1 of 4

Honeywell CC-PUIO31 51454220-176 Series C Universal I/O Module-2

Honeywell CC-PUIO31 51454220-176 Series C Universal I/O Module-2

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-PUIO31 51454220-176

  • Country of origin:United States

  • Product Type: Universal I/O Module

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 8.7 cm × 6.4 cm × 9.1 cm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The CC-PUIO31 is a Universal Input/Output Module designed for Honeywell Series C control architectures. Introduced with software release R432, this high-density hardware component integrates seamlessly into the Series C Unified Hybrid Input/Output (UHIO) configuration alongside the C300 Controller and Control Firewall. The CC-PUIO31 module offers flexible signal management by providing 32 soft-configurable channels on a single module, allowing engineers to interface various field instruments without changing the physical I/O hardware footprint.

Features

  • Provides 32 fully configurable input or output channels on a single module assembly
  • Soft-configurable channel attributes match the foundational operational capabilities of the CC-PUIO01 module
  • Integrated within Series C UHIO systems to support distributed I/O process automation architectures
  • Managed via standard internal block parameters using the UIO IOM block definition

Applications

  • Distributed process automation inside Honeywell Series C control networks
  • Flexible field instrument interfacing with soft-configurable input/output distributions
  • Unified Hybrid Input/Output (UHIO) configuration deployments alongside C300 controllers

Technical Specifications

Parameter Description
Manufacturer Honeywell
Model Number CC-PUIO31
Part Number 51454220-176
IOM Model Names CC-PUIO31 / CC-PUIO3
IOM Block Name UIO
Module Type Universal Input/Output Module (UIO-2 Module)
Number of Channels 32
System Compatibility Series C UHIO / R432 and higher

Installation Guidelines

  • System Integration: Mount the module within the designated Series C UHIO chassis layout or carrier slot ensuring correct mechanical alignment with the backplane connectors.
  • Component Pairing: Verify compatibility and proper bus connections with the 9-port Control Firewall (CC-PCF901) and C300 Controller (CC-PCNT02) when deploying standard UHIO configurations.
  • Channel Assignment: Configure the 32 input or output channel types programmatically within the UIO block definition before connecting external field loops.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-PUIO31 51454220-176 Series C Universal I/O Module-2

What is the primary difference between the CC-PUIO31 and the CC-PUIO01?

The CC-PUIO31 was introduced in Experion PKS system release R432 with updated internal componentry. It behaves identically to the CC-PUIO01 but requires R432 or later firmware to be correctly identified by C300 controllers.

Can the CC-PUIO31 handle HART protocol on all channels simultaneously?

Yes, any of the 32 channels configured as Analog Inputs (AI) can carry HART digital communication simultaneously, allowing asset management software to communicate with smart transmitters.

What does the 'CC' prefix indicate on the Honeywell part number?

The 'CC' prefix designates that the assembly is conformally coated, providing protection for internal circuits in G3-level harsh or corrosive gas environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...