SpringLoc terminal strips that require no special installation tools, facilitating robust and fast field wiring connections.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for space-restricted industrial applications with a thin and compact panel-mount design.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated SpringLoc terminal strip to accelerate field installation and maximize wiring robustness without special tools.\u003c\/li\u003e\n\u003cli\u003eProvides high RFI\/EMI immunity to resist electromagnetic noise from nearby high-frequency radio devices.\u003c\/li\u003e\n\u003cli\u003eProtects internal transducer electronics against electrostatic discharge at the terminals and connector interfaces.\u003c\/li\u003e\n\u003cli\u003eCapable of driving direct replacements for legacy 3300 RAM and 3000-series or 7000-series 190 Transducer Systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small-diameter shafts \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small flat targets \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and Phase reference (Keyphasor) signal monitoring \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003eNSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal length and mounting option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metre (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency approval option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approximately 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eSpringLoc terminal strips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight (typical)\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Secure the device into the designated housing or junction box plate using the integrated panel-mount base orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect field wiring using 0.2 to 1.5 mm2 (16 to 24 AWG) conductors, or 0.25 to 0.75 mm2 (18 to 23 AWG) if using ferrules. A three-conductor shielded triad cable is recommended.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e Ensure the total distance between the Proximitor Sensor and the associated monitor does not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e While terminal and connector tracks include internal protection circuits, use an ESD wrist strap and standard grounding practices during handling and field terminal wire connections to avoid electrostatic discharge damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846511467,"sku":"330980-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-50-00-nsv-proximitor-sensor-mkqkniffh3n_2c8deaf5-adf3-4ef9-88be-ef6c2eabde61.jpg?v=1765448933"},{"product_id":"bently-nevada-330980-71-00-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-00 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-71-00\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. It is specifically engineered for use with centrifugal air compressors, refrigeration compressors, process gas compressors, and other machinery exhibiting tight installation requirements or small target areas. This includes measuring radial vibration or radial position on shafts smaller than 51 mm (2 inches) and axial position on flat targets smaller than 15 mm (0.6 inches).\u003c\/p\u003e\n\u003cp\u003eThe device features an enhanced side-view profile and small target characteristics that deliver a 1.5 mm (60 mils) linear range. Utilizing SpringLoc terminal strips, it allows robust field wiring connections without requiring specialized installation tools. Its compact mechanical profile supports high-density installations while providing immunity against RFI\/EMI high-frequency radio signals.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e optimizing performance for tight installation constraints.\u003c\/li\u003e\n\u003cli\u003eCompact design allows mounting in either high-density DIN-rail installations or traditional panel mount configurations.\u003c\/li\u003e\n\u003cli\u003eIntegrates SpringLoc terminal strips to enable fast, secure field wiring without specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eEnhanced RFI\/EMI immunity protects the transducer system from nearby high-frequency radio signal interference.\u003c\/li\u003e\n\u003cli\u003eDefault factory calibration to AISI 4140 steel, with alternative material calibrations available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors, refrigeration compressors, and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on fluid-filmed bearing machines with small shafts.\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small or restricted flat targets.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed measurements, and phase reference (Keyphasor signals).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330980-71-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length, DIN mount, Agency Approval: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption (-23 Vdc to -26 Vdc with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over the 1.5 mm linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) starting at approx. 0.25 mm (10 mils) from target (0.25 to 1.75 mm \/ 10 to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet) between Proximitor Sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Weight (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Designed for 35mm DIN rail mounting installations. Ensure a minimum additional clearance of 3.05 mm (0.120 inches) is available to remove the DIN rail smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use a three-conductor shielded triad cable between the sensor and the monitor up to a maximum length of 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge:\u003c\/strong\u003e Take reasonable engineering precautions to avoid electrostatic discharge during handling and electrical connection hookup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Ensure the proper mounting pads are utilized to isolate the sensor body from the housing ground environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0), SIL 3 (HFT = 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e 2019 Rules for Conditions of Classification (Part 1, 1-1-1\/7.7, 1-1-A3, 1-1-A4) and Part 1 Offshore Units and Structures (1-1-4\/9.7, 1-1-A2, 1-1-A3).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848969067,"sku":"330980-71-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-71-00-nsv-proximitor-sensor-ve42ucabr4j_6166de64-f722-486c-802a-f17976637fcc.jpg?v=1765449002"},{"product_id":"bently-nevada-330980-50-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eSystem \u0026amp; Engineering Context\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-50-05\u003c\/strong\u003e is a high-stability, active radio-frequency (RF) signal conditioning module designed as the core processing engine of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. The NSv (Narrow Side-view) sub-series is specifically deployed on fluid-filmed bearing assets where tight installation clearances, micro-diameter shafts (less than 51 mm \/ 2 in), or tight counterbores restrict the usage of standard 5mm and 8mm probes.\u003c\/p\u003e\n\u003cp\u003eThe primary electrical role of this Proximitor Sensor is to provide the high-frequency excitation carrier loop to a non-contacting 3300 NSv probe via a 75-ohm extension cable. It reads the raw modulation of the RF field caused by shaft eddy currents and converts these micro-gap fluctuations into a clean, linear, and continuous voltage output. This output features a native scale factor of \u003cstrong\u003e7.87 V\/mm (200 mV\/mil)\u003c\/strong\u003e, making it fully compatible with raw vibration input channels on 3500 series machinery protection racks or directly linkable to external PLC\/DCS analog tachometer and condition-monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Analysis \u0026amp; Suffix Matrix\u003c\/h3\u003e\n\u003cp\u003eThe specific option configuration code \u003cstrong\u003e330980-50-05\u003c\/strong\u003e defines a highly specialized build, providing integrated mechanical rails and hazardous area framework coverage:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (330980):\u003c\/strong\u003e 3300 XL Narrow Side-view (NSv) Proximitor Sensor hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Length (50):\u003c\/strong\u003e Calibrated exclusively for a \u003cstrong\u003e5.0-meter total electrical loop\u003c\/strong\u003e (e.g., combining a 0.5m probe with a 4.5m extension cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option (05):\u003c\/strong\u003e Integrated \u003cstrong\u003e35 mm DIN rail mounting framework\u003c\/strong\u003e. The module features structural ruggedized polymer feet designed to snap directly onto standard top-hat DIN tracks (EIA \/ IEC standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option (05):\u003c\/strong\u003e \u003cstrong\u003eMultiple Approvals Certification\u003c\/strong\u003e. This covers comprehensive international safety protocols including ATEX, IECEx, and North American (CSA\/FM) intrinsic safety and non-incendive markings for Class I, Zone 0\/1\/2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReal Physical Dimensions \u0026amp; Total Cabinet Mass\u003c\/h3\u003e\n\u003cp\u003eIn high-density marshalling cabinets, substituting fake \"box dimensions\" for actual product envelopes results in critical thermal crowding and enclosure latch failures. Per official OEM design rules, the physical geometry and spatial clearances for the \u003cstrong\u003e330980-50-05\u003c\/strong\u003e DIN rail unit are strictly defined as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Module Structural Mass:\u003c\/strong\u003e \u003cstrong\u003e255 grams (9.0 oz)\u003c\/strong\u003e nominal dry weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Height:\u003c\/strong\u003e \u003cstrong\u003e103.1 mm (4.06 in)\u003c\/strong\u003e absolute base-to-top execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Width:\u003c\/strong\u003e \u003cstrong\u003e81.3 mm (3.20 in)\u003c\/strong\u003e overall frame width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Footprint Depth:\u003c\/strong\u003e \u003cstrong\u003e61.2 mm (2.41 in)\u003c\/strong\u003e protrusion from the base plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe Critical Installation Clearance:\u003c\/strong\u003e \u003cstrong\u003e89.4 mm (3.52 in)\u003c\/strong\u003e. According to the engineering blueprints, when mounted to a standard 35 mm DIN rail, a minimum clearance depth of 89.4 mm from the backplate is required to safely engage, pivot, and remove the Proximitor assembly without bending adjacent structural wire ducts or pinching terminal connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical radial shaft vibration decoding on high-speed centrifugal refrigeration and air compressors.\u003c\/li\u003e\n\u003cli\u003eDual-direction axial thrust position drift capture inside confined turbo-expander gearboxes.\u003c\/li\u003e\n\u003cli\u003eMulti-point speed sensing and Keyphasor phase reference logging on narrow-target generator shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecise Engineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Model ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980-50-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signaling Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear -4 Vdc to -20 Vdc (Operational envelope bounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 to 1.25 mm (10 to 50 mils) starting from target face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 12 mA from negative voltage rail (-24 Vdc supply card required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Load Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 10 kohm recommended interface resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Connector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated miniature ClickLoc threaded interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-terminal strip, accepts wire sizes up to 1.5 mm squares (16-24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMarshalling Cabinet \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe 5.0-Meter Circuit Match Rule:\u003c\/strong\u003e This 330980-50-XX Proximitor \u003cstrong\u003emust\u003c\/strong\u003e utilize an extension cable and probe layout that sums to exactly 5.0 meters of physical core line. Connecting this unit to a 7.0m or 9.0m cable system throws off the internal oscillator circuit’s balance, causing severe scaling distortion and triggering false channel warnings on the control panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Group Thermal Spacing:\u003c\/strong\u003e While the 330980-50-05 operates efficiently up to +100 degC, when grouping more than ten Proximitors sequentially on a single DIN track within an unventilated junction box, maintain a minimum of 10 mm lateral spacing or install an active air baffle to avoid heat concentration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Polarity Tracking:\u003c\/strong\u003e The terminal strip requires a negative power supply input (typically -24 Vdc). Wiring a standard positive instrument loop (+24 Vdc) to the power terminals will completely disable the unit and risks causing permanent reverse-polarity damage to the active RF output buffer stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity and Isolation:\u003c\/strong\u003e The coax outer sheath ring connects directly to the internal terminal grid. Ensure the field instrumentation cable shield running from the Proximitor to the DCS is grounded at \u003ci\u003eone single point\u003c\/i\u003e (typically at the control room rack ground) to avoid creating massive 50\/60 Hz electromagnetic loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857161067,"sku":"330980-50-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-50-05-proximitor-sensor-no5pi4jikgo_188a2339-042a-4d3d-b637-d017f2b5bdd2.jpg?v=1765449211"},{"product_id":"bently-nevada-330980-71-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-71-CN\u003c\/strong\u003e is a high-performance eddy-current proximity pre-amplifier designed to operate as the core signal processing component within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This driver module is engineered to convert the raw high-frequency radio frequency (RF) signal captured by an embedded proximity probe into a continuous, linear analog voltage output. With a nominal Average Scale Factor (ASF) of 7.87 V\/mm (200 mV\/mil), it delivers precise shaft displacement and dynamic vibration data to host machinery protection monitors, making it an essential component for the structural monitoring of high-speed centrifugal air compressors, refrigeration compressors, and process gas machinery with tight installation envelopes.\u003c\/p\u003e\n\u003cp\u003eIn terms of retrofitting and system lifecycle maintenance, the \u003cstrong\u003e330980-71-CN\u003c\/strong\u003e provides direct mechanical and electrical backward compatibility, allowing it to seamlessly replace legacy 3300 RAM transducer systems as well as 3000-series or 7000-series 190 transducer frameworks without requiring a complete teardown of existing field-routed probes or extension cables. This specific model represents a 7.0-meter total loop calibration profile configured for high-density 35 mm DIN rail mounting and features a specialized country-specific suffix for localized regulatory compliance. Enclosed in a rugged A380 die-cast aluminum housing and equipped with proprietary tool-free SpringLoc terminal blocks, the sensor provides enhanced immunity to industrial radio frequency interference (RFI) and electromagnetic noise (EMI) across complex industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for small-target applications and restricted side-view envelopes, including narrow shafts down to 51 mm or flat surfaces down to 15 mm.\u003c\/li\u003e\n\u003cli\u003eDelivers a stable 1.5 mm (60 mils) linear measurement range starting approximately 0.25 mm from the connected probe tip face.\u003c\/li\u003e\n\u003cli\u003eFeatures integrated SpringLoc terminal strips that establish highly vibration-resistant electrical connections without the need for specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eHigh-density DIN rail mount design providing superior RFI\/EMI shielding to allow direct back-to-back installation inside crowded control cabinets.\u003c\/li\u003e\n\u003cli\u003eRugged A380 aluminum housing construction offering exceptional structural integrity and an extremely low thermal expansion coefficient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density panel installations on standard 35 mm DIN rails for radial shaft vibration tracking on high-speed industrial turbo-machinery.\u003c\/li\u003e\n\u003cli\u003ePrecision rotor axial thrust position offset and fluid-film bearing wear monitoring in compact process gas expanders.\u003c\/li\u003e\n\u003cli\u003eHigh-frequency phase reference tracking, tachometer speed measurements, and zero-speed sensor calibration via Keyphasor signal loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA: System Length \u0026amp; Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-71\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length, 35 mm DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBB: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCertified for regional regulatory compliance (China localized standard marks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 59.2827%;\"\u003e\u003cstrong\u003ePrecise Engineering Data\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e330980-71-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eEddy Current Proximity Pre-amplifier \/ Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e1.5 mm (60 mils) absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eRecommended Gap Voltage Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-9.0 Vdc nominal midpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eOutput Impedance Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e50 ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eSystem Length Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e7.0 meters (must match the sum of probe and extension cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eHigh-density 35 mm standard DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eEnclosure Material Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eA380 Die-cast Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eWiring Terminal Structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003eSpringLoc terminal strips; accepts 0.2 to 1.5 mm2 (16 to 24 AWG) wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e100% condensing, non-submersible when terminals are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eSystem Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.2954%;\"\u003e\u003cstrong\u003eNet Sensor Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.2827%;\"\u003e255 grams (9.0 oz) nominal standard dry mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal\/Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial ClickLoc Barrel Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts the gold-plated miniature coaxial plug from the 3300 NSv extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit ground reference link returning to the monitoring rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: OUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog negative DC voltage output signal proportional to the dynamic probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal: VT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply input terminal receiving negative supply voltage (-24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Loop Matching Rule:\u003c\/strong\u003e This Proximitor sensor is factory-calibrated for a total electrical loop length of exactly 7.0 meters. The combined physical lengths of the connected 3300 NSv probe and the 3300 NSv extension cable \u003cstrong\u003emust\u003c\/strong\u003e equal 7.0 meters (e.g., a 0.5-meter probe paired with a 6.5-meter extension cable) to prevent severe scale factor calibration errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting Securement:\u003c\/strong\u003e When snapping the module onto a standard 35 mm DIN rail, ensure that the plastic spring-loaded release clip underneath completely engages. For multi-channel installations, maintain a slight physical air gap between adjacent modules to facilitate natural convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Wire Gauges:\u003c\/strong\u003e SpringLoc terminal blocks accommodate solid or stranded copper conductors ranging from 0.2 to 1.5 mm2 (16 to 24 AWG). If crimped wire ferrules are deployed, limit the maximum cross-sectional area to 0.75 mm2 (18 AWG) to ensure correct structural latching inside the clamp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e Although the internal circuits are ruggedized against static voltage transients, field technicians must follow standard ESD precautions and ground themselves before managing coaxial terminations, wiring signal leads, or interacting with terminal blocks to avoid damaging sensitive input stages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, meeting EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions) standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e Conforms to European Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Provides an Environment-Friendly Use Period (EFUP) designation of 15 years, tested in accordance with SJ\/T 11364-2024.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegional Compliance (-CN):\u003c\/strong\u003e Meets designated localized criteria for hazardous area installations within Mainland China jurisdictions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858078571,"sku":"330980-71-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-71-cn-nsv-proximitor-sensor-sipbsk22c5a_69e61be9-6793-4474-86f9-5ca0ab1bf2d6.jpg?v=1765449236"},{"product_id":"bently-nevada-330980-70-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-70-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eThe Bently Nevada 330980-70-05 is a high-precision eddy current measurement device configured as a 3300 XL NSv Proximitor Sensor for critical machinery vibration monitoring. This specialized sensor converts the radio frequency (RF) signal generated by a proximity probe into a proportional voltage output, enabling precise tracking of static position and dynamic displacement. It is specifically designed to work with the 3300 NSv probe and extension cable in confined installations with tight counterbore, sideview, or rearview restrictions that limit standard proximity systems. The specific model configuration dictates a \u003cstrong\u003e7.0-meter system length\u003c\/strong\u003e matching options for panel mounting and carries no specific hazardous area agency approvals. Operating as a critical module within turbomachinery protection systems, it delivers stable performance for small shaft diameters and target surfaces down to 15 millimeters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmall Target Optimization:\u003c\/strong\u003e Specifically calibrated to provide linear, reliable metrics on shaft targets down to 51 millimeters for radial vibration or 15 millimeters for axial position tracking.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTight Space Compatibility:\u003c\/strong\u003e Engineering design replaces legacy 3300 RAM and 3000\/7000-series systems where sideview restrictions compromise standard 5mm and 8mm probes.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e7.0-Meter Tuning:\u003c\/strong\u003e Internally balanced and calibrated for exact matching with a total probe and extension cable length of 7.0 meters to maintain signal integrity without field modifications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePanel Mount Chassis:\u003c\/strong\u003e Rigid structural frame designed for straightforward installation within internal instrumentation enclaves and standard termination cabinets.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh Noise Rejection:\u003c\/strong\u003e Shielded electronics minimize RF interference and cross-talk across long-distance monitor room loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eRadial vibration and position tracking loops on centrifugal air compressors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eThrust displacement and axial position monitoring in industrial refrigeration compressors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eTachometer, zero-speed, and phase reference Keyphasor measurements on small-diameter process gas compressor shafts.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCondition monitoring systems for fluid-filmed bearing machines with tight physical enclosure limitations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eOption Prefix\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSelected Option Field\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTechnical Configuration Meaning\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e330980\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBase Model Part\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-70\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTotal System Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.0 meters (23.0 feet), panel mount hardware\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-05\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo approvals required\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-17.5 VDC to -26 VDC current loop; 12 mA maximum consumption\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eScale Factor (ASF)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.87 V\/mm (200 mV\/mil) nominal response\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eLinear Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 mm (60 mils) starting at roughly 0.25 mm (10 mils) from probe tip\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100% condensing, non-submerged, when connector parts are protected\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Impedance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50 Ohm terminal signal configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChassis Design\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eA380 aluminum panel-mount frame configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.34 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e115 mm x 95 mm x 75 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOUT\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProportional voltage output signal path (200 mV\/mil output loop)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSignal common return reference point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVTX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNegative DC excitation power input (-24 VDC nominal supply line)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCoaxial Jack\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSecure connection interface to the 3300 NSv extension cable link\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and entirely disconnect external loop power before beginning installation tasks. Running structural or wiring maintenance on active, energized proximity loops poses severe risks of transient loop faults, erratic diagnostic readouts, or accidental machinery shutdown command generation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eField engineers must strictly observe the following technical sequence during field cabinet deployment:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the hardware frame on the clean chassis backplane inside the enclosure and tighten the panel screws to achieve a firm structural ground loop path.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eVerify total line length compatibility. The overall combination of the 3300 NSv probe and extension cable must equal exactly 7.0 meters to ensure accurate scaling parameters.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the coaxial terminal fitting of the extension cable into the integrated sensor receptacle, taking precautions to prevent mechanical binding or over-torque.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eLand the VTX, COM, and OUT wires into their distinct screw terminals on the block connector, maintaining separation from noisy motor electrical pathways.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868433259,"sku":"330980-70-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-70-05-3300-nsv-proximity-sensor-k510l25av2w_6bbfe511-4603-4e4e-b382-7872a110f62b.jpg?v=1765449542"},{"product_id":"bently-nevada-330980-50-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-50-CN\u003c\/strong\u003e is a high-performance proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e is specifically optimized for industrial machinery with tight installation requirements, small targets, or where counterbore and side-view restrictions limit standard transducer systems. The \u003cstrong\u003e330980-50-CN\u003c\/strong\u003e model features a 5.0-meter system length option configuration specifically engineered for panel mounting, providing an average scale factor of 7.87 V\/mm (200 mV\/mil) over a 1.5 mm (60 mils) linear range. It plays a critical role in fluid-filmed bearing machinery by converting eddy current signals from a proximity probe into a proportional voltage output for continuous vibration, speed, and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides an Average Scale Factor of 7.87 V\/mm (200 mV\/mil) for precise proximity measurements.\u003c\/li\u003e\n\u003cli\u003eCompact and thin design allows high-density installation configurations.\u003c\/li\u003e\n\u003cli\u003eEquipped with SpringLoc terminal strips for fast, secure field wiring without specialized tools.\u003c\/li\u003e\n\u003cli\u003eEnhanced RFI\/EMI immunity prevents adjacent high-frequency radio signals from impacting system operation.\u003c\/li\u003e\n\u003cli\u003eIntegrated protection against electrostatic discharge on terminals and connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small shafts \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small flat targets \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and phase reference (Keyphasor) signaling \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 24.6108%;\"\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 75.0654%;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Total Length and Mounting Option\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e-50\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e5.0 meters (16.4 feet) system length, panel mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.6108%;\"\u003e-CN\u003c\/td\u003e\n\u003ctd style=\"width: 75.0654%;\"\u003eATEX\/IECEx international approvals with local Chinese NEPSI industrial safety and explosion-proof certifications, along with compliance with Chinese RoHS regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA max consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20% over linear range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 meters of field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Cable Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules] \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between Proximitor Sensor and monitor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e The device is configured for traditional panel mounting. Ensure secure fastening to prevent structural vibration from affecting performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use three-conductor shielded triad cable for connection to the monitor. Strip wires and connect via the tool-free SpringLoc terminal strips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD):\u003c\/strong\u003e Observe proper ESD precautions during handling and installation to protect internal electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Use connector protectors on probe-to-cable and cable-to-sensor connections to prevent fluid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU:\u003c\/strong\u003e EN 61000-6-2 (Industrial具Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive 2011\/65\/EU:\u003c\/strong\u003e Compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e EFUP designation of 15 years per SJ\/T 11364-2024.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0), SIL 3 (HFT = 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc \/ ec IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298002795,"sku":"330980-50-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-50-CN-ige1xxa20xh_4e6a7407-85eb-4c06-a815-93b5a56e8f57.jpg?v=1765520466"},{"product_id":"bently-nevada-330980-51-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-51-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-51-CN\u003c\/strong\u003e is a high-performance proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This eddy current sensor provides precise non-contacting vibration and position measurements on machinery with tight installation constraints or small target areas, such as centrifugal air compressors, refrigeration compressors, and process gas compressors. By operating with an Average Scale Factor of 7.87 V\/mm (200 mV\/mil), the \u003cstrong\u003e330980-51-CN\u003c\/strong\u003e delivers highly accurate radial vibration, radial position, axial position, tachometer, and phase reference (Keyphasor) signals from fluid-filmed bearing machines.\u003c\/p\u003e\n\u003cp\u003eEngineered with a compact and thin form factor, this \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e is specifically configured for high-density 35 mm DIN-rail mounting, allowing industrial operators to optimize enclosure space. The device boasts enhanced immunity to radio frequency interference (RFI) and electromagnetic interference (EMI), ensuring signal integrity without needing specialized mounting hardware or isolated enclosures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOffers 1.5 mm (60 mils) of linear range, optimizing side-view and small-target measurement capability.\u003c\/li\u003e\n\u003cli\u003eEquipped with integrated SpringLoc terminal strips that enable swift, reliable field wiring connections without requiring specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eProvides exceptional RFI\/EMI immunity to prevent high-frequency radio signals from degrading transducer performance.\u003c\/li\u003e\n\u003cli\u003eDesigned to directly replace legacy 3300 RAM Transducer Systems and 3000-series or 7000-series 190 Transducer Systems.\u003c\/li\u003e\n\u003cli\u003eEmploys internal protection circuits against electrostatic discharge on terminal and connector surfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eFluid-filmed bearing machinery with small shafts or reduced side-view spacing \u003c\/li\u003e\n\u003cli\u003eRadial vibration and axial (thrust) position monitoring \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and Keyphasor phase reference signal tracking \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 metre (16.4 feet) system length, DIN mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Approvals country specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers; 12 mA maximum consumption \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); begins at approx. 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDSL Deviation\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eSpringLoc terminal strips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e8.13 cm x 6.12 cm x 6.35 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Designed to fit securely onto standard 35 mm DIN rails via its specialized high-density integrated base mount. Ensure the rail is properly secured and grounded to the enclosure grid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Supports wire cross-sections from 0.2 to 1.5 mm2 (16 to 24 AWG), or 0.25 to 0.75 mm2 (18 to 23 AWG) when utilizing wire ferrules. A three-conductor shielded triad cable is recommended for connections between the sensor and the monitoring rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Distance:\u003c\/strong\u003e The maximum allowable cable distance between the Proximitor Sensor and the monitoring system is 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Utilize an ESD wrist strap and follow safety handling procedures during terminal wiring to shield internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU, EN 61000-6-2 (Immunity for Industrial Environments), and EN 61000-6-4 (Emissions for Industrial Environments).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified for use in safety-instrumented systems up to SIL 2 (with HFT = 0) and SIL 3 (with HFT = 1).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315959659,"sku":"330980-51-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-51-cn-t1vqrvgdjgl.jpg?v=1765519934"},{"product_id":"bently-nevada-330980-70-cn-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-70-CN 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-70-CN\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as an essential part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is optimized for use with centrifugal air compressors, refrigeration compressors, process gas compressors, and other rotating machinery with tight installation space or small target constraints. It is primarily applied on fluid-filmed bearing machines to measure radial vibration, radial position, axial position, phase reference (Keyphasor signals), and zero-speed tachometer parameters. The design excels in environments where sideview, rearview, or counterbore restrictions eliminate the use of standard 5 mm and 8 mm transducer variants.\u003c\/p\u003e\n\u003cp\u003eWith a compact mechanical footprint, this \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e provides a 1.5 mm (60 mils) linear range and is configured for a standard 7.0-meter system length with a traditional panel mount orientation. It includes integrated SpringLoc terminal strips that deliver robust, vibration-resistant field connections without requiring specialized compression tools. Additionally, advanced internal protection circuitry yields high RFI\/EMI immunity, allowing the device to fulfill European CE mark parameters without demanding dedicated shielded enclosures or isolated mounting brackets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimizes proximity tracking on rotating machinery featuring restricted access, tight target constraints, and small shaft profiles.\u003c\/li\u003e\n\u003cli\u003eFlat panel mount design base tabs facilitate direct secure installation against junction box walls or enclosure frames.\u003c\/li\u003e\n\u003cli\u003eBuilt-in SpringLoc terminal strips offer reliable field wiring termination that withstands continuous structural vibration.\u003c\/li\u003e\n\u003cli\u003eAdvanced RFI\/EMI internal suppression preserves signal tracking accuracy against high-frequency radio signal interference.\u003c\/li\u003e\n\u003cli\u003eStandardized calibration profile tailored for AISI 4140 steel target faces under nominal factory conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors\u003c\/li\u003e\n\u003cli\u003eProcess gas compressors\u003c\/li\u003e\n\u003cli\u003eRadial vibration and fluid-filmed bearing position tracking on small machinery shafts\u003c\/li\u003e\n\u003cli\u003eThrust (axial) position tracking on small flat surfaces\u003c\/li\u003e\n\u003cli\u003ePhase reference tracking and zero-speed tachometer inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e7.0 metres (22.9 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eApprovals country-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input Profile\u003c\/td\u003e\n\u003ctd\u003eAccepts input from one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Voltage Requirements\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum current consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal under standard conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); begins at approximately 0.25 mm (10 mils) from the target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils) over the linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Voltage Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated SpringLoc terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMounting Design\u003c\/td\u003e\n\u003ctd\u003ePanel mount base layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when terminal connection paths are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Mount the sensor flat against the intended enclosure plate or layout junction panel using the structural mounting tabs on the sensor base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Interface:\u003c\/strong\u003e Strip field triad cable lines to the recommended engineering length and insert directly into the SpringLoc terminal paths. Standard terminals accept wire sizes from 0.2 to 1.5 mm2 (16 to 24 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Distance Constraints:\u003c\/strong\u003e Ensure that the cumulative field wiring loop distance separating the Proximitor Sensor from the monitoring system rack does not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Precautions:\u003c\/strong\u003e Maintain body isolation from common mechanical grounds via proper installation accessories to shield the measurement circuit from potential ground loops and electrical background noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Compliant with European Community Directive 2014\/30\/EU via EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Fulfills country-specific safety codes designated under the CN option configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317041003,"sku":"330980-70-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-70-cn-c15gvnluj3p_40d25a62-89c1-4ddd-9fde-e333b4a3dfb1.jpg?v=1765521057"},{"product_id":"bently-nevada-330980-71-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for specialized eddy-current machinery protection systems. This proximity sensor is purposefully optimized for demanding industrial deployment areas featuring compact installation constraints, such as centrifugal air compressors, process gas machinery, and refrigeration compression skids. It operates as a critical signal conditioner, converting raw electromagnetic gaps into a linear voltage signal to track machine health parameters.\u003c\/p\u003e\n\u003cp\u003eThe specific variant \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is designated for a \u003cstrong\u003e7.0-meter (23.0 feet) total system loop length\u003c\/strong\u003e and is equipped with an integrated \u003cstrong\u003eDIN-rail mounting track pad\u003c\/strong\u003e. It includes \u003cstrong\u003eMultiple Agency Approvals\u003c\/strong\u003e for universal hazardous area safety installation compliance. Featuring robust RFI\/EMI shielding and specialized SpringLoc terminal blocks, this thin-profile aluminum sensor provides high-stability signal fidelity and effortless field wire terminations without the need for specialized routing tools.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for small-shaft targets under 51 mm (2 inches) and restricted side-view or counterbore clearances.\u003c\/li\u003e\n\u003cli\u003eConfigured for a 7.0-meter total system loop length balancing length requirements across compact infrastructure layouts.\u003c\/li\u003e\n\u003cli\u003eSnap-on 35mm DIN-rail mounting base plate ensuring reliable electrical isolation from structural enclosure grounds.\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals certified for universal deployment across global plant environments.\u003c\/li\u003e\n\u003cli\u003eToolless SpringLoc terminal strip arrangement enabling fast, high-integrity field wiring connectivity.\u003c\/li\u003e\n\u003cli\u003eAdvanced onboard RFI\/EMI filtering achieving European CE compliance without restrictive shielding barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy radial vibration tracking and relative shaft position metrics on small-diameter high-speed rotors.\u003c\/li\u003e\n\u003cli\u003eCritical axial thrust displacement monitoring on fluid-filmed bearings with restrictive counterbore paths.\u003c\/li\u003e\n\u003cli\u003ePrecision zero-speed tracking, tachometer loops, and Keyphasor phase reference logging on industrial compressor skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980-71-05 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated DIN-rail mount backing pad \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 = Multiple Approvals (North America, ATEX\/Europe, IECEx, Brazil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical when calibrated to AISI 4140 steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approx 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 NSv or 3300 RAM probe and cable loop \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (Unbarrier-assisted maximum consumption 12 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305m field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Target Terminal Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm squares (16 to 24 AWG) solid or stranded \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Structural Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 die-cast aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Component Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 grams (9 ounces) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible with protected ClickLoc connections \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Coaxial Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-loss gold-plated brass female thread port securing the incoming extension cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal Strip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-station toolless spring cage landing for Signal, Common, and Supply wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Pad Track Tabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStructural clip array mating the isolated casing onto standard 35mm DIN-rails \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Snap the Proximitor Sensor base pad securely onto standard 35mm DIN rail tracks. Ensure the underlying replacement mounting pad isolates the metal chassis frame from raw cabinet ground grids to eliminate loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched Loop Length Balance:\u003c\/strong\u003e Verify that the combined mechanical lengths of the attached 3300 NSv probe and extension cable sum to exactly 7.0 meters to maintain calibrated scale factors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wire Termination:\u003c\/strong\u003e Use recommended three-conductor shielded triad cable (16 to 24 AWG). Depress the SpringLoc cage clips to seat bare wire ends completely before releasing tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Weatherproofing:\u003c\/strong\u003e Install specialized male\/female connector protectors or apply a wrap of self-fusing silicone tape over the coaxial links to block process fluids and maintain 100% condensing humidity defenses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668334342507,"sku":"330980-71-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-71-05-w4t4nu5gz1z_6c5fa473-8266-4734-87b8-42bf5db3ac2d.jpg?v=1765521444"}],"url":"https:\/\/www.plcprotech.com\/vi\/collections\/bently-nevada-3300-nsv-proximitor-sensor.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}