{"product_id":"bently-nevada-330980-71-05-3300-xl-nsv-proximitor-sensor","title":"Bently Nevada 330980-71-05 3300 XL NSv Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for specialized eddy-current machinery protection systems. This proximity sensor is purposefully optimized for demanding industrial deployment areas featuring compact installation constraints, such as centrifugal air compressors, process gas machinery, and refrigeration compression skids. It operates as a critical signal conditioner, converting raw electromagnetic gaps into a linear voltage signal to track machine health parameters.\u003c\/p\u003e\n\u003cp\u003eThe specific variant \u003cstrong\u003e330980-71-05\u003c\/strong\u003e is designated for a \u003cstrong\u003e7.0-meter (23.0 feet) total system loop length\u003c\/strong\u003e and is equipped with an integrated \u003cstrong\u003eDIN-rail mounting track pad\u003c\/strong\u003e. It includes \u003cstrong\u003eMultiple Agency Approvals\u003c\/strong\u003e for universal hazardous area safety installation compliance. Featuring robust RFI\/EMI shielding and specialized SpringLoc terminal blocks, this thin-profile aluminum sensor provides high-stability signal fidelity and effortless field wire terminations without the need for specialized routing tools.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for small-shaft targets under 51 mm (2 inches) and restricted side-view or counterbore clearances.\u003c\/li\u003e\n\u003cli\u003eConfigured for a 7.0-meter total system loop length balancing length requirements across compact infrastructure layouts.\u003c\/li\u003e\n\u003cli\u003eSnap-on 35mm DIN-rail mounting base plate ensuring reliable electrical isolation from structural enclosure grounds.\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area approvals certified for universal deployment across global plant environments.\u003c\/li\u003e\n\u003cli\u003eToolless SpringLoc terminal strip arrangement enabling fast, high-integrity field wiring connectivity.\u003c\/li\u003e\n\u003cli\u003eAdvanced onboard RFI\/EMI filtering achieving European CE compliance without restrictive shielding barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy radial vibration tracking and relative shaft position metrics on small-diameter high-speed rotors.\u003c\/li\u003e\n\u003cli\u003eCritical axial thrust displacement monitoring on fluid-filmed bearings with restrictive counterbore paths.\u003c\/li\u003e\n\u003cli\u003ePrecision zero-speed tracking, tachometer loops, and Keyphasor phase reference logging on industrial compressor skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980-71-05 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Hardware Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated DIN-rail mount backing pad \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 = Multiple Approvals (North America, ATEX\/Europe, IECEx, Brazil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) typical when calibrated to AISI 4140 steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approx 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 NSv or 3300 RAM probe and cable loop \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc (Unbarrier-assisted maximum consumption 12 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305m field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Target Terminal Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm squares (16 to 24 AWG) solid or stranded \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Structural Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 die-cast aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Component Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 grams (9 ounces) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +105 degC (-60 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible with protected ClickLoc connections \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Coaxial Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-loss gold-plated brass female thread port securing the incoming extension cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpringLoc Terminal Strip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-station toolless spring cage landing for Signal, Common, and Supply wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Pad Track Tabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStructural clip array mating the isolated casing onto standard 35mm DIN-rails \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Snap the Proximitor Sensor base pad securely onto standard 35mm DIN rail tracks. Ensure the underlying replacement mounting pad isolates the metal chassis frame from raw cabinet ground grids to eliminate loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched Loop Length Balance:\u003c\/strong\u003e Verify that the combined mechanical lengths of the attached 3300 NSv probe and extension cable sum to exactly 7.0 meters to maintain calibrated scale factors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wire Termination:\u003c\/strong\u003e Use recommended three-conductor shielded triad cable (16 to 24 AWG). Depress the SpringLoc cage clips to seat bare wire ends completely before releasing tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Weatherproofing:\u003c\/strong\u003e Install specialized male\/female connector protectors or apply a wrap of self-fusing silicone tape over the coaxial links to block process fluids and maintain 100% condensing humidity defenses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668334342507,"sku":"330980-71-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330980-71-05-w4t4nu5gz1z_6c5fa473-8266-4734-87b8-42bf5db3ac2d.jpg?v=1765521444","url":"https:\/\/www.plcprotech.com\/vi\/products\/bently-nevada-330980-71-05-3300-xl-nsv-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}