1 of 6

ABB TU810V1 3BSE013230R1 S800 I/O Compact Module Termination Unit

ABB TU810V1 3BSE013230R1 S800 I/O Compact Module Termination Unit

Only 5 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 3BSE013230R1

  • Country of origin:Sweden

  • Product Type: Compact Module Termination Units

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 165 mm x 45 mm x 72 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Serving as a robust connection interface within the S800 I/O distributed automation architecture, the ABB TU810V1 (part number 3BSE013230R1) acts as a compact module termination unit designed to route signals reliably between field wiring and active I/O process modules. This unit accommodates up to 16 independent channels, operating at a maximum rating of 50V, making it a critical component for high-density cabinet layouts where footprint optimization is vital.

Features

  • High-Density Compact Footprint: Allows direct horizontal or vertical DIN-rail mounting to minimize cabinet space requirements.
  • 16-Channel Configuration: Routes up to 16 individual I/O channels alongside dual process voltage connections.
  • Mechanical Coding Keys: Prevents mismatched module insertion, safeguarding the active electronics from field configuration errors.
  • Integrated Modulebus Link: Seamlessly transfers signals and power to adjacent units without external jumper cables.
  • Dual Voltage Distribution: Includes 2 isolated groups with commoned terminal distribution points.

Applications

  • Advant OCS and System 800xA distributed control architectures.
  • Petrochemical, power generation, and water treatment field-instrumentation processing.
  • High-density electrical marshaling cabinets and field junction boxes.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Designation TU810V1
Product ID / SKU 3BSE013230R1
Series S800 I/O
Type Compact Module Termination Unit (MTU)
Number of Channels 16 channels
Rated Voltage 50 V DC / AC maximum
Rated Current 3 A per channel maximum
Connection System Single-wire screw clamp terminals
Conductor Size 0.2 to 2.5 mm² (24 to 14 AWG)
Modulebus Load Negligible (passive routing)
Dimensions (H x W x D) 165 mm x 45 mm x 72 mm
Weight 0.20 kg
Commodity Code 85389091

Connections and Interfaces

Terminal / Connector Point Function / Circuit Assignment
Terminals 1 to 16 I/O Channel connections (Signals 1 to 16)
Terminals 17 & 18 Process Voltage Common 1 (distribution bus)
Terminals 19 & 20 Process Voltage Common 2 (distribution bus)

Empirical Engineering Insights

Alternative Models & Compatibility

The TU810V1 serves as a direct, drop-in evolution of the legacy TU810 compact MTU. The V1 variant features improved thermal tolerance and mechanical housing updates, ensuring absolute backward-compatibility with all existing S800 I/O modules that require a 50V connection interface. If upgrading from non-V1 units, no software modifications or engineering changes are required in the System 800xA or Control Builder environments.

Application Pitfalls & Engineering Notes

While rated for 50V operational limits, designers must verify that the total accumulated current across all 16 connected channels does not exceed the capacity of the power distribution source. In highly compact enclosures, field wiring must be routed systematically to prevent localized heating near the screw terminals, which could accelerate degradation of the adjacent active I/O modules.

Commissioning & Wiring Tips

To ensure noise immunity in electromagnetic interference (EMI) heavy environments, signal cables should be shielded up to the cabinet entrance, and shields must be grounded to a designated bar separate from the MTU. Ensure that the plastic coding keys on the MTU base are properly configured to match the corresponding module type before power-up to prevent physical component damage during hot-swapping procedures.

Installation Guidelines

CRITICAL WARNING: Complete physical isolation and de-energization of the field supply and Modulebus backplane are mandatory before mounting, unmounting, or wiring the MTU. Failure to isolate power may cause electrical arcing, module destruction, or hazardous field conditions.
1

Mount the TU810V1 MTU onto a grounded 35mm horizontal DIN rail by latching the top groove and snapping the lower locking tab onto the rail.

2

Slide the unit laterally along the DIN rail to connect its Modulebus port directly to the adjacent MTU/Modulebus optical port, ensuring the connection latches completely.

3

Strip field signal and distribution wires to 6mm, insert them into the screw terminals (terminals 1-20), and torque them uniformly to 0.5 Nm.

4

Configure the physical mechanical coding keys on the MTU surface to correspond with the targeted I/O module type before docking the electronic module.

What is the primary difference between the TU810 and the TU810V1?

The TU810V1 features updated high-temperature resistant polymers and optimized internal routing traces, offering 100% direct drop-in backward compatibility with older legacy TU810 models.

Does this termination unit support live module hot-swapping?

Yes. S800 I/O modules can be plugged in or unplugged under power from the MTU, provided active loop safety processes permit the live intervention.

What is the maximum torque rating for the field wiring terminals?

The field screw clamp terminals on this MTU should be tightened to a maximum torque specification of 0.5 Nm to prevent mechanical stress on the printed circuit board.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...