{"product_id":"ge-is215wepah2ba-mark-vie-wind-energy-pitch-axis-control-module","title":"General Electric IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS215WEPAH2BA\u003c\/strong\u003e is a wind energy pitch axis control module developed by General Electric as part of the Mark VIe Wind turbine control system series. This printed circuit board acts as a specialized hardware control interface designed to regulate pitch axis adjustments, mechanical braking variables, and torque parameters within main wind turbine assemblies. Engineered for precision tracking under 30 MN system environments, the \u003cstrong\u003eIS215WEPAH2BA\u003c\/strong\u003e operates without CAN bus dependency, hosting direct data paths across three independent serial communication ports and an auxiliary onboard network interface. The assembly consists of a primary board protected by a full conformal surface coating linked directly to a lower right-hand daughterboard configuration. To shield sensitive tracking logic from volatile voltage fluctuations, the board integrates a built-in array of metal oxide varistors alongside continuous voltage suppression networks, allowing it to maintain operational integrity in harsh environmental contexts across both simplex and dedicated triple modular redundant (TMR) structural layouts.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControls and regulates critical wind energy pitch axis adjustments and torque variations\u003c\/li\u003e\n\u003cli\u003eFeatures a two-fold revision structure designated by an initial B-rated and secondary A-rated functional revision\u003c\/li\u003e\n\u003cli\u003eOutfitted with a complete layer of conformal PCB surface coating for enhanced component environmental defense\u003c\/li\u003e\n\u003cli\u003eIntegrates three distinct serial communication ports (COM1, COM2, and a micro-miniature 9-pin socket D connector)\u003c\/li\u003e\n\u003cli\u003eSupports direct localized networking paths using an onboard 10BaseT\/AUI Ethernet connector interface\u003c\/li\u003e\n\u003cli\u003eFeatures four metal oxide varistors arranged strategically across the upper right and lower left board quadrants\u003c\/li\u003e\n\u003cli\u003eAccommodates execution speeds across three distinct software frame rates ranging from ten to forty milliseconds\u003c\/li\u003e\n\u003cli\u003eBuilt to interface with female edge plug connectors scaling from two to twenty pins in length\u003c\/li\u003e\n\u003cli\u003ePermits live application software updates under five distinct levels of structural password protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtility-scale wind turbine pitch axis motor control loops\u003c\/li\u003e\n\u003cli\u003eDynamic torque calculation and rotor blade feathering adjustment systems\u003c\/li\u003e\n\u003cli\u003eSimplex or triple modular redundant (TMR) wind energy control installations\u003c\/li\u003e\n\u003cli\u003eHarsh-environment industrial power generation telemetry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIS215WEPAH2BA \/ IS215WEPAH2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe Wind\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eWind Energy Pitch Axis Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eWEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrinted Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbine Type\u003c\/td\u003e\n\u003ctd\u003eWind Turbine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMN Rating\u003c\/td\u003e\n\u003ctd\u003e30 MN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN Bus Compatibility\u003c\/td\u003e\n\u003ctd\u003eNon CAN bus-compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e3 (COM1, COM2, and micro-miniature 9-pin socket D connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e10BaseT\/AUI connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Rating\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Frame Rates\u003c\/td\u003e\n\u003ctd\u003e10, 20 and 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Metal Oxide Varistors\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFemale Plug Connectors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Board Protection\u003c\/td\u003e\n\u003ctd\u003eConformal Protective Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e10G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd\u003eGEP-9145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface Slot \/ Connector\u003c\/th\u003e\n\u003cth\u003eFunction \/ Technical Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1 \/ COM2\u003c\/td\u003e\n\u003ctd\u003eIndependent communication ports for local data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9-Pin Socket D Connector\u003c\/td\u003e\n\u003ctd\u003eMicro-miniature serial connection interface for diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10BaseT\/AUI Connector\u003c\/td\u003e\n\u003ctd\u003eDedicated physical port handling local area Ethernet communication lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEdge Plug Connectors\u003c\/td\u003e\n\u003ctd\u003eTwo female plug connectors ranging from 2 to 20 pins for peripheral mating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVME Rack Slot\u003c\/td\u003e\n\u003ctd\u003eSingle-slot interface matching standard 13-slot or 21-slot VME chassis rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Slide the control board assembly into a single designated slot of a 13-slot or 21-slot VME rack housed inside the main cabinet container.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaughterboard Inspection:\u003c\/strong\u003e Prior to installation, verify the structural interlocking integrity of the small daughterboard located on the lower right-hand corner of the main PCB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Input Constraints:\u003c\/strong\u003e Ensure the primary power lines connected to the board match the rated 125 VDC input parameters to prevent damage to the overvoltage suppression components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Controls:\u003c\/strong\u003e Ensure ambient relative humidity levels remain within the 10-95% non-condensing operating threshold to prevent moisture accumulation on the edge connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420469611,"sku":"IS215WEPAH2BA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is215wepah2ba-printed-circuit-board-if3jfkg30xz_699a7061-763e-4764-8a9b-be4ea478083e.jpg?v=1766135393","url":"https:\/\/www.plcprotech.com\/vi\/products\/ge-is215wepah2ba-mark-vie-wind-energy-pitch-axis-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}