1 of 3

Allen-Bradley 1785-LT/B 1785-LT Series B PLC-5 Processor Module

Allen-Bradley 1785-LT/B 1785-LT Series B PLC-5 Processor Module

Only 3 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1785-LT/B

  • Country of origin:United States

  • Product Type: Prosessor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1440g

  • Dimensions: 4.6cm x 16cm x 27.4cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Allen-Bradley 1785-LT/B is a programmable logic controller hardware component that functions specifically as a PLC 5/15 processor module within the classic PLC-5 hardware line. It serves as the primary control unit to execute user application ladder logic, govern localized signal scanning, and coordinate peripheral network routing. For processing physical parameters, this processor provides simultaneous architecture expansion that manages up to four local I/O chassis racks alongside up to three universal remote I/O link channels. Built-in standalone communication interfaces include a specialized Remote I/O scanner adapter combined with a Data Highway Plus (DH+) station port, facilitating direct parallel data transmission to operator workstations, supervisory automation interfaces, and third-party interface systems without interrupting primary control cycles.

Features

  • Dual integrated network pathways containing an independent local or remote I/O scanning link plus a separate Data Highway Plus (DH+) industrial channel.
  • Dual-option hardware configuration switches permitting user control over physical I/O output states during active communication fault conditions.
  • Multi-slot physical addressing capacity supporting 2-slot, 1-slot, and 1/2-slot input/output group placement mapping.
  • Slide-in backplane alignment structural base designed for installation inside the left-most slot position of standard 1771-I/O chassis enclosures.

Applications

  • High-reliability automation control loop execution in factory manufacturing environments.
  • Centralized multi-chassis industrial system expansion via remote and local input/output link networks.
  • Distributed plant automation cell integration using Data Highway Plus architectures.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley
Model Number 1785-LT/B
Product Line PLC-5
Module Type Processor
Supported Local I/O Up to 4 Racks (1 resident rack)
Supported Remote I/O Up to 3 Remote I/O racks
I/O Capacity 512 I/O; 512 inputs and 512 outputs using 16 or 32-pt modules
Max Total I/O 3072 (any mix) or 3072 in + 3072 out (complementary)
Analog I/O Capacity 512
Max Analog I/O 3072
Embedded RAM 6K Words SRAM (expandable up to 14K Words)
Optional Memory Modules 4K RAM expansion (1785-MR); 8K RAM expansion (1785-MS); 8K EEPROM (1785-MJ)
Backup Battery Model 1770-XY
Program Scan Time 2 ms/K words (bit logic); 8 ms/K words (typical)
I/O Scan Time Per Rack 10 ms at 57.6 kbits/s, 7 ms at 115.2 kbits/s, 3 ms at 230.4 mbits/s
Max I/O Chassis Total 93
Max Universal Remote Chassis 32 max. per I/O link
Built-In Ports 1x Standalone Scanner (local and remote I/O); 1x DH+; 1x RS-232-C/422-A/423-A
Control Coprocessor Port Yes
Hardware Addressing 2-slot, 1-slot, 1/2-slot
Chassis Location 1771-I/O chassis, left-most slot
Mechanical Keying Position Between 40 and 42; between 54 and 56
Weight 3.06 lbs (1.39 kg)
Operating Temperature 0 to 60 degC (32 to 140 Fahrenheit)
Storage Temperature -40 to 85 degC (-40 to 185 Fahrenheit)
Relative Humidity 5% to 95% noncondensing
Operating Shock 30 g (3 pulses, 11 ms)
Nonoperating Shock 50 g (3 pulses, 11 ms)
ESD Immunity 4 kV contact discharges

Installation Guidelines

  • Chassis Slot Placement: Slot the module strictly into the left-most dedicated processor position of the 1771-I/O chassis frame, ensuring the guide keys align smoothly with backplane markers between slots 40/42 and 54/56.
  • Fault Mode Switch Setup: Adjust configuration Switch 1 to the OFF position prior to startup to force the local chassis to safely strip away output energy if a fatal processing or communication error occurs.
  • ESD Shielding Safety: Ensure full connection to a reliable grounding strap during manual deployment or component adjustments to block static path discharges into the internal processing logic boards.

Compliance and Certifications

  • EN 50081-2 EMC - Generic Emission Standard for operation in a Part 2 - Industrial Environment

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1785-LT/B 1785-LT Series B PLC-5 Processor Module

What happens to the connected chassis outputs if Switch 1 is placed in the ON position?

If communication errors occur while the switch is ON, the outputs stay locked in their final recorded state to allow continuous physical machine movement.

What specific backup battery code matches this hardware assembly?

The module uses the 1770-XY system battery to maintain data retention loops.

What type of expansion memory hardware can be added to the device?

The memory can be expanded up to 14K words using the 1785-MR 4K RAM, 1785-MS 8K RAM, or 1785-MJ 8K EEPROM modules.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...