{"title":"Transducers","description":"\u003cp\u003eTransducers are precision devices that convert mechanical or physical variables into standard electrical signals for monitoring and control. The architecture involves advanced sensing elements, such as piezoelectric or strain gauges, integrated with signal-conditioning electronics in robust housings. Technical characteristics include high linearity, wide frequency response, and standardized voltage or current outputs. Functionally, transducers measure parameters like pressure, vibration, or displacement from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/probes\"\u003eprobes\u003c\/a\u003e and transmit the data to \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/i-o-modules\"\u003eI\/O modules\u003c\/a\u003e. This conversion is fundamental for providing the controller with accurate real-time feedback on machine health and process performance, allowing for precise automated adjustments and machinery protection.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3500-40m-140734-01-proximitor-monitor","title":"Bently Nevada 3500\/40M 140734-01 Proximitor Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3500\/40M (Part Number: 140734-01) is a high-performance, four-channel machinery protection monitor module built for the 3500 Series Machinery Protection System. The unit accepts continuous analog inputs from various Bently Nevada proximity transducers, conditioning the signals to track critical shaft metrics including radial vibration, eccentricity, thrust position, REBAM, and differential expansion.\u003c\/p\u003e\n\u003cp\u003eThe processed parameters are continuously compared against user-programmable alarm setpoints to execute automated emergency machine trips. The 140734-01 configuration represents the primary internal termination hardware layout, which interfaces the system backplane directly to field sensors. This module provides machinery protection data to plant operators while outputting diagnostic variables to asset management networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Board Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140734-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Monitor Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Independent Channels per Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Target\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Proximity Transducers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Termination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgrammable Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust Position, Eccentricity, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Point Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Alert levels, 2 Danger levels per active channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Processing Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time continuous analog sampling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX, and Bypass Front-Panel LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.6 cm x 25.8 cm x 24.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial turbomachinery maintenance demands tracking precise module part numbers to ensure compatibility with existing rack backplanes and monitoring configurations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type Designation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Printed Wire Assembly (PWA) ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e140734-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Component Subtype:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor I\/O Module with Internal Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Engineering Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Pair Configuration Rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/40M processes incoming proximity signals using paired channel paths (Channels 1 \u0026amp; 2, and Channels 3 \u0026amp; 4). When assigning functional modes via the 3500 Rack Configuration Software, the programmed choices must follow paired configuration guidelines. For example, you can perform up to two distinct monitoring functions simultaneously across a single pair, provided the underlying transducer sample rates match. Mismatched sensor types on a shared channel pair will cause firmware validation errors during configuration uploads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Termination Field Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 140734-01 features internal terminations, field sensor extension cables connect directly to the screw terminals on the back of the module.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip individual wire insulation back exactly 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted, shielded three-wire cabling for each probe link (\u003cstrong\u003ePower, Signal, Com\u003c\/strong\u003e) to isolate the system from electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the outer cable shields to the dedicated instrumentation ground bus within the rack enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Replacement Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/40M module supports hot-swapping while the primary rack remains powered up. However, removing an active monitor module immediately trips the \"OK\" relay and drives dependent channels into an invalid state.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChange the rack's physical keylock switch from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"RUN\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnable the software channel\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebypass flags\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtract the faulty 140734-01 board to avoid triggering false emergency machine shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the functional difference between the 3500\/40M and older 3500\/40 monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"M\" designation denotes enhanced processing capabilities. The 3500\/40M features faster internal signal processing loops, expanded memory registers for transient data logging, and more efficient output of continuous static values to modern control networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which field transducers can be integrated with the 140734-01 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module is optimized for Bently Nevada 8 mm, 11 mm, and 25 mm Proximitor Transducer Systems. It handles standard 5-meter and 9-meter loop lengths, converting raw gap voltage values into calibrated vibration or position readouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the front-panel LEDs assist with diagnostic troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolid Green \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlashing Red \"OK\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal hardware fault or configuration mismatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlashing Amber \"TX\/RX\":\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActive communication across the rack's internal data bus lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515161451,"sku":"3500\/40M 140734-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-40m-140734-01-proximitor-monitor-fzuhngamh0b_6277bb18-daed-4044-bae8-f490e4d427b0.jpg?v=1765440072"},{"product_id":"bently-nevada-330180-90-cn-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-CN 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN \u003c\/strong\u003eis a high-grade eddy-current displacement transmitter engineered by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evibration monitoring platform. Functioning as the core electronic conditioning driver in a non-contacting transducer circuit, this module converts high-frequency radio frequency fluctuations into a linear voltage output proportional to target movement. Heavy-duty rotating machinery infrastructures—including thermal power generation plants, petrochemical refineries, and continuous mining mills—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track fluid-film bearing dynamic health. By providing direct backward compatibility for obsolete legacy instrumentation, this sensor monitors shaft vibration and thrust positions accurately. This allows engineering teams to detect structural misalignment early, prevent devastating machine trips, and eliminate unprogrammed production downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe mechanical mounting, total loop tuning, and country-specific safety certifications for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor are systematically categorized through its specific alphanumeric suffix options.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Baseline Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware platform for the high-stability 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-90 System Length Parameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes a total calibrated loop system length of 9.0 meters (29.5 feet) configuration optimized exclusively for flat surface panel mounting. The internal oscillator circuit matches the specific impedance profile of a combined 9.0-meter probe and extension cable without field calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN Special Approval Token:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates regional country-specific hazardous area certification compliance, satisfying specialized industrial safety standards for deployment across localized high-risk automated areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications \u0026amp; Structural Limits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Telemetry Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Transducer Measurement Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Block Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Die-Cast Aluminum Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Tuning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet) Shared Loop Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Mounting Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlat Surface Panel Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Output Scale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Linear Scaling Vector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Operational Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Potential Power Supply Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Equipment Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Maximum Structural Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Compatibility \u0026amp; Diagnostics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat legacy hardware components does the 330180-90-CN replace within active control racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330180-90-CN serves as the advanced direct technological upgrade for obsolete legacy components, fully replacing old \u003cstrong\u003e330100-90-02\u003c\/strong\u003e and 330100-90-05 models. It allows seamless drop-in modernization without requiring users to replace existing compatible field probes, preserving infrastructure investments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific Proximitor model be supplied with validated manufacturing trace documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because this industrial transducer is manufactured in the United States, an official Certificate of Origin (COO) can be integrated into the technical documentation package upon project request, satisfying quality management system tracing and international import parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field probe variations can be connected to the input terminals of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor contains an adaptive input stage that accommodates a variety of Bently Nevada non-contacting sensors. It operates reliably with traditional 3300-series 5 mm, standard 3300-series 8 mm, or advanced 3300 XL 8 mm proximity probes and matching extension cables arranged in a 9.0-meter total loop configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Isolation and Moisture Safeguards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen connecting the proximity probe to the extension cable, shield the coaxial junction completely using high-dielectric silicone sleeve insulation. If the coaxial metal shells touch the machine frame, they will establish secondary ground paths that cause signal distortion. Wrap the completed junction in self-vulcanizing tape to prevent moisture or oil ingress from destabilizing the RF sensor data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Gap Voltage Target Selection and Verification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSet the physical position of the probe tip by tracking the DC gap voltage at the Proximitor terminal points using a calibrated multimeter. Adjust the probe depth inside the machine case until the voltage reads exactly -10.0 VDC, which positions the target directly in the center of the sensor's linear scaling range. Tighten the probe locknut carefully to prevent any shifting during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Paths and Noise Isolation Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the power supply lines and signal output loops away from high-voltage motor conductors using twisted, shielded instrumentation cables. Connect the cable shield to the main ground at the machinery monitoring rack terminal block only, cutting the shield clean at the sensor end. This practice prevents ground loop currents from injecting noise into the vibration processing cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515521899,"sku":"330180-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-cn-proximitor-sensor-w254xy3equw_73962b30-817f-4e70-9998-c31a1f0328f9.jpg?v=1765440079"},{"product_id":"bently-nevada-330180-92-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-92-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a high-precision, eddy-current displacement conditioning device developed by Bently Nevada for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Health Monitoring series. Acting as the core signal processing module within a non-contacting proximity probe circuit, this hardware converts raw radio-frequency (RF) field variations into linear voltage metrics directly proportional to shaft position. Mission-critical industrial assets—including large-scale steam turbine generators in power plants, high-pressure centrifugal compressors in oil refineries, and heavy-duty grinding mills in mining processing sites—rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05 (330180-92-05)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto track dynamic fluid-film bearing clearance. By delivering stable, sub-micron vibration and thrust readings directly to a 3500 rack system, this sensor detects structural oil whip or shaft misalignment early. This eliminates unexpected catastrophic machine trips, protects high-cost rotating shafts, and reduces factory unprogrammed downtime.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe exact hardware configuration, total system loop calibration, and hazardous location approval profile of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensor can be systematically decoded through its alphanumeric suffix structure.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180 Product Root:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the fundamental hardware classification for the high-performance 3300 XL Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-92 System Length Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDictates a total calibrated loop system length of 9.0 meters (29.5 feet). This parameter ensures the internal oscillator matches the impedance of a 9.0-meter combined probe and extension cable kit without requiring local field recalibration. This option specifically specifies a panel-mount chassis with no specialized DIN-rail mounting hardware included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05 Multi-Agency Approval Option:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertifies that the module meets strict international hazardous area explosion-proof standards, carrying full, simultaneous CSA, ATEX, and IECEx safety certifications for installation in Zone 0, Zone 1, and Zone 2 explosive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Standards \u0026amp; Dimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMachinery Protection Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Sensor Engineering Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Identity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-92-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes Business Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 3300-series 5 mm, 3300 8 mm, and 3300 XL 8 mm Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Structural Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremium Grade A308 Cast Aluminum Shell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Scale Calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (Total shared probe and cable length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) Nominal Linear Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA to 12 mA Nominal Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC Negative Supply Input via Monitor Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.246 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C Extended Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +105 deg C Structural Storage Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Maintenance \u0026amp; Operational FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 9.0-meter Proximitor sensor operate with a standard 5.0-meter extension cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The internal oscillation matrix of the 330180-92-05 is specifically tuned to match the capacitive and inductive characteristics of a 9.0-meter system. Mixing this module with a 5.0-meter probe and cable kit shifts the resonant frequency, which alters the scale factor from the standard 7.87 V\/mm (200 mV\/mil) and results in incorrect vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific field benefits does the A308 cast aluminum enclosure material provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe premium A308 cast aluminum housing acts as a durable shield that blocks high-frequency electromagnetic interference (EMI) and radio-frequency noise from affecting the internal circuitry. It also provides excellent physical protection against mechanical impacts, atmospheric corrosion, and moisture ingress in harsh compressor deck environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does an electrical technician identify a probe short-circuit versus an open-circuit fault during runtime?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy measuring the DC gap voltage at the sensor terminal block, field technicians can quickly check system integrity. A reading of 0 VDC or a very low positive value indicates a short-circuit condition, typically caused by a crimped cable trace or a grounded terminal connection. Conversely, a reading that matches the full supply voltage (-24 VDC) indicates an open-circuit fault, pointing to a broken terminal line or a severed probe tip.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Insulation and Structural Moisture Guarding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the probe lead to the extension cable inside the machine bracket, the coaxial connection must be completely isolated from the machine frame using high-dielectric silicone sleeves. Moisture or dirt inside this connection can degrade the RF signal, causing immediate measurement drift. Wrap the completed junction in self-fusing vulcanizing tape to keep out moisture on open compressor decks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Alignment and Calibration Benchmarks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring installation, set the physical probe gap using a digital multimeter connected across the sensor's \"OUT\" and \"COM\" terminal terminals. Rotate the probe body until the DC voltage measures exactly -10.0 VDC, which corresponds to the precise mid-point center of the sensor's linear calibration range. Tighten the probe locknut to the recommended installation torque specification to prevent mechanical drift during high-vibration turbine operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Board Wiring Layout and Noise Isolation Protocols:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the -24 VDC power and signal output loops through high-integrity twisted, shielded instrumentation cables. Ground the cable shields at a single point only, typically at the 3500 monitor rack terminal block, and cut the field shield clean at the sensor end. This grounding technique prevents ground-loop current paths from introducing electrical noise into the vibration monitoring channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515620203,"sku":"330180-92-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-92-05-proximitor-sensor-2qdeihaxoud_6675da58-f3f4-4717-a992-7d62ce7a6bbd.jpg?v=1765440080"},{"product_id":"bently-nevada-176449-02-3500-42m-proximitor-seismic-monitor","title":"Bently Nevada 176449-02 3500\/42M Proximitor Seismic Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02 (3500\/42M)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance four-channel vibration monitor engineered for the Bently Nevada 3500 Machinery Protection System. Designed for critical assets in power generation, oil and gas, and heavy manufacturing, this module accepts inputs from proximity, velocity, and acceleration transducers. Its primary role is to provide continuous machinery protection by cross-referencing live vibration data against user-defined alarm setpoints. By identifying early warning signs of shaft misalignment, bearing wear, or unbalance, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eempowers maintenance teams to execute predictive interventions, effectively eliminating catastrophic machine failures and drastically reducing unscheduled facility downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/42M monitor leverages a dual-pair channel architecture, allowing for versatile monitoring strategies within a single rack slot.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannels are configured in pairs (1\/2 and 3\/4), supporting simultaneous functions. For instance, one pair can monitor Radial Vibration while the second pair tracks Thrust Position or Acceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Value Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module conditions raw transducer signals into actionable parameters such as Direct, Gap, 1X and 2X Vector, Smax, and Eccentricity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiltering Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures programmable single-pole filters (4 Hz to 4000 Hz) and constant Q notch filters for \"Not 1X\" and vector monitoring, ensuring high-fidelity signal conditioning even in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel coaxial connectors provide short-circuit protected buffered signals for each channel, allowing for direct connection to external frequency analyzers or data collectors without interrupting protection loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e176449-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.7 watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kOhm (Standard I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (Individual for each channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 600 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Hz to 4000 Hz (User-programmable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Service FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the front-panel LEDs signify for system health?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED indicates the internal diagnostics of the 3500\/42M are successful. The TX\/RX LED flashes to confirm active serial communication with the Rack Interface Module (RIM), while the Bypass LED illuminates when the monitor is in Bypass Mode, indicating that alarm logic is inhibited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3500\/42M monitor process different transducer types simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, because channels are programmed in pairs, you can monitor Proximitor signals on one pair and Seismic (Velocity\/Acceleration) signals on the other pair, provided they are within the supported signal range of -24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a recorder output is short-circuited?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor operation and protection logic are completely unaffected by short circuits on the 4-20 mA recorder outputs. The module features internal voltage compliance management to maintain signal integrity across its load range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Commissioning Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways terminate signal cable shields at the 3500 system I\/O module ground terminals. Never ground the shield at both ends, as this introduces ground loops that can corrupt the sensitive vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor proximity probe applications, verify the \"Gap\" static value during installation. Ensure the probe is gapped within the linear range of the transducer (typically -10 VDC for standard 8 mm probes) to prevent signal clipping and maintain accurate alarm thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the load resistance for the 4-20 mA recorder outputs does not exceed 600 Ohms. Exceeding this limit will result in signal saturation, causing inaccurate reporting to the DCS or PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen using the monitor in high-density rack configurations near the 65 Celsius limit, ensure proper cabinet ventilation. Sustained operation at peak temperatures can degrade the accuracy of the 4-20 mA resolution (from 0.25% at room temp to 0.7% at temperature limits).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516734315,"sku":"3500\/42M 176449-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-176449-02-proximitor-seismic-monitor-k32jvb2xqxe_b0d50d43-00a9-4728-9846-a30a23c88b20.jpg?v=1765440095"},{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Bently Nevada 289837-01 3500 ENCORE Proximitor\/Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Proximitor\/Seismic I\/O Module designed specifically for the Bently Nevada 3500 ENCORE Machinery Protection System. This module serves as the critical rear-panel interface for the 3500\/42E Vibration Monitor, facilitating the connection of up to four channels of proximity or seismic transducers. Deployed extensively in power generation, oil and gas, and mining sectors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables the monitoring of vital machinery parameters including radial vibration, thrust position, and eccentricity. By providing reliable signal conditioning and transmission to the main processor, this I\/O module ensures continuous machinery protection and high-fidelity data acquisition. It is an essential component for facilities transitioning from legacy 3300 systems to the ENCORE platform, allowing for modernized vibration monitoring without sacrificing the integrity of field wiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module is engineered to support the dual-architecture capabilities of the 3500 ENCORE series, ensuring maximum flexibility for vibration and position monitoring.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour-Channel Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilized in a standard 3500 ENCORE System Rack, the module supports four independent channels, programmed in pairs (Channels 1 \u0026amp; 2; Channels 3 \u0026amp; 4) to perform specific monitoring functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with a wide array of sensors, including proximity probes for fluid-film bearing measurements and seismic transducers (accelerometers or velocity sensors) for casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a 3500 ENCORE System configuration, the I\/O module interfaces with logic-programmable Relay Modules to drive machinery trip circuits based on user-defined Alert and Danger setpoints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConditioning Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel processes raw transducer signals into \"static values,\" providing operations personnel with real-time machinery health diagnostics for both steady-state and transient conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor\/Seismic I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (System Mode) \/ 2 Channels (Rack Upgrade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208.28 mm x 48.26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 289837-01 be used as a direct spare for 3300 series I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the 3500 ENCORE system is designed to upgrade 3300 monitors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically intended for use in the 3500 ENCORE System Rack. For \"Rack Upgrade\" configurations where the 3300 chassis remains, the system utilizes the pre-existing 3300 series I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this I\/O module support both radial vibration and thrust position simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since channels are programmed in pairs, you can configure Channels 1 and 2 for radial vibration while Channels 3 and 4 are configured for thrust position (or any other supported function) within the same 3500\/42E monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle signal faults such as a disconnected sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/42E monitor, interfacing through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e, continuously performs self-tests. If a transducer signal fails or field wiring is compromised, the monitor will flag a \"Not OK\" status, preventing false trips and alerting maintenance via the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting Proximitor or Seismic sensors to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals, ensure that cable shields are terminated only at the I\/O module ground. Do not ground shields at the transducer end to prevent ground loops, which can introduce noise and compromise vibration measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Torquing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the I\/O module is fully seated into the rear of the ENCORE rack and that the mounting screws are tightened to secure the module against the backplane. This is critical for maintaining signal integrity in high-vibration environments typical of compressor decks or turbine halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is rated for up to 95 percent non-condensing humidity, it should always be installed in a NEMA 4 or IP65 rated enclosure if located in areas with high moisture or corrosive chemicals. Ensure adequate airflow within the rack to maintain the operating temperature below the 65 deg C threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter replacing an I\/O module, always use the 3500 Rack Configuration Software to verify that the channel pairings and transducer types match the field-installed sensors. Perform a loop check to ensure that Alert and Danger setpoints are correctly driving the associated Relay Modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-140734-02-3500-42m-proximitor®-seismic-monitor","title":"Bently Nevada 140734-02 3500\/42M Proximitor®\/Seismic Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/42M\u003c\/strong\u003e, designated under spare component assembly \u003cstrong\u003e140734-02\u003c\/strong\u003e, is a four-channel machinery protection hardware instrument designed to process inputs from proximity and seismic transducers. The module acts as an analytical safety layer within the 3500 Machinery Protection System, conditioning analog wave inputs to calculate variables such as radial vibration, thrust position, eccentricity, or velocity, and executing comparisons against user-programmable alarm setpoints. Programmed in paired channel groups through the 3500 Rack Configuration Software, it drives automated alarms when configured safety limits are violated. The hardware supplies individual +4 to +20 mA current recorder loops for each channel to transmit real-time static values directly to distributed control networks and operational archiving servers without interrupting primary protective operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independent processing channels supporting multiple concurrent vibration and positional function types.\u003c\/li\u003e\n\u003cli\u003eFlexible transducer matching accommodating standard eddy current proximity probes, accelerometers, and velocity sensors.\u003c\/li\u003e\n\u003cli\u003ePairwise channel programming architectures permitting distinct mathematical operations across channel pairs 1-2 and 3-4.\u003c\/li\u003e\n\u003cli\u003eConfigurable Alert and Danger setpoint assignment supporting granular machine safety limits across all calculated static values.\u003c\/li\u003e\n\u003cli\u003eIndividual, front-panel coaxial buffered transducer connections engineered with short-circuit protection for structural diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial steam turbine rotor shaft radial vibration tracking and thrust position observation.\u003c\/li\u003e\n\u003cli\u003eLarge-scale centrifugal gas compressor casing seismic velocity monitoring and mechanical trip protection.\u003c\/li\u003e\n\u003cli\u003ePower generation gas turbine shaft absolute vibration and rotor eccentricity monitoring.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial fluid pump rolling element bearing health analysis using specialized REBAM logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/42-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor® Seismic Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eProx\/Seismic I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eProx\/Seismic I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eTMR Prox\/Seismic I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (4 x prox.\/accel. ch's) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (2 x prox.\/accl. + 2 x Velomitor® channels) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers (4 x Velomitor® channels) and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e09\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class 1, Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Proximitor®\/Seismic Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140734-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 4 proximity, velocity, or acceleration transducer signals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ for Proximitor and Acceleration inputs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBussed TMR Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kΩ effective impedance with 3 channels wired in parallel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Status Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOK LED, TX\/RX LED, Bypass LED \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 short-circuit protected coaxial connectors (1 per channel) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA DC individual loop per channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc range across load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Load Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bit Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3662 µA per bit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms or less \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThrust\/Diff. Expansion Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect filter: -3 dB at 1.2 Hz | Gap filter: -3 dB at 0.41 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatic Value Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.33% of full-scale typical, ±1% maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Setpoint Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin 0.13% of the desired value \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlert Alarm Delay Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDanger Alarm Delay Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 seconds or 1 to 60 seconds in 0.5 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Standard I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Barrier I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +65 Celsius (32 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% noncondensing relative humidity \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Non-barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 91.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Allocation Footprint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Coaxial Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected buffered output for dynamic signal diagnostics \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx\/Seismic I\/O Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear interface wire blocks for direct internal termination sensor hookups \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Termination Headers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated multi-pin headers interfacing to standalone terminal blocks \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated loop connection points for +4 to +20 mA proportional telemetry \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNoise Suppression: Ensure sensor shielding parameters are thoroughly maintained by tying instrumentation ground wires to the specified chassis ground points on the I\/O block to limit electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eAlignment Mapping: Confirm that the main card assembly \u003cstrong\u003e140734-02\u003c\/strong\u003e slides cleanly along the guide tracks of the front rack slot, seating firmly into the rear data backplane lines.\u003c\/li\u003e\n\u003cli\u003eTermination Rules: Never mix external termination blocks with I\/O modules explicitly designed and coded for internal termination applications.\u003c\/li\u003e\n\u003cli\u003eSpace Allotment: Maintain clear tracking lines on both the forward and rear margins of the chassis rack frame to promote unrestricted ambient airflow through the module housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Low-Voltage Directives: EN61010-01 safety requirements for industrial monitoring equipment.\u003c\/li\u003e\n\u003cli\u003eEMC Emissions Shielding: Certified under IEC\/EN 61000-6-4 and EN 55011 Class A standards.\u003c\/li\u003e\n\u003cli\u003eEMC Susceptibility Criteria: Meets EN 61000-4-2 Electrostatic Discharge (Criteria B) and EN 61000-4-3 Radiated Susceptibility (Criteria A).\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals: CSA\/NRTL\/C Class I, Division 2, Groups A, B, C, D (T4 rating at Ta = -30 Celsius to +65 Celsius).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component function as an absolute overspeed machinery shutdown mechanism?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this device is explicitly designed to handle dynamic proximitor and seismic acceleration\/velocity metrics rather than the high-frequency speed wheel edge triggers needed for deterministic overspeed protection loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the underlying distinction between the 3500\/42M designation and part number 140734-02?\u003c\/strong\u003e A: The 3500\/42M reflects the official overall functional system monitor series classification, whereas the code 140734-02 governs the exact ordering catalog number for the internal replacement main circuit board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Will an unexpected short circuit across the +4 to +20 mA recorder loop disrupt machinery protection?\u003c\/strong\u003e A: No, the analog current loop circuitry is internally isolated, meaning the processing logic, monitor functionality, and protective safety alarms continue operating normally if a field recorder loop shorts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to program channel 1 to calculate radial vibration while channel 2 evaluates thrust position?\u003c\/strong\u003e A: No, monitoring channels are configured software-wise in distinct functional pairs, meaning channels 1 and 2 must execute the same baseline behavioral function, while channels 3 and 4 can handle another.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the front panel indicators if the module experiences an internal processing error?\u003c\/strong\u003e A: The green OK LED will drop out of its constant illuminating status, signaling a hardware exception condition and initiating a safe system bypass state to avoid false over-limit trips.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517717355,"sku":"3500\/42M 140734-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42m-140734-02-proximitor-seismic-monitor-pwa-r0numhbecec_3ab792c9-f156-41de-b90f-53ed4538fa1b.jpg?v=1765440108"},{"product_id":"bently-nevada-330180-91-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-91-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configured for a 9.0 m system length, featuring a 35 mm DIN rail mounting plate, and supplied with no agency approvals. This sensor operates by conditioning and driving the signal from an eddy-current proximity probe, translating physical shaft displacement into a proportional DC voltage signal for monitoring system inputs.\u003c\/p\u003e\n\n\u003cp\u003eThis variant differs from the panel-mount configurations (such as Option 90) by utilizing a DIN-mount base that occupies a narrower 35.1 mm slot, allowing for high-density mounting in protective enclosures. While other configurations include hazardous area approvals (such as Option 05), this configuration (Option 00) is for general-purpose environments where agency listings are not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter electrical system length matched to 3300 XL 8 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounting base provides electrical isolation from the mounting surface.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a configuration without hazardous area agency approvals.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass or gold-plated beryllium copper connectors provide secure signal paths.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips facilitate field wiring without screw-clamping mechanisms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration measurement on steam and gas turbines, compressors, motors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial position monitoring of rotating shafts in industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting eddy-current displacement monitoring in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (No agency approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-91-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Not required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one non-contacting 3300 XL 8 mm Proximity Probe and Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Housing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA308 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 35.1 mm x 89.4 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.246 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input (-24 Vdc nominal)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eSystem Common (Return path)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProportional voltage output signal\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.2 to 1.5 mm2 (16 to 24 AWG) conductor sizes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module onto a standard 35 mm DIN rail. Ensure there is a minimum clearance of 3.05 mm above the device to allow easy removal from the DIN rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use a 3-conductor shielded triad cable for connecting the sensor output to the monitoring system. Keep the maximum cable run length below 305 meters (1,000 feet).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Strips:\u003c\/strong\u003e Utilize the SpringLoc terminal strips for fast, secure connections without screw-tightening. Stripped wire leads insert directly into the terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The integral mounting pad provides absolute electrical isolation from the DIN rail. No additional external isolator plates are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e Complies with European Union Directive 2014\/30\/EU standards including EN 61000-6-2 and EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestriction of Hazardous Substances (RoHS):\u003c\/strong\u003e Complies with Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified to SIL 2 (HFT = 0) and SIL 3 (HFT = 1) limits when used within a qualified safety instrumented system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval:\u003c\/strong\u003e None (Option 00 is specified for general-purpose, non-hazardous areas).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518897003,"sku":"330180-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-91-00-5-8-mm-proximitor-sensor-rcdw0doug3q_b421d6f1-53db-40f9-9769-1c1febddd9f7.jpg?v=1765440123"},{"product_id":"bently-nevada-330180-90-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (CSA, ATEX, IECEx approvals) specify this 3300 XL Proximitor Sensor configuration — \u003cstrong\u003e330180-90-05\u003c\/strong\u003e. This non-contacting sensor is a core conditioning module for Bently Nevada 3300 XL proximity transducer systems, which are used to measure radial shaft vibration, axial thrust position, and speed on rotating industrial machinery. The unit houses specialized oscillator and demodulator circuitry that generates a radio frequency signal, drives the connected eddy-current probe, and conditions the returning signal into a continuous analog voltage proportional to the dynamic gap distance.\u003c\/p\u003e\n\n\u003cp\u003eThis panel-mount variant features a standardized 4-hole mounting plate that shares an identical footprint with older Proximitor designs, simplifying legacy upgrades. The aluminum mounting base provides built-in electrical isolation, removing the requirement for separate isolator plates. Calibrated for 9.0-meter systems, the 330180-90-05 requires precise matching with a 3300 XL 8 mm proximity probe and extension cable that sum to a total physical length of exactly 9.0 meters. Option 05 compliance adds certified protection for hazardous locations, enabling safe deployment under global intrinsic safety and non-sparking\/non-incendive standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 90 configuration specifies a 9.0-meter system length calibration matched for 4-hole panel mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval delivers certified safety for hazardous locations under CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003eStandardized panel-mount footprint provides backwards compatibility with legacy Bently Nevada Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated electrical isolation on the mounting base eliminates the need for separate isolator hardware.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal block connectors provide secure field wiring connections without requiring special installation tools.\u003c\/li\u003e\n  \u003cli\u003eAdvanced RF\/EMI immunity satisfies European CE standards without requiring specialized shielded conduit or metallic enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and dynamic positioning measurements on high-speed turbines, compressors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and shaft eccentricity monitoring in power generation and petrochemical applications.\u003c\/li\u003e\n  \u003cli\u003eContinuous speed and tachometer input conditioning on industrial motors, generators, and fans.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring loops connected to Bently Nevada 3500 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-90-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, panel mount, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \u0026amp; Non-Incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (nominal -24 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog negative voltage (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6.5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) of 3-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0.246 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon reference \/ system ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage output signal (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the Proximitor sensor on a clean, flat surface using the integrated panel-mount base; the mounting base provides integral electrical isolation directly.\u003c\/li\u003e\n  \u003cli\u003eUse tinned 3-conductor shielded triad field wiring cable with wire sizes ranging from 0.2 mm2 to 1.5 mm2 (16 AWG to 24 AWG).\u003c\/li\u003e\n  \u003cli\u003eInsert wires directly into the SpringLoc terminal strip; no special insertion or clamping tools are required.\u003c\/li\u003e\n  \u003cli\u003eLimit total field wiring between the Proximitor sensor and the monitoring system to a maximum of 305 meters (1000 feet) to prevent high-frequency signal roll-off.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe and extension cables maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing.\u003c\/li\u003e\n  \u003cli\u003eFor hazardous locations, follow the certified wiring diagrams for intrinsically safe or non-incendive\/non-sparking requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e CE mark, RoHS Directive 2011\/65\/EU, China RoHS compliance (EFUP 15 years)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (Hardware Fault Tolerance HFT = 0), SIL 3 capable in redundant (HFT = 1) systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx certifications for intrinsically safe (ia) and non-incendive\/non-sparking (nA, ec) installations in Class I, Division 1\/2 and Zone 0\/2 hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519060843,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne_ce9ec8c7-1922-48ed-8e3a-ab4d790e2b9b.jpg?v=1765440127"},{"product_id":"bently-nevada-330180-51-00-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-51-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e configuration featuring a 5.0-meter system length compatibility and an integrated DIN-rail mounting base. This specific variant is specified with the 00 option code, indicating that it does not carry hazardous area agency approvals. The device houses the high-frequency oscillator and demodulator circuitry necessary to condition raw displacement data from a compatible 3300 XL 8 mm proximity probe and extension cable. It converts the physical gap between the probe tip and the target material into a continuous, linear analog voltage output proportional to shaft movement.\u003c\/p\u003e\n\u003cp\u003eBy pairing the sensor with a 5.0-meter total system length probe and extension cable, the measurement system maintains its linear calibration across a full 2.0 mm (80 mils) dynamic range. The integrated mounting base of this variant provides built-in electrical isolation, preventing ground loops and eliminating the need for separate isolator plates. The spring-loaded terminal strips provide secure field-wiring connections without requiring manual screw-type clamping.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 51 specifies compatibility with a 5.0-meter total system length and incorporates a 35 mm DIN-rail mount.\u003c\/li\u003e\n\u003cli\u003eOption 00 designates a standard build where special hazardous area certifications are not required.\u003c\/li\u003e\n\u003cli\u003eIntegrated SpringLoc terminal strips facilitate field-wiring installations without specialized tooling.\u003c\/li\u003e\n\u003cli\u003eIsolating mounting base prevents electromagnetic interference and ground-loop noise.\u003c\/li\u003e\n\u003cli\u003eBroad compatibility with standard 3300 XL 8 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor is used for machinery vibration, position, and shaft keyphasor measurements in standard industrial environments. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating process compressors\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pumps and gearboxes\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generator shaft bearings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor, 5.0 meters, DIN-rail mount, standard approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Total Length \u0026amp; Mounting Option\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) system length, DIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd\u003e330180-51-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail mount (Option 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capability\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300-series 5 mm or 3300 XL 8 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc; 12 mA maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Strip Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e89.4 mm x 81.3 mm x 61.0 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Label\u003c\/th\u003e\n\u003cth\u003eConnection Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog displacement signal output to monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem common \/ signal ground reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting base is locked onto a standard 35 mm DIN rail. Provide a minimum of 3.05 mm (0.120 inches) of vertical clearance above the housing to facilitate standard removal from the rail. Use three-conductor shielded triad cables for field wiring to connect terminals to the monitor. Keep field wiring within the maximum distance limit of 305 meters (1000 feet) to prevent output signal attenuation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Standard\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eComplies with European electromagnetic compatibility (EMC) standards without special shielded conduit or housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519781739,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth_23365f6d-1973-456e-ab2a-a90ed88b27f2.jpg?v=1765440141"},{"product_id":"bently-nevada-330180-085-03-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-085-03-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 085 (8.5 meters length), Option 03 (armored cable with connector protector), and Option 05 (CSA\/ATEX\/IECEx approvals) specify this 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e. This sensor module functions as a signal conditioner, driving the eddy-current proximity probe and translating the high-frequency transducer signal into a proportional displacement voltage. The analog voltage output represents the exact gap change between the probe tip and the observed shaft target area, transmitting directly into machinery protection monitors.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330180-085-03-05\u003c\/strong\u003e configuration is specifically calibrated for an 8.5 m total electrical system length (Option 085) and supports armored extension cabling assemblies paired with integrated fluorosilicone connector protectors (Option 03). Designed for installation in environments demanding rigorous intrinsic safety and non-sparking certifications, it includes comprehensive international approvals (Option 05) such as ATEX, IECEx, and CSA. The module incorporates electrical isolation in its base, removing the necessity of separate insulator plates and facilitating direct DIN rail or panel mounting.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.5 Meter Calibrated Length (Option 085):\u003c\/strong\u003e Generates matching impedance parameters calibrated to an 8.5 m proximity probe and cable configuration, preventing impedance mismatch errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Armor Integration (Option 03):\u003c\/strong\u003e Formulated to seamlessly match armored extension cables with integrated connector protectors to shield delicate connections from fluids and particulates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals (Option 05):\u003c\/strong\u003e Holds CSA, ATEX, and IECEx approvals for safe utilization in hazardous industrial locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Noise Immunity:\u003c\/strong\u003e Suppresses electrical noise from surrounding radios and variable frequency drives, complying with European CE requirements without requiring specialized metallic conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpringLoc Terminals:\u003c\/strong\u003e Uses spring-clamp connections that eliminate screws and prevent the connection degradation typically caused by machine vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and dynamic profiling on steam and gas turbines\u003c\/li\u003e\n\u003cli\u003eAxial position and thrust offset measurement on centrifugal compressor shafts\u003c\/li\u003e\n\u003cli\u003eRotor casing expansion and eccentricity monitoring in power generation installations\u003c\/li\u003e\n\u003cli\u003eBearing clearance and structural vibration tracking on high-power industrial motors and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, armored compatibility\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Calibrated Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e085\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet) system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Cabling and Protection Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eArmored cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-085-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibrated Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog proportional voltage (typically -10 VDC to -24 VDC range or 7.87 V\/mm [200 mV\/mil])\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRequired Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-24 VDC nominal supply (typically -18 VDC to -26 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strips (accepts up to 1.5 mm2 \/ 16 AWG wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount or 35 mm DIN rail compatible configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81 mm x 61 mm x 51 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the industrial terminal block is wired with shielded, twisted-pair cabling to shield the dynamic analog displacement signal from electrical noise.\u003c\/li\u003e\n\u003cli\u003eSecurely clamp the housing onto a standard 35 mm DIN rail or bolt directly to a panel. The integrated base isolation eliminates the need for separate non-conductive isolator plates.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in any connected probe or extension cabling, maintaining a bend radius above 25.4 mm (1.0 inch) to prevent physical cable damage or signal degradation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring by inserting a flat-blade screwdriver to release the spring-clamp inside the terminal, sliding in the stripped wire, and releasing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Approved for hazardous zone applications as intrinsically safe (Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc) or non-sparking (Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for Class I, Division 1, Groups A, B, C, and D hazardous environments when paired with intrinsically safe barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with standard European RFI\/EMI directives without requiring high-cost metallic conduit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525417835,"sku":"330180-085-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-085-03-05-proximity-probe-housing-assemblies-vp0dr22uf4n_f1685e23-303f-46ea-b271-e47a4108d19f.jpg?v=1765440264"},{"product_id":"bently-nevada-330881-28-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-85-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-04-85-03-02\u003c\/strong\u003e: PROXPAC XL metric proximity transducer assembly, featuring a 3300 XL 8 mm probe with multiple approvals (Option 28), a 40 mm standoff adapter (Option 04), an 85 mm probe penetration length (Option 85), one M20 cable fitting and two plugs (Option 03), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThe PROXPAC XL combines a proximity probe and a 3300 XL Proximitor sensor into a single integrated assembly, eliminating the need for separate extension cables or remote Proximitor housings. The housing body is manufactured from glass-reinforced, conductive-fiber-filled polyphenylene sulfide (PPS) thermoplastic, which offers Type 4X and IP66 protection against harsh industrial environments. Field wiring connects directly to terminal blocks inside the housing, simplifying installation and maintenance on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3300 XL 8 mm proximity probe with multiple hazardous area approvals (Option 28).\u003c\/li\u003e\n  \u003cli\u003e40 mm standoff adapter length (Option 04) for offset mechanical mounting.\u003c\/li\u003e\n  \u003cli\u003e85 mm probe penetration depth (Option 85) to reach internal target areas.\u003c\/li\u003e\n  \u003cli\u003eSupplied kit includes one M20 conduit fitting and two plugs (Option 03).\u003c\/li\u003e\n  \u003cli\u003e3\/4-14 NPT mounting thread (Option 02) designed for use with standoff adapters.\u003c\/li\u003e\n  \u003cli\u003eSelf-contained system eliminates the need for separate probe-to-Proximitor extension cabling.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing rated for IP66 and Type 4X environments.\u003c\/li\u003e\n  \u003cli\u003eField wiring terminal block inside the housing allows direct connection to the monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial shaft position and radial shaft vibration monitoring on critical rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting displacement measurement on steam turbines, gas turbines, compressors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery protection requiring explosion-proof or intrinsically safe sensor installation.\u003c\/li\u003e\n  \u003cli\u003eSevere-environment machinery monitoring where moisture, chemical exposure, or electrostatic discharge is present.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm Standoff Adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85\u003c\/td\u003e\n      \u003ctd\u003e85 mm Probe Penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs (supplied as a kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-85-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Series\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from approximately 0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc to -17 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Power Requirement\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e76.2 mm (3.0 in) minimum recommended, 50.8 mm (2.0 in) absolute minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n      \u003ctd\u003e1-metre, 75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connector\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Environmental Rating\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (operating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing \u0026amp; Sensor Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (operating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrounding: The grounding liner inside the housing provides a path to discharge static charges. Ensure the housing is properly grounded through the mounting structure or dedicated earth connection.\u003c\/li\u003e\n  \u003cli\u003eSealing: Use the neoprene O-ring provided between the sleeve and the housing. Apply appropriate thread sealant on the mounting threads to prevent moisture ingress.\u003c\/li\u003e\n  \u003cli\u003eConduit Connections: Route field wiring through the M20 fitting provided. Seal unused conduit entries with the supplied blanking plugs to maintain the IP66 environmental rating.\u003c\/li\u003e\n  \u003cli\u003eProximity Gap: Set the nominal gap between the probe tip and the shaft target at 1.27 mm (50 mils) to achieve centered operation in the 2.0 mm linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical Classification: Complies with the European CE mark\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Protection: Housing IP66 rating (verified by BASEEFA report)\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals: Multiple Approvals (Option 28) covering North American (CSA), European (ATEX), and International (IECEx) standards for Zone 0, Zone 1, Zone 2, Class I Division 1, and Class I Division 2 hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525647211,"sku":"330881-28-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-85-03-02-proximity-transducer-wgeeb2buii4_06b4432f-feb8-41e9-bc3c-350808d827ff.jpg?v=1765440269"},{"product_id":"bently-nevada-330881-28-04-145-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-145-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 04 (40 mm standoff adapter) define the metric configuration of this specialized PROXPAC XL Proximity Transducer — \u003cstrong\u003e330881-28-04-145-03-02\u003c\/strong\u003e. This integrated assembly features a 145 mm probe penetration length (Option 145) protected by a durable sleeve, a mounting configuration with a 3\/4-14 NPT thread (Option 02), and a fittings kit with one M20 conduit fitting and two plugs (Option 03).\u003c\/p\u003e\n\u003cp\u003eBy combining a high-accuracy 3300 XL 8 mm proximity probe and an integrated 3300 XL Proximitor sensor within a single, self-contained Polyphenylene Sulfide (PPS) housing, this design eliminates the need for separate extension cables and intermediate junction boxes. This metric setup simplifies installation and provides robust mechanical and environmental shielding for critical rotating machinery monitoring, making it highly effective for harsh industrial conditions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28 probe integration combines a 3300 XL 8 mm proximity probe with multiple approvals directly within the transducer housing.\u003c\/li\u003e\n\u003cli\u003eOption 04 standoff adapter provides a 40 mm standoff dimension for precise offset positioning during installation.\u003c\/li\u003e\n\u003cli\u003eOption 145 penetration designates a 145 mm sleeve depth to reach internal measurement targets effectively.\u003c\/li\u003e\n\u003cli\u003eOption 03 fitting package supplies one M20 conduit fitting and two plugs to simplify cable entry seal execution.\u003c\/li\u003e\n\u003cli\u003eOption 02 mounting thread specifies a 3\/4-14 NPT connection, meeting the mechanical requirements for standoff adapter support.\u003c\/li\u003e\n\u003cli\u003eThermoplastic PPS housing features a glass- and conductive-fiber reinforced design that provides Type 4X and IP66 environmental protection while dissipating electrostatic charges.\u003c\/li\u003e\n\u003cli\u003eIntegrated Proximitor sensor layout eliminates the field-wiring requirement for intermediate extension cables and separate transmitter enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position measurements on steam turbines, gas turbines, and large industrial compressors.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and displacement monitoring on high-speed rotating machinery in hazardous areas requiring multiple regional certifications.\u003c\/li\u003e\n\u003cli\u003eSevere-duty petrochemical, power generation, and water treatment installations where direct-exposure and chemical resistance are critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-145-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e145 mm probe penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-145-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegral Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-meter cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLid Label Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without safety barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.2 mm (3.0 in) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Practices:\u003c\/strong\u003e The PROXPAC XL housing must be properly grounded using the built-in grounding liner and retaining plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Prevention:\u003c\/strong\u003e Ensure that all conduit paths are completely sealed to prevent moisture from migrating through the conduit into the plastic housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Limits:\u003c\/strong\u003e Do not expose the probe tip to temperatures below -34 degC (-29 degF) to prevent premature failure of the internal pressure seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSleeve Support:\u003c\/strong\u003e If the combined standoff adapter (B) and penetration (C) lengths exceed 305 mm (12.0 in), implement additional external sleeve support near the probe to increase assembly stiffness and eliminate resonant vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with applicable European Union directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e Housing rated to IP66 (verified by BASEEFA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (CNRTLUS):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D; Class I, Zone 2: AEx\/Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (ATEX\/IECEx):\u003c\/strong\u003e II 1 G, Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc. II 3 G, Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527285611,"sku":"330881-28-04-145-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-145-03-02-proxpac-xl-proximity-transducer-p5pfxa0yjvs_921e9da5-5db0-492f-8cf9-8667e4385c76.jpg?v=1765440296"},{"product_id":"bently-nevada-330881-28-04-150-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-150-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with multiple approvals) and Option 150 (150 mm probe penetration sleeve) specify this unique PROXPAC XL configuration — \u003cstrong\u003e330881-28-04-150-06-02\u003c\/strong\u003e. This integrated transducer assembly features a 40 mm standoff adapter and NPT fittings with a stainless steel reducer to deliver a self-contained monitoring system that eliminates external extension cables. By mounting the 3300 XL Proximitor sensor directly in the housing cover, field wiring connects straight from the machinery monitors to the PROXPAC XL assembly, streamlining overall physical complexity.\u003c\/p\u003e\n\n\u003cp\u003eUnlike basic options lacking mechanical standoff, this metric variant uses a 3\/4-14 NPT mounting thread (Option 02) which is mechanically required to support the integrated 40 mm standoff adapter (Option 04). The body is molded from advanced, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers to strengthen the outer assembly and protect the interior against hostile chemical and electrostatic environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28 integration of a 3300 XL 8 mm proximity probe with multiple hazard approvals.\u003c\/li\u003e\n\u003cli\u003eOption 04 provides a 40 mm metric standoff adapter to ease machinery casing integration.\u003c\/li\u003e\n\u003cli\u003eOption 150 sleeve offers a 150 mm probe penetration length for exact gapping.\u003c\/li\u003e\n\u003cli\u003eOption 06 includes one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 provides 3\/4-14 NPT mounting thread required for standoff structural stability.\u003c\/li\u003e\n\u003cli\u003eAdvanced glass-reinforced polyphenylene sulfide (PPS) thermoplastic housing prevents electrostatic buildup.\u003c\/li\u003e\n\u003cli\u003eFully self-contained design removes the requirement for separate Proximitor housings and extension cables.\u003c\/li\u003e\n\u003cli\u003eNEMA Type 4X and IP66 environmental sealing handles demanding chemical and marine applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial position and shaft vibration monitoring in harsh industrial machinery setups.\u003c\/li\u003e\n\u003cli\u003eLocations with severe ambient environments where separate Proximitor protection is impractical.\u003c\/li\u003e\n\u003cli\u003eDirect-on-machine mounting where field wiring must run directly to monitoring racks.\u003c\/li\u003e\n\u003cli\u003ePetrochemical, power generation, and gas turbine installations requiring certified intrinsically safe hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Option\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-150-06-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e150 mm probe penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT thread (required if ordering Standoff Adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-04-150-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe with 1-metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Compatibility\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG), 3-conductor shielded triax recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), starting approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Deviation (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material and Retaining Chain\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve and Retaining Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid Label Material\u003c\/td\u003e\n\u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe Housing and Proximitor)\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sealing\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66 (verified by BASEEFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface Element\u003c\/th\u003e\n\u003cth\u003eDetails \/ Support\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect connection inside housing cover; supports up to 1.5 mm2 (16 AWG) field wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 metres (1,000 feet) between transducer and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Cable Connections\u003c\/td\u003e\n\u003ctd\u003ePre-routed internal connection eliminating standard external ClickLoc extension cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the housing is securely mounted. The 3\/4-14 NPT mounting thread (Option 02) must be fully engaged to ensure the structural integrity of the standoff adapter. Observe the manufacturer-recommended torque limits: apply 29.5 N-m (260 in-lb) to the retaining nut, and 39.3 N-m (350 in-lb) to the probe sleeve locknut. Ensure that sealing washers, plugs, and fittings are correctly installed to prevent moisture from traveling through conduits into the housing interior.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEuropean CE Mark compliant\u003c\/li\u003e\n\u003cli\u003eIP66 rating verified by BASEEFA (Report T07\/0709)\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals (Option 28): Intrinsically safe (Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc) and non-sparking\/increased safety (Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc) for zone-rated environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527875435,"sku":"330881-28-04-150-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-150-06-02-proxpac-xl-housing-sxwhfwprmw2_a794ff79-407c-4b0e-bce5-bbcb8cda6198.jpg?v=1765440306"},{"product_id":"bently-nevada-330180-x1-05mod-145193-01-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145193-01 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145193-01\u003c\/strong\u003e: This 3300 XL Proximitor Sensor is configured with Option X1 for DIN-rail mounting, Option 05 for multiple hazardous area agency approvals, and is custom-calibrated under modification 145193-01 for non-standard target materials.\u003c\/p\u003e\n\u003cp\u003eIn contrast to standard 330180 variants calibrated for AISI 4140 steel, this Proximitor sensor includes factory recalibration circuitry to maintain precise eddy-current measurement linearity on specific non-standard alloys. It integrates oscillator and detection electronics to condition proximity probe signals into a continuous displacement output, directly compatible with machinery protection monitors such as the Bently Nevada 3500 system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-rail mount form factor specified by option X1 for secure electrical enclosure mounting\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals under option 05 including ATEX, IECEx, and CSA intrinsic safety standards\u003c\/li\u003e\n\u003cli\u003eCustom target material calibration under Bently Nevada engineering modification MOD 145193-01\u003c\/li\u003e\n\u003cli\u003eConverts eddy-current RF signals into a continuous voltage output proportional to target distance\u003c\/li\u003e\n\u003cli\u003eSeamlessly integrates with 3300 XL 5mm\/8mm 9m proximity probes and extension cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position monitoring on high-speed industrial machinery\u003c\/li\u003e\n\u003cli\u003eHeavy industrial applications in power generation, oil and gas, petrochemical, and chemical processing\u003c\/li\u003e\n\u003cli\u003eSpecialized rotor dynamic analysis on turbomachinery utilizing non-standard shaft materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm Proximitor Sensor, 9-Meter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length and Mounting\u003c\/td\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Number\u003c\/td\u003e\n\u003ctd\u003eMOD:145193\u003c\/td\u003e\n\u003ctd\u003eTarget material recalibration modification family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eOption 01 under custom modification 145193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05MOD:145193-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m proximity probe and extension cable systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount (Option X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) linear analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils (0.25 to 2.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -24 Vdc input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.2 mm x 103.1 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Circuit ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eOutput displacement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTG (PROX)\u003c\/td\u003e\n\u003ctd\u003ePower supply (-24 Vdc input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eConnects to 3300 XL extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount securely on a standard 35 mm DIN rail in an environmentally protected enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation and shield grounding to prevent interference from external noise.\u003c\/li\u003e\n\u003cli\u003eConnect coaxial cable from the extension cable to the Proximitor coaxial connector, ensuring it is finger-tight.\u003c\/li\u003e\n\u003cli\u003eMaintain an appropriate probe-to-target gap matching the linear range of 10 to 90 mils.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx Intrinsically Safe (Option 05)\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D (Option 05)\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528006507,"sku":"330180-X1-05 MOD: 145193-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145193-01-3300-xl-proximitor-sensor-5w11ezz4jnd_f4825ce2-814e-4ef2-a538-253f1ab12228.jpg?v=1765440307"},{"product_id":"bently-nevada-330880-16-00-060-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-00-060-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-16-00-060-03-02\u003c\/strong\u003e is a PROXPAC XL English integrated proximity transducer configuration featuring an integrated 3300 XL 8 mm probe without hazardous area approvals (Option 16), no standoff adapter (Option 00), 6.0 inches of probe penetration (Option 060), specialized NPT reduction fittings (Option 03), and a 3\/4-14 NPT outer sleeve mounting thread (Option 02). This integrated assembly combines the 3300 XL 8 mm proximity probe and its associated Proximitor sensor directly into a single, self-contained protective housing, eliminating the requirement for an external extension cable or a separate remote housing. Field wiring from the system monitor terminates directly inside the junction area of the housing, reducing physical footprint, installation complexity, and potential cable failure points.\u003c\/p\u003e\n\n\u003cp\u003eUnlike hazardous area configurations like Option 28 (which includes multiple agency approvals for intrinsically safe and non-incendive zones), this Option 16 configuration is optimized for cost-effective implementation in non-hazardous industrial environments. The 6.0-inch penetration sleeve (Option 060) allows direct immersion into machine casings, with internal Neoprene O-ring seals providing IP66-rated protection. The heavy-duty polyphenylene sulfide (PPS) thermoplastic housing incorporates glass and conductive fibers to increase casing strength and effectively dissipate electrostatic charges, making the assembly well-suited for severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated proximity transducer design\u003c\/strong\u003e: Merges the 3300 XL 8 mm probe and the Proximitor sensor into a single, self-contained assembly to eliminate extension cable runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 16 probe configuration\u003c\/strong\u003e: Features a standard 3300 XL 8 mm probe without agency approvals, ideal for general-purpose, non-hazardous monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e6.0-inch penetration sleeve (Option 060)\u003c\/strong\u003e: Provides a 6.0 in (152 mm) rigid probe insertion depth into the machine case, adjustable within plus or minus 12.7 mm (0.5 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced PPS thermoplastic housing\u003c\/strong\u003e: Constructed from glass and conductive-fiber reinforced polyphenylene sulfide (PPS) to maximize casing strength and electrostatic discharge capability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 03 fittings kit\u003c\/strong\u003e: Includes one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs to simplify routing field conduits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 4X and IP66 rating\u003c\/strong\u003e: Provides protection against dust and high-pressure water jets, ensuring interior component safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined radial shaft vibration and axial shaft position monitoring on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained turbine casing or compressor frame installations where remote Proximitor enclosures are impractical.\u003c\/li\u003e\n  \u003cli\u003eSevere industrial environments requiring physical housing protection against water washdowns and dust ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-16-00-060-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 in (152 mm) penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required when mounting outer sleeve assembly)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-16-00-060-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe (1-metre internal cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 m of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced, UV-resistant polyphenylene sulfide (PPS) with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Environmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66 (verified by BASEEFA report T07\/0709)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing \u0026amp; Sensor Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Impact Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithstands two 4 Joule impacts at -39 degC and +115 degC (BASEEFA certified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjust probe gap by turning the threaded probe sleeve within the machine casing mounting threads.\u003c\/li\u003e\n  \u003cli\u003eThe mounting thread is 3\/4-14 NPT (Option 02) and should be properly sealed with standard thread sealant.\u003c\/li\u003e\n  \u003cli\u003eThe standard outer sleeve locknut torque is 39.3 N-m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003eEnsure the Neoprene O-ring is properly lubricated and seated between the probe sleeve and housing to maintain the IP66 ingress rating.\u003c\/li\u003e\n  \u003cli\u003eAvoid side-view and rear-view metallic interference on the probe tip by maintaining proper clearance relative to the surrounding machinery walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFCC Part 15 Compliant\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU (Standards: EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals: Option 16 is non-approved (designated for use in non-hazardous locations only)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666528891243,"sku":"330880-16-00-060-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-00-060-03-02-proximity-transducer-ql3pkwfhtu3_3a48fc5a-034a-40fe-8071-79835ef56ffb.jpg?v=1765440317"},{"product_id":"bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-00-20-038-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (no probe; Proximitor sensor only) and Option 20 (2.0 in standoff adapter) specify this 3300 XL PROXPAC integrated proximity transducer configuration - \u003cstrong\u003e330880-00-20-038-00-02\u003c\/strong\u003e. Designed with a 3.8 in probe penetration length (Option 038), the assembly provides a self-contained monitoring solution by placing the 3300 XL Proximitor sensor directly in the housing lid, eliminating the need for separate Proximitor housings and extension cables. This model does not include a probe sleeve fitting kit (Option 00) and features a standard 3\/4-14 NPT mounting thread (Option 02) for secure mechanical installation.\u003c\/p\u003e\n\u003cp\u003eBy combining the sensor and termination enclosure into a single, compact unit, this configuration reduces field wiring and installation complexity. Unlike configurations that include an integrated 3300 XL 8 mm probe or have hazardous area approvals, the 330880-00-20-038-00-02 serves as a non-approved replacement or customizable baseline housing assembly where the target probe and external conduit options are selected separately.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor:\u003c\/strong\u003e Cover-mounted 3300 XL Proximitor eliminates the need for separate signal conditioning housings and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolyphenylene Sulfide (PPS) Housing:\u003c\/strong\u003e Molded thermoplastic body reinforced with glass and conductive fibers offers excellent electrostatic dissipation and environmental protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Mechanical Adjustability:\u003c\/strong\u003e Features a 2.0 in (51 mm) standoff adapter length and 3.8 in (97 mm) probe penetration length to match specific machine case geometries.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Mounting Interface:\u003c\/strong\u003e Furnished with a robust 3\/4-14 NPT mounting thread for rigid connection to the machine case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 4X and IP66 Protection:\u003c\/strong\u003e Verified casing seals isolate the internal probe and electronics from hose-directed water and highly corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe integrated configuration is suitable for a variety of heavy-duty rotating machinery monitoring applications, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration measurements on steam turbines, gas turbines, and large compressors\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position monitoring on high-speed pumps and industrial gearboxes\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery protection where a compact, direct-to-monitor field wiring setup is required\u003c\/li\u003e\n  \u003cli\u003eCorrosive or high-humidity environments where metal enclosures are prone to degradation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (English Version)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo probe; Proximitor sensor without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (51 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e038\u003c\/td\u003e\n      \u003ctd\u003e3.8 in (97 mm) probe penetration length (0.1 in increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (Required if ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible Probe Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) with 3300 XL 8 mm probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimum: 50.8 mm (2.0 in); Recommended Minimum: 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Environment Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing\/Sensor Operating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor correct mounting and long-term mechanical reliability, observe the following engineering recommendations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total combined \"B\" plus \"C\" dimension does not exceed 305 mm (12 in) without providing additional probe sleeve support near the probe tip to avoid resonances.\u003c\/li\u003e\n  \u003cli\u003eEnsure the O-rings are lubricated and properly seated before assembly to maintain the IP66 ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003ePrevent water and solvent accumulation inside the housing cover by routing field wiring through conduit that slopes away from the housing.\u003c\/li\u003e\n  \u003cli\u003eDo not expose the probe tip to environments below -34 degC (-29 degF) prior to machine startup, as low temperatures may affect the pressure seal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n      \u003cth\u003eCompliance Classification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Union Directives\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X verified housing cover design\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529644907,"sku":"330880-00-20-038-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer-hkz5avir5a4_74ec7400-30cf-4191-a9ec-ca47473077cd.jpg?v=1765440336"},{"product_id":"bently-nevada-3500-42-proximitor®-seismic-monitor-module","title":"Bently Nevada 3500\/42 Proximitor® Seismic Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/42\u003c\/strong\u003e is a four-channel machinery protection card designed for the \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e series machinery protection system, providing continuous tracking of machinery vibration and displacement. This continuous-monitoring processing module accepts electrical signals from proximity sensors, velocity sensors, or accelerometers. The \u003cstrong\u003e3500\/42\u003c\/strong\u003e filters and scales these raw transducer waves into standard engineering variables, evaluating real-time operational health parameters such as radial shaft vibration, axial thrust position, eccentricity, acceleration, velocity, and differential expansion.\u003c\/p\u003e\n\u003cp\u003eOperating within a 3500 rack assembly, the module cross-references every active measurement channel against hardware-configured alert and danger setpoints. When programmed parameters exceed normal thresholds, the board drives immediate alarm signals over the rack backplane to trigger automatic interlock and equipment trip commands, independent of peripheral workstation software. The device layout includes individual channel pairing configurations and independent proportional recorder output loops to interface with plant management systems and external historians.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour-channel sensor processing matrix accepting concurrent proximity, velocity, or acceleration inputs.\u003c\/li\u003e\n\u003cli\u003eComprehensive functional programming supporting radial vibration, thrust position, eccentricity, and differential expansion.\u003c\/li\u003e\n\u003cli\u003eConfigurable input channels arranged in pairs to execute independent signal conditioning and tracking routines.\u003c\/li\u003e\n\u003cli\u003eFront-panel buffered transducer outputs providing immediate coaxial access for external dynamic diagnostic analyzers.\u003c\/li\u003e\n\u003cli\u003eRedundant 3500 backplane connectivity maintaining consistent channel parameter comparisons and safety interlock routing.\u003c\/li\u003e\n\u003cli\u003eDistinct front faceplate diagnostic indicators providing immediate status visibility for module OK, TX\/RX bus activity, and bypass modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous radial vibration and oil-film bearing breakdown tracking across critical plant turbo-compressors.\u003c\/li\u003e\n\u003cli\u003eDirect axial shaft thrust positioning and rotor displacement loops inside heavy-duty power generation steam turbines.\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy mechanical casing acceleration and structural velocity vibration cross-checks on large balance-of-plant motor skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor \/ Seismic Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 4 proximity, velocity, or acceleration transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Standard I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm (Proximitor and acceleration inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDirect \u0026amp; Gap Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.33% of full-scale typical, ±1% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc range across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Load Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBias Filter Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB at 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNot OK Filter Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB at 2400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Coaxial Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour dedicated buffered transducer output ports for dynamic waveform verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous green indicator displaying proper monitor and I\/O module health status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashing indicator tracking real-time message exchange on the rack communication bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBYPASS LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant indicator signaling that a channel parameter or alarm sequence is suppressed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Multi-Pin Array\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed connector pins establishing power links, input ties, and alarm control routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Guide the module chassis straight along the clear plastic slot tracks located to the right of the Rack Interface Module. Push firmly until the terminal array sits completely inside the backplane connectors, then secure the front panel thumbscrews.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Field Wiring:\u003c\/strong\u003e Route incoming sensor signal lines through dedicated, isolated instrumentation conduits. Terminate leads onto the companion rear-mounted I\/O terminal head assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Maintain continuous attachment to an approved electrostatic discharge wrist strap during unboxing or modification routines to safeguard internal analog processing chips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity Management:\u003c\/strong\u003e Land input cable shield drain wires onto the dedicated shield terminals provided on the I\/O block, keeping the sensor end ungrounded to eliminate standard ground loop noise induction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e3500\/42 vs. 3500\/42M: Key Differences \u0026amp; Selection Guide\u003c\/h3\u003e\n\u003cp\u003eWhen managing legacy machinery protection legacy networks or sourcing replacement parts for the \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e system, understanding the technical boundary lines between the standard \u003cstrong\u003e3500\/42\u003c\/strong\u003e and the enhanced \u003cstrong\u003e3500\/42M\u003c\/strong\u003e (Multimode) Proximitor\/Seismic Monitor is critical for plant compatibility.\u003c\/p\u003e\n\u003ch4\u003eArchitectural Comparison\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLegacy 3500\/42 Monitor\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEnhanced 3500\/42M Monitor\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarly baseline production series\u003c\/td\u003e\n\u003ctd\u003eLater generation Multimode series (Current OEM standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Programming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunctionally restricted per channel pair via physical onboard hardware jumpers\u003c\/td\u003e\n\u003ctd\u003eFully software-configurable per channel via 3500 Rack Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMixed Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLimited flexibility; channels must match specific jumper groups\u003c\/td\u003e\n\u003ctd\u003eHigh flexibility; allows concurrent pairing of proximity and seismic sensors within one card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced Signal Processing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard vibration, thrust position, and casing velocity tracking\u003c\/td\u003e\n\u003ctd\u003eSupports advanced algorithms including REBAM®, Shaft Absolute, and Circular Acceptance Region\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Rear I\/O Cards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140471-01 (Internal) \/ 140482-01 (External)\u003c\/td\u003e\n\u003ctd\u003e128229-01 (Internal) \/ 128240-01 (External)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSelection and Backward Compatibility Rules\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Legacy Replacement:\u003c\/strong\u003e If your current rack contains an original \u003cstrong\u003e3500\/42\u003c\/strong\u003e main monitor card that has suffered hardware degradation, the newer \u003cstrong\u003e3500\/42M\u003c\/strong\u003e can function as a complete functional replacement. It is fully backwards compatible with the overall 3500 chassis backplane communication bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe \"Matched Pair\" Mandatory Rule:\u003c\/strong\u003e You \u003cstrong\u003ecannot\u003c\/strong\u003e plug a \u003cstrong\u003e3500\/42M\u003c\/strong\u003e front monitor card into an older \u003cstrong\u003e3500\/42\u003c\/strong\u003e rear I\/O module (and vice versa). The internal trace layouts and electrical pinning paths are distinct. If you choose to upgrade a legacy slot to the 42M series, you must purchase and replace \u003cstrong\u003eboth the Front Monitor Card and the Rear I\/O Module as a matched set\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Redeployment:\u003c\/strong\u003e When replacing an old 3500\/42 with a 3500\/42M hardware bundle, field technicians must connect via the 3500 Rack Configuration Software, modify the designated slot definition type to \"3500\/42M\", map the original transducer metrics, and perform a fresh logic download to activate the slot.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531938667,"sku":"3500\/42","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42-proximitor-seismic-monitor-0uvaaynfrl1_ba527237-f7d2-4c33-9470-6b25869a7b65.jpg?v=1765440372"},{"product_id":"bently-nevada-330881-br-07-155-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-07-155-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-BR-07-155-06-02\u003c\/strong\u003e: This metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e features a 3300 XL 8 mm proximity probe with Brazil INMETRO hazardous area approvals (Option BR), an integrated 70 mm standoff adapter (Option 07), and a 155 mm probe penetration sleeve length (Option 155). This configuration is supplied with one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two conduit plugs (Option 06) and utilizes a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eThe integrated design combines both the 3300 XL 8 mm probe and its matching Proximitor sensor into a single, self-contained polyphenylene sulfide (PPS) housing. This approach eliminates the separate extension cable and external Proximitor enclosure, allowing field wiring to connect directly from the monitoring system to the terminal block inside the transducer cover. The glass- and conductive-fiber-reinforced PPS housing delivers IP66 and Type 4X environmental protection, securing the internal electronics against severe industrial conditions, moisture ingress, and electrostatic buildup.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR includes a 3300 XL 8 mm probe certified with Brazil INMETRO approvals for intrinsic safety and non-sparking hazardous area protection.\u003c\/li\u003e\n  \u003cli\u003eOption 07 provides a 70 mm standoff adapter length to elevate the enclosure above the machine casing.\u003c\/li\u003e\n  \u003cli\u003eOption 155 designates a 155 mm probe penetration sleeve length to match target depth specifications.\u003c\/li\u003e\n  \u003cli\u003eOption 06 includes a heavy-duty 3\/4-14 NPT conduit fitting, a 1 1\/2-14 NPT stainless steel reducer, and dual blanking plugs.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread to ensure a robust mechanical connection.\u003c\/li\u003e\n  \u003cli\u003eSelf-contained design eliminates external extension cables and remote Proximitor enclosures to reduce wiring errors and simplify installation.\u003c\/li\u003e\n  \u003cli\u003eConductive PPS thermoplastic housing dissipates electrostatic charges and resists ultraviolet radiation and aggressive chemicals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring where a simplified transducer footprint and direct terminal field wiring are preferred.\u003c\/li\u003e\n  \u003cli\u003eSevere-duty applications requiring IP66 and Type 4X corrosion-resistant housing protection.\u003c\/li\u003e\n  \u003cli\u003eHazardous locations requiring INMETRO-certified intrinsic safety or non-sparking configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-BR-07-155-06-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric Model)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Brazil \/ INMETRO approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e07\u003c\/td\u003e\n      \u003ctd\u003e70 mm standoff adapter length (ordered in increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e155\u003c\/td\u003e\n      \u003ctd\u003e155 mm probe sleeve penetration length (ordered in increments of 1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-07-155-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Input Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegral 1-meter cable pre-connected within the housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting 0.25 mm (10 mils) from target to 2.3 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% over linear range (0 to 45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinearity Deviation (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) deviation from standard straight line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 +\/-0.50 Ohm (nominal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass- and conductive-fiber-reinforced polyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRetaining Screws and Outer Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRetaining Nut: 29.5 N-m (260 in-lb); Probe Sleeve Locknut: 39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Terminals\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Wiring Connection\u003c\/td\u003e\n      \u003ctd\u003eScrew terminal block inside the housing lid\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Wire Capacity\u003c\/td\u003e\n      \u003ctd\u003eAccepts wire sizes from 0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Field Cable\u003c\/td\u003e\n      \u003ctd\u003e3-conductor shielded triax cable with tinned field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Distance to Monitor\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1,000 feet) between PROXPAC XL and monitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the housing securely using the 3\/4-14 NPT thread. Ensure the standoff adapter is aligned correctly with the machinery sleeve port. Tighten the probe sleeve locknut to a torque of 39.3 N-m (350 in-lb) and the retaining nut to 29.5 N-m (260 in-lb) to maintain a secure physical seal. Field cables must be routed through the conduit fittings provided by Option 06; tighten all compression fittings and plugs to maintain the IP66 and Type 4X rating of the PPS enclosure. Ensure local grounding guidelines are followed using the integrated internal ground liner assembly.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis transducer assembly is designed and certified under the following industrial standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark compliance\u003c\/li\u003e\n  \u003cli\u003eIP66 rating (verified by BASEEFA report T07\/0709)\u003c\/li\u003e\n  \u003cli\u003eType 4X enclosure protection\u003c\/li\u003e\n  \u003cli\u003eINMETRO \/ Brazil Approvals (Option BR) for intrinsic safety (Ex ia) and non-sparking (Ex nA\/ec) in explosive gas atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533347691,"sku":"330881-BR-07-155-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-07-155-06-02-tsi-module-snce4kndaio_ce2e3e91-022f-4c4e-b36a-19552e157cd1.jpg?v=1765440386"},{"product_id":"bently-nevada-330180-x1-cn-mod-143416-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD:143416-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN MOD:143416-05\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis \u003cmark\u003ea high-precision Eddy Current Proximitor Sensor belonging to the\u003cspan\u003e \u003c\/span\u003e3300 XL\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Transducer System\u003c\/mark\u003e.\u003cspan\u003e \u003c\/span\u003eThis specific unit handles both static displacement (position) and dynamic displacement (vibration) measurements on critical rotating machinery components. The device translates the distance between an 8 mm probe tip and the observed conductive target surface into a proportional analog voltage signal. The\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003econfiguration specifies a 35 mm DIN rail mount layout, while the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esuffix denotes localized safety compliance, including ATEX\/IECEx and Chinese NEPSI hazardous area approvals. The structural designation\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003erepresents a factory-calibrated modification engineered to provide enhanced electrical durability and target profile optimization inside heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable class=\"NRefec\" width=\"628\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eParameter\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eOrdering Code Extension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eX1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eModification Reference Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eProximitor Proximity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\n\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Transducer Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eMounting Hardware Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e35 mm Standard DIN Rail Mount (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eHazardous Area Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eATEX, IECEx, NEPSI Chinese Markings (\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSensor Operating Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eEddy Current Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eFrequency Response Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eNominal Target Diameter Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e8 mm Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Output Signal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eContinuous Analog AC\/DC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Height\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Depth \/ Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e2.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eProduct Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eBecause Bently Nevada transducer components feature internal matching circuits calibrated to exact system loop lengths, procurement must specify both the core part configurations and factory modification tags.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eComponent Part Number:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180-X1-CN\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eFactory Modification Suffix:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eSystem Family Code:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Series\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Engineering Guide\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch4\u003eTotal Loop Length Verification\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esensor must be paired with an 8 mm probe and extension cable matching the precise overall electrical system length (typically 5.0 meters or 9.0 meters total). Mismatching a 5-meter proximitor module with a 9-meter cable array shifts the eddy current oscillation baseline, resulting in severe scale factor errors, zero-point drift, and inaccurate machine vibration readings.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eRFI Immunity and Enclosure Grounding\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e3300 XL\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esensor design features advanced radio frequency interference (RFI) shielding, satisfying European CE mark parameters without requiring special steel conduits. However, the physical DIN rail mounting strip (\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e) must have a direct low-impedance electrical bond to the instrument enclosure ground rail. Avoid mounting the Proximitor board immediately adjacent to high-power variable frequency drive (VFD) output cables or contactor blocks.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nexinstrument.com\/330180-x1-cn-mod-143416-34.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eField Coaxial Connector Protection\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe coaxial links connecting the field probe lead to the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emodule are highly sensitive to moisture, grease, and mechanical stress. Use specialized connector silicone sleeves during assembly to insulate the raw coaxial threads. Ensure the extension cable minimum bend radius of 25.4 mm (1.0 inch) is strictly observed within the cabinet wire trays to prevent micro-cracks in the inner shield layers.\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the MOD:143416-05 suffix designate?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eMOD:143416-05\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edesignation identifies a factory-engineered modification applied directly to the internal tuning parameters of the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003e330180\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eseries. This often dictates a altered calibration profile to accommodate non-standard shaft target materials, customized signal gains, or specialty protective coatings on the outer housing block.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003ca class=\"muU3oe\" href=\"https:\/\/www.nordwel.com\/bently-nevada-330180-x1-cn-mod-143416-05-proximitor-sensor_p16754.html\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"wJwe6c\"\u003e\u003cspan class=\"IjM6od\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this sensor hot-swappable while the TSI monitoring rack is online?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Proximitor sensor can be replaced while the primary monitoring rack (such as a Bently Nevada 3500 rack) remains powered up. However, disconnecting the sensor will immediately open the loop circuit, driving the corresponding rack channel into an \"Unstable\/Fault\" state. Bypass or inhibit any automated trip relays before swapping the hardware to avoid accidental machinery shutdown.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the X1 and CN tags signify in the ordering configuration?\u003c\/strong\u003e\u003cspan class=\"txxDge notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003cspan class=\"wiMplc ofC0Ud\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eX1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003econfiguration ensures the Proximitor sensor housing comes fitted with an integrated structural foot designed for standard DIN rail clip mounting. The\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Yjhzub\"\u003eCN\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003edesignation indicates that the product adheres to specific regional requirements for China, carrying the NEPSI hazardous area explosion-proof stamps along with ATEX\/IECEx data.\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"uJ19be notranslate\"\u003e\u003cspan class=\"vKEkVd\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533445995,"sku":"330180-X1-CN MOD:143416-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-143416-05-proximity-interface-module-ir4xttrnbna_19ca2830-6c66-4cb4-aed3-2151e21bb306.jpg?v=1765440387"},{"product_id":"bently-nevada-330881-28-07-155-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-07-155-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-07-155-06-02\u003c\/strong\u003e: This metric \u003cstrong\u003ePROXPAC XL proximity transducer\u003c\/strong\u003e configuration features a 3300 XL 8 mm probe with multiple approvals (Option 28), a 70 mm standoff adapter (Option 07), 155 mm of probe penetration depth (Option 155), a specialized fittings kit (Option 06), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eIn contrast to non-approved configurations or variants lacking a standoff adapter, this assembly integrates a robust, certified monitoring chain inside a durable Polyphenylene Sulfide (PPS) housing. The PROXPAC XL combines the probe and Proximitor sensor into a single integrated system, reducing external field wiring requirements by connecting directly to Bently Nevada monitors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28 integrates a 3300 XL 8 mm probe certified with Multiple Approvals for hazardous locations.\u003c\/li\u003e\n\u003cli\u003eOption 07 specifies a 70 mm metric standoff adapter to position the assembly clear of obstruction.\u003c\/li\u003e\n\u003cli\u003eOption 155 provides 155 mm of probe penetration length into the machine case.\u003c\/li\u003e\n\u003cli\u003eOption 06 supplies a fittings kit containing one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 establishes a 3\/4-14 NPT mounting thread for the outer sleeve assembly.\u003c\/li\u003e\n\u003cli\u003eGlass and conductive fiber-reinforced Polyphenylene Sulfide (PPS) thermoplastic housing construction provides IP66 ingress protection and static charge dissipation.\u003c\/li\u003e\n\u003cli\u003eDirect-connect design integrates the Proximitor sensor directly into the housing cover, eliminating the need for an intermediate extension cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include shaft vibration and axial position measurement on industrial rotating machinery, steam and gas turbines, centrifugal compressors, and large pumps where reduction of external wiring and junction boxes is required.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Parameter\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-07-155-06-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e70 mm standoff length (Option B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e155 mm penetration length (Option C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n\u003ctd\u003e330881-28-07-155-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Output\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Diameter (Minimum)\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable\u003c\/td\u003e\n\u003ctd\u003e1-metre length, 75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Connector\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material \u0026amp; Retaining Chain\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner \u0026amp; Retaining Plate\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid Label Material\u003c\/td\u003e\n\u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 \/ Type 4X verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Housing \u0026amp; Proximitor Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the outer sleeve assembly into the machine case using thread sealant on the mounting thread (3\/4-14 NPT). Adjust the probe gap within the housing using the probe sleeve locknut (torque to 39.3 N-m \/ 350 in-lb). Fasten the lid cover retaining nuts to 29.5 N-m (260 in-lb). Take standard industrial precautions to prevent external moisture from travelling through the conduit directly into the housing.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eCE compliant. BASEEFA IP66 housing rating. Multiple Approvals package option includes certifications for hazardous locations (CSA, ATEX, IECEx where applicable).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666537509227,"sku":"330881-28-07-155-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-07-155-06-02-proxpac-xl-proximity-transducer-qnj0v05fasj_5753b3e4-fffd-4751-8d80-6c86cae606ef.jpg?v=1765440430"},{"product_id":"bently-nevada-330881-br-04-70-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-70-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-BR-04-70-03-02\u003c\/strong\u003e specifies a metric configuration of the Bently Nevada PROXPAC XL Proximity Transducer, integrating an 8 mm probe with multiple hazardous area approvals (Option BR) into a self-contained protective assembly. This integrated setup couples a 3300 XL 8 mm probe and a 3300 XL Proximitor sensor within a single, machine-mounted polyphenylene sulfide (PPS) housing. This engineering approach eliminates the need for external extension cables and standalone Proximitor enclosures, allowing field wiring to run directly from the housing to the monitoring system.\u003c\/p\u003e\n\n\u003cp\u003eFor precise mechanical adjustment and alignment, this variant features a 40 mm standoff adapter (Option 04) and a 70 mm probe penetration length (Option 70). Environmental integrity is maintained by the glass-and-conductive-fiber-reinforced PPS body, which effectively dissipates electrostatic charges and is rated for IP66 and NEMA Type 4X environments. This specific metric configuration is supplied with one M20 fitting and two blanking plugs (Option 03) for electrical conduit entry, and utilizes a 3\/4-14 NPT thread (Option 02) for secure mounting to the machine casing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Assembly Design\u003c\/strong\u003e: Combines a 3300 XL 8 mm probe and Proximitor sensor inside a single enclosure, eliminating separate extension cables and dedicated remote transmitter housings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Hazardous Area Approvals\u003c\/strong\u003e: Option BR (the designator corresponding to Option 28 in Bently Nevada metric documentation) certifies the assembly for ATEX, IECEx, and CSA hazardous area classifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Depth\u003c\/strong\u003e: Includes a 70 mm probe penetration sleeve (Option 70) and a 40 mm standoff adapter (Option 04) for precise positioning of the sensor tip.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant PPS Housing\u003c\/strong\u003e: Molded thermoplastic reinforced with glass and conductive fibers provides robust chemical, UV, and impact resistance alongside electrostatic dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP66 and Type 4X Ratings\u003c\/strong\u003e: Engineered for direct machine mounting in severe industrial environments, offering high protection against moisture, dust, and washdowns.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Conduit Entries\u003c\/strong\u003e: Includes one M20 connection fitting and two plugs (Option 03) to prevent environmental ingress at the cable entry ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe system is used for continuous, non-contact shaft vibration and axial position measurements in rotating machinery. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbines and gas turbines in power generation plants.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors and pumps in oil, gas, and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003eLarge industrial fans, blowers, and gearboxes.\u003c\/li\u003e\n  \u003cli\u003eSevere-duty or space-constrained locations where remote Proximitor housings cannot be easily installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from PDF\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals (equivalent to option code 28)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003e70 mm probe penetration sleeve length (070)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-70-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Terminal Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG); 3-conductor shielded triax recommended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) between Proximitor sensor and monitoring system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \/ Adapter Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 and AISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLocknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Grounding\u003c\/strong\u003e: The internal grounding liner and retaining plate must be connected properly. Ground the field wiring shield exclusively at the monitor end to eliminate potential ground loop interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Integrity\u003c\/strong\u003e: Use the 3\/4-14 NPT mounting thread to engage with the machine casing. Apply the standard torque of 39.3 N-m (350 in-lb) on the locknut and 29.5 N-m (260 in-lb) on the retaining nut.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibration Target Gap\u003c\/strong\u003e: Set the recommended gap distance to 1.27 mm (50 mils) to establish the -10 Vdc nominal center bias voltage within the 2 mm linear measurement window.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Entries\u003c\/strong\u003e: Securely thread the supplied M20 fitting. Plug all unused entry ports using the supplied blanking plugs to preserve the IP66 and NEMA Type 4X environmental seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection\u003c\/strong\u003e: IP66 (verified by BASEEFA) and NEMA Type 4X\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option BR)\u003c\/strong\u003e: ATEX, IECEx, and CSA certified for Class I Division 1 (Groups A, B, C, D) and Ex ia IIC T4\/T5 Ga intrinsically safe applications when installed per Bently Nevada drawing 141092.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666540786027,"sku":"330881-BR-04-70-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-70-03-02-proxpac-xl-proximity-transducer-koeckaklyin_2a7b3143-0755-4a7b-bbdf-c06ccee219f1.jpg?v=1765440463"},{"product_id":"bently-nevada-330880-28-15-035-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 15 (1.5 in standoff adapter) specify this \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration — \u003cstrong\u003e330880-28-15-035-00-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis integrated proximity transducer assembly combines the probe and Proximitor sensor into a single polyphenylene sulfide (PPS) housing. The self-contained design eliminates the need for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. Field wiring connects directly between the monitors and the internal terminals. This configuration features a 3.5 in probe penetration depth (Option 035), no conduit fittings (Option 00), and a 3\/4-14 NPT mounting thread (Option 02) suitable for severe industrial machinery case interfaces.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTransducer probe with multiple hazardous area approvals (ATEX, IECEx, and CSA) for explosion-proof and intrinsically safe installations.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor in the housing lid to eliminate external extension cables.\u003c\/li\u003e\n  \u003cli\u003eConductive glass-fiber-reinforced polyphenylene sulfide (PPS) thermoplastic housing rated IP66 and Type 4X.\u003c\/li\u003e\n  \u003cli\u003e1.5 in (38 mm) standoff adapter with a 3\/4-14 NPT thread for rigid casing mounting.\u003c\/li\u003e\n  \u003cli\u003e3.5 in (89 mm) stainless steel probe sleeve length for direct case penetration.\u003c\/li\u003e\n  \u003cli\u003eSupplied with two plugs and two washers under the no-fittings option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eDirect integration on turbines, compressors, pumps, and industrial gearboxes.\u003c\/li\u003e\n  \u003cli\u003eEnvironments requiring IP66 or Type 4X protection against chemical exposure, moisture, and dust.\u003c\/li\u003e\n  \u003cli\u003eHazardous industrial environments requiring intrinsically safe or non-incendive field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e330880-28-15-035-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 in (38 mm) standoff length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e035\u003c\/td\u003e\n      \u003ctd\u003e3.5 in (89 mm) penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330880-28-15-035-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Component\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Requirement\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB) with up to 305 m (1000 ft) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShaft Diameter Limits\u003c\/td\u003e\n      \u003ctd\u003eMinimum 50.8 mm (2.0 in), Recommended 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced conductive polyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case and Sleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature (Housing\/Sensor)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X when properly sealed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTorque the housing retaining nut to 29.5 N-m (260 in-lb).\u003c\/li\u003e\n  \u003cli\u003eTorque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain the environmental pressure seal.\u003c\/li\u003e\n  \u003cli\u003eVerify that the internal grounding liner and retaining plate are clean and securely fastened.\u003c\/li\u003e\n  \u003cli\u003eEnsure field wiring terminals are protected by an enclosure of at least IP54.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum separation of 40 mm (1.6 in) for axial installations or 38 mm (1.5 in) for radial configurations to avoid cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eATEX\/IECEx\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc (Intrinsically Safe); Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc (Non-sparking)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNorth American (cNRTLus)\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Intrinsically Safe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNon-Incendive\u003c\/td\u003e\n      \u003ctd\u003eClass I, Division 2, Groups A, B, C, D; Class I, Zone 2: AEx\/Ex nA IIC T4\/T5 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCE Mark\u003c\/td\u003e\n      \u003ctd\u003eComplies with European directives\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541277547,"sku":"330880-28-15-035-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-15-035-00-02-proxpac-xl-proximity-transducer-assembly-crqcbgmfy4r_5e47900b-f87c-4c72-b762-dc57faaefd73.jpg?v=1765440470"},{"product_id":"bently-nevada-330880-28-35-017-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-35-017-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-28-35-017-00-02\u003c\/strong\u003e: English-unit PROXPAC XL Proximity Transducer assembly configured with a 3300 XL 8 mm proximity probe with multiple approvals (Option 28), a 3.5 in (89 mm) standoff adapter length (Option 35), a 1.7 in (43 mm) probe penetration depth (Option 017), without conduit fittings (Option 00), and a 3\/4-14 NPT mounting thread sleeve (Option 02).\u003c\/p\u003e\n\u003cp\u003eThis integrated design houses a 3300 XL 8 mm proximity probe and its matching Proximitor sensor directly within the glass-reinforced polyphenylene sulfide (PPS) thermoplastic probe housing. By combining both elements in a single Type 4X and IP66 rated enclosure, this configuration eliminates the requirement for an external extension cable and separate Proximitor sensor housing. Field wiring connects directly from the terminal block inside the housing to the monitoring system, simplifying physical mounting and electrical installation in severe industrial environments. The integrated 3300 XL 8 mm probe operates on standard eddy-current principles to measure shaft vibration and axial position on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated assembly houses both the 3300 XL 8 mm proximity probe and matching Proximitor sensor inside a single enclosure.\u003c\/li\u003e\n\u003cli\u003eOption 28 specifies a 3300 XL 8 mm probe equipped with Multiple Approvals (such as CSA, ATEX, and IECEx) for installation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eOption 35 provides a 3.5 in (89 mm) standoff adapter for extending the housing from the machinery casing.\u003c\/li\u003e\n\u003cli\u003eOption 017 sets a probe penetration length of 1.7 in (43 mm) into the machine casing.\u003c\/li\u003e\n\u003cli\u003eOption 00 designates the assembly is supplied without auxiliary conduit fittings, including two plugs and two washers.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a 3\/4-14 NPT mounting thread sleeve for mechanical connection.\u003c\/li\u003e\n\u003cli\u003eEnclosure is constructed from molded ultraviolet (UV) resistant glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers to dissipate electrostatic charges.\u003c\/li\u003e\n\u003cli\u003eSealing rating of Type 4X and IP66 provides ingress protection against moisture and dust in severe environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial shaft vibration and axial shaft position measurements on rotating industrial machinery.\u003c\/li\u003e\n\u003cli\u003eSevere industrial environments such as oil and gas refineries, petrochemical plants, and power generation facilities.\u003c\/li\u003e\n\u003cli\u003eRetrofitting machinery housings where a separate Proximitor junction box cannot be accommodated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eConfiguration Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-28-35-017-00-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, English Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e3.5 in (89 mm) standoff adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e017\u003c\/td\u003e\n\u003ctd\u003e1.7 in (43 mm) probe penetration depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings (supplied with two plugs and two washers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required for standoff adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-28-35-017-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe (installed in sleeve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 m \/ 1000 ft of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from the target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLid Label Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X \/ IP66 rated housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Impact Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBASEEFA certified to 4 Joules at -39 degC and 115 degC; CSA verified to 7 Joules at ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\/Sensor Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the outer sleeve is properly mounted to the machine case using the 3\/4-14 NPT mounting thread option (Option 02) to maintain a secure and vibration-isolated connection. Standard tightening torques should be applied: the retaining nut must be torqued to 29.5 N-m (260 in-lb) and the probe sleeve locknut to 39.3 N-m (350 in-lb). Grounding liner and retaining plate components must be correctly seated to prevent electrostatic charge build-up. All conduit runs should be properly sealed to prevent external moisture and condensation from traveling through the conduit and entering the transducer housing.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis transducer system is certified to comply with the European Union CE mark, EMC Directive 2014\/30\/EU (Standards EN 61000-6-2 and EN 61000-6-4), and RoHS Directive 2011\/65\/EU. Hazardous area approvals are governed by CSA\/NRTL\/US and ATEX\/IECEx standards. The system is certified for Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga, and Class I, Division 2, Groups A, B, C, D environments when installed with appropriate intrinsic safety barriers or galvanic isolators according to control drawings. The housing is independently rated to meet Type 4X and IP66 ingress protection criteria.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666542817643,"sku":"330880-28-35-017-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-35-017-00-02-proximity-transducer-jzk2zjqqkcn_0eb5d17b-f451-4b11-b43e-058c21064e54.jpg?v=1765440487"},{"product_id":"bently-nevada-330881-br-04-110-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-110-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR (3300 XL 8 mm probe with INMETRO approvals) and Option 04 (40 mm standoff adapter) specify the configuration of this metric integrated proximity transducer assembly — \u003cstrong\u003e330881-BR-04-110-06-02 PROXPAC XL proximity transducer\u003c\/strong\u003e. The self-contained design integrates a 3300 XL Proximitor sensor directly into the housing cover, eliminating the need for separate extension cables and external Proximitor junction boxes. Field wiring connects directly inside the terminal area, simplifying layout and reducing total system wiring complexity.\u003c\/p\u003e\n\u003cp\u003eThe molded polyphenylene sulfide (PPS) thermoplastic housing is reinforced with glass and conductive fibers, providing mechanical strength and dissipating electrostatic charges in hazardous areas. This configuration features a 110 mm probe penetration sleeve, NPT conduit fittings, and a 3\/4-14 NPT mounting thread. It operates using non-contact eddy-current technology to measure dynamic shaft vibration and axial position on industrial rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMolded polyphenylene sulfide (PPS) thermoplastic housing rated for Type 4X and IP66 severe environments.\u003c\/li\u003e\n  \u003cli\u003eGlass and conductive fibers incorporated into the PPS material to safely dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eSelf-contained design with the Proximitor sensor integrated in the housing lid to eliminate external probe-to-sensor cabling.\u003c\/li\u003e\n  \u003cli\u003eThreaded sleeve adjustment mechanism allowing up to plus or minus 12.7 mm of axial movement for fine gap positioning.\u003c\/li\u003e\n  \u003cli\u003eInternal vibration isolation utilizing extra-soft cellular silicone to protect internal components from structural vibration.\u003c\/li\u003e\n  \u003cli\u003eField wiring terminals designed to accept tinned wire sizes from 0.2 to 1.5 mm2 (16 to 24 AWG).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDynamic shaft radial vibration monitoring on critical rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position and thrust displacement measurements on utility and industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eApplications requiring INMETRO (Brazil) hazardous area approvals for safe operation.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or high-moisture processing environments where Type 4X and IP66 environmental sealing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eSelected Code\u003c\/th\u003e\n      \u003cth\u003eOption Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length (Dimension B)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e110\u003c\/td\u003e\n      \u003ctd\u003e110 mm probe penetration sleeve length (Dimension C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-110-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), beginning at approximately 0.25 mm (10 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temp. (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temp. (Probe Only)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer is mounted using the 3\/4-14 NPT threads. The axial sleeve provides up to plus or minus 12.7 mm of threaded travel to accurately adjust the probe gap prior to final locking. For penetration lengths (\"B\" standoff plus \"C\" penetration) exceeding 305 mm, an additional sleeve support must be installed near the probe tip to minimize resonance and deflection. Terminate the field wiring inside the housing cover using tinned conductors sized between 0.2 and 1.5 mm2 (16 to 24 AWG).\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eINMETRO (Brazil) Hazardous Area Approvals for Intrinsic Safety and Non-Incendive installations.\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant.\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU compliant.\u003c\/li\u003e\n  \u003cli\u003eIP66 and Type 4X environmental protection classifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544357739,"sku":"330881-BR-04-110-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-110-06-02-proxpac-xl-housing-pwfrsps2bhp_6b9c29bc-5b2b-43cc-8c5f-e637ab6eaa35.jpg?v=1765440502"},{"product_id":"bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor","title":"Bently Nevada 330850-91-00 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-91-00\u003c\/strong\u003e specifies a \u003cstrong\u003e3300 XL 25 mm Proximitor Sensor\u003c\/strong\u003e configured with a 9.0 m system length and DIN rail mounting, intended for installations requiring no hazardous area certifications.\u003c\/p\u003e\n\u003cp\u003eThis sensor forms an integral part of the 3300 XL 25 mm Proximity Transducer System, which is designed for non-contact, large-target eddy-current displacement measurements, specifically for steam turbine differential expansion (DE) and casing expansion. By processing the high-frequency RF signal from a 330851 proximity probe and 330854 extension cable, the Proximitor sensor provides a scaled analog output of 0.787 V\/mm (20 mV\/mil). Compared to panel-mount or alternative 5.0 m configurations, this 9.0 m DIN-mount version offers extended system reach and convenient standard DIN rail installation inside local instrument enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 91 specifies a 9.0 m system length with integrated DIN rail mounting hardware.\u003c\/li\u003e\n\u003cli\u003eOption 00 provides a standard configuration without hazardous area agency approvals.\u003c\/li\u003e\n\u003cli\u003eCompatible with the Bently Nevada 3300 XL 25 mm series proximity probes and extension cables.\u003c\/li\u003e\n\u003cli\u003eDelivers a nominal Average Scale Factor of 0.787 V\/mm (20 mV\/mil) over a 12.7 mm (500 mils) linear range.\u003c\/li\u003e\n\u003cli\u003eAccepts power supply inputs ranging from -17.5 Vdc to -26 Vdc.\u003c\/li\u003e\n\u003cli\u003eMaintains a constant 50 ohm output resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine differential expansion (DE) monitoring\u003c\/li\u003e\n\u003cli\u003eRotor casing expansion measurement\u003c\/li\u003e\n\u003cli\u003eLarge-target eddy-current displacement applications\u003c\/li\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eHeavy industrial rotating machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption AA - Total Length and Mounting\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e9.0 metres (29.5 feet) system length, DIN mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption BB - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330850-91-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximity Transducer System (330851 probes, 330854 cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils), beginning at approximately 0.63 mm (25 mils) from target (from 0.63 to 13.33 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eApproximately -1.5 Vdc to -11.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical with up to 305 metres of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Minimum Target Size\u003c\/td\u003e\n\u003ctd\u003e61 mm (2.4 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +100 Celsius (-60 Fahrenheit to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +105 Celsius (-60 Fahrenheit to +221 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m (combined probe and extension cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mount (Option 91)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) (sensor only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal installation of the 330850 DIN-mount Proximitor sensor, ensure it is secure on a standard 35 mm DIN rail. Secure the field wiring terminals (0.2 to 1.5 mm2 or 16 to 24 AWG) using a shielded triad cable with a maximum length of 305 metres (1000 feet) to the monitoring system. Keep the coaxial connectors between the extension cable and the probe finger-tight, or torque to a maximum of 0.565 N-m (5 in-lb). The Proximitor must be housed in a clean, dry enclosure providing at least IP54 protection to prevent exposure to moisture and contamination.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis device complies with the European CE mark requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545471851,"sku":"330850-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor-kqn4tpazt2e_52780fc8-0130-4fce-befe-d29ffb0c362a.jpg?v=1765440516"},{"product_id":"bently-nevada-330880-28-20-038-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-28-20-038-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 20 (2.0 in standoff adapter) specify the exact mechanical and electrical layout of this \u003cstrong\u003e330880-28-20-038-00-02\u003c\/strong\u003e integrated \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly. This design integrates a 3300 XL 8 mm proximity probe and its matching 1-metre Proximitor sensor directly into a single, robust housing cover. By consolidating these components, the assembly eliminates the need for separate extension cables and dedicated Proximitor housings. The field wiring connects directly inside the terminal compartment of the transducer housing, significantly simplifying system design, decreasing connector-related signal losses, and reducing overall installation costs.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration is built with an Option 038 probe penetration length of 3.8 inches (97 mm) and is supplied under Option 00 (no conduit fittings; includes two sleeve plugs and two washers). It utilizes Option 02, providing a 3\/4-14 NPT outer sleeve mounting thread to secure the unit to the machinery casing. The housing itself is molded from a high-durability, UV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic embedded with conductive fibers to dissipate static charges. Sibling configurations within this family vary by offering metric mounting threads, different standoff adapter lengths, or pre-packaged conduit fittings, making this specific English-threaded, 3.8-inch penetration unit the ideal configuration for standardized medium-depth machine cases.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 Probe Integration: Features a pre-installed 3300 XL 8 mm proximity probe with Multiple Approvals (CSA, ATEX, IECEx) for hazardous area conditions.\u003c\/li\u003e\n  \u003cli\u003eOption 20 Standoff Length: Includes a 2.0 in (51 mm) standoff adapter to adjust probe positioning relative to the target shaft.\u003c\/li\u003e\n  \u003cli\u003eOption 038 Sleeve Penetration: Outfitted with a 3.8 in (97 mm) probe sleeve length suitable for medium-depth machine case penetration.\u003c\/li\u003e\n  \u003cli\u003eOption 00 Fittings Package: Shipped without external conduit fittings, containing instead two plastic plugs and two washers for standard sealing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 Mounting Thread: Utilizes a standard 3\/4-14 NPT outer sleeve thread to secure the standoff adapter.\u003c\/li\u003e\n  \u003cli\u003eGlass-Reinforced PPS Housing: Constructed from advanced molded thermoplastic containing conductive fibers to strengthen the outer shell and prevent electrostatic hazards.\u003c\/li\u003e\n  \u003cli\u003eSelf-Contained Design: Minimizes cable management overhead by housing both probe and sensor elements in a single IP66 and Type 4X rated enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring on high-speed rotating shafts in steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n  \u003cli\u003eSimplified field installations where separate Proximitor enclosures are impractical due to physical layout constraints.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or highly humid industrial environments, including petrochemical refineries, power plants, and gas processing facilities.\u003c\/li\u003e\n  \u003cli\u003eDirect integration with Bently Nevada 3500 and 3300 machinery protection monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English threads and sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (51 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e038\u003c\/td\u003e\n      \u003ctd\u003e3.8 in (97 mm) probe sleeve penetration length (C dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-28-20-038-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntegrated Sensor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) up to 2.3 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -17 Vdc over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over 0 to +45 degC (+32 to +113 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/- 0.025 mm (+\/- 1 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating: -52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment:\u003c\/strong\u003e The threaded sleeve design allows for a mechanical adjustment of +\/- 12.7 mm (+\/- 0.5 in) from the nominal insertion point. Ensure the probe is gapped to the standard 1.27 mm (50 mils) before securing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRequired Torque:\u003c\/strong\u003e Tighten the housing retaining nut to 29.5 N-m (260 in-lb) and the outer probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain a secure process seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Sealing:\u003c\/strong\u003e Users must seal all conduit entries to prevent moisture from traveling through the field conduit into the main terminal compartment. Tighten the lid screws properly to maintain Type 4X and IP66 protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Ensure the internal metallic grounding liner and plate are properly integrated into the system ground loop to effectively dissipate electrostatic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (CSA):\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European Community Directive EMC 2014\/30\/EU and RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e Rated for Type 4X and IP66 environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666553991531,"sku":"330880-28-20-038-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-28-20-038-00-02-proximity-transducer-mc0hs1izr4b_e388e5d1-c09c-4896-b486-bd6a52e7027c.jpg?v=1765440603"},{"product_id":"bently-nevada-330881-br-04-150-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-150-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies an integrated 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals in this metric configuration of the \u003cstrong\u003eBently Nevada 330881-BR-04-150-06-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e. It combines a proximity probe and a Proximitor sensor into a single self-contained housing, removing the requirement for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. The direct field-wiring connection streamlines installation on rotating machinery and reduces overall loop complexity.\u003c\/p\u003e\n\u003cp\u003eThe housing is constructed from glass-reinforced polyphenylene sulfide (PPS), a tough thermoplastic engineered to dissipate electrostatic charges and resist corrosive environmental exposure. Rated for Type 4X and IP66, this assembly ensures ingress protection in severe industrial environments. This specific configuration includes a 40 mm standoff adapter and a 150 mm probe penetration sleeve with a 3\/4-14 NPT mounting thread and a robust NPT fittings kit for conduit routing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated design embeds a 3300 XL Proximitor sensor directly into the housing lid to eliminate extension cables and junction boxes.\u003c\/li\u003e\n\u003cli\u003eOption BR provides INMETRO approvals for safe deployment in Brazilian hazardous areas.\u003c\/li\u003e\n\u003cli\u003ePPS thermoplastic housing is reinforced with glass and conductive fibers for electrostatic dissipation and mechanical strength.\u003c\/li\u003e\n\u003cli\u003eEnvironmental protection rated at Type 4X and IP66 for demanding plant locations.\u003c\/li\u003e\n\u003cli\u003eSleeve and standoff design allows convenient external adjustment and access to the proximity probe without dismantling the machine casing.\u003c\/li\u003e\n\u003cli\u003eDouble NPT conduit entry fittings with stainless steel reducers for robust mechanical conduit connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eCommon industrial installations include shaft vibration and axial position measurements on rotating machinery such as steam turbines, gas turbines, centrifugal compressors, gearboxes, pumps, and fans. The unified construction is especially effective in locations where traditional proximity system installation space is limited or where minimizing external cabling is desired to improve mechanical protection.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-150-06-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm Standoff Adapter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e150 mm probe penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-150-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, 1-metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Linear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% under nominal conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (no barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 m of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing and Sensor Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (subject to hazardous area limitations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve and Retaining Chain\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve \u0026amp; Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe transducer assembly must be mounted on a flat surface using the 3\/4-14 NPT mounting thread (Option 02) which handles the physical engagement of the 40 mm standoff adapter. To avoid cross-talk, ensure the probe tips maintain a separation distance of at least 40 mm for axial position measurements and 38 mm for radial vibration measurements. Connect the field wiring using a 3-conductor twisted shielded cable with a drain wire (typically 1.0 mm2 or 18 AWG) between the internal terminal board and the associated monitor system. Shield grounding must be terminated at the monitor end, ensuring the shield remains isolated at the housing to prevent ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe unit complies with the European CE mark requirements, EMC Directive 2014\/30\/EU, and RoHS Directive 2011\/65\/EU. Additionally, the housing IP66 rating is verified by BASEEFA, and the Option BR configuration satisfies INMETRO hazardous area standards for intrinsic safety and non-incendive installations in Brazil.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666554646891,"sku":"330881-BR-04-150-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-150-06-02-proxpac-xl-housing-0b0adnjt2mb_23bbe603-9766-41d2-87ef-9a3e4035ae18.jpg?v=1765440614"},{"product_id":"bently-nevada-330881-br-04-145-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-145-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies a 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals integrated inside this metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly — \u003cstrong\u003e330881-BR-04-145-06-02\u003c\/strong\u003e. This configuration combines a non-contact eddy-current probe and a 3300 XL Proximitor sensor directly within a single glass-reinforced polyphenylene sulfide (PPS) housing. This integrated design removes the need for an external extension cable and separate Proximitor housing, allowing field wiring to connect directly from the monitor to the transducer assembly. This metric configuration is built with a 40 mm standoff adapter (Option 04) and a 145 mm probe penetration sleeve (Option 145), coupled with specific SST reducers and fittings (Option 06) and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThe PPS housing material replaces traditional metals, incorporating glass and conductive fibers to strengthen the assembly and dissipate electrostatic charges. Rated for Type 4X and IP66 environments, the housing protects the internal electrical components in severe environments. The internal probe consists of a 1-meter triaxial cable constructed with fluoroethylene propylene (FEP) insulation, terminating in a gold-plated ClickLoc connector. Integrating both probe and sensor together reduces installation steps and cabling costs on critical rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR provides an integrated 3300 XL 8 mm proximity probe with INMETRO (Brazil) hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04 specifies a 40 mm standoff adapter length (B Dimension).\u003c\/li\u003e\n  \u003cli\u003eOption 145 specifies a 145 mm probe penetration length (C Dimension) in the sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003eOption 06 includes a fittings kit consisting of one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread (required for standoff adapter configurations).\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing is glass and conductive fiber-reinforced to dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 environmental ratings provide protection against hose-directed water and environmental ingress.\u003c\/li\u003e\n  \u003cli\u003eTriaxial FEP-insulated 1-meter probe cable with a gold-plated ClickLoc connector connects probe to the integrated Proximitor sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in industrial rotating machinery such as gas turbines, steam turbines, centrifugal compressors, pumps, and fans where external probe adjustment is required but space or wiring runs do not permit separate Proximitor housings.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption Code\u003c\/th\u003e\n    \u003cth\u003eThis SKU Value\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e330881-BR-04-145-06-02\u003c\/td\u003e\n    \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n    \u003ctd\u003eBR\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) approvals\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n    \u003ctd\u003e04\u003c\/td\u003e\n    \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n    \u003ctd\u003e145\u003c\/td\u003e\n    \u003ctd\u003e145 mm probe penetration length (C Dimension)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n    \u003ctd\u003e06\u003c\/td\u003e\n    \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n    \u003ctd\u003e02\u003c\/td\u003e\n    \u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eValue\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n    \u003ctd\u003e330881-BR-04-145-06-02\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTransducer Type\u003c\/td\u003e\n    \u003ctd\u003ePROXPAC XL Proximity Transducer (Metric)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-meter cable length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePower Requirements\u003c\/td\u003e\n    \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLinear Range\u003c\/td\u003e\n    \u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNominal Scale Factor\u003c\/td\u003e\n    \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFrequency Response\u003c\/td\u003e\n    \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n    \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n    \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n    \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Cable\u003c\/td\u003e\n    \u003ctd\u003e1-meter length, 75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Connector\u003c\/td\u003e\n    \u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHousing Material\u003c\/td\u003e\n    \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOuter Sleeve Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRetaining Screws Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSleeve O-ring Material\u003c\/td\u003e\n    \u003ctd\u003eNeoprene\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eGrounding Liner \/ Retaining Plate\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n    \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLid Label Material\u003c\/td\u003e\n    \u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n    \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n    \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHousing Impact Strength\u003c\/td\u003e\n    \u003ctd\u003eCertified by BASEEFA to withstand two separate 4 Joule (5.4 ft-lb) impacts at -39 degC and at 115 degC; CSA verified to withstand 7 Joule (9.5 ft-lb) at room temperature\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Operating Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Housing \u0026amp; Proximitor Sensor Operating Temp\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHumidity Ingress Rating\u003c\/td\u003e\n    \u003ctd\u003e100% condensing, non-submersible (when connectors are protected); Housing is rated Type 4X and IP66\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eTerminal\u003c\/th\u003e\n    \u003cth\u003eFunction\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCOM\u003c\/td\u003e\n    \u003ctd\u003eCommon \/ Ground\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOUT\u003c\/td\u003e\n    \u003ctd\u003eSignal Output\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eVT\u003c\/td\u003e\n    \u003ctd\u003ePower Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe PROXPAC XL design seals differential pressure between the probe tip and the housing main body when used with a 3300 XL 8 mm probe.\u003c\/li\u003e\n  \u003cli\u003eEnsure sleeve assemblies with combined standoff and penetration dimensions greater than 305 mm (12.0 in) receive additional sleeve support near the probe tip to stiffen the assembly against resonance.\u003c\/li\u003e\n  \u003cli\u003eAdjust the threaded sleeve within the +\/-12.7 mm (0.5 in) allowable margin to establish the appropriate probe gap.\u003c\/li\u003e\n  \u003cli\u003eImplement correct grounding and shielding practices to prevent electrical interference from impacting signal quality.\u003c\/li\u003e\n  \u003cli\u003ePrevent ingress of external fluids and moisture by routing conduits with appropriate drip loops and sealing field entries properly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (EMC Directive 2014\/30\/EU; RoHS Directive 2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003eCSA\/NRTL\/C Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx Ex II 1 G Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc\u003c\/li\u003e\n  \u003cli\u003eINMETRO Approvals (Brazil) - Option BR\u003c\/li\u003e\n  \u003cli\u003eABS Marine Type Approval (2019 Rules for Conditions of Classification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666556612971,"sku":"330881-BR-04-145-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-145-06-02-housing-3uawjlii5jb_288fa69f-f671-45cb-a6aa-b9e47112a60e.jpg?v=1765440620"},{"product_id":"bently-nevada-330881-br-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-85-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazil) Multiple Approvals with an integrated 3300 XL 8 mm probe, while Option 04 and Option 85 provide a 40 mm standoff adapter and 85 mm probe penetration for this metric assembly — the \u003cstrong\u003e330881-BR-04-85-03-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis integrated design brings together the proximity probe, sleeve, and 3300 XL Proximitor sensor into a single, self-contained polymer housing. By eliminating the typical extension cable between probe and sensor, the assembly reduces field wiring complexity and simplifies installation on rotating machinery. The housing cover is molded from glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers, providing Type 4X and IP66 protection against harsh chemical and moisture environments. Field wiring runs directly from the integrated terminal connections to monitoring systems, removing the need for a separate Proximitor sensor enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption BR provides INMETRO (Brazil) hazardous area approvals for zone-rated environments.\u003c\/li\u003e\n\u003cli\u003eOption 04 includes a 40 mm metric stainless steel standoff adapter to match specific casing clearances.\u003c\/li\u003e\n\u003cli\u003eOption 85 defines a probe penetration sleeve length of 85 mm.\u003c\/li\u003e\n\u003cli\u003eOption 03 supplies a metric installation fitting kit with one M20 conduit fitting and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a standard 3\/4-14 NPT mounting thread for rigid mechanical attachment.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design combines a 3300 XL 8 mm probe and a 1-meter Proximitor sensor in one housing.\u003c\/li\u003e\n\u003cli\u003eGlass-reinforced polyphenylene sulfide (PPS) housing resists chemical degradation and dissipates electrostatic charges.\u003c\/li\u003e\n\u003cli\u003eDirect terminal-to-monitor field wiring eliminates intermediate extension cables and separate driver enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position monitoring on large industrial rotating assets.\u003c\/li\u003e\n\u003cli\u003eContinuous machinery protection in oil and gas, petrochemical, and power generation environments.\u003c\/li\u003e\n\u003cli\u003eEnvironments requiring strict compliance with Brazilian INMETRO hazardous area standards.\u003c\/li\u003e\n\u003cli\u003eWet, corrosive, or high-moisture installations where Type 4X and IP66 environmental protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO Multiple Approvals (Brazil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e85 mm Probe Penetration Option (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe (with 1-meter cable length installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-meter length, 75 Ohm triaxial, fluoroethylene propylene (FEP) insulated with gold-plated brass ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) over 0.25 mm to 2.30 mm range (-1 Vdc to -17 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal (plus\/minus 5% interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.025 mm (plus\/minus 1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in) for cross-talk under 50 mV; 76.2 mm (3.0 in) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Threads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Penetration Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eSignal Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-VT\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon Ground Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eVibration\/Position Output Signal (nominal 7.87 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct mechanical alignment of the outer sleeve assembly during insertion. The standoff adapter must be properly threaded and torqued to avoid loose mechanical coupling. Maintain a recommended gap setting of 1.27 mm (50 mils) between the probe tip and target shaft surface. Use 3-conductor shielded twisted-pair field wiring of 0.2 to 1.5 mm2 (16 to 24 AWG) to connect directly to the integrated Proximitor terminal block inside the housing cover. Route the wiring through M20 fittings while sealing any unused conduit entrances using the supplied blanking plugs to maintain the IP66 and Type 4X rating.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer is certified with INMETRO hazardous area approvals for zone-rated environments in Brazil. The outer housing holds an IP66 rating verified by BASEEFA and complies with the European CE mark requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666562838891,"sku":"330881-BR-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-85-03-02-housing-2lwukvzad1a_22e806b9-fd90-4c57-8279-2eb87e29d5ab.jpg?v=1765440687"},{"product_id":"bently-nevada-330880-16-15-020-02-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-15-020-02-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 16 (non-approved 8 mm probe), Option 15 (1.5-inch standoff adapter), and Option 020 (2.0-inch penetration) specify the 3300 XL configuration of this PROXPAC XL Proximity Transducer — \u003cstrong\u003e330880-16-15-020-02-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis design combines the 3300 XL 8 mm proximity probe and its associated Proximitor sensor inside a single, unified PPS housing assembly. By combining these components, it eliminates the need for an external extension cable between the probe and Proximitor, as well as the separate housing typically required. Standard field wiring connects directly from the monitor to the PROXPAC housing, simplifying installation in tight or harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated assembly contains a 3300 XL 8 mm proximity probe and its companion 1-metre Proximitor sensor directly in the housing lid.\u003c\/li\u003e\n\u003cli\u003eEquipped with a 1.5 in (38 mm) standoff adapter to adjust mounting depth and clear machine obstructions.\u003c\/li\u003e\n\u003cli\u003eProvides a 2.0 in (51 mm) probe penetration option through the machine casing.\u003c\/li\u003e\n\u003cli\u003eIncludes a fittings kit with two 3\/4-14 NPT conduit fittings and one blanking plug.\u003c\/li\u003e\n\u003cli\u003eUtilizes a robust 3\/4-14 NPT outer sleeve mounting thread to secure the assembly to the machine case.\u003c\/li\u003e\n\u003cli\u003eMolded polyphenylene sulfide (PPS) housing resists ultraviolet exposure and incorporates glass and conductive fibers to dissipate static charges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis integrated transducer assembly is ideal for machinery protection systems where space is constrained and a separate Proximitor housing cannot be accommodated. Common applications include shaft vibration and axial position monitoring on steam turbines, gas turbines, centrifugal compressors, and heavy industrial pumps.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-16-15-020-02-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer (English version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe and Approvals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter Length\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm) standoff adapter (B dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration Length\u003c\/td\u003e\n\u003ctd\u003e020\u003c\/td\u003e\n\u003ctd\u003e2.0 in (51 mm) probe penetration (C dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eTwo 3\/4-14 NPT fittings, one plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330880-16-15-020-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-metre length, 75 Ohm triaxial, FEP insulated with ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 degC (-62 to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 degC (-62 to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.2 mm (3.0 in) minimum (50.8 mm \/ 2.0 in absolute minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper electrical insulation and mechanical alignment, mount the assembly securely to the machine case using the 3\/4-14 NPT outer sleeve thread. Ground the housing liner using the internal ground plate. When running conduit, prevent water or moisture accumulation by utilizing the supplied 3\/4-14 NPT fittings kit and sealing the conduit entry paths appropriately.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL proximity transducer assembly meets the following mechanical and electrical standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCE marked (European Union electromagnetic compatibility directives)\u003c\/li\u003e\n\u003cli\u003eIP66 rating verified by BASEEFA\u003c\/li\u003e\n\u003cli\u003eType 4X enclosure rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666564870507,"sku":"330880-16-15-020-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-15-020-02-02-proxpac-xl-proximity-transducer-nw1lvcr4hnm_0ca0013a-291a-477b-93fd-7f6a4658ba8f.jpg?v=1765440719"},{"product_id":"bently-nevada-330180-x1-cn-mod-145004-82-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD 145004-82 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN MOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly specialized 3300 XL Proximitor Sensor engineered for precise machinery protection in the most demanding industrial environments. This specific configuration is tailored for the Chinese market, meeting stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEPSI\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSRRC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eregulatory requirements for hazardous area operation and electromagnetic compatibility. Unlike standard proximity sensors calibrated for 4140 steel, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is factory-calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Nickel-Chrome-Moly-Vanadium) target materials. This specialized calibration is critical for assets like high-pressure steam turbines or specialized compressors where exotic alloy shafts are utilized. By providing a linearized 7.87 V\/mm (200 mV\/mil) output against non-standard metallurgy, this sensor ensures the integrity of vibration and position data, preventing false trips or missed alerts in mission-critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Modification Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe technical complexity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its specific ordering options and hardware modifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1 Modification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates a custom hardware configuration featuring DIN rail mounting for high-density cabinet installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (China Specific Options):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEPSI certified for explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCCC mandatory safety certification and SRRC radio frequency approval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChina RoHS compliant with a 50-year environment-friendly use period (EFUP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD 145004-82:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates a factory modification to the Printed Wiring Assembly (PWA) and calibration process. This \"MOD\" replaces the standard 4140 steel working standard with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNi-Cr-Mo-V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etarget (Target CT # CT-0069), ensuring the 3300 XL system maintains its linear range across the specialized material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModification Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMOD 145004-82\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNi-Cr-Mo-V (Nickel-Chrome-Molybdenum-Vanadium)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 metre (Standard 3300 XL 5mm\/8mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 to 2.3 mm (10 to 90 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Zero\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-3.0 VDC @ 20 mils\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEPSI, CCC, SRRC, China RoHS (50 years)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the MOD 145004-82 required instead of a standard 330180?\u003c\/strong\u003eProximity sensors operate on eddy current principles, which are highly sensitive to target metallurgy. A standard sensor calibrated for 4140 steel will produce significant scale factor errors when measuring a Ni-Cr-Mo-V shaft. The MOD 145004-82 hardware is physically adjusted and calibrated to this specific alloy to ensure accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system length must be used with this Proximitor?\u003c\/strong\u003ePer the labeling information, this unit is designed for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0 metre\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. You must use a 3300 XL 5mm or 8mm probe and extension cable that combine for a total electrical length of 9.0 metres to maintain calibration integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the -CN suffix affect international compliance?\u003c\/strong\u003eThe -CN suffix ensures the device is legal for installation within the People's Republic of China, meeting local explosive safety (NEPSI) and mandatory certification (CCC) laws. It is functionally equivalent to global 3300 XL sensors but carries the required local labeling and documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Safety Maintenance\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, verify the shaft material metallurgy. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically for Ni-Cr-Mo-V. Using this sensor on 4140 steel or other alloys will result in incorrect vibration readings. Reference the job number (162282) and CT-0069 target code for your facility's asset records.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Zeroing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, set the probe gap to achieve the electrical zero of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-3.0 VDC @ 20 mils\u003c\/strong\u003e. This ensures the measurement stays within the optimized linear range of the 3300 XL system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the DIN rail is properly bonded to the instrument earth. While the Proximitor housing is designed for isolation, proper rack grounding is essential to maintain the CCC\/SRRC electromagnetic compatibility standards and prevent signal noise in high-frequency switching environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor NEPSI-certified installations, ensure all cable glands and conduit seals meet the local explosion-proof requirements. Modification of the PWA (as specified in BOM 145004) must only be performed by Bently Nevada factory-authorized service centers to maintain the safety rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666564903275,"sku":"330180-X1-CN MOD 1450004-82","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-cn-mod-1450004-82-proximity-transducer-system-cuh4jpwij4o_a8068a52-102a-4284-8dbf-327a8ca368db.jpg?v=1765440720"},{"product_id":"bently-nevada-330881-28-04-70-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-70-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (multiple approvals 3300 XL probe) and Option 03 (one M20 fitting) specify this metric PROXPAC XL configuration — \u003cstrong\u003e330881-28-04-70-03-02\u003c\/strong\u003e. This metric-threaded \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly is equipped with a 40 mm standoff adapter (Option 04), a 70 mm probe penetration length (Option 70), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\u003cp\u003eThis integrated assembly combines a 3300 XL 8 mm proximity probe and its associated 3300 XL Proximitor sensor directly into a single glass-reinforced polyphenylene sulfide (PPS) thermoplastic enclosure. By eliminating the necessity for a separate Proximitor sensor housing or an external extension cable, the 330881 system significantly simplifies industrial field installation, reduces wiring complexity, and forms a durable, self-contained eddy-current measurement system. The metric 330881 variant relies on metric conduit fittings (M20 or M25) and metric probe sleeve adjustments, distinguishing it from English-threaded 330880 models.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 probe and approvals: Integrates a 3300 XL 8 mm proximity probe certified with multiple hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04 standoff: Features a 40 mm standoff adapter to adjust probe positioning.\u003c\/li\u003e\n  \u003cli\u003eOption 70 penetration: Provides a 70 mm probe penetration depth.\u003c\/li\u003e\n  \u003cli\u003eOption 03 conduit fitting: Includes one M20 conduit fitting and two blanking plugs for secure cable routing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread: Uses a standard 3\/4-14 NPT mounting thread for standoff adapter engagement.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor: Houses a 1-metre 3300 XL Proximitor sensor directly in the housing lid, eliminating separate extension cables.\u003c\/li\u003e\n  \u003cli\u003eAdvanced PPS housing: Molded glass-reinforced polyphenylene sulfide housing provides chemical resistance and static dissipation.\u003c\/li\u003e\n  \u003cli\u003eHigh environmental protection: Enclosure is rated for Type 4X and IP66 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUsed for non-contact shaft vibration and axial position measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eIdeal for severe industrial environments including oil and gas facilities, petrochemical plants, and power generation turbines.\u003c\/li\u003e\n  \u003cli\u003eSimplifies installation in locations where mounting separate Proximitor sensors in external enclosures is impractical or costly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-04-70-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003e70 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-70-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMetric Integrated Proximity Transducer Assembly (PROXPAC XL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length (Option 28, multiple approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from DSL\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB) with up to 305 metres of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) with conductive fibers (UV resistant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Metal Parts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 and AISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-ring Seals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene (sleeve-to-housing), Viton (probe tip-to-case pressure seal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eField wiring connects directly inside the PROXPAC XL enclosure to the integrated terminal block, eliminating the need for an external extension cable. Terminal block interface specifications:\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Symbol\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eRecommended Connection\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003eField wiring power lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eTransducer Signal Output\u003c\/td\u003e\n      \u003ctd\u003eField wiring signal lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Signal Ground\u003c\/td\u003e\n      \u003ctd\u003eField wiring common lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n  \u003cli\u003eWire Size Compatibility: 0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/li\u003e\n  \u003cli\u003eRecommended Cable: 3-conductor twisted shielded cable with drain wire\u003c\/li\u003e\n  \u003cli\u003eMaximum Distance: Up to 305 metres (1000 feet) to the monitoring system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMounting: Mount the assembly via the 3\/4-14 NPT outer thread (Option 02) onto the machine casing. Use the standoff adapter to adjust the probe positioning relative to the target surface.\u003c\/li\u003e\n  \u003cli\u003eProbe Gap: Set the initial probe gap to approximately 1.27 mm (50 mils) corresponding to -10.0 Vdc output at the center of the linear range.\u003c\/li\u003e\n  \u003cli\u003eSleeve Adjustment: The threaded sleeve allows +\/-12.7 mm (+\/-0.5 in) of adjustment to achieve the correct gap during installation.\u003c\/li\u003e\n  \u003cli\u003eCondensation Control: Seal all conduit entries with the provided blanking plugs or conduit fittings. Ensure that field wiring cables loop downward before entering the enclosure to prevent moisture from running into the housing through the conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark: Complies with European CE directives.\u003c\/li\u003e\n  \u003cli\u003eIP Rating: IP66 and Type 4X rating verified for environmental seal.\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals: Option 28 probe is certified with multiple international hazardous area agency approvals (including ATEX, IECEx, and CSA) for intrinsically safe installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565067115,"sku":"330881-28-04-70-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-70-03-02-proxpac-xl-proximity-transducer-ywk4qcs55ly_eef74032-749d-43f5-8be0-955f13974bb1.jpg?v=1765440724"},{"product_id":"bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor","title":"Bently Nevada 330780-51-05 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 51 (5.0 meter system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 11 mm Proximitor Sensor configuration — \u003cstrong\u003e330780-51-05\u003c\/strong\u003e. The 3300 XL 11 mm system features an incremental scale factor of 3.94 V\/mm (100 mV\/mil) for non-contact displacement and vibration measurements. The system is used on fluid-film bearing machines where an extended linear range is required, including turbine axial (thrust) position, ramp differential expansion, and reciprocating compressor rod drop monitoring.\u003c\/p\u003e\n\u003cp\u003eThis 330780-51-05 sensor processes the RF signal from a compatible 3300 XL 11 mm proximity probe and extension cable, outputting a voltage signal proportional to the distance between the probe tip and the observed shaft surface. The unit mounts on standard 35 mm DIN rails and is compatible with 3500 series machinery protection systems and secondary monitors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 51 specifies a 5.0 meter (16.4 feet) system length combined with an integrated DIN-mount physical layout.\u003c\/li\u003e\n  \u003cli\u003eOption 05 delivers multiple international hazardous area agency approvals including ATEX, IECEx, and CSA.\u003c\/li\u003e\n  \u003cli\u003eGenerates a linear range of 4.0 mm (160 mils) for reliable tracking of larger rotor and shaft movements.\u003c\/li\u003e\n  \u003cli\u003eProvides an output scale factor of 3.94 V\/mm (100 mV\/mil) with high accuracy and low thermal drift.\u003c\/li\u003e\n  \u003cli\u003eEncased in an A380 aluminum housing for high mechanical integrity and environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is used in rotating machinery monitoring where an extended linear range is required. Typical application areas include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine axial (thrust) position and ramp differential expansion tracking\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod position and rod drop measurements\u003c\/li\u003e\n  \u003cli\u003eHigh-speed industrial turbine and compressor shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eTachometer, phase reference (Keyphasor), and zero speed signal generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor is configured using the following structured options:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e51\u003c\/td\u003e\n      \u003ctd\u003e5.0 meter (16.4 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330780-51-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Requirement\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Length Compatibility\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003eTested to IEC 68-2-3 damp heat\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Blocks Torque Limit\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Weight\u003c\/td\u003e\n      \u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Dimensions (Option 51)\u003c\/td\u003e\n      \u003ctd\u003e31.7 mm x 70.8 mm x 89.4 mm (1.25 in x 2.79 in x 3.52 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT\u003c\/td\u003e\n      \u003ctd\u003ePower Supply input\u003c\/td\u003e\n      \u003ctd\u003eNegative voltage supply (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eSystem common reference ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eProportional dynamic voltage output (3.94 V\/mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation ensures stable, noise-free vibration and position data. Observe the following guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount on a standard 35 mm DIN rail. Ensure a physical clearance of at least 3.05 mm (0.12 in) is maintained above and below the mounting pad to allow easy removal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect using 0.2 to 1.5 mm2 (16 to 24 AWG) shielded three-conductor triad field wiring. Keep field wiring length under 305 meters (1000 feet) to prevent high-frequency signal attenuation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper shield terminal grounding at the monitor side only. Do not double-ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e If terminals are exposed to direct moisture or dust, the Proximitor must be installed within a protective enclosure providing at least IP54 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330780-51-05 Proximitor Sensor has option 05 approvals, which verify compliance with multiple standard requirements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically Safe (Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc) and Non-Sparking\/Ec (Ex nA\/ec IIC T5...T1 Gc)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American (cNRTLus):\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Div 1, Groups A, B, C, D; Class I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions), CE compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 compliant (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with European Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565525867,"sku":"330780-51-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330780-51-05-3300-xl-11-mm-proximitor-sensor-dsdxsfliceq_4954eac2-4609-4073-b5a1-d5d247fbadeb.jpg?v=1765440728"},{"product_id":"bently-nevada-330180-x1-05mod-145347-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-05MOD:145347-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330180-X1-05MOD:145347-05\u003c\/strong\u003e specifies this customized 3300 XL \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e configuration, featuring the X1 DIN-rail mount modification, standard Agency Approval Option 05, and a specialized target material calibration under Modification 145347 (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis customized Proximitor sensor is calibrated as part of a specialized modification chain to ensure precise shaft vibration and axial position tracking when paired with 3300 XL 5 mm or 8 mm proximity probes and 9-meter extension cables. By departing from standard AISI 4140 steel calibration, this sensor corrects for the specific electrical conductivity and magnetic permeability of alternative rotor metallurgy, delivering a linear voltage output in critical turbomachinery applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN-Rail Mounting (X1 Option): Pre-configured with a secure mounting clip for direct installation onto standard 35 mm DIN rails, simplifying panel wiring.\u003c\/li\u003e\n  \u003cli\u003eMultiple Agency Approvals (Option 05): Certified for safe operation in hazardous industrial environments under ATEX, IECEx, and CSA standards.\u003c\/li\u003e\n  \u003cli\u003eCustom Target Calibration (Mod 145347-05): Adjusted circuit parameters to maintain scale factor accuracy over non-standard metallic targets.\u003c\/li\u003e\n  \u003cli\u003eSystem Integration: Houses the stable high-frequency oscillator and demodulator circuitry necessary to drive Bently Nevada eddy-current probes.\u003c\/li\u003e\n  \u003cli\u003eExcellent Noise Immunity: Designed with shielding and filtering that isolate the sensor output from electromagnetic and radio-frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe sensor is ideal for turbomachinery monitoring in heavy-industry sectors such as oil and gas, petrochemicals, power generation, and water treatment. It is specifically applied where machinery shafts are composed of non-standard alloys rather than AISI 4140 steel, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine rotor displacement measurement\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor radial shaft vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eHigh-speed motor and pump axial thrust tracking\u003c\/li\u003e\n  \u003cli\u003eGearbox input and output shaft vibration diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment Code\u003c\/th\u003e\n      \u003cth\u003eThis SKU Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5mm\/8mm 9m Recalibrated Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment A: Total Length and Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eX1\u003c\/td\u003e\n      \u003ctd\u003eModification, DIN Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment B: Agency Approval and Mod Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05MOD:145347\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx) with custom recalibration modification family 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment C: Target Material Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eOption 05 target material calibration under Modification 145347\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330180-X1-05MOD:145347-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDevice Type\u003c\/td\u003e\n      \u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 5 mm \/ 8 mm (9-Meter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Configuration\u003c\/td\u003e\n      \u003ctd\u003eDIN-rail mount (X1 option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eOption 05 (Multiple Approvals: CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 90 mils (0.25 to 2.25 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Zero (E-zero)\u003c\/td\u003e\n      \u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-51 to 100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.2 mm x 104.1 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the Proximitor sensor is mounted in a dry, clean enclosure or weather-proof housing to prevent moisture ingress. Maintain proper DIN rail grounding to protect signal integrity. Secure probe and extension cable coaxial connections with connector protectors or self-coalescing tape to insulate them from structural ground paths. Shielded field wiring must run back to the monitoring system to eliminate electromagnetic coupling.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eWhen ordered with Option 05, this device is certified for installation in hazardous locations under multiple international schemes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA: Intrinsically Safe (Class I, Div 1, Groups A, B, C, D) and Non-Incendive (Class I, Div 2)\u003c\/li\u003e\n  \u003cli\u003eATEX \/ IECEx: Ex ia IIC T4 Ga (Zone 0) and Ex nA IIC T4 Gc (Zone 2)\u003c\/li\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565722475,"sku":"330180-X1-05 MOD：145347-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145347-05-proximitor-sensor-sxketajhwsi_93f19dd0-0daa-4f7c-9dd2-163af19d0e56.jpg?v=1765440733"},{"product_id":"bently-nevada-330881-16-00-395-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-00-395-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-16-00-395-06-02\u003c\/strong\u003e specifies a metric Bently Nevada PROXPAC XL integrated proximity transducer configuration, pairing a 3300 XL 8 mm proximity probe (Option 16) with a 395 mm probe penetration depth (Option 395). This self-contained, integrated assembly incorporates its own 3300 XL Proximitor sensor inside the housing lid, eliminating the need for an intermediate extension cable or a separate Proximitor enclosure. Field wiring connects directly between the monitors and the terminal strip inside the housing, reducing installation complexity and wiring interfaces.\u003c\/p\u003e\n\u003cp\u003eThis configuration operates without an external standoff adapter (Option 00) and features a 3\/4-14 NPT mounting thread (Option 02). It is supplied with a fittings kit (Option 06) containing one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs. The housing is constructed of glass-reinforced, conductive-fiber-filled polyphenylene sulfide (PPS) thermoplastic, which resists chemical exposure, provides IP66 and Type 4X sealing, and dissipates electrostatic charges. Because this unit is ordered with Option 16, it is supplied without hazardous area agency approvals.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 16 integrates a 3300 XL 8 mm proximity probe without hazardous area approvals.\u003c\/li\u003e\n\u003cli\u003eOption 00 configures the transducer assembly without an external standoff adapter.\u003c\/li\u003e\n\u003cli\u003eOption 395 provides a deep 395 mm probe penetration length for machinery cases.\u003c\/li\u003e\n\u003cli\u003eOption 06 includes a metric\/NPT fittings kit with one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design locates the Proximitor sensor in the housing lid, eliminating remote sensor enclosures and separate extension cables.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) housing material offers chemical resistance and resists electrostatic charge accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurement on industrial rotating machinery.\u003c\/li\u003e\n\u003cli\u003eDirect-mount external casing probe installations where separate Proximitor housings are impractical.\u003c\/li\u003e\n\u003cli\u003eSevere-environment machinery monitoring requiring IP66 and Type 4X environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330881-16-00-395-06-02 represents a specific orderable configuration of the metric PROXPAC XL Proximity Transducer Assembly. The table below decodes each option segment of this SKU:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e395\u003c\/td\u003e\n\u003ctd\u003e395 mm penetration length (increments of 1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread (required if ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Category\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n\u003ctd\u003e330881-16-00-395-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Family\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), beginning at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% under standard conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/- 0.025 mm (+\/- 1 mil) over the linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X (hose-directed water seal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve \u0026amp; Retaining Chain Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing \u0026amp; Proximitor Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the target shaft or surface meets the minimum target diameter of 15.2 mm (0.6 in) to achieve full linear calibration.\u003c\/li\u003e\n\u003cli\u003eTo prevent measurement cross-talk, maintain a minimum separation of 40 mm (1.6 in) for axial position measurements and 38 mm (1.5 in) for radial vibration measurements.\u003c\/li\u003e\n\u003cli\u003eDo not expose the probe to temperatures below -34 degC (-29 degF) during operation to avoid premature failure of the pressure seal.\u003c\/li\u003e\n\u003cli\u003eTorque the probe sleeve locknut to 39.3 N-m (350 in-lb) and the housing retaining nut to 29.5 N-m (260 in-lb) during final physical mounting.\u003c\/li\u003e\n\u003cli\u003eSeal all conduit entries and utilize the supplied fittings (Option 06) to prevent moisture or condensation from traveling through the conduit into the housing cavity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with European CE mark.\u003c\/li\u003e\n\u003cli\u003eHousing IP66 rating verified by BASEEFA report number T07\/0709.\u003c\/li\u003e\n\u003cli\u003eNote: Because this specific assembly is configured with Option 16, it does not come with hazardous area agency approvals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566213995,"sku":"330881-16-00-395-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-16-00-395-06-02-proxpac-xl-proximity-transducer-c1okvqdzaiy_4ea0eb10-7b60-47e2-9295-845d1b192431.jpg?v=1765440743"},{"product_id":"bently-nevada-330881-br-04-034-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-034-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazilian) approvals and a 3300 XL 8 mm probe configuration for this metric PROXPAC XL integrated transducer assembly — \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e. This configuration integrates a metric PROXPAC XL housing, a 40 mm standoff adapter (Option 04), and a custom 34 mm probe penetration length (Option 034). The assembly features a heavy-duty sealing kit under Option 06, which provides one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs. The entire unit is designed to mount via a 3\/4-14 NPT thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eBy housing both a 1-metre 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor within a single self-contained housing, the \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e eliminates the need for external extension cables and standalone Proximitor housings. This design directly reduces connection points, minimizes signal degradation, and simplifies wiring layouts by bringing field connections directly to the monitor. The housing is constructed from Polyphenylene Sulfide (PPS) molded thermoplastic reinforced with glass and conductive fibers, which provides Type 4X and IP66 environmental protection while safely dissipating electrostatic charges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR: Features an integrated 3300 XL 8 mm proximity probe certified with INMETRO (Brazilian) hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04: Features a metric standoff adapter with a specific length of 40 mm.\u003c\/li\u003e\n  \u003cli\u003eOption 034: Configured with a precise 34 mm probe penetration length.\u003c\/li\u003e\n  \u003cli\u003eOption 06: Includes one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs to secure the conduit interface.\u003c\/li\u003e\n  \u003cli\u003eOption 02: Standard 3\/4-14 NPT mounting thread configuration, required to support standoff adapter options.\u003c\/li\u003e\n  \u003cli\u003eConductive PPS Housing: Thermoplastic material design provides defense against corrosive chemical environments and dissipates static charges.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Architecture: Built-in Proximitor sensor eliminates the traditional probe-to-sensor extension cable for a more direct signal path.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 Enclosure: Rated for direct hose-directed water exposure and harsh industrial locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDynamic shaft vibration monitoring on critical rotating machinery\u003c\/li\u003e\n  \u003cli\u003eRotor axial position and thrust movement measurement\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor piston rod position and rod runout wear monitoring\u003c\/li\u003e\n  \u003cli\u003eShaft radial displacement and casing thermal expansion detection\u003c\/li\u003e\n  \u003cli\u003eApplications in petrochemical, refining, and power generation facilities requiring INMETRO hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazilian) Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e034\u003c\/td\u003e\n      \u003ctd\u003e34 mm probe penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils); begins at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc to -17 Vdc nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 305 m (1,000 ft) between sensor and monitor using recommended 1.0 mm2 (18 AWG) 3-conductor shielded triax cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS) molded thermoplastic with glass and conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAdhering to these guidelines helps prevent common installation issues and maintains system integrity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the 3\/4-14 NPT mounting threads are free of debris and properly matched before threading the standoff adapter into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eEnsure the 8 mm probe tip maintains the recommended 1.27 mm (50 mils) gap to the target shaft for optimal linear range response.\u003c\/li\u003e\n  \u003cli\u003eRoute field wiring directly through the Option 06 fittings into the housing terminal block, securing the lid and lid screws to protect the internal Proximitor sensor from moisture and dust.\u003c\/li\u003e\n  \u003cli\u003eConfirm that the PPS housing's conductive fibers are grounded to allow effective dissipation of static electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eINMETRO Certifications: Intrinsically Safe (Ex ia IIC T4\/T5 Ga) and Non-sparking\/Increased safety (Ex nA\/Ex ec IIC T4\/T5 Gc) under Option BR.\u003c\/li\u003e\n  \u003cli\u003eEMC Directive: EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: Compliant with European Union Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eMaritime Standards: Certified under major classification rules where applicable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566312299,"sku":"330881-BR-04-034-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-034-06-02-proxpac-xl-housing-5cr2o3zuqsg_8f42fd74-247b-49be-aa0f-7106e471e2a6.jpg?v=1765440745"},{"product_id":"bently-nevada-330881-28-6-155-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-6-155-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals), Option 6 (60 mm standoff adapter), Option 155 (155 mm probe penetration), Option 03 (one M20 fitting, two plugs), and Option 02 (3\/4-14 NPT mounting thread) specify this integrated metric proximity transducer configuration — \u003cstrong\u003e330881-28-6-155-03-02\u003c\/strong\u003e. The \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly functions as a completely self-contained proximity probe system, integrating both a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor directly into a single molded thermoplastic housing. This integration removes the need for an external extension cable between the probe and Proximitor sensor, allowing field wiring to connect directly from the monitoring system to the assembly cover terminals.\u003c\/p\u003e\n\n\u003cp\u003eUnlike non-approved configurations or English thread variants such as the 330880 series, the 330881-28-6-155-03-02 configuration features a metric-focused layout with a 3\/4-14 NPT mounting thread required for its 60 mm standoff adapter. The integrated housing cover contains a Proximitor sensor with multiple international approvals, meeting intrinsically safe and non-incendive parameters for hazardous areas. The body is molded from ultraviolet-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers to dissipate electrostatic charges, providing a Type 4X and IP66 rating for severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 28 integration includes a 3300 XL 8 mm proximity probe with Multiple Approvals.\u003c\/li\u003e\n\u003cli\u003eOption 6 provides a 60 mm standoff adapter for mounting adjustment.\u003c\/li\u003e\n\u003cli\u003eOption 155 specifies a 155 mm metric probe penetration length.\u003c\/li\u003e\n\u003cli\u003eOption 03 supplies one M20 conduit fitting and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a 3\/4-14 NPT mounting thread, required when using the standoff adapter.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design contains both the probe and Proximitor sensor in one housing, eliminating separate extension cabling.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing is glass-reinforced and conductive-fiber filled to withstand harsh chemical contact and electrostatic buildup.\u003c\/li\u003e\n\u003cli\u003eIP66 and Type 4X environmental ratings seal against dust and hose-directed water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-6-155-03-02 is used for rotating machinery protection, particularly where space constraints or harsh outdoor conditions make running long extension cables impractical. Typical applications include shaft vibration and axial position measurements on steam turbines, gas turbines, compressors, pumps, and gearboxes in power generation, chemical processing, and oil and gas facilities. It is suitable for hazardous environments where intrinsically safe or non-incendive certifications are required.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-6-155-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e60 mm Standoff Adapter length (order in increments of 10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e155 mm Probe Penetration length (order in increments of 1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-28-6-155-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe with 1-metre cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (from 0.25 to 2.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% over 80 mil linear range (0 degC to +45 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Diameter Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in) minimum; 76.2 mm (3.0 in) recommended minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel with retaining chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe integrated design of the PROXPAC XL series simplifies wiring. Field wiring connections must be routed through the conduit entry. Utilize the supplied M20 fitting (Option 03) to maintain proper housing seals. Field wire size of 0.2 to 1.5 mm2 (16 to 24 AWG) is recommended, using a 3-conductor shielded triaxial cable. For grounding, ensure the internal grounding liner is securely connected, and route the drain wire according to the system's wiring layout. Take proper precautions to prevent moisture ingress through the conduit into the PPS housing.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-6-155-03-02 features multiple international hazardous area certifications (Option A = 28):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; Class III. Non-incendive Class I, Division 2, Groups A, B, C, and D; Class I, Zone 2: AEx\/Ex nA\/ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically safe II 1 G Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc. Non-sparking\/ec II 3 G Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European electromagnetic compatibility and electrical safety directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Enclosure certified for IP66 and Type 4X.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566476139,"sku":"330881-28-6-155-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-6-155-03-02-proxpac-xl-housing-g2y0go4m5tf_0d98e7f6-174e-48c6-9994-12720d6ec05b.jpg?v=1765440750"},{"product_id":"bently-nevada-330881-16-00-060-01-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-00-060-01-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-16-00-060-01-02\u003c\/strong\u003e specifies a metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration engineered with a 3300 XL 8 mm probe without hazardous area approvals (Option 16). This specific transducer assembly eliminates the standoff adapter (Option 00) and is optimized with a 60 mm probe penetration sleeve (Option 060), a metric Fittings kit containing one M25 fitting and two plugs (Option 01), and a 3\/4-14 NPT mounting thread (Option 02). By integrating both the proximity probe and the Proximitor sensor into a single, advanced Polyphenylene Sulfide (PPS) housing, this self-contained design simplifies field installations and eliminates the need for separate extension cables and dedicated Proximitor enclosures.\u003c\/p\u003e\n\n\u003cp\u003eUnlike hazardous-area configurations utilizing Option 28 (which includes multiple safety certifications), this Option 16 model is designed specifically for general-purpose, non-hazardous industrial environments, offering a cost-effective solution for safe-area machinery monitoring. The 60 mm penetration sleeve length provides a compact casing reach ideal for shallow-to-medium machinery housing depth configurations, while the M25 metric fittings and 3\/4-14 NPT thread allow rigid, environmentally sealed connections directly to the machine casing and standard conduit networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Enclosure Design:\u003c\/strong\u003e Houses both the 3300 XL 8 mm probe and the Proximitor sensor inside a single cover, removing intermediate cabling and reducing field wiring connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 16 Probe System:\u003c\/strong\u003e Incorporates a standard-performance 3300 XL 8 mm proximity probe configured for safe, non-hazardous areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e60 mm Metric Penetration (Option 060):\u003c\/strong\u003e Medium sleeve penetration length allows precise gapping and protective isolation of the probe case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo Standoff Adapter (Option 00):\u003c\/strong\u003e Configured for direct casing mount without standoff clearance requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOne M25 Fitting Kit (Option 01):\u003c\/strong\u003e Includes one metric M25 cable conduit fitting and two blanking plugs for reliable environmental sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged PPS Housing:\u003c\/strong\u003e Glass-reinforced, conductive-fiber-filled Polyphenylene Sulfide thermoplastic enclosure provides excellent structural integrity, dissipates electrostatic charges, and resists corrosive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP66 and Type 4X Rating:\u003c\/strong\u003e Certified to seal effectively against ingress from dust and high-pressure hose-directed water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical applications include radial shaft vibration, axial position, and speed measurements on rotating machinery situated in non-hazardous plant sections. This transducer is widely used on industrial pumps, fans, compressors, small steam turbines, and blowers where physical space constraints prevent the installation of separate, external Proximitor housing boxes.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-16-00-060-01-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eOne M25 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe (1-metre length) installed in sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), begins at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced, UV-resistant, conductive-fiber-filled Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor and Housing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when properly sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting Check:\u003c\/strong\u003e Verify the target gap is set to approximately 1.27 mm (50 mils), corresponding to an output voltage of -10.0 Vdc, to align measurements in the center of the linear calibration band.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Support Rule:\u003c\/strong\u003e If the total length of the sleeve exceeds 305 mm (12 in), additional physical supports or clamping should be used close to the probe head to prevent mechanical resonance and ensure probe stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Ingress Prevention:\u003c\/strong\u003e Ensure that all cover gaskets, plug threads, and conduit entries are fully sealed. Users must take adequate steps to prevent condensation from traveling down conduit lines into the housing terminal area.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Specifications:\u003c\/strong\u003e Utilize 0.2 to 1.5 mm2 (16 to 24 AWG) 3-conductor shielded triaxial cable. Keep the run distance below 305 m (1000 ft) to preserve full dynamic frequency response.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European EMC Directive 2014\/30\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Verification:\u003c\/strong\u003e IP66 verified by BASEEFA under report T07\/0709\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating:\u003c\/strong\u003e This Option 16 configuration does not carry hazardous-area certification. Designed for safe areas only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666567852395,"sku":"330881-16-00-060-01-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-16-00-060-01-02-proxpac-xl-proximity-transducer-mnnqimf34nk_201f95be-065e-4589-9ad4-1c39dd6d0845.jpg?v=1765440779"},{"product_id":"bently-nevada-330878-91-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-91-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 91 (9.0 meters system length, DIN mount) and Option 05 (Multiple Approvals) specify this 3300 XL 50 mm Proximitor Sensor configuration — \u003cstrong\u003e330878-91-05\u003c\/strong\u003e. This unit works with a 3300 XL 50 mm proximity probe and extension cable as part of a complete non-contact eddy-current displacement measurement system. It is used for shaft vibration and axial position measurement on large turbine rotors and machinery with oversized targets where displacement ranges exceed standard limits.\u003c\/p\u003e\n\u003cp\u003eUnlike variants configured for panel mounting (such as Option 90) or shorter 5.0-meter system lengths (such as Option 51), this specific configuration is tailored for DIN rail installation with a total system length of 9.0 meters. The integrated SpringLoc terminal strips facilitate fast field wiring connections without requiring specialized tools. Improved radio frequency interference (RFI) and electromagnetic interference (EMI) immunity allow this sensor to meet CE marking standards without specialized shield housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 91 specifies a 9.0-meter system calibration designed for DIN rail mounting configurations.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides multiple agency approvals including ATEX, IECEx, and CSA hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003eExtended linear range of 27.9 mm (1100 mils) starting at 1.3 mm (50 mils) from the target.\u003c\/li\u003e\n  \u003cli\u003eAverage Scale Factor (ASF) of 394 mV\/mm (10 mV\/mil) nominal for high-displacement environments.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal strips simplify connection procedures and resist loosening under vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in test points allow signal verification using standard instruments without interrupting field wiring.\u003c\/li\u003e\n  \u003cli\u003eBackward compatibility with standard 3300 XL 50 mm proximity probes and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine generator set differential expansion (DE) monitoring\u003c\/li\u003e\n  \u003cli\u003eLarge industrial gas turbine rotor position measurements\u003c\/li\u003e\n  \u003cli\u003eAxial displacement monitoring on oversized shaft assemblies\u003c\/li\u003e\n  \u003cli\u003eHigh-displacement target tracking in power generation and petrochemical facilities\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery with heavy vibration and environmental exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330878-91-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor, DIN mount, 9.0 m system length, multiple approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e91\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, DIN mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-91-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers), 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils), from approximately 1.3 mm to 29.2 mm (50 to 1150 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils) within 0 degC to +45 degC range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpringLoc terminal strip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupported Field Wiring Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eProximitor voltage output signal (dynamic and DC gap)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon circuit return reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e-VT\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDIN rail mounting utilizes the integrated DIN pad designed for a standard 35 mm DIN rail. Allow an additional 3.05 mm of clearance to remove the module from the rail.\u003c\/li\u003e\n  \u003cli\u003eGround the shield of the extension cable at the Proximitor Sensor housing. Do not ground the coaxial shield at any other point to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eUse recommended three-conductor shielded triad field cable (18 AWG or similar) for runs from the Proximitor Sensor to the monitor rack.\u003c\/li\u003e\n  \u003cli\u003eMaintain minimum target size requirements of 102 mm (4.0 inches) flat target diameter when verifying system calibration.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the probe gap using the physical movement of a sliding bracket or spindle micrometer prior to locking the case threads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc (Option 05)\u003c\/li\u003e\n  \u003cli\u003eCSA\/CNRTLus: Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eEuropean CE Mark: Compliant with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eElectromagnetic Compatibility Standards: EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n  \u003cli\u003eChina RoHS: 15-year Environment Friendly Use Period (EFUP)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666570998123,"sku":"330878-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-91-05-proximitor-sensor-p4h5thnndfr_6157fe43-0bed-4238-a4c9-e944da3ab6b9.jpg?v=1765440837"},{"product_id":"bently-nevada-330881-28-20-040-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-20-040-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-20-040-03-02\u003c\/strong\u003e: Metric \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e assembly featuring a 3300 XL 8 mm proximity probe with Multiple Approvals, a 200 mm standoff adapter, a 40 mm probe penetration depth, a single M20 fitting option, and a 3\/4-14 NPT mounting thread.\u003c\/p\u003e\n\u003cp\u003eThis integrated design combines the transducer probe and the 3300 XL Proximitor sensor into a single Polyphenylene Sulfide (PPS) thermoplastic housing. By housing the Proximitor directly at the measurement point, this assembly eliminates the need for a separate extension cable and external Proximitor enclosure, allowing field wiring to connect directly from the machinery monitor. The PPS plastic housing is glass- and conductive-fiber-reinforced to provide electrostatic charge dissipation and is rated for Type 4X and IP66 severe environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 integrates a 3300 XL 8 mm proximity probe with multiple international hazardous area certifications (CSA, ATEX, IECEx).\u003c\/li\u003e\n  \u003cli\u003eOption 20 provides a 200 mm standoff adapter constructed of stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 040 defines a 40 mm probe penetration depth for insertion into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eOption 03 includes a single M20 fitting kit with two blanking plugs to seal unused conduit entries.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a 3\/4-14 NPT mounting thread, which is required for the standoff adapter installation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor design removes the need for high-frequency coaxial extension cables, reducing installation labor.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene Sulfide (PPS) housing construction offers high impact strength and resistance to corrosive process fluids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL assembly is used for non-contact shaft vibration and axial position measurements on rotating machinery such as steam turbines, gas turbines, compressors, pumps, and gearboxes. It is suitable for applications where space is limited, hazardous area certifications are required, or where eliminating separate extension cables and external Proximitor housings reduces overall installation complexity and maintenance overhead.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-20-040-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA: Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB: Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e200 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC: Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e40 mm probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD: Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE: Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-20-040-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 +\/- 0.50 Ohm (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG). Supports up to 305 metres (1,000 feet) between Proximitor and monitor. Standard 3-conductor shielded triax recommended.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (0.25 mm to 2.3 mm; approx -1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over the linear range from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres (1,000 feet) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case \u0026amp; Sleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing IP \/ Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66 rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding continuity through the internal grounding liner and retaining plate. Run field wiring with high-quality 3-conductor shielded cable and tie down the drain wire appropriately.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Set the initial probe gap to the recommended 1.27 mm (50 mils) to center the measurement within the linear range of -1 Vdc to -17 Vdc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten the retaining nut to 29.5 N-m (260 in-lb). Torque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain secure placement and casing seals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Bracing:\u003c\/strong\u003e Since the combined standoff (\"B\" dimension) and penetration (\"C\" dimension) lengths total 240 mm, ensure the probe sleeve is properly supported if subjected to heavy system vibration or if adjacent piping exerts physical resonance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Control:\u003c\/strong\u003e Seal all unused electrical entries on the PPS housing using the supplied blanking plugs. Ensure that conduit paths do not carry moisture from the exterior environment into the terminal box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European EMC Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4 standards).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 28):\u003c\/strong\u003e Certified for intrinsically safe and non-incendive installations under CSA (Class I, Div 1 \u0026amp; 2, Groups A, B, C, D) and ATEX\/IECEx (Ex ia IIC T5...T1 Ga, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine Certifications:\u003c\/strong\u003e Approved in accordance with standard rules for offshore structures and marine conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572341611,"sku":"330881-28-20-040-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-20-040-03-02-sensor-proximity-tftx4sgmviu_bb5b16bf-f42a-49f2-af12-6d0743080571.jpg?v=1765440862"},{"product_id":"bently-nevada-330881-28-09-080-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-09-080-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-09-080-03-02\u003c\/strong\u003e: Metric PROXPAC XL Proximity Transducer featuring a 3300 XL 8 mm probe with multiple hazardous area approvals (Option 28), a 90 mm standoff adapter (Option 09), an 80 mm probe penetration length (Option 080), M20 fitting options (Option 03), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThis self-contained proximity transducer assembly combines the proximity probe and the 3300 XL Proximitor sensor into a single, unified housing. By mounting the Proximitor sensor directly in the housing lid, the system eliminates the need for external extension cables and separate Proximitor enclosures, greatly simplifying field wiring and installation in tight machinery spaces. The rugged housing is constructed from advanced polyphenylene sulfide (PPS) thermoplastic reinforced with glass and conductive fibers to withstand severe environmental exposure while dissipating electrostatic charges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3300 XL 8 mm Probe with Multiple Approvals (Option 28)\u003c\/strong\u003e provides trusted eddy-current displacement measurements with global hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e90 mm Standoff Adapter (Option 09)\u003c\/strong\u003e provides the precise spacing required to position the probe body in your machinery case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e80 mm Probe Penetration (Option 080)\u003c\/strong\u003e allows proper sleeve depth configuration for optimal mechanical clearance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle M20 Conduit Fitting (Option 03)\u003c\/strong\u003e provides safe, reliable cable entry and routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3\/4-14 NPT Mounting Thread (Option 02)\u003c\/strong\u003e enables direct, secure mechanical installation of the outer sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor Design\u003c\/strong\u003e eliminates the intermediate extension cable, improving signal integrity and reducing loop connection points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlass-Reinforced PPS Housing\u003c\/strong\u003e provides Type 4X and IP66 protection against chemical washdown, moisture, and corrosive atmospheric environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained applications where a separate Proximitor housing is not feasible.\u003c\/li\u003e\n  \u003cli\u003eCorrosive and harsh industrial environments, such as petrochemical plants, gas turbines, and water treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery monitoring requiring intrinsic safety or non-incendive approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-09-080-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e09\u003c\/td\u003e\n      \u003ctd\u003e90 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e80 mm probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-09-080-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe (with 1-metre cable inside sleeve)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Monitoring Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eO-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene (sleeve to housing), Viton (inside probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Fittings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOne M20 conduit fitting and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandoff Adapter Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Penetration Depth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing\/Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 percent condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Ensure correct grounding of the integrated shielding plate and terminal block. Prevent loops by grounding only at the monitor side or housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment\u003c\/strong\u003e: Set probe gap to the mid-voltage point (typically -10 Vdc for a 3300 XL 8 mm system) during installation to allow full mechanical dynamic range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Seal\u003c\/strong\u003e: Use appropriate sealing compound on conduit connections to prevent moisture and condensation from traveling through the conduit into the housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten probe sleeve locknuts to a maximum torque of 39.3 N-m (350 in-lb) and the retaining nut to 29.5 N-m (260 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean CE Mark\u003c\/strong\u003e: Compliant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection\u003c\/strong\u003e: IP66 housing rating (verified by BASEEFA).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e: Intrinsic Safety (Ex ia) and Non-Incendive\/Increased Safety (Ex nA\/ec) certifications for multiple global agencies (including ATEX, IECEx, and CSA) as designated by Option 28.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572439915,"sku":"330881-28-09-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-09-080-03-02-proxpac-xl-proximity-transducer-wrm01prbjri_4de71eec-f246-4979-96cf-af77396ae17f.jpg?v=1765440863"},{"product_id":"bently-nevada-330878-90-05-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-90-05 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (Multiple Approvals) specify this \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e configuration — \u003cstrong\u003e330878-90-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhile DIN mount configurations (Option 91) and 5.0-meter systems (Option 50 or 51) are available, this panel-mount, 9.0-meter system matches 330876 probes and 330877 extension cables for longer transmission distances. The Multiple Approvals selection allows installation in designated hazardous environments where compliance is required. The sensor utilizes advanced eddy-current technology to process displacement signals from a 50 mm probe, rendering it highly effective for differential expansion (DE) or rotor expansion (RX) measurements on steam turbine generators.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e Configured for a 9.0 m (29.5 ft) system length, providing compatibility with corresponding 50 mm probes and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel-mount physical design for secure attachment to mounting plates or internal enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Option 05 designates multiple global hazardous area certifications, including CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Built-in SpringLoc terminal strips provide fast, highly robust field connections without specialized tools.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e Robust design elements shield signal integrity against nearby high-frequency radio interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) measurement on utility steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eRotor expansion (RX) monitoring to track thermal growth differentials.\u003c\/li\u003e\n  \u003cli\u003eAxial position and displacement tracking in heavy industrial rotating machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 50 mm Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330878-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e27.9 mm (1100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBegins at 1.3 mm (50 mils) to 29.2 mm (1150 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e394 mV\/mm (10 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.74 mm (+\/-29 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccepts one 3300 XL 50 mm proximity probe and extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Terminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Field Wire Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA380 aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n      \u003cth\u003eWiring Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 to -26 Vdc)\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground reference\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDynamic analog output voltage signal\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Proximitor Sensor on a clean, flat surface using the standard panel-mount configuration holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Ensure the field wiring shield is connected to the monitor common ground and insulated at the Proximitor end to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Depress the SpringLoc lever, insert the stripped conductor (0.2 to 1.5 mm2), and release to secure. No special tools are needed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Cable Bend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for coaxial and triaxial system cables to prevent signal loss or conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCertification Body \/ Standard\u003c\/th\u003e\n      \u003cth\u003eApproval Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Community Directive 2014\/30\/EU (EMC) and RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNorth American Approvals (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc; Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2019 Rules for Conditions of Classification\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572603755,"sku":"330878-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330878-90-05-proximitor-sensor-gwpqylptnek_75a84746-c19c-440e-9220-efa4c992eccd.jpg?v=1765440866"},{"product_id":"bently-nevada-330180-x1-05-mod-145004-47-3300-xl-5mm-8mm-proximitor-sensor","title":"Bently Nevada 330180-X1-05 MOD 145004-47 3300 XL 5mm\/8mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-X1-05\u003c\/strong\u003e with modification code \u003cstrong\u003e145004-47\u003c\/strong\u003e is a proximity sensor conditioning device engineered for non-contact vibration, position, and displacement measurements. This \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e is calibrated to accommodate alternative target materials other than standard 4140 steel, generating a linear voltage output proportional to the gap between the probe tip and the target surface. The device serves as a primary component within proximity probe systems, interfacing directly with machinery monitoring platforms to track shaft dynamics and position in critical rotating machinery applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized target material recalibration under modification 145004-47\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy conversion of eddy-current probe impedance variation to stable DC voltage\u003c\/li\u003e\n\u003cli\u003eInteroperability with specific 5mm and 8mm proximity probe configurations\u003c\/li\u003e\n\u003cli\u003eRobust mechanical housing designed for harsh industrial deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact shaft vibration and displacement monitoring\u003c\/li\u003e\n\u003cli\u003eThrust position measurement in critical rotating machinery\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e 330180 (Proximitor Sensor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModification Code:\u003c\/strong\u003e 145004-47 (Recalibration to Specific Target Material)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e 3300 XL 5mm\/8mm 9m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModification Code\u003c\/td\u003e\n\u003ctd\u003e145004-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e10 to 90 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Zero\u003c\/td\u003e\n\u003ctd\u003e-3.0 Vdc @ 20 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Configuration\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5mm\/8mm 9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a dedicated electrical ground to prevent high-frequency noise from corrupting the sensor signal output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ensure all field wiring cables are properly shielded with the drain wires terminated at the monitor rack side only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Calibrate the physical probe gap using a digital voltmeter to verify the electrical zero setting of -3.0 Vdc at a 20-mil distance before securing the probe.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572898667,"sku":"330180-X1-05 MOD：145004-47","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-x1-05-mod-145004-47-proximitor-sensor-odczbzodjj0_9295702c-f8d3-4344-b88e-df2cd5d1db27.jpg?v=1765440870"},{"product_id":"bently-nevada-330881-br-05-060-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-05-060-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR (3300 XL 8 mm probe with INMETRO Brazilian approvals) and Option 05 (50 mm standoff adapter) specify this PROXPAC XL metric configuration — \u003cstrong\u003e330881-BR-05-060-00-02\u003c\/strong\u003e. This integrated proximity transducer assembly combines a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor into a single, self-contained unit. By eliminating the extension cable between the probe and Proximitor, this design simplifies field wiring and reduces installation complexity.\u003c\/p\u003e\n\u003cp\u003eThis metric configuration is equipped with a 60 mm probe penetration length (Option 060), utilizes a 3\/4-14 NPT mounting thread (Option 02), and includes no conduit fittings (Option 00, supplied with two plugs and two washers). The housing is molded from glass-reinforced, UV-resistant polyphenylene sulfide (PPS) thermoplastic with conductive fibers, providing protection rating up to IP66 and Type 4X for severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Sensor Assembly:\u003c\/strong\u003e Integrates a 1-meter 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor within the same rugged housing to eliminate the need for an external extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINMETRO Approvals (Option BR):\u003c\/strong\u003e Furnishes a 3300 XL 8 mm probe compliant with Brazilian INMETRO hazardous area standards for explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 mm Standoff Adapter (Option 05):\u003c\/strong\u003e Includes a 50 mm standoff adapter (B dimension) to adjust the housing height and clear machine obstructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 mm Penetration (Option 060):\u003c\/strong\u003e Configured with a 60 mm metric probe penetration sleeve length (C dimension) to accurately locate the probe tip relative to the target shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT Mounting (Option 02):\u003c\/strong\u003e Employs a 3\/4-14 NPT mounting thread option, which is standard for standoff installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFittings Configuration (Option 00):\u003c\/strong\u003e Supplied with no conduit fittings, containing two plugs and two washers for direct field-wire insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSevere-Environment Housing:\u003c\/strong\u003e Made from high-strength polyphenylene sulfide (PPS) thermoplastic to resist chemical attack, moisture, and impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration and axial position measurements on high-speed rotating machinery.\u003c\/li\u003e\n\u003cli\u003eMonitoring in hazardous petrochemical, oil and gas, and power generation environments requiring INMETRO certification.\u003c\/li\u003e\n\u003cli\u003eLocations with severe ambient conditions where separating Proximitor housings and using delicate extension cables is impractical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330881\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazil) Hazardous Area Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e50 mm Standoff Adapter Length (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e060\u003c\/td\u003e\n\u003ctd\u003e60 mm Probe Penetration Length (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330881-BR-05-060-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm (3300 XL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Input\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-meter cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleeve Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sleeve and Screws\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n\u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIP66 and Type 4X rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 Celsius (-62 to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe Only)\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 Celsius (-62 to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 to +105 Celsius (-62 to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor Output Signal (Negative Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTX\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper alignment of the 3300 XL 8 mm probe tip with the shaft target surface (minimum target diameter 15.2 mm).\u003c\/li\u003e\n\u003cli\u003eSet the nominal gap to 1.27 mm (50 mils) corresponding to the midpoint of the linear range.\u003c\/li\u003e\n\u003cli\u003eApply standard torque values: 29.5 N-m (260 in-lb) for the retaining nut and 39.3 N-m (350 in-lb) for the probe sleeve locknut.\u003c\/li\u003e\n\u003cli\u003eAvoid routing field wiring near high-voltage lines or sources of heavy electromagnetic fields. Maximum field wiring length should not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003ePrevent moisture ingress into the PPS housing by sealing the conduit entries and keeping plugs securely tightened.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European CE directives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e INMETRO (Brazil) Intrinsically Safe (Ex ia IIC T4\/T5 Ga) and Non-Incendive\/Increased Safety (Ex nA\/Ex ec IIC T4\/T5 Gc) via Option BR.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e IP66 and Type 4X rated housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666574209387,"sku":"330881-BR-05-060-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-05-060-00-02-proxpac-xl-housing-djzzxu0vkex_216859ff-edc2-4f39-bdcd-55c05a2fbee0.jpg?v=1765440887"},{"product_id":"bently-nevada-330880-16-15-020-01-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-15-020-01-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 16 (3300 XL 8 mm probe, unapproved), Option 15 (1.5 in standoff adapter), and Option 020 (2.0 in probe penetration length) define the specific configuration of the \u003cstrong\u003e330880-16-15-020-01-02\u003c\/strong\u003e integrated \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis self-contained assembly integrates a 3300 XL 8 mm proximity probe and a 1-meter cable directly inside the probe sleeve, eliminating the need for separate extension cables and dedicated sensor housings. It utilizes an advanced polyphenylene sulfide (PPS) thermoplastic housing containing glass and conductive fibers to strengthen construction and dissipate electrostatic charges in severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 16 provides an integrated 3300 XL 8 mm proximity probe without hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 15 specifies an English standoff adapter length of 1.5 inches (38 mm) for precise spacing.\u003c\/li\u003e\n  \u003cli\u003eOption 020 establishes a probe penetration depth of 2.0 inches (51 mm) into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eOption 01 supplies one 3\/4-14 NPT conduit fitting and two blanking plugs for robust cable sealing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 designates a 3\/4-14 NPT mounting thread for securing the outer sleeve assembly.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 3300 XL Proximitor sensor inside the housing cover eliminates the need for an external extension cable.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic construction offers IP66 and Type 4X environmental protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRotating machinery shaft vibration and axial position measurement\u003c\/li\u003e\n  \u003cli\u003eSimplified installations requiring integrated transducer and housing configurations\u003c\/li\u003e\n  \u003cli\u003eCritical industrial monitoring in power generation, chemical, and petrochemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e330880-16-15-020-01-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, English\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe, non-approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 inches (38 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option (C Dimension)\u003c\/td\u003e\n      \u003ctd\u003e020\u003c\/td\u003e\n      \u003ctd\u003e2.0 inches (51 mm) probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required if ordering standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330880-16-15-020-01-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Type\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Input\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-meter cable length installed in probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range Boundary\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -17 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% over linear range from 0 degC to +45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShaft Diameter Limits\u003c\/td\u003e\n      \u003ctd\u003eMinimum 50.8 mm (2.0 in), Recommended minimum 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Housing Material\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n      \u003ctd\u003e1-meter, 75 ohm triaxial, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Isolation Material\u003c\/td\u003e\n      \u003ctd\u003eExtra soft cellular silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnvironmental Protection Rating\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range (Probe)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range (Housing\/Proximitor)\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Wiring Size\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax Field Wiring Length\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) between Proximitor sensor and monitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrounding: Ensure the grounding liner and retaining plate are properly installed in accordance with standard Bently Nevada practices.\u003c\/li\u003e\n  \u003cli\u003eShielding: Use 3-conductor shielded twisted cable with a drain wire (e.g., 18 AWG field wiring) to limit electrical noise.\u003c\/li\u003e\n  \u003cli\u003eTorque Specifications: Retaining Nut: 29.5 N-m (260 in-lb); Probe Sleeve Locknut: 39.3 N-m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003eConduit Connections: Seal threaded fittings option (3\/4-14 NPT) with sealant or Teflon tape to maintain environmental rating.\u003c\/li\u003e\n  \u003cli\u003eOperation voltage: Ensure supply voltage is between -23.5 Vdc and -26 Vdc with barriers to maintain full linear range capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical Classification: Complies with the European CE mark.\u003c\/li\u003e\n  \u003cli\u003eEMC Directives: EMC Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4).\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003eMechanical\/Environmental: Type 4X and IP66 environments.\u003c\/li\u003e\n  \u003cli\u003eMaritime standards: ABS rules for conditions of classification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666578600299,"sku":"330880-16-15-020-01-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-16-15-020-01-02-proxpac-xl-proximity-transducer-gm1jeqfdedx_6c0bed14-e45f-4ccc-8b4f-589ec20d43cd.jpg?v=1765440936"},{"product_id":"bently-nevada-86497-01-02-02-00-cylinder-pressure-transducer","title":"Bently Nevada 86497-01-02-02-00 Cylinder Pressure Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e86497-01-02-02-00\u003c\/strong\u003e is a high-precision, industrial-grade \u003cstrong\u003ecylinder pressure transducer\u003c\/strong\u003e engineered specifically for dynamic pressure monitoring on reciprocating compressors and internal combustion engines. This specialized sensor captures high-frequency pressure changes inside active combustion or compression cylinders, transforming physical mechanical stress into an accurate electrical signal path for real-time thermodynamic diagnostics. The \u003cstrong\u003e86497-01-02-02-00\u003c\/strong\u003e interfaces seamlessly with advanced machinery diagnostic platforms, such as the Bently Nevada 3500\/77M Reciprocating Cylinder Pressure Monitor or System 1 software, to compute multi-point peak pressure variables, horse-power degradation indexes, and internal valve leakage symptoms.\u003c\/p\u003e\n\u003cp\u003eTo withstand the aggressive thermal shocks and chemical exposure typical of cylinder heads, the transducer assembly features a robust, corrosion-resistant stainless steel shell and an optimized piezoelectric sensing element. This specific option string dictates fixed operational boundaries, including standard physical thread patterns, a specialized top integrated connector setup, a specialized high-performance temperature insulation envelope, and default hazardous area approvals, ensuring safe, continuous structural asset protection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized piezoelectric architecture capturing high-speed dynamic pressure waveforms without mechanical lag.\u003c\/li\u003e\n\u003cli\u003eRugged stainless steel housing configuration providing long-term resistance to high-pressure combustion byproducts.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with high-density reciprocating machinery protection racks and thermodynamic analyzer software.\u003c\/li\u003e\n\u003cli\u003eExcellent thermal compensation boundaries preventing calibration drift under sustained cyclic heat loads.\u003c\/li\u003e\n\u003cli\u003eLow-profile physical footprint designed to fit into standardized cylinder head indicator valve ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time dynamic pressure charting and valve condition monitoring on heavy-duty reciprocating process compressors.\u003c\/li\u003e\n\u003cli\u003eContinuous combustion balancing and peak pressure calculation across large-bore industrial diesel and natural gas engines.\u003c\/li\u003e\n\u003cli\u003eAdvanced asset diagnostic reporting and efficiency optimization tracking on balance-of-plant gas pipeline skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497 (Cylinder Pressure Transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Code Assembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Thread Size and Adapter Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-02 (Connector Layout Variant Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-02 (Temperature \/ Performance Range Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-00 (Hazardous Area Certifications Option - Standard\/None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86497-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric Cylinder Pressure Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic internal cylinder pressure \/ dynamic gas force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Element Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial piezoelectric crystal configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-grade corrosion-resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Transmission Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharge or low-impedance voltage waveform proportional to pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size Option Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01 Option Specific Thread Geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 Option Specific Hermetic Connector Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Adaptation Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 Option Specific Temperature Compensation Envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals Option Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00 Standard \/ Non-hazardous industrial placement rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Core Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid body structure designed for structural indicator valve mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field pressure sensor assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop Integrated Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-insulation pin terminals for low-noise coaxial signal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Mounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThreaded mechanical interface for airtight indicator valve block attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRigid Port Mounting:\u003c\/strong\u003e Thread the sensor base directly onto the designated cylinder indicator valve port or specialized mounting adapter. Always torque the hex body to the exact engineering layout specifications to verify a leak-free mechanical seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Lead Routing:\u003c\/strong\u003e Connect a specialized low-noise coaxial cable loop to the top connector pins. Route this high-impedance signal run inside separate flexible metal conduit blocks away from high-current motor cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Mitigation Loops:\u003c\/strong\u003e Ensure that any integrated internal cooling passages or external protective shields are free from debris blockage to keep operational core temperatures inside the transducer sensor boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicator Valve Settings:\u003c\/strong\u003e When performing temporary analytical tests, ensure the physical indicator valve is closed completely prior to mounting or unmounting the pressure transmitter body to prevent high-pressure gas bypass accidents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666608779627,"sku":"86497-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-86497-01-02-02-00-interface-module-sy20htw12hz_f5f8226b-c119-41f6-8707-40dc8d913a9d.jpg?v=1765444112"},{"product_id":"bently-nevada-330780-12-00-3300-xl-11-mm-proximitor-sensor-1","title":"Bently Nevada 330780-12-00 3300 XL 11 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eBently Nevada 330780-12-00\u003c\/strong\u003e 3300 XL Proximitor Sensor is a non-contact eddy current displacement transducer designed for precise vibration and position monitoring of rotating machinery. This specific configuration, indicated by option -12, provides a full-scale range of 0.040 inches (1.0 mm) and is optimized for use with Bently Nevada 3300 XL 11 mm proximity probes. It is suitable for applications requiring high accuracy and reliability in challenging industrial environments.\n\nThis Proximitor sensor is a key component of the 3300 XL Proximity Transducer System, which also includes an 11 mm proximity probe and an extension cable. The -00 option signifies no specific agency approvals, making it suitable for general-purpose industrial installations where hazardous area certifications are not required. The 3300 XL series is known for its improved performance over older designs, offering enhanced immunity to radio frequency interference (RFI) and transient protection.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact eddy current measurement principle for vibration and position.\u003c\/li\u003e\n\u003cli\u003eConfigured with Option -12 for 0.040 in (1.0 mm) full-scale range, compatible with 3300 XL 11 mm probes.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy and linearity for critical machinery monitoring.\u003c\/li\u003e\n\u003cli\u003eImproved RFI\/EMI immunity meeting CE mark requirements.\u003c\/li\u003e\n\u003cli\u003eRobust design for reliable operation in industrial environments.\u003c\/li\u003e\n\u003cli\u003eOffers high transient overvoltage protection.\u003c\/li\u003e\n\u003cli\u003eStandard configuration, designated by -00, for non-hazardous areas.\u003c\/li\u003e\n\u003cli\u003eTypically mounted in a panel, DIN rail, or custom enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial position (thrust) measurement on turbines, compressors, and pumps.\u003c\/li\u003e\n\u003cli\u003eRadial vibration monitoring on large rotating machinery shafts.\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements.\u003c\/li\u003e\n\u003cli\u003eRod drop monitoring on reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eMonitoring shaft position relative to bearing clearances.\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring systems in power generation, oil and gas, petrochemical, and manufacturing industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Proximitor Sensor\u003c\/td\u003e\n\u003ctd\u003e330780\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Full-Scale Range\/Probe Compatibility\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm) Full-Scale Range, for 11 mm Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Agency Approval (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n\u003ctd\u003e330780-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probes, 3300 XL Extension Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc to -30 Vdc (typically -24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum, typical (without alarm option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-2 Vdc to -22 Vdc (typical linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range (FSR)\u003c\/td\u003e\n\u003ctd\u003e0.040 in (1.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0001 in (+\/-0.0025 mm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Operating)\u003c\/td\u003e\n\u003ctd\u003e-34 degC to +71 degC (-30 degF to +160 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Storage)\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN rail mount (with optional mounting clip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper installation is crucial for the optimal performance of the 3300 XL Proximitor Sensor. Ensure the sensor is securely mounted on a flat surface or DIN rail in a vibration-free area. All cables, including the probe and extension cables, must be routed away from sources of electrical noise and high-voltage lines to prevent interference. Grounding practices must adhere to Bently Nevada recommendations to ensure proper system performance and safety. The probe gap voltage should be set according to specific machinery requirements for accurate measurement and to utilize the full linear range of the Proximitor.\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\nThe 330780-12-00, specified with Option -00, does not include specific hazardous area agency approvals such as ATEX, IECEx, or CSA. It complies with general CE mark requirements for electromagnetic compatibility (EMC) and low voltage directive (LVD) for use in industrial environments.","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666609533291,"sku":"330901-00-90-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-90-10-01-05-3300-nsv-proximity-probes-0fsiu0gc41f_d5cb9fed-5442-47b8-bf87-ea592822f596.jpg?v=1765444120"},{"product_id":"bently-nevada-330880-ru-50-028-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-RU-50-028-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330880-RU-50-028-03-02\u003c\/strong\u003e: This English configuration of the Bently Nevada PROXPAC XL Proximity Transducer features Option RU for Russian EAC \/ TR CU hazardous area approvals, a 5.0-inch standoff adapter length (Option 50), and a 2.8-inch probe penetration depth (Option 028). Standardized as an integrated solution, it combines a 3300 XL 8 mm proximity probe and a Proximitor sensor inside a single Polyphenylene Sulfide (PPS) thermoplastic housing, eliminating the need for separate extension cables or junction boxes.\u003c\/p\u003e\n\u003cp\u003eEquipped with Option 03 fittings, the assembly includes one 3\/4-14 NPT fitting, a 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two plugs, mounting securely via a 3\/4-14 NPT thread (Option 02). This integrated transducer interfaces directly with 3300 XL monitoring system inputs over field wiring up to 305 meters, providing vibration and position measurements on rotating machinery where space, severe ambient conditions, or cable routing constraints restrict the use of discrete Proximitor housings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProbe and Approvals Option RU: Integrates a 3300 XL 8 mm proximity probe certified under Russian EAC \/ TR CU hazardous area safety standards.\u003c\/li\u003e\n  \u003cli\u003eStandoff Adapter Option 50: Configured with a 5.0-inch (127 mm) standoff adapter to adjust probe positioning relative to the machine casing.\u003c\/li\u003e\n  \u003cli\u003eProbe Penetration Option 028: Provides 2.8 inches (71 mm) of sleeve penetration depth into the machinery housing.\u003c\/li\u003e\n  \u003cli\u003eFittings Option 03: Supplied as a kit containing one 3\/4-14 NPT conduit fitting, one 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer, and two blanking plugs.\u003c\/li\u003e\n  \u003cli\u003eMounting Thread Option 02: Outfitted with a 3\/4-14 NPT mounting thread, required for installations using a standoff adapter.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Transducer Design: Houses both the proximity probe and the Proximitor sensor in one self-contained assembly, removing the intermediate extension cable.\u003c\/li\u003e\n  \u003cli\u003eRobust PPS Enclosure: Constructed from ultraviolet-resistant, glass-reinforced polyphenylene sulfide (PPS) containing conductive fibers for electrostatic dissipation.\u003c\/li\u003e\n  \u003cli\u003eHigh Environmental Protection: Rated for NEMA Type 4X and IP66 environments to protect internal circuitry against moisture and dust ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and axial position measurements in heavy industrial rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eMonitoring installations with severe environment exposures where separate extension cables are prone to damage.\u003c\/li\u003e\n  \u003cli\u003eSteam and gas turbines, compressors, gearboxes, and large industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery protection in regions requiring Russian EAC\/TR CU certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330880-RU-50-028-03-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (English)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals\u003c\/td\u003e\n      \u003ctd\u003eRU\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Russian EAC \/ GOST-R \/ TR CU hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 in (127 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration\u003c\/td\u003e\n      \u003ctd\u003e028\u003c\/td\u003e\n      \u003ctd\u003e2.8 in (71 mm) probe sleeve penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003e330880-RU-50-028-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe (1-metre cable length installed in sleeve)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) @ 12 mA max; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approx. 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003eApprox. -1 Vdc to -17 Vdc over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% (measured in 0.25 mm increments over 80 mil range, 0 degC to +45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.025 mm (+\/-1 mil) at 0 degC to 45 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres \/ 1,000 feet of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e76.2 mm (3.0 in) minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUV-resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRetaining Chain\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Sleeve \u0026amp; Retaining Screws\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Isolation\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLid Label Material\u003c\/td\u003e\n      \u003ctd\u003eGloss Radiant White Polyester\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing \u0026amp; Proximitor Sensor Temp\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRetaining Nut Torque\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Sleeve Locknut Torque\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVT \/ PWR\u003c\/td\u003e\n      \u003ctd\u003ePower Input\u003c\/td\u003e\n      \u003ctd\u003eNegative voltage supply connection (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon\u003c\/td\u003e\n      \u003ctd\u003eCircuit common and signal ground reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003eProportional dynamic voltage output (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Thread the outer sleeve assembly (Option 02) into the 3\/4-14 NPT machinery casing port, ensuring the standoff adapter (Option 50) is properly positioned and tightened to a torque of 39.3 N-m (350 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Adjust the probe depth within the sleeve (C sleeve depth of 2.8 inches) until the static output voltage reads approximately -10 Vdc, indicating the recommended gap of 1.27 mm (50 mils) from the target shaft surface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit and Fittings:\u003c\/strong\u003e Route field wiring through the 3\/4-14 NPT to 1\/2-14 NPT stainless steel reducer (Option 03). Use suitable sealing methods on the conduit threads to keep moisture from travelling into the IP66-rated PPS housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure electrical continuity from the internal grounding liner of the housing to the machine casing to maintain shielding effectiveness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRussian EAC \/ TR CU Hazardous Area Certifications (Option RU)\u003c\/li\u003e\n  \u003cli\u003eCE Mark Compliance (EMC Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eHousing Environmental Rating: NEMA Type 4X and IP66 (BASEEFA verified)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610155883,"sku":"330880-RU-50-028-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-ru-50-028-03-02-thermal-conductivity-transmitter-nljbyqcwdtn_14bc3df8-58c1-40df-b1fb-da715fcda1f6.jpg?v=1765444129"},{"product_id":"bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor","title":"Bently Nevada 330850-50-00 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330850-50-00\u003c\/strong\u003e specifies a 3300 XL 25 mm Proximitor Sensor configured with a 5.0-metre system length, flat-surface panel mounting, and no agency approvals. This sensor functions as an analog signal conditioner within a 3300 XL 25 mm Proximity Transducer System, generating a continuous voltage output directly proportional to the distance between a paired 25 mm probe tip and a target material.\u003c\/p\u003e\n\u003cp\u003eUnlike DIN-mount configurations or variants built with intrinsic safety approvals, this unit is designed specifically for general-purpose, non-hazardous area panels. It supports large-target displacement monitoring applications, such as steam turbine thrust position and differential expansion. The system is designed to provide stable performance over extended temperature ranges when paired with 330851 probes and 330854 extension cables.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem length of 5.0 metres (Option 50) is matched for calibration with standard five-meter probe and cable assemblies.\u003c\/li\u003e\n\u003cli\u003ePanel-mount mounting style (Option 50) comes complete with four 6-32 thread-forming mounting screws.\u003c\/li\u003e\n\u003cli\u003eNo agency approvals (Option 00) simplifies installation in standard general-purpose plant areas.\u003c\/li\u003e\n\u003cli\u003eSpringLoc terminal strips provide reliable, direct field wiring connections without requiring specialized crimping or landing tools.\u003c\/li\u003e\n\u003cli\u003eA380 aluminum housing is constructed to resist environmental corrosion and shield inner circuitry from electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eActive voltage regulation maintains high stability with less than 2 mV output drift per volt of supply input fluctuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurements on large utility turbine shafts\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod-drop and displacement tracking\u003c\/li\u003e\n\u003cli\u003eLarge-diameter rotor mechanical position and vibration analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 25 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Total Length and Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330850-50-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003eAccepts one 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range Limits\u003c\/td\u003e\n\u003ctd\u003eBegins at approximately 0.63 mm (25 mils) up to 13.33 mm (525 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor (ASF)\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) at standard operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Supply Requirement\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately -1.5 Vdc to -11.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 2.7 kHz (+0, -3 dB typical) with up to 305 metres of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Cable Support\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG); three-conductor shielded triad recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Distance\u003c\/td\u003e\n\u003ctd\u003e305 metres (1000 feet) to monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Limit\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Mass\u003c\/td\u003e\n\u003ctd\u003e255 g (9.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eDescription and Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd\u003eInputs from the paired 3300 XL 25 mm proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSystem Common \/ return path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eAnalog linear output voltage signal (-1.5 Vdc to -11.5 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT\u003c\/td\u003e\n\u003ctd\u003ePower supply input terminal (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor on a flat metal panel or enclosure surface using the four supplied 6-32 thread-forming panel screws. Strip external field wire insulation to reveal conductors from 0.2 to 1.5 mm2 (16 to 24 AWG) and insert directly into the SpringLoc terminal blocks. Thread coaxial connections finger-tight to ensure robust contact, not exceeding the maximum recommended torque limit of 0.565 Nm (5 in-lb). Maintain environmental conditions within the operating temperature limits and protect coaxial connectors with self-fusing silicone tape if moisture exposure is possible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666610450795,"sku":"330850-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor-m4rs1uhxyrc_80cfc98f-bc8c-4e7a-85d7-c44ac2edcd83.jpg?v=1765444134"},{"product_id":"bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-transducer-probe","title":"Bently Nevada AAP1407030-00100 3300 XL NSv Proximity Transducer Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada AAP1407030-00100\u003c\/strong\u003e (interchangeable with factory cross-reference code \u003cstrong\u003e109548-01 P1407030-00100\u003c\/strong\u003e) is a specialized, non-contact eddy-current eddy-current proximity probe sensor belonging to the high-density \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e (Narrow Side View) Series. Engineered specifically for industrial fluid-film bearing machinery with extremely tight installation spaces, it delivers an optimized radiation footprint to mitigate counterbore, side-view, or rear-view physical restrictions. The probe operates by generating a high-frequency electromagnetic field that measures static gap voltage displacements and dynamic vibration frequencies, transferring accurate shaft position signals to a paired 3300 XL NSv Proximitor Sensor. It is primarily deployed on small-diameter rotating assemblies such as centrifugal air compressors, refrigeration chillers, and process gas turbo-compressors where conventional 5 mm or 8 mm sensor tips encounter structural interference or scale factor distortion from confined housing walls.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eTransducer Subsystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEddy-current non-contact proximity probe sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eTarget Material Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAISI 4140 steel (standard calibration target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eLinear Sensing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eLinear Range Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.25 mm to 1.75 mm (10 mils to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eNominal Voltage Output Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eApproximate linear voltage span from -1 VDC to -13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over ambient limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eDeviation From Best Fit Straight Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLess than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eRecommended Operational Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eMinimum Shaft Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e30 mm (1.2 in) for standard radial X-Y configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eMinimum Flat Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e8.9 mm (0.35 in); 13 mm (0.5 in) recommended minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eProbe Tip Base Encapsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePolyphenylene sulfide (PPS) engineering thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eProbe Case Material Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eConnector Interface Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eGold-plated brass coaxial ClickLoc miniature connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eInternal Pressure Seal Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eIntegrated Viton O-ring for differential casing containment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-34 °C to +177 °C (-30 °F to +351 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eStorage Temperature Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e-52 °C to +105 °C (-62 °F to +221 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eOperational Altitude Max Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eNet Item Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.10 kg (0.22 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Factor Stability:\u003c\/strong\u003e For optimal eddy-current scaling, the target face must be flat and symmetric. If measuring on shaft diameters smaller than 30 mm (1.2 in) or flat profiles under 13 mm (0.5 in), reduction of the baseline gap voltage down towards the lower limit of the linear window may be necessary to correct for boundary attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide-View Clearance:\u003c\/strong\u003e The specialized configuration allows this probe to withstand close proximity to adjacent metallic structures. However, cross-talk or field distortions can occur if the clear side-view path dips below the structural limits of the machine's counterbore geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeability Rules:\u003c\/strong\u003e The probe must be paired exclusively with a 3300 XL NSv Proximitor Sensor and its corresponding 3300 NSv extension cable. Total electrical length configuration must be verified to prevent impedance mismatches across the channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Terminal Torque:\u003c\/strong\u003e Hand-tighten the gold-plated coaxial connectors until a physical, tactile \"click\" is felt. Never apply pliers or wrenches to the miniature joints, as over-torqueing can fracture the internal center pin conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Protection Measures:\u003c\/strong\u003e Use the factory-supplied silicone self-fusing tape to wrap outer connector couplings exposed to moisture or particulate contamination. Avoid deploying silicone wrapping sections within the internal machinery casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBending Radius Demands:\u003c\/strong\u003e Maintain a minimum structural bending radius of 25.4 mm (1.0 in) for standard probe leads and armored extensions to prevent macro-bending fractures within the internal coax core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How does the AAP1407030-00100 model manage differential pressure inside process compressor casings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The sensor case features a dedicated internal Viton O-ring pressure configuration. This barrier acts as a mechanical seal to isolate differential process gases from migrating up the internal probe core and into outer terminal junction boxes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the main differentiator between this NSv series probe and standard Bently Nevada 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The NSv series utilizes a highly narrowed electromagnetic sensing footprint. This allows it to accurate track radial vibration on miniature targets down to 8.9 mm in diameter where standard 8 mm probes would face extreme eddy-current side-loading errors from the machine walls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Is bench calibration or matched trimming mandatory when swapping out this sensor head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No. The product is manufactured to meet precise factory tolerance baselines, enabling complete structural interchangeability. Components can be swapped directly in the field without requiring bench recalibration or parameter scaling adjustments at the main machinery monitor rack.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666611302763,"sku":"AAP1407030-00100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-probe-d2meg0vkew2_586c6fc7-077f-4ccd-8eff-2a34f90b719e.jpg?v=1765444143"}],"url":"https:\/\/www.plcprotech.com\/vi\/collections\/transducers.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}